Abstract:
:This paper deals with the impact force during foot-ground impact activities such as the running. A previously developed model is used for this study. The model is a lumped-parameter one consisting of four masses connected to each other via linear springs and viscous dampers. A shoe-specific nonlinear function is used for representation of the ground reaction force. The authors have previously showed that the previous version of the model as well as its simulation is incorrect. This paper slightly modifies the previous model so as it is able to produce results in agreement with the experiments. Then, the modified model is simulated for two typical shoe types. A parametric study is also conducted. The parametric study concerns with the effects of masses, mass ratios, stiffness constants, and damping coefficients on the dynamics of the impact. It is shown that the impact forces increase as the rigid and wobbling masses increase. However, the increase in the impact forces is not the same for all the masses. It is found that the impact force increases as the touchdown velocities increase. Simulations imply that the variations of the damping coefficients result in larger variations of the impact force compared to the stiffness. The effect of the variation of gravity on the simulated impact force is also explored. It is concluded that both the first and the second peaks of the impact force are increased with gravity. An in-depth discussion is included to compare results of the current paper with results of other investigators.
journal_name
J Biomechjournal_title
Journal of biomechanicsauthors
Zadpoor AA,Nikooyan AA,Arshi ARdoi
10.1016/j.jbiomech.2006.09.016subject
Has Abstractpub_date
2007-01-01 00:00:00pages
2012-21issue
9eissn
0021-9290issn
1873-2380pii
S0021-9290(06)00356-3journal_volume
40pub_type
杂志文章abstract::Tripping over obstacles is the most frequently mentioned causes of falls. Thus, this study was performed to test the hypotheses that when crossing obstacles, toe-obstacle clearance and the three-dimensional motions and moments at the hip, knee, and ankle of the trailing limb (limb crossing the obstacle last) increase ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/s0021-9290(96)00161-3
更新日期:1997-04-01 00:00:00
abstract::Spinal stability is related to the recruitment and control of active muscle stiffness. Stochastic system identification techniques were used to calculate the effective stiffness and dynamics of the trunk during active trunk extension exertions. Twenty-one healthy adult subjects (10 males, 11 females) wore a harness wi...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2004.09.014
更新日期:2005-10-01 00:00:00
abstract::Spinal arthrodesis continues to expand in clinical indications and surgical practice. Despite a century of study, failure of bone formation or pseudarthrosis can occur in individual patients with debilitating clinical symptoms. Here we review biological and technical aspects of spinal fusion under active investigation...
journal_title:Journal of biomechanics
pub_type: 杂志文章,评审
doi:10.1016/j.jbiomech.2010.10.021
更新日期:2011-01-11 00:00:00
abstract::Children with severe osteogenesis imperfecta (OI) typically experience numerous fractures and progressive skeletal deformities over their lifetime. Recent studies proposed finite element models to assess fracture risk and guide clinicians in determining appropriate intervention in children with OI, but lack of appropr...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2017.09.003
更新日期:2017-11-07 00:00:00
abstract::A composite cushion acetabular cup for a total hip replacement has been designed and developed jointly by Leeds University and DePuy International. In order to assess the long-term performance of this novel design, two sets of simulator tests of more than 4 million cycles duration have been carried out with the cushio...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/s0021-9290(98)00034-7
更新日期:1998-04-01 00:00:00
abstract::A finite-element micromechanics model for Haversian cortical bone tissue has been developed and studied. The model is an extension of two-dimensional micromechanics techniques for fiber-reinforced composite materials. Haversian systems, or secondary osteons, are considered to be the fiber component, and interstitial l...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(92)90095-i
更新日期:1992-05-01 00:00:00
abstract::Gait analysis is a quantitative, non-invasive technique that can be used to investigate functional changes in animal models of musculoskeletal disease. Changes in ground reaction forces following injury have been observed that coincide with differences in tissue mechanical and histological properties during healing. H...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2015.12.027
更新日期:2016-02-08 00:00:00
abstract::Accurate measurement of six-degrees-of-freedom in-vivo kinematics of the total hip arthroplasty (THA) is essential in gaining insights into in-vivo THA performance. The objective of this study was to validate a novel dual fluoroscopy imaging system (DFIS) for determination of the THA kinematics using both in-vitro and...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2013.02.010
更新日期:2013-04-26 00:00:00
abstract::It is clinically challenging to distinguish between ankle and subtalar joints instability in vivo. Understanding the changes in load-displacement at the ankle and subtalar joints after ligament injuries may detect specific changes in joint characteristics that cannot be detected by investigating changes in range of mo...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2018.10.033
更新日期:2019-01-03 00:00:00
abstract::Topically applied microbicide gels can provide a self-administered and effective strategy to prevent sexually transmitted infections (STIs). We have investigated the interplay between vaginal tissue elasticity and the yield-stress of non-Newtonian fluids during microbicide deployment. We have developed a mathematical ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2015.01.049
更新日期:2015-06-25 00:00:00
abstract::The biomechanical characteristics of bone tissue and its cells under mechanical stress are significant for bone biomechanics research, but the mechanism of mechanotransduction is still unknown. It has been established that the actin cytoskeleton of osteoblasts plays an important role in this process. However, the stru...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2008.08.010
更新日期:2008-11-14 00:00:00
abstract::Tendons are elastic structures that connect muscle to the skeletal system and transmit force relative to the amount of stretch they experience. The mechanical properties of human tendons are difficult to measure non-invasively, so generic values are often assumed in musculoskeletal models to represent all subjects. We...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2015.06.009
更新日期:2015-09-18 00:00:00
abstract::Dentin, the mineralized tissue forming the bulk of the tooth, lies between the enamel and the pulp chamber. It is a rich source of inspiration for designing novel synthetic materials due to its unique microstructure. Most of the previous studies investigating the fracture toughness of dentin have used linear-elastic f...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2008.01.015
更新日期:2008-01-01 00:00:00
abstract::Accurate modeling of soft tissue motion effects relative to bone during impact requires knowledge of the mass of soft and rigid tissues in living people. Holmes et al., [2005. Predicting in vivo soft tissue masses of the lower extremity using segment anthropometric measures and DXA. Journal of Applied Biomechanics, 21...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2008.02.013
更新日期:2008-01-01 00:00:00
abstract::Blood platelets when activated are involved in the mechanisms of hemostasis and thrombosis, and their migration toward injured vascular endothelium necessitates interaction with red blood cells (RBCs). Rheology co-factors such as a high hematocrit and a high shear rate are known to promote platelet mass transport towa...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2017.06.044
更新日期:2017-08-16 00:00:00
abstract::The goal of this work consists in a quantitative analysis and constitutive modelling of ageing processes associated to plaque formation in mice arteries. Reliable information on the characteristic evolution of pressure-stretch curves due to the ageing effects is extracted from previous inflation test experiments. Furt...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2016.01.043
更新日期:2016-08-16 00:00:00
abstract::Continuous flow blood fraction separators are used to facilitate the removal of specific blood components for donation or for certain medical procedures. Problems with one such device, the IBM 2997 Blood Processor, have been noted in a number of independent investigations. A key feature of this particular unit is a ce...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(86)90163-6
更新日期:1986-01-01 00:00:00
abstract::A dual-indentation creep and stress relaxation methodology was developed and validated for the material characterization of very soft biological tissue within the framework of the biphasic poroviscoelastic (BPVE) constitutive model. Agarose hydrogel, a generic porous medium with mobile fluid, served as a mechanical ti...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2005.07.019
更新日期:2006-01-01 00:00:00
abstract::In this study the investigations made on about 50 trunk tissue densities are described. They were performed on ten cadavers of both sexes within 24 h of the moment of death. They were 20-40 yr old. The weight of each tissue was measured on a laboratory scale and the volume by placing the tissue in a pycnometer filled ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(90)90360-f
更新日期:1990-01-01 00:00:00
abstract::Magnetic resonance imaging (MRI) could potentially be used to non-invasively predict the strength of an ACL graft after ACL reconstruction. We hypothesized that the volume and T2 relaxation parameters of the ACL graft measured with MRI will predict the graft structural properties and anteroposterior (AP) laxity of the...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2011.09.004
更新日期:2011-11-10 00:00:00
abstract::Lymphatic valves facilitate the lymphatic system's role in maintaining fluid homeostasis. Malformed valves are found in several forms of primary lymphœdema, resulting in incurable swelling of the tissues and immune dysfunction. Their experimental study is complicated by their small size and operation in low pressure a...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2017.09.040
更新日期:2017-11-07 00:00:00
abstract::Flatfoot is a risk factor for patellofemoral pain syndrome (PFPS), and excessive rearfoot eversion occurring in flatfoot has been associated with the development and progression of PFPS; however, the mechanism remains unclear. This study aimed to investigate transverse shank and frontal rearfoot coordination patterns ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2020.110119
更新日期:2021-01-22 00:00:00
abstract::As 3-dimensional (3D) motion-capture for clinical gait analysis continues to evolve, new methods must be developed to improve the detection of gait cycle events based on kinematic data. Recently, the application of principal component analysis (PCA) to gait data has shown promise in detecting important biomechanical f...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2014.06.009
更新日期:2014-08-22 00:00:00
abstract::To date, the diagnosis of whiplash injuries has been very difficult and largely based on subjective, clinical assessment. The work by Winters and Peles Multiple Muscle Systems--Biomechanics and Movement Organization. Springer, New York (1990) suggests that the use of finite helical axes (FHAs) in the neck may provide ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(94)90192-9
更新日期:1994-12-01 00:00:00
abstract::Aseptic loosening from polyethylene wear debris is the leading cause of failure for metal-on-polyethylene total hip implants. Third-body debris ingress to the bearing space results in femoral head roughening and acceleration of polyethylene wear. How third-body particles manage to enter the bearing space between the c...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2007.01.021
更新日期:2007-01-01 00:00:00
abstract::Bone mineral density (BMD) is the principal diagnostic tool used in clinical settings to diagnose and monitor osteoporosis. Experimental studies on ex vivo bone samples from multiple skeletal locations have been used to propose that their breaking stress bears a power-law relationship to volumetric BMD, with a locatio...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2003.12.001
更新日期:2004-08-01 00:00:00
abstract::Incisional hernia development is a significant complication after laparoscopic abdominal surgery. Intra-abdominal pressure (IAP) is known to initiate the extrusion of intestines through the abdominal wall, but there is limited data on the mechanics of IAP generation and the structural properties of rectus sheath. This...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2014.03.009
更新日期:2014-06-03 00:00:00
abstract::We compare the predictions of the differential equation form of a class of bone-density stress adaptation models with their associated discrete-time computational algorithms. Although our considerations apply to the class of adaptation models based on bulk or apparent bone-density remodeling, we focus attention on a p...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/s0021-9290(05)80007-7
更新日期:1993-09-01 00:00:00
abstract::We evaluated whether the use of cartilage thickness measurement would improve the ability of the arthroscopic indentation technique to estimate the intrinsic stiffness of articular cartilage. First, cartilage thickness and ultrasound reflection from the surface of bovine humeral head were registered in situ using a hi...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/s0021-9290(00)00189-5
更新日期:2001-02-01 00:00:00
abstract::Theoretical concerns about the use of cemented or press-fit stems in revision total knee arthroplasty (TKA) include stress shielding with adverse effects on prosthesis fixation. Revision TKA components are commonly stemmed to protect the limited autogenous bone stock remaining. Revision procedures with the use of stem...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2007.10.006
更新日期:2008-01-01 00:00:00