Abstract:
:The natural stress distribution in the femur is significantly altered after total hip arthroplasty (THA). When an implant is introduced, it will carry a portion of the load, causing a reduction of stress in some regions of the remaining bone. This phenomenon is commonly known as stress shielding. In response to the changed mechanical environment the shielded bone will remodel according to Wolff's law, resulting in a loss of bone mass through the biological process called resorption. Resorption can, in turn, cause or contribute to loosening of the prosthesis. The problem is particularly common among younger THA recipients. This study explores the hypothesis that through redesign, a total hip prosthesis can be developed to substantially reduce stress shielding. First, we describe the development of a new femoral hip prosthesis designed to alleviate this problem through a new geometry and system of proximal fixation. A numerical comparison with a conventional intramedullary prosthesis as well as another proximally fixed prosthesis, recently developed by Munting and Verhelpen (1995. Journal of Biomechanics 28(8), 949-961) is presented. The results show that the new design produces a more physiological stress state in the proximal femur.
journal_name
J Biomechjournal_title
Journal of biomechanicsauthors
Joshi MG,Advani SG,Miller F,Santare MHdoi
10.1016/s0021-9290(00)00110-xkeywords:
subject
Has Abstractpub_date
2000-12-01 00:00:00pages
1655-62issue
12eissn
0021-9290issn
1873-2380pii
S0021-9290(00)00110-Xjournal_volume
33pub_type
杂志文章abstract::Different standing postures could potentially influence trunk biomechanics during task performance. The current study investigated how foot placement, especially stance width and foot angle influenced lumbopelvic rhythm during sagittal trunk flexion motion. Ten participants performed pace controlled sagittally symmetr...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2016.03.048
更新日期:2016-06-14 00:00:00
abstract::Valgus moments on the knee joint during single-leg landing have been suggested as a risk factor for anterior cruciate ligament (ACL) injury. The purpose of this study was to test the influence of isolated valgus moment on ACL strain during single-leg landing. Physiologic levels of valgus moments from an in vivo study ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2008.10.031
更新日期:2009-02-09 00:00:00
abstract::Musculo-skeletal modeling could play a key role in advancing our understanding of the healthy and pathological spine, but the credibility of such models are strictly dependent on the accuracy of the anatomical data incorporated. In this study, we present a complete and coherent musculo-skeletal dataset for the thoraci...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2017.04.003
更新日期:2017-06-14 00:00:00
abstract::Quantifying angular joint kinematics of the upper body is a useful method for assessing upper limb function. Joint angles are commonly obtained via motion capture, tracking markers placed on anatomical landmarks. This method is associated with limitations including administrative burden, soft tissue artifacts, and int...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2018.02.028
更新日期:2018-04-27 00:00:00
abstract::This paper addresses the question of whether maximal vertical jump height depends on initial jumping posture. A direct dynamics computer simulation approach was used to avoid subject preference and practice effects. The human body was modeled as four rigid segments connected by ideal hinge joints, with movement constr...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(96)00030-9
更新日期:1996-09-01 00:00:00
abstract::External perturbations during pushing tasks have been suggested to be a risk factor for low-back symptoms. An experiment was designed to investigate whether self-induced and externally induced sudden stops while pushing a high inertia cart influence trunk motions, and how flexor and extensor muscles counteract these p...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2010.08.036
更新日期:2011-01-04 00:00:00
abstract::Many soft biological tissues possess a considerable surface stress, which plays a significant role in their biophysical functions, but most previous methods for characterizing their mechanical properties have neglected the effects of surface stress. In this work, we investigate the micropipette aspiration method to me...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2018.08.020
更新日期:2018-10-26 00:00:00
abstract::Spinal stability is related to the recruitment and control of active muscle stiffness. Stochastic system identification techniques were used to calculate the effective stiffness and dynamics of the trunk during active trunk extension exertions. Twenty-one healthy adult subjects (10 males, 11 females) wore a harness wi...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2004.09.014
更新日期:2005-10-01 00:00:00
abstract::Macroscopic structural damage to the cartilage articular surface can occur due to slicing in surgery, cracking in mechanical trauma, or fibrillation in early stage osteoarthrosis. These alterations may render cartilage matrix and chondrocytes susceptible to subsequent mechanical injury and contribute to progression of...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2005.01.026
更新日期:2006-01-01 00:00:00
abstract::The active control of the trunk plays an important role in frontal plane gait stability. We characterized trunk control in response to different step widths using a novel feedback system and examined the different effects of wide and narrow step widths as they each present unique task demands. Twenty healthy young adu...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2020.110135
更新日期:2021-01-04 00:00:00
abstract::The healing of wounds is a complex process and the contraction of the resulting scar can have a negative impact on the neighbouring skin. A finite element model of skin simulating the contraction of a scar and deformation of the surrounding skin is presented. The skin is represented by an orthotropic-viscoelastic cons...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2008.02.024
更新日期:2008-01-01 00:00:00
abstract::Several algorithms have been proposed for determining the centre of rotation of ball joints. These algorithms are used rather to locate the hip joint centre. Few studies have focused on the determination of the glenohumeral joint centre. However, no studies have assessed the accuracy and repeatability of functional me...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2009.09.029
更新日期:2010-01-19 00:00:00
abstract::Implant fixation implies a strong and durable mechanical bond between the prosthetic component and host skeleton. Assuming the short-term impediments to implant fixation are successfully addressed and that longer-term issues such as late infection and mechanical failure of the components are avoided, the biological re...
journal_title:Journal of biomechanics
pub_type: 杂志文章,评审
doi:10.1016/j.jbiomech.2014.12.021
更新日期:2015-03-18 00:00:00
abstract:OBJECTIVE:To test the force plate as a gait analysis system for broilers and to determine how the ground reaction force (GRF) patterns change in these birds with growth and administration of analgesia. MATERIALS AND METHODS:Thirty-three male Ross 308 chicks were raised on either an ad libitum or restricted-feeding reg...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2006.09.014
更新日期:2007-01-01 00:00:00
abstract::In this study, an experimental framework is described that allows pressurization of intact, human atherosclerotic carotid samples (inflation testing), in combination with ultrasound imaging. Eight fresh human carotid endarterectomy samples were successfully pressurized and tested. About 36 2-D (+t) ultrasound datasets...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2014.01.016
更新日期:2014-03-03 00:00:00
abstract::Nasal reconstruction frequently requires donor cartilage and tissue, and ideally, donor tissue will closely emulate native nasal cartilage mechanics. Tissue engineering scaffolds, especially 3D printed scaffolds, have been proposed for nasal reconstruction, and the success of these constructs may depend on how well sc...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2019.109549
更新日期:2020-02-13 00:00:00
abstract::Evaluation of postural control is generally based on the interpretation of the center of pressure (COP) and the center of mass (COM) time series. The purpose of this study is to compare three methods to estimate the COM which are based on different biomechanical considerations. These methods are: (1) the kinematic met...
journal_title:Journal of biomechanics
pub_type: 临床试验,杂志文章
doi:10.1016/S0021-9290(03)00251-3
更新日期:2004-09-01 00:00:00
abstract::In this paper the mechanical response of soft collagenous tissues with regular fiber arrangement (RSCTs) is described by means of a nanoscale model and a two-step micro-macro homogenization technique. The non-linear collagen constitutive behavior is modeled at the nanoscale by a novel approach accounting for entropic ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2009.07.040
更新日期:2010-01-19 00:00:00
abstract::Rotator cuff tears (RCTs), the most common injury of the shoulder, are often accompanied by tears in the superior glenoid labrum. We evaluated whether superior humeral head (HH) motion secondary to RCTs and loading of the long head of the biceps tendon (LHBT) are implicated in the development of this associated superi...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2014.01.036
更新日期:2014-05-07 00:00:00
abstract::The purpose of this study was to examine the age-related predictive and feedback adaptive locomotor improvements in the components of dynamic stability control during disturbed walking. Thirteen old (62-74 yrs) and ten young (23-30 yrs) male subjects performed a gait protocol on a gangway, which included one covered e...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2010.04.025
更新日期:2010-08-26 00:00:00
abstract::A new transducer was developed for in situ measurement of the force vector in a complex muscle. The transducer measures the magnitude, and the line of action of a force in a single plane. The dynamic range of the transducer is 0-5 N. This range includes the small forces developed by an active motor unit and the relati...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(96)84545-3
更新日期:1996-11-01 00:00:00
abstract::Movement variability has become an important field of research and has been studied to gain a better understanding of the neuro-muscular control of human movements. In addition to studies investigating "amplitude variability" there are a growing number of studies assessing the "temporal variability" in movements by ap...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2012.02.008
更新日期:2012-04-30 00:00:00
abstract::The purpose of this study was to determine the cross-sectional geometry and mass density distribution of a young porcine subject using the X-ray computerized tomographic (CT) method and to perform a comparative study of anatomical features of this subject and a 3 yr old female child specimen. The cross-sectional CT sc...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(83)90006-4
更新日期:1983-01-01 00:00:00
abstract::The purpose of this project was to study a noninvasive method of evaluating limbs at risk of compartment syndrome. Untreated limb compartment syndrome may lead to irreversible dysfunction, chronic pain and contracture. An improved means of obtaining quantitative hardness measurements is reported. The handheld noninvas...
journal_title:Journal of biomechanics
pub_type: 临床试验,杂志文章
doi:10.1016/j.jbiomech.2004.07.030
更新日期:2005-08-01 00:00:00
abstract::Glaucoma is a common cause of blindness. Studies of this disease can involve collection of aqueous humor (AH) fluid from eyes of patients undergoing surgery, which involves aspirating a small fluid volume from the anterior region of the eye through a fine-bore needle. Unfortunately, the composition of the AH is spatia...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2009.07.025
更新日期:2009-11-13 00:00:00
abstract::In this study, a new radiostereometric analysis (RSA) calibration cage was developed with the aim of improving the accuracy and precision of RSA. This development consisted of three steps: a numerical simulation technique was first used to design the new cage; a synthetic imaging method was then implemented to predict...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2007.11.012
更新日期:2008-01-01 00:00:00
abstract::Two questions were addressed in this study: (1) how much strain of the superficial aponeurosis of the human medial gastrocnemius muscle (MG) was obtained during voluntary isometric contractions in vivo, (2) whether there existed inhomogeneity of the strain along the superficial aponeurosis. Seven male subjects, whose ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/s0021-9290(01)00196-8
更新日期:2002-02-01 00:00:00
abstract::Measures of local dynamic stability, such as the local divergence exponent (lambda*(s)) quantify how quickly small perturbations deviate from an attractor that defines the motion. When the governing equations of motion are unknown, an attractor can be reconstructed by defining an appropriate state space. However, stat...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2009.03.015
更新日期:2009-06-19 00:00:00
abstract::Computation of muscle excitation patterns that produce coordinated movements of muscle-actuated dynamic models is an important and challenging problem. Using dynamic optimization to compute excitation patterns comes at a large computational cost, which has limited the use of muscle-actuated simulations. This paper int...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/s0021-9290(02)00432-3
更新日期:2003-03-01 00:00:00
abstract::We developed an intravaginal instrumented probe (covered with a 10×10 matrix of capacitive sensors) for assessing the three-dimensional (3D) spatiotemporal pressure profile of the vaginal canal. The pressure profile was compared to the pelvic floor (PF) digital assessment, and the reliability of the instrument and rep...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2017.04.035
更新日期:2017-06-14 00:00:00