Tensile damage and its effects on cortical bone.

Abstract:

:Plexiform bovine bone samples are repeatedly loaded in tension along their longitudinal axis. In order to induce damage in the bone tissue, bone samples are loaded past their yield point. Half of the bone samples from the damaged group were stored in saline to allow for viscoelastic recovery while the others were decalcified. Tensile tests were conducted on these samples to characterize the effects of damage on the mechanical behavior of the organic matrix (decalcified samples) as well as on bone tissue (stored in saline). The ultimate strain of the damaged decalcified bone is 29% higher compared to that of non-damaged decalcified (control) bone. The ultimate stresses as well as the elastic moduli are similar in both decalcified groups. This phenomenon is also observed in other collagenous tissue (tendon and ligament). This may suggest that damage in bone is caused by shear failure of the organic matrix; transverse separation of the collagen molecules or microfibrils from each other. In contrast, there is a trend towards lowered ultimate strains in damaged bone, which is soaked in saline, with respect to control bone samples (not damaged). The damaged bone tissue exhibits a bi-linear behavior in contrast to the mechanical behavior of non-damaged bone. The initial elastic modulus (below 55 MPa) and ultimate strength of damaged bone are similar to that in non-damaged bone.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Kotha SP,Guzelsu N

doi

10.1016/s0021-9290(03)00169-6

keywords:

subject

Has Abstract

pub_date

2003-11-01 00:00:00

pages

1683-9

issue

11

eissn

0021-9290

issn

1873-2380

pii

S0021929003001696

journal_volume

36

pub_type

杂志文章
  • Performance assessment of the Terry Fox jogging prosthesis for above-knee amputees.

    abstract::The Terry Fox jogging (TFJ) prosthesis was developed at Chedoke-McMaster Hospital to alleviate the asymmetric jogging pattern experienced by above-knee amputees when attempting to jog with conventional walking prostheses. This prosthesis features a spring-loaded, telescoping shank designed to eliminate any vaulting ac...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(89)90006-7

    authors: DiAngelo DJ,Winter DA,Ghista DN,Newcombe WR

    更新日期:1989-01-01 00:00:00

  • Experimental study of physiological pulsatile flow past valve prosthesis in a model of human aorta--II. Tilting disc valves and the effect of orientation.

    abstract::In Part II of this two paper sequence, pulsatile flow development past a tilting disc valve in a model human aorta has been studied using quantitative laser Doppler techniques. The valve was mounted in three different orientations with respect to the aortic root in this study. Under pulsatile flow, the region of flow ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(85)90052-1

    authors: Chandran KB,Khalighi B,Chen CJ

    更新日期:1985-01-01 00:00:00

  • A sensitive data analysis approach for detecting changes in dynamic postural stability.

    abstract::Understanding the mechanisms of instability can aid in reducing fall risk. As a sensitive measure of fall risk, the distance between the center of pressure (COP) and center of mass (COM) is currently assessed through discrete points assumed to represent physiological important fall mechanisms. However, it is unclear i...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109899

    authors: Moudy SC,Patterson RM,Bugnariu N

    更新日期:2020-07-17 00:00:00

  • Quantifying the history dependency of muscle recovery from a fatiguing intermittent task.

    abstract::Muscle fatigue and recovery are complex processes influencing muscle force generation capacity. While fatigue reduces this capacity, recovery acts to restore the unfatigued muscle state. Many factors can potentially affect muscle recovery, and among these may be a task dependency of recovery following an exercise. How...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.11.061

    authors: Rashedi E,Nussbaum MA

    更新日期:2017-01-25 00:00:00

  • Muscle fatigue does not lead to increased instability of upper extremity repetitive movements.

    abstract::Muscle fatigue alters neuromuscular responses. This may lead to increased sensitivity to perturbations and possibly to subsequent injury risk. We studied the effects of muscle fatigue on movement stability during a repetitive upper extremity task. Twenty healthy young subjects performed a repetitive work task, similar...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.11.001

    authors: Gates DH,Dingwell JB

    更新日期:2010-03-22 00:00:00

  • Two mathematical models explain the variation in cystometrograms of obstructed urinary bladders.

    abstract::Overdistension of the urinary bladder, secondary to outlet obstruction, causes cellular changes in the bladder wall, including hypertrophy of the smooth muscle cells, which increase bladder mass. To investigate the effects of increased mass on the cystometrogram (CMG), we have developed two mathematical models. In the...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:

    authors: Damaser MS,Lehman SL

    更新日期:1996-12-01 00:00:00

  • A method to estimate the elastic properties of the extracellular matrix of articular cartilage.

    abstract::In this work we propose a method to estimate the elastic properties of the extracellular matrix of articular cartilage, once the elastic properties of the chondrocytes and the whole tissue are known. The influence of the elastic properties of the tissue and the cell concentration on the estimated elastic properties of...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(03)00280-x

    authors: Federico S,Herzog W,Wu JZ,La Rosa G

    更新日期:2004-03-01 00:00:00

  • Use of the photoelastic method and finite element analysis in the assessment of wall strain in abdominal aortic aneurysm models.

    abstract::Abdominal aortic aneurysm (AAA) is a significant health problem. Current clinical rupture-risk relies primarily on the maximum diameter of the AAA and also growth rate. However, AAAs are a patient-specific problem and recently, numerical tools have been employed to estimate rupture-potential. Alternatively, experiment...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2012.05.004

    authors: Doyle BJ,Killion J,Callanan A

    更新日期:2012-06-26 00:00:00

  • Volume effects on fatigue life of equine cortical bone.

    abstract::Materials, including bone, often fail due to loading in the presence of critical flaws. The relative amount, location, and interaction of these flaws within a stressed volume of material play a role in determining the failure properties of the structure. As materials are generally imperfect, larger volumes of material...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.05.025

    authors: Bigley RF,Gibeling JC,Stover SM,Hazelwood SJ,Fyhrie DP,Martin RB

    更新日期:2007-01-01 00:00:00

  • Analysis of swimmers' velocity during the underwater gliding motion following grab start.

    abstract::The purpose of this study was to determine the swimmers' loss of speed during the underwater gliding motion of a grab start. This study also set out to determine the kinematical variables influencing this loss of speed. Eight French national-level swimmers participated in this study. The swimmers were filmed using 4 m...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.03.032

    authors: Elipot M,Hellard P,Taïar R,Boissière E,Rey JL,Lecat S,Houel N

    更新日期:2009-06-19 00:00:00

  • Evaluation of cross-sectional geometry and mass density distributions of humans and laboratory animals using computerized tomography.

    abstract::The purpose of this study was to determine the cross-sectional geometry and mass density distribution of a young porcine subject using the X-ray computerized tomographic (CT) method and to perform a comparative study of anatomical features of this subject and a 3 yr old female child specimen. The cross-sectional CT sc...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(83)90006-4

    authors: Huang HK,Suarez FR

    更新日期:1983-01-01 00:00:00

  • A method to determine the range of motion of the ankle joint complex, in vivo.

    abstract::The purpose of this investigation was to develop a method to quantify a range of motion of the ankle joint complex (AJC) in vivo. A six-degree-of-freedom apparatus was constructed to measure the unconstrained active range of motion of the AJC. Extensive tests evaluating the accuracy of the fixture and data collection ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(93)90614-k

    authors: Allinger TL,Engsberg JR

    更新日期:1993-01-01 00:00:00

  • Computational model of airflow in upper 17 generations of human respiratory tract.

    abstract::Computational fluid dynamics (CFD) studies of airflow in a digital reference model of the 17-generation airway (bronchial tree) were accomplished using the FLUENT computational code, based on the anatomical model by Schmidt et al. [2004. A digital reference model of the human bronchial tree. Computerized Medical Imagi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.12.019

    authors: Gemci T,Ponyavin V,Chen Y,Chen H,Collins R

    更新日期:2008-01-01 00:00:00

  • Control of cellular adhesion and myofibroblastic character with sub-micrometer magnetoelastic vibrations.

    abstract::The effect of sub-cellular mechanical loads on the behavior of fibroblasts was investigated using magnetoelastic (ME) materials, a type of material that produces mechanical vibrations when exposed to an external magnetic AC field. The integration of this functionality into implant surfaces could mitigate excessive fib...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.02.007

    authors: Holmes HR,Vlaisavljevich E,Tan EL,Snyder KL,Ong KG,Rajachar RM

    更新日期:2018-04-11 00:00:00

  • Classification of errors in locating a rigid body.

    abstract::This paper discusses the manner in which random Gaussian errors affect the determination of body segment kinematics. For the process of modelling rigid body (RB) motion, three types of kinematic errors, input, measured and theoretical, are identified. These correspond to errors in: the determination of three-dimension...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(96)00008-5

    authors: Ball KA,Pierrynowski MR

    更新日期:1996-09-01 00:00:00

  • Hospital bed height influences biomechanics during bed egress: A comparative controlled study of patients with Parkinson disease.

    abstract::Although a significant proportion of patient falls occur during egress from the hospital bed, the biomechanical adaptations during egress from different bed heights are still largely unknown. The purpose of this study was to evaluate the effect of hospital bed height on natural transition during egress in patients wit...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.110116

    authors: Xu H,Li X,Shi Y,An L,Taylor D,Christman M,Morse J,Merryweather A

    更新日期:2021-01-22 00:00:00

  • A first estimation of prestress in so-called circularly fibered osteonic lamellae.

    abstract::The existence and role of prestress in the various hierarchical structures of long bone are long standing questions. In this study, the prestress and associated strain that exist in a component of human bone microstructure, circularly fibered osteonic lamella, are estimated. Such estimates allow the formulation of hyp...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(99)00080-9

    authors: Ascenzi MG

    更新日期:1999-09-01 00:00:00

  • Surface roughness parameters as predictors of anchorage strength in bone: a critical analysis.

    abstract::The surface roughness of a bone implant was defined parametrically. The values of the parameters defining the surface were varied. Some traditionally used surface roughness parameters were calculated. By means of a theoretical model the bone-implant interfacial shear strength was estimated. No simple correlation betwe...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(00)00045-2

    authors: Hansson S

    更新日期:2000-10-01 00:00:00

  • Validation of an ambient system for the measurement of gait parameters.

    abstract::Fall risk in elderly people is usually assessed using clinical tests. These tests consist in a subjective evaluation of gait performed by healthcare professionals, most of the time shortly after the first fall occurrence. We propose to complement this one-time, subjective evaluation, by a more quantitative analysis of...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.01.024

    authors: Dubois A,Bresciani JP

    更新日期:2018-03-01 00:00:00

  • A comparison of Coulomb and pseudo-Coulomb friction implementations: Application to the table contact phase of gymnastics vaulting.

    abstract::In the table contact phase of gymnastics vaulting both dynamic and static friction act. The purpose of this study was to develop a method of simulating Coulomb friction that incorporated both dynamic and static phases and to compare the results with those obtained using a pseudo-Coulomb implementation of friction when...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.07.022

    authors: Jackson MI,Hiley MJ,Yeadon MR

    更新日期:2011-10-13 00:00:00

  • Computational modeling of neuromuscular response to swing-phase robotic knee extension assistance in cerebral palsy.

    abstract::Predicting subject-specific responses to exoskeleton assistance may aid in maximizing functional gait outcomes, such as achieving full knee-extension at foot contact in individuals with crouch gait from cerebral palsy (CP). The purpose of this study was to investigate the role of volitional and non-volitional muscle a...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.02.025

    authors: Lerner ZF,Damiano DL,Bulea TC

    更新日期:2019-04-18 00:00:00

  • In vivo human knee joint dynamic properties as functions of muscle contraction and joint position.

    abstract::Information on the dynamic properties (joint stiffness, viscosity and limb inertia) of the human knee joint is scarce in the literature, especially for actively contracting knee musculature. A joint driving device was developed to apply small-amplitude random perturbations to the human knee at several flexion angles w...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(97)00106-1

    authors: Zhang LQ,Nuber G,Butler J,Bowen M,Rymer WZ

    更新日期:1998-01-01 00:00:00

  • Regional dependency of the vascular smooth muscle cell contribution to the mechanical properties of the pig ascending aortic tissue.

    abstract:BACKGROUND:Dilation and dissection of aneurysmal ascending aortic tissues occur preferentially at the outer curvature of the vessel. In this study we hypothesize that the density and contractile properties of the vascular smooth muscle cells (VSMCs) of the pig ascending aorta (AA) are heterogeneous and could explain th...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.04.018

    authors: Tremblay D,Cartier R,Mongrain R,Leask RL

    更新日期:2010-08-26 00:00:00

  • Computational reverse shoulder prosthesis model: Experimental data and verification.

    abstract::The reverse shoulder prosthesis aims to restore the stability and function of pathological shoulders, but the biomechanical aspects of the geometrical changes induced by the implant are yet to be fully understood. Considering a large-scale musculoskeletal model of the upper limb, the aim of this study is to evaluate h...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.06.031

    authors: Martins A,Quental C,Folgado J,Ambrósio J,Monteiro J,Sarmento M

    更新日期:2015-09-18 00:00:00

  • The measurement of the variation in the surface strains of Achilles tendon grafts using imaging techniques.

    abstract::Uniaxial tensile tests are commonly used to characterize the structural and material properties of tendons and ligaments. During these tests, the stress and strain distributions applied to the specimen are assumed to be uniform. However, few studies have investigated the strain distributions throughout the tissue. The...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2004.12.021

    authors: Defrate LE,van der Ven A,Boyer PJ,Gill TJ,Li G

    更新日期:2006-01-01 00:00:00

  • A kinematic and strain gauge study of the reciprocal apparatus in the equine hind limb.

    abstract::Hind limb kinematics were recorded in five horses at walk and trot using an opto-electronic CODA-3 system. Simultaneously, in vivo strain in the completely tendinous peroneus tertius muscle was registered by implanted mercury-in-silastic strain gauges. The origin-insertion length patterns of the peroneus tertius were ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(92)90284-8

    authors: van Weeren PR,Jansen MO,van den Bogert AJ,Barneveld A

    更新日期:1992-11-01 00:00:00

  • Variability observed in mechano-regulated in vivo tissue differentiation can be explained by variation in cell mechano-sensitivity.

    abstract::Computational simulations of tissue differentiation have been able to capture the main aspects of tissue formation/regeneration observed in animal experiments-except for the considerable degree of variability reported. Understanding and modelling the source of this variability is crucial if computational tools are to ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.02.003

    authors: Khayyeri H,Checa S,Tägil M,Aspenberg P,Prendergast PJ

    更新日期:2011-04-07 00:00:00

  • Pure moment testing for spinal biomechanics applications: Fixed versus sliding ring cable-driven test designs.

    abstract::In vitro multi-axial bending testing using pure moment loading conditions has become the standard in evaluating the effects of different types of surgical intervention on spinal kinematics. Simple, cable-driven experimental set-ups have been widely adopted because they require little infrastructure. Traditionally, "fi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.02.004

    authors: Eguizabal J,Tufaga M,Scheer JK,Ames C,Lotz JC,Buckley JM

    更新日期:2010-05-07 00:00:00

  • Take-off analysis of the Olympic ski jumping competition (HS-106m).

    abstract::The take-off phase (approximately 6m) of the jumps of all athletes participating in the individual HS-106m hill ski jumping competition at the Torino Olympics was filmed with two high-speed cameras. The high altitude of the Pragelato ski jumping venue (1600m) and slight tail wind in the final jumping round were expect...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.02.026

    authors: Virmavirta M,Isolehto J,Komi P,Schwameder H,Pigozzi F,Massazza G

    更新日期:2009-05-29 00:00:00

  • Comparison of mechanical energy expenditure of joint moments and muscle forces during human locomotion.

    abstract::The mechanical energy expenditures (MEEs) of two human lower extremity models with different sources of mechanical energy - (1) muscles and (2) joint moments - were compared theoretically. Sources of mechanical energy producing movement of Model 1 were eight muscle, three of which were two-joint muscles. Sources of me...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(95)00083-6

    authors: Prilutsky BI,Petrova LN,Raitsin LM

    更新日期:1996-04-01 00:00:00