Theoretical effects of fully ductile versus fully brittle behaviors of bone tissue on the strength of the human proximal femur and vertebral body.

Abstract:

:The influence of the ductility of bone tissue on whole-bone strength represents a fundamental issue of multi-scale biomechanics. To gain insight, we performed a computational study of 16 human proximal femurs and 12 T9 vertebral bodies, comparing the whole-bone strength for the two hypothetical bounding cases of fully brittle versus fully ductile tissue-level failure behaviors, all other factors, including tissue-level elastic modulus and yield stress, held fixed. For each bone, a finite element model was generated (60-82 μm element size; up to 120 million elements) and was virtually loaded in habitual (stance for femur, compression for vertebra) and non-habitual (sideways fall, only for femur) loading modes. Using a geometrically and materially non-linear model, the tissue was assumed to be either fully brittle or fully ductile. We found that, under habitual loading, changing the tissue behavior from fully ductile to fully brittle reduced whole-bone strength by 38.3±2.4% (mean±SD) and 39.4±1.9% for the femur and vertebra, respectively (p=0.39 for site difference). These reductions were remarkably uniform across bones, but (for the femur) were greater for non-habitual (57.1±4.7%) than habitual loading (p<0.001). At overall structural failure, there was 5-10-fold less failed tissue for the fully brittle than fully ductile cases. These theoretical results suggest that the whole-bone strength of the proximal femur and vertebra can vary substantially between fully brittle and fully ductile tissue-level behaviors, an effect that is relatively insensitive to bone morphology but greater for non-habitual loading.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Nawathe S,Yang H,Fields AJ,Bouxsein ML,Keaveny TM

doi

10.1016/j.jbiomech.2015.02.066

subject

Has Abstract

pub_date

2015-05-01 00:00:00

pages

1264-9

issue

7

eissn

0021-9290

issn

1873-2380

pii

S0021-9290(15)00159-1

journal_volume

48

pub_type

杂志文章
  • Effects of follower load and rib cage on intervertebral disc pressure and sagittal plane curvature in static tests of cadaveric thoracic spines.

    abstract::The clinical relevance of mechanical testing studies of cadaveric human thoracic spines could be enhanced by using follower preload techniques, by including the intact rib cage, and by measuring thoracic intervertebral disc pressures, but studies to date have not incorporated all of these components simultaneously. Th...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.02.038

    authors: Anderson DE,Mannen EM,Sis HL,Wong BM,Cadel ES,Friis EA,Bouxsein ML

    更新日期:2016-05-03 00:00:00

  • Comparison of shear forces and ligament loading in the healthy and ACL-deficient knee during gait.

    abstract::The purpose of this study was to predict and explain the pattern of shear force and ligament loading in the ACL-deficient knee during walking, and to compare these results to similar calculations for the healthy knee. Musculoskeletal modeling and computer simulation were combined to calculate ligament forces in the AC...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2003.07.001

    authors: Shelburne KB,Pandy MG,Torry MR

    更新日期:2004-03-01 00:00:00

  • Two mathematical models explain the variation in cystometrograms of obstructed urinary bladders.

    abstract::Overdistension of the urinary bladder, secondary to outlet obstruction, causes cellular changes in the bladder wall, including hypertrophy of the smooth muscle cells, which increase bladder mass. To investigate the effects of increased mass on the cystometrogram (CMG), we have developed two mathematical models. In the...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:

    authors: Damaser MS,Lehman SL

    更新日期:1996-12-01 00:00:00

  • The impact of boundary conditions on surface curvature of polypropylene mesh in response to uniaxial loading.

    abstract::Exposure following pelvic organ prolapse repair has been observationally associated with wrinkling of the implanted mesh. The purpose of this study was to quantify the impact of variable boundary conditions on the out-of-plane deformations of mesh subjected to tensile loading. Using photogrammetry and surface curvatur...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.02.061

    authors: Barone WR,Amini R,Maiti S,Moalli PA,Abramowitch SD

    更新日期:2015-06-25 00:00:00

  • Microcrack growth parameters for compact bone deduced from stiffness variations.

    abstract::This paper shows how information on the fatigue behaviour of microcracks can be obtained by the analysis of stiffness changes measured during cyclic loading. Relationships between crack length, growth rate and cyclic stress intensity were deduced, and compared with previous empirical equations. Results show that the c...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(98)00050-5

    authors: Taylor D

    更新日期:1998-07-01 00:00:00

  • Kinematic analysis of video-captured falls experienced by older adults in long-term care.

    abstract::Falls cause 95% of hip and wrist fractures and 60% of head injuries in older adults. Risk for such injuries depends in part on velocity at contact, and the time available during the fall to generate protective responses. However, we have no information on the impact velocities and durations of falls in older adults. W...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.02.025

    authors: Choi WJ,Wakeling JM,Robinovitch SN

    更新日期:2015-04-13 00:00:00

  • Influence of curvature dynamics on pulsatile coronary artery flow in a realistic bifurcation model.

    abstract::The coronary arteries undergo large dynamic variations during each cardiac cycle due to their position on the beating heart. The local artery curvature varies significantly. In this study the influence of dynamic curvature on coronary artery hemodynamics is analyzed numerically. A realistic model of the bifurcation of...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2004.01.021

    authors: Prosi M,Perktold K,Ding Z,Friedman MH

    更新日期:2004-11-01 00:00:00

  • Dynamics of the human masticatory muscles during a jaw open-close movement.

    abstract::The movements of the human jaw are controlled by the forces produced by the masticatory muscles. As the jaw moves, these muscles change in length and their force producing units, the sarcomeres, change in length simultaneously. The lengths and length changes of the sarcomeres are determinants for the forces they are a...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(97)00047-x

    authors: Koolstra JH,van Eijden TM

    更新日期:1997-09-01 00:00:00

  • The effects of groove height and substrate stiffness on C. elegans locomotion.

    abstract::The physical environment surrounding an animal has a significant impact on its behavior. The nematode Caenorhabditis elegans (C. elegans) has proved to be an excellent choice for understanding the adaptability of organisms crawling on soft surfaces. In this work, we investigate the modulation of C. elegans' behavioral...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.02.015

    authors: Parida L,Ghosh UU,Padmanabhan V

    更新日期:2017-04-11 00:00:00

  • Concurrent repeatability and reproducibility analyses of four marker placement protocols for the foot-ankle complex.

    abstract::Multi-segment models of the foot have been proposed in the past years to overcome limitations imposed by oversimplified traditional approaches used to describe foot kinematics, but they have been only partially validated and never compared. This paper presents a unique comparative assessment of the four most widely ad...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.07.041

    authors: Di Marco R,Rossi S,Racic V,Cappa P,Mazzà C

    更新日期:2016-10-03 00:00:00

  • Ulceration, unsteadiness, and uncertainty: the biomechanical consequences of diabetes mellitus.

    abstract::Diabetes mellitus, which results from a failure of the endocrine system to control blood glucose levels within normal limits, affects approximately 15% of the population over the age of 65 in developed countries. Between 20-50% of people with diabetes for more than 10 years will experience symmetrical distal sensory n...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章,评审

    doi:10.1016/0021-9290(93)90077-r

    authors: Cavanagh PR,Simoneau GG,Ulbrecht JS

    更新日期:1993-01-01 00:00:00

  • Chest response assessment of post-mortem swine under blast loadings.

    abstract::To better protect soldiers from blast threat, that principally affect air-filled organs such a lung, it is necessary to develop an adapted injury criterion and, prior to this, to evaluate the response of a biological model against that threat. The objective of this study is to provide some robust data to quantify the ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.10.012

    authors: Boutillier J,De Mezzo S,Deck C,Magnan P,Naz P,Willinger R

    更新日期:2017-12-08 00:00:00

  • Coping with perturbations to a layout somersault in tumbling.

    abstract::Tumbling is a dynamic movement requiring control of the linear and angular momenta generated during the approach and takeoff phases. Both of these phases are subject to some variability even when the gymnast is trying to perform a given movement repeatedly. This paper used a simulation model of tumbling takeoff to est...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(03)00077-0

    authors: King MA,Yeadon MR

    更新日期:2003-07-01 00:00:00

  • Novel instrumented probe for measuring 3D pressure distribution along the vaginal canal.

    abstract::We developed an intravaginal instrumented probe (covered with a 10×10 matrix of capacitive sensors) for assessing the three-dimensional (3D) spatiotemporal pressure profile of the vaginal canal. The pressure profile was compared to the pelvic floor (PF) digital assessment, and the reliability of the instrument and rep...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.04.035

    authors: Cacciari LP,Pássaro AC,Amorim AC,Geuder M,Sacco ICN

    更新日期:2017-06-14 00:00:00

  • The influence of ligament modelling strategies on the predictive capability of finite element models of the human knee joint.

    abstract::In finite element (FE) models knee ligaments can represented either by a group of one-dimensional springs, or by three-dimensional continuum elements based on segmentations. Continuum models closer approximate the anatomy, and facilitate ligament wrapping, while spring models are computationally less expensive. The me...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.08.030

    authors: Naghibi Beidokhti H,Janssen D,van de Groes S,Hazrati J,Van den Boogaard T,Verdonschot N

    更新日期:2017-12-08 00:00:00

  • Biotribology of a mobile bearing posterior stabilised knee design--effect of motion restraint on wear, tibio-femoral kinematics and particles.

    abstract::The objective of our study was to evaluate the impact of a biphaseal anterior-posterior (AP) and internal-external (IE) motion restraint system on the wear behaviour, tibio-femoral kinematics and particle release of a mobile bearing posterior stabilised knee design in comparison to the widely used linear restraint. in...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.04.020

    authors: Grupp TM,Schroeder C,Kyun Kim T,Miehlke RK,Fritz B,Jansson V,Utzschneider S

    更新日期:2014-07-18 00:00:00

  • Challenges in relating experimental hip implant fixation predictions to clinical observations.

    abstract::Long-term clinical follow-up studies have shown that radiolucent lines at the cement interfaces of total hip replacement femoral components develop gradually, ultimately leading to loosening. In this experimental study, 32 synthetic femurs implanted with cemented femoral components were cyclically loaded with a dynami...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.10.006

    authors: Sangiorgio SN,Longjohn DB,Dorr LD,Ebramzadeh E

    更新日期:2011-01-11 00:00:00

  • Model of muscle-tendon interaction during frog semitendinosis fixed-end contractions.

    abstract::A structural model was developed to explain sarcomere shortening at the expense of tendon lengthening in the frog semitendinosis (ST) muscle-tendon system. The model was based on the data of Lieber et al. [Am. J. Physiol. 261, C86-C92 (1991)], who determined the relationship between the sarcomere length, tendon load (...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(92)90261-x

    authors: Lieber RL,Brown CG,Trestik CL

    更新日期:1992-04-01 00:00:00

  • Microscale frictional response of bovine articular cartilage from atomic force microscopy.

    abstract::The objective of this study was to compare micro- and macroscale friction coefficients of bovine articular cartilage. Microscale measurements were performed using standard atomic force microscopy (AFM) techniques, using a 5 microm spherical probe tip. Twenty-four cylindrical osteochondral plugs were harvested in pairs...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2004.02.017

    authors: Park S,Costa KD,Ateshian GA

    更新日期:2004-11-01 00:00:00

  • 3D printed clamps improve spine specimen fixation in biomechanical testing.

    abstract::This study presents an anatomically customizable fixation technique for biomechanical spine experiments using a 3D printed clamping system. The aim of this study is to evaluate the feasibility and compare the fixation rigidity of the novel technique to PMMA potting with and without screw augmentation. For this purpose...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.109467

    authors: Cornaz F,Fasser MR,Spirig JM,Snedeker JG,Farshad M,Widmer J

    更新日期:2020-01-02 00:00:00

  • Effect of geometrical imperfections in confined compression tests on parameter evaluation of hydrated soft tissues.

    abstract::Experimental tests, such as the confined and unconfined compression and the indentation tests, are traditionally used to determine the poroelastic properties of hydrated soft tissues (HSTs). The purpose of this study was to quantitatively evaluate the reliability of H(A) and K values as identified from experimental co...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.02.020

    authors: Gervaso F,Pennati G,Boschetti F

    更新日期:2007-01-01 00:00:00

  • Non-linear rotation-free shell finite-element models for aortic heart valves.

    abstract::Hyperelastic material models have been incorporated in the rotation-free, large deformation, shell finite element (FE) formulation of (Stolarski et al., 2013) and applied to dynamic simulations of aortic heart valve. Two models used in the past in analysis of such problem i.e. the Saint-Venant and May-Newmann-Yin (MNY...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.11.031

    authors: Gilmanov A,Stolarski H,Sotiropoulos F

    更新日期:2017-01-04 00:00:00

  • Biomechanical effect of rapid mucoperiosteal palatal tissue expansion with the use of osmotic expanders.

    abstract::The comparative study was performed to investigate the biomechanical properties (maximum tangential stiffness, maximum tangential modulus and tensile strength) of expanded mucoperiosteal palatal tissue after rapid expansion regimen correlated with histological findings. Rabbit palatal model was used to correlate the n...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.01.012

    authors: Wysocki M,Kobus K,Szotek S,Kobielarz M,Kuropka P,Będziński R

    更新日期:2011-04-29 00:00:00

  • Active axial stress in mouse aorta.

    abstract::The study verifies the development of active axial stress in the wall of mouse aorta over a range of physiological loads when the smooth muscle cells are stimulated to contract. The results obtained show that the active axial stress is virtually independent of the magnitude of pressure, but depends predominately on th...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2012.05.025

    authors: Agianniotis A,Rachev A,Stergiopulos N

    更新日期:2012-07-26 00:00:00

  • Construction of healthy arteries using computed tomography and virtual histology intravascular ultrasound.

    abstract::Vessel geometry for numerical analysis is generally obtained by computed tomography (CT) or magnetic resonance imaging (MRI) and intravascular ultrasound (IVUS). Most medical imaging is obtained from patients for hemodynamic analysis due to the properties of vascular disease and the difficulties in angiography. To pre...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2012.04.003

    authors: Ryou HS,Kim S,Kim SW,Cho SW

    更新日期:2012-06-01 00:00:00

  • EMG and force production of some human shoulder muscles during isometric abduction.

    abstract::Surface EMG was recorded in four subjects on three different occasions from the three parts of the deltoid, the clavicular part of the pectoralis major and from the infraspinatus muscles at different angles of abduction, in the frontal and scapular plane. The integrated EMG was related to the maximum values found for ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(85)90037-5

    authors: Ringelberg JA

    更新日期:1985-01-01 00:00:00

  • Functional imaging using computational fluid dynamics to predict treatment success of mandibular advancement devices in sleep-disordered breathing.

    abstract::Mandibular advancement devices (MADs) have emerged as a popular alternative for the treatment of sleep-disordered breathing. These devices bring the mandibula forward in order to increase upper airway (UA) volume and prevent total UA collapse during sleep. However, the precise mechanism of action appears to be quite c...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.jbiomech.2007.06.022

    authors: De Backer JW,Vanderveken OM,Vos WG,Devolder A,Verhulst SL,Verbraecken JA,Parizel PM,Braem MJ,Van de Heyning PH,De Backer WA

    更新日期:2007-01-01 00:00:00

  • Introduction of dynamic rate-of-force development scaling factor in progressive drop jumps.

    abstract::Rapid force generation across submaximal levels has been evaluated with the rate of force development scaling factor (RFD-SF) in different isometric tasks, while such measurement was still not verified in dynamic tasks. Our study was designed to evaluate the feasibility of the RFD-SF in dynamic drop jump (DJ) task (RF...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109980

    authors: Šarabon N,Knezevic MO,Mirkov MD,Smajla D

    更新日期:2020-09-18 00:00:00

  • Differences in 3D vs. 2D analysis in lumbar spinal fusion simulations.

    abstract::Lumbar interbody fusion is currently the gold standard in treating patients with disc degeneration or segmental instability. Despite it having been used for several decades, the non-union rate remains high. A failed fusion is frequently attributed to an inadequate mechanical environment after instrumentation. Finite e...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.03.009

    authors: Hsu HW,Bashkuev M,Pumberger M,Schmidt H

    更新日期:2018-04-27 00:00:00

  • Optimal design parameters of the bicycle-rider system for maximal muscle power output.

    abstract::The purpose of this study was to find the optimal values of design parameters for a bicycle-rider system (crank length, pelvic inclination, seat height, and rate of crank rotation) which maximize the power output from muscles of the human lower limb during bicycling. The human lower limb was modelled as a planar syste...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(90)90322-t

    authors: Yoshihuku Y,Herzog W

    更新日期:1990-01-01 00:00:00