Abstract:
:Numerical models commonly account for elastic inhomogeneity in cortical bone using power-law scaling relationships with various measures of tissue density, but limited experimental data exists for anatomic variation in elastic anisotropy. A recent study revealed anatomic variation in the magnitude and anisotropy of elastic constants along the entire femoral diaphysis of a single human femur (Espinoza Orías et al., 2009). The objective of this study was to confirm these trends across multiple donors while also considering possible confounding effects of the anatomic quadrant, apparent tissue density, donor age, and gender. Cortical bone specimens were sampled from the whole femora of 9 human donors at 20%, 50%, and 80% of the total femur length. Elastic constants from the main diagonal of the reduced fourth-order tensor were measured on hydrated specimens using ultrasonic wave propagation. The tissue exhibited orthotropy overall and at each location along the length of the diaphysis (p < 0.0001). Elastic anisotropy increased from the mid-diaphysis toward the epiphyses (p < 0.05). The increased elastic anisotropy was primarily caused by a decreased radial elastic constant (C(11)) from the mid-diaphysis toward the epiphyses (p < 0.05), since differences in the circumferential (C(22)) and longitudinal (C(33)) elastic constants were not statistically significant (p > 0.29). Anatomic variation in intracortical porosity may account for these trends, but requires further investigation. The apparent tissue density was positively correlated with the magnitude of each elastic constant (p < 0.0001, R(2) > 0.46), as expected, but was only weakly correlated with C(33)/C(11) (p < 0.05, R(2) = 0.04) and not significantly correlated with C(33)/C(22) and C(11)/C(22).
journal_name
J Biomechjournal_title
Journal of biomechanicsauthors
Rudy DJ,Deuerling JM,Espinoza Orías AA,Roeder RKdoi
10.1016/j.jbiomech.2011.04.009subject
Has Abstractpub_date
2011-06-03 00:00:00pages
1817-20issue
9eissn
0021-9290issn
1873-2380pii
S0021-9290(11)00314-9journal_volume
44pub_type
杂志文章abstract::The accumulation of a fluid property from the standpoint of a particle moving with non-steady fluid flow (i.e., platelet/blood-cell damage index in pulsating blood flow) is a challenged computational problem due to the current need for particle-tracing methods. The method we developed (dubbed VPI) enables the approxim...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2009.11.011
更新日期:2010-03-22 00:00:00
abstract::Movement variability has become an important field of research and has been studied to gain a better understanding of the neuro-muscular control of human movements. In addition to studies investigating "amplitude variability" there are a growing number of studies assessing the "temporal variability" in movements by ap...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2012.02.008
更新日期:2012-04-30 00:00:00
abstract::The mechanical energy expenditures (MEEs) of two human lower extremity models with different sources of mechanical energy - (1) muscles and (2) joint moments - were compared theoretically. Sources of mechanical energy producing movement of Model 1 were eight muscle, three of which were two-joint muscles. Sources of me...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(95)00083-6
更新日期:1996-04-01 00:00:00
abstract::Polymeric stents can be considered as an alternative to metallic stents thanks to their lessened incidence of restenosis and controlled deployment. The purpose of this study was to investigate the feasibility of developing a temperature-responsive braided stent using shape memory polyurethane (SMPU) through finite ele...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2009.10.032
更新日期:2010-03-03 00:00:00
abstract::We developed a computational model of lung parenchyma, which is comprised of individual alveolar chamber models. Each alveolus is modeled by a truncated octahedron. Considering the force balance between the elastin and collagen fibers laying on the alveolar membrane and the pressures acting on the membrane, we compute...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2012.11.031
更新日期:2013-01-18 00:00:00
abstract::To improve the treatments for low back pain, new designs of total disk replacement have been proposed. The question is how well these designs can act as a functional replacement of the intervertebral disk. Four finite element models were made, for four different design concepts, to determine how well they can mimic th...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2011.09.017
更新日期:2012-01-03 00:00:00
abstract::Motion capture systems currently used in biomechanical analysis introduce systematic measurement errors that appear in the form of noise in recorded displacement signals. The noise is unacceptably amplified when differentiating displacements to obtain velocities and accelerations. To avoid this phenomenon, it is neces...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2004.05.031
更新日期:2005-05-01 00:00:00
abstract::The objective of the current study was to use fluoroscopy to accurately determine the three-dimensional (3D), in vivo, weight-bearing kinematics of 10 normal and five anterior cruciate ligament deficient (ACLD) knees. Patient-specific bone models were derived from computed tomography (CT) data. 3D computer bone models...
journal_title:Journal of biomechanics
pub_type: 临床试验,杂志文章
doi:10.1016/j.jbiomech.2004.02.042
更新日期:2005-02-01 00:00:00
abstract::Mandibular advancement splints (MAS), which protrude the lower jaw during sleep, are recognized as an effective treatment for obstructive sleep apnea (OSA) through their action of enlarging the airway space and preventing upper airway collapse. However a clinical challenge remains in preselecting patients who will res...
journal_title:Journal of biomechanics
pub_type: 临床试验,杂志文章
doi:10.1016/j.jbiomech.2012.10.033
更新日期:2013-01-04 00:00:00
abstract::None of the physical testing, nor the goniometers currently used to assess upper limb function have a high validity, sensitivity or reliability. The reachable workspace, i.e. the area covered by the farthest points a subject can reach by hand without moving his/her body, shows promise but has yet to be validated, part...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2017.12.010
更新日期:2018-02-08 00:00:00
abstract::2D, coronal plane, finite elements models (FEMs) were developed from orthogonal radiographs of a diaphyseal tibial fracture and its reparative tissue at four different time points during healing. Each callus was separated into regions of common tissue histology by computerised radiographic analysis. Starting point val...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/s0021-9290(99)00189-x
更新日期:2000-04-01 00:00:00
abstract::Risk for injury during a fall depends on the position and velocity of the body segments at the moment of impact. One technique for reducing impact velocity is to absorb energy in the lower extremity muscles during descent, as occurs during squatting or sitting. However, the protective value of this response may depend...
journal_title:Journal of biomechanics
pub_type: 临床试验,杂志文章
doi:10.1016/j.jbiomech.2003.12.015
更新日期:2004-09-01 00:00:00
abstract::Aggregation of highly deformable red blood cells (RBCs) significantly affects the blood flow in the human circulatory system. To investigate the effect of deformation and aggregation of RBCs in blood flow, a mathematical model has been established by coupling the interaction between the fluid and the deformable solids...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2013.05.010
更新日期:2013-07-26 00:00:00
abstract::The Terry Fox jogging (TFJ) prosthesis was developed at Chedoke-McMaster Hospital to alleviate the asymmetric jogging pattern experienced by above-knee amputees when attempting to jog with conventional walking prostheses. This prosthesis features a spring-loaded, telescoping shank designed to eliminate any vaulting ac...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(89)90006-7
更新日期:1989-01-01 00:00:00
abstract::This contribution is concerned with the modelling of PMMA-based bone cement polymerisation process and the associated heat effect. While existing models use description in terms of the so-called polymerisation fraction to fit the experimental data, the new model is constructed in such a way as to mimic the chemical pr...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2004.06.021
更新日期:2005-07-01 00:00:00
abstract::The present numerical study aims to investigate the disc nutrition and factors affecting it by evaluating the concentrations of oxygen, glucose and lactic acid in the disc while accounting for the coupling between these species via the pH level in the tissue and the nonlinear concentration-consumption (for glucose and...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2007.01.003
更新日期:2007-01-01 00:00:00
abstract::We studied the mechanical and anatomical anisotropy of the canine diaphragmatic central tendon (CT). Dumb-bell-shaped strips with effective dimensions of 10 x 2 mm (length x width) were cut from different regions of the canine diaphragmatic CT in two different orientations relative to the direction of neighboring musc...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(91)90289-y
更新日期:1991-01-01 00:00:00
abstract::The purpose of this study was to devise a method for the tensile testing of the organic component of demineralised bone. It was hoped that the method could be applied to determine whether an observed reduction in the strength of bone in copper-deficient rats could be attributed to a reduction in the cross-linking of c...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(93)90365-l
更新日期:1993-03-01 00:00:00
abstract::Bone is subjected in vivo to both high amplitude, low frequency strain, incurred by locomotion, and to low amplitude, broad frequency strain. The biological effects of low amplitude, broad frequency strain are poorly understood. To evaluate the effects of low amplitude strains ranging in frequency from 0 to 50 Hz on o...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/s0021-9290(02)00245-2
更新日期:2003-01-01 00:00:00
abstract::The purpose of this study was to investigate the effects of a total-contact insole with and without subthreshold mechanical random noise on the balance control in diabetic patients with mild-to-moderate peripheral neuropathy. Twenty diabetic patients with mild-to-moderate neuropathy was recruited to this study. A tota...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2020.109656
更新日期:2020-04-16 00:00:00
abstract::Formation of restrictive adhesions is one of the main obstacles in rehabilitation following hand surgery. Most experimental work, however, involves only a macroscopic and/or histologic evaluation of the amount of adhesions, and their functional characteristics are poorly described. The aim of this study was to develop...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(91)90171-i
更新日期:1991-01-01 00:00:00
abstract::In order to assess the potential influence of various physical or chemical treatments on bone grafts, and in particular, on femoral heads to be used as bone grafts, the mechanical symmetry of the femoral head was investigated. Pairs of proximal human femora were harvested and transversally sliced using a coordinate sy...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(96)00061-9
更新日期:1996-10-01 00:00:00
abstract::Hand-arm vibration (HAV) models serve as an effective tool to assess the vibration characteristics of the hand-tool system and to evaluate the attenuation performance of vibration isolation mechanisms. This paper describes a methodology to identify the parameters of HAV models, whether linear or nonlinear, using mecha...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(93)90073-n
更新日期:1993-10-01 00:00:00
abstract::The use of a finite element based computational method, RFEM3D, is described for the study of strain-induced bone remodeling. The purpose of the research is to find the potential influence on the predictions of surface bone remodeling when various models for the maturation of newly deposited bone are used. A parameter...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(90)90015-u
更新日期:1990-01-01 00:00:00
abstract::A squeeze-film lubrication model of the human ankle joint in standing that takes into account the fluid transport across the articular surface is presented. Articular cartilage is a biphasic mixture of the ideal interstitial fluid and an elastic permeable isotropic homogeneous intrinsically incompressible matrix. The ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/s0021-9290(00)00109-3
更新日期:2000-11-01 00:00:00
abstract::The effect of stress deprivation on the tendon tissue has been an important focus in the field of biomechanics. However, less is known about the in vivo effect of stress deprivation on fibroblast apoptosis as of yet. This study was conducted to test a hypothesis that complete stress deprivation of the patellar tendon ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2009.07.027
更新日期:2009-11-13 00:00:00
abstract::Trabecular bone is viscoelastic under dynamic loading. However, it is unclear how tissue viscoelasticity controls viscoelasticity at the apparent-level. In this study, viscoelasticity of cylindrical human trabecular bone samples (n=11, male, age 18-78 years) from 11 proximal femurs were characterized using dynamic and...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2017.10.002
更新日期:2017-12-08 00:00:00
abstract::A pair of finite element models has been employed to study the interaction of blood flow with the operation of the aortic valve. A three-dimensional model of the left ventricle with applied wall displacements has been used to generate data for the spatially and time-varying blood velocity profile across the aortic ape...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2004.10.038
更新日期:2006-01-01 00:00:00
abstract::Subject-specific musculoskeletal models require accurate values of muscle moment arms. The aim of this study was to compare moment arms of wrist tendons obtained from non-invasive magnetic resonance imaging (MRI) to those obtained from an in vitro experimental approach. MRI was performed on ten upper limb cadaveric sp...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2017.12.024
更新日期:2018-02-08 00:00:00
abstract::Animal models of ventricular tachypacing (VTP) have been successfully used to reproduce the relevant features observed in patients with atrial fibrillation, such as increased atrial pressure and volume, ion-channel alterations and fibrosis. After performing VTP on a healthy Yorkshire pig, we measured an increase in vo...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2011.09.003
更新日期:2011-11-10 00:00:00