On the importance of blood rheology for bulk flow in hemodynamic models of the carotid bifurcation.

Abstract:

:Here we present a study on the impact of assumptions on image-based hemodynamic simulations of healthy carotid bifurcations. In particular, we evaluate to which extent assumptions on blood rheology influence bulk flow features, driven by the fact that few studies have provided adequate insights into the influence of assumptions to confidently model the 4D hemodynamics within the bifurcation. The final goal is to complement, integrate and extend with a quantitative characterization of the bulk flow the description currently adopted to classify altered hemodynamics, which is based on wall shear stress (WSS). Hemodynamic simulations of two image-based carotid bifurcation geometries were carried out assuming a reference Newtonian viscosity, two non-Newtonian rheology models and Newtonian viscosities based on characteristic shear rates. WSS-based and Lagrangian-based metrics for helical flow quantification and for vorticity dynamics quantification were calculated. Our findings suggest that the assumption of Newtonian rheology: (1) could be reasonable for bulk flow metrics (differences from non-Newtonian behavior are lower than 10%); (2) influences at different levels the WSS-based indicators, depending on the bifurcation model, even if in our study it is lower than the major source of uncertainty as recognized by the literature (i.e., uncertainty on geometry reconstruction).

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Morbiducci U,Gallo D,Massai D,Ponzini R,Deriu MA,Antiga L,Redaelli A,Montevecchi FM

doi

10.1016/j.jbiomech.2011.06.028

subject

Has Abstract

pub_date

2011-09-02 00:00:00

pages

2427-38

issue

13

eissn

0021-9290

issn

1873-2380

pii

S0021-9290(11)00478-7

journal_volume

44

pub_type

杂志文章
  • Spatial phenotyping of the endocardial endothelium as a function of intracardiac hemodynamic shear stress.

    abstract::Despite substantial evidence for the central role of hemodynamic shear stress in the functional integrity of vascular endothelial cells, hemodynamic and molecular regulation of the endocardial endothelium lining the heart chambers remains understudied. We propose that regional differences in intracardiac hemodynamics ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.11.018

    authors: McCormick ME,Manduchi E,Witschey WRT,Gorman RC,Gorman JH 3rd,Jiang YZ,Stoeckert CJ Jr,Barker AJ,Yoon S,Markl M,Davies PF

    更新日期:2017-01-04 00:00:00

  • PDGF-BB, IGF-I and mechanical load stimulate DNA synthesis in avian tendon fibroblasts in vitro.

    abstract::Resident cells in the surface epitenon and internal compartment of flexor tendons are subjected to cyclic mechanical load as muscle contracts to move limbs or digits. Tendons are largely tensile load bearing tissues and are highly matrix intensive with nondividing cells providing maintenance functions. However, when a...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(95)00098-4

    authors: Banes AJ,Tsuzaki M,Hu P,Brigman B,Brown T,Almekinders L,Lawrence WT,Fischer T

    更新日期:1995-12-01 00:00:00

  • Velocities and stress levels of axisymmetric, azimuthal flow within the toroidal rotary seal of the IBM 2997 continuous flow cell separator and the implications.

    abstract::Continuous flow blood fraction separators are used to facilitate the removal of specific blood components for donation or for certain medical procedures. Problems with one such device, the IBM 2997 Blood Processor, have been noted in a number of independent investigations. A key feature of this particular unit is a ce...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(86)90163-6

    authors: Harvey CB,O'Rear EA

    更新日期:1986-01-01 00:00:00

  • Effect of variable periodontal ligament thickness and its non-linear material properties on the location of a tooth's centre of resistance.

    abstract::In orthodontics, the 3D translational and rotational movement of a tooth is determined by the force-moment system applied and the location of the tooth's centre of resistance (CR). Because of the practical constraints of in-vivo experiments, the finite element (FE) method is commonly used to determine the CR. The obje...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.07.043

    authors: Schmidt F,Lapatki BG

    更新日期:2019-09-20 00:00:00

  • Adversarial autoencoder for visualization and classification of human activity: Application to a low-cost commercial force plate.

    abstract::The ability to visualize and interpret high dimensional time-series data will be critical as wearable and other sensors are adopted in rehabilitation protocols. This study proposes a latent space representation of high dimensional time-series data for data visualization. For that purpose, a deep learning model called ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109684

    authors: Hernandez V,Kulić D,Venture G

    更新日期:2020-04-16 00:00:00

  • Mechanical properties of double-stranded DNA biolayers immobilized on microcantilever under axial compression.

    abstract::In label-free biodetections based on microcantilever technology, double-stranded DNA (dsDNA) structures form through the linkage between probe single-stranded DNA (ssDNA) molecules immobilized on solid substrates and target ssDNA molecules in solutions. Mechanical/electrical properties of these biolayers are important...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.03.050

    authors: Zhang NH,Chen JZ

    更新日期:2009-07-22 00:00:00

  • A linearized formulation of triphasic mixture theory for articular cartilage, and its application to indentation analysis.

    abstract::The negative charges on proteoglycans significantly affect the mechanical behaviors of articular cartilage. Mixture theories, such as the triphasic theory, can describe quantitatively how this charged nature contributes to the mechano-electrochemical behaviors of such tissue. However, the mathematical complexity of th...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.10.026

    authors: Lu XL,Wan LQ,Guo XE,Mow VC

    更新日期:2010-03-03 00:00:00

  • Effect of metal and sampling rate on accuracy of Flock of Birds electromagnetic tracking system.

    abstract::Electromagnetic tracking devices are used in many biomechanics applications. Previous studies have shown that metal located within the working field of direct current electromagnetic tracking devices produces significant errors. However, the effect of sampling rate on the errors produced in a metallic environment has ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(02)00322-6

    authors: LaScalza S,Arico J,Hughes R

    更新日期:2003-01-01 00:00:00

  • The accuracy of magnetic resonance phase velocity measurements in stenotic flow.

    abstract::Nuclear magnetic resonance (MR) can be used to measure velocities in fluid flow using the technique of phase velocity mapping. Advantages of MR velocimetry include the simultaneous mapping of the entire flow field through a non-contacting, magnetic window. The phase velocity mapping technique assumes that velocity is ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:

    authors: Siegel JM Jr,Oshinski JN,Pettigrew RI,Ku DN

    更新日期:1996-12-01 00:00:00

  • Insufficient accuracy of the ultrasound-based determination of Achilles tendon cross-sectional area.

    abstract::The accurate assessment of the Achilles tendon cross-sectional area (CSA) is a crucial prerequisite to investigate tendon adaptation and to calculate the tendon Young׳s modulus. Besides magnetic resonance imaging (MRI), ultrasonography emerged as an alternative imaging technique. The purpose of the present study was t...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.07.002

    authors: Bohm S,Mersmann F,Schroll A,Mäkitalo N,Arampatzis A

    更新日期:2016-09-06 00:00:00

  • Circumferentially flexible vascular grafts.

    abstract::An arterial graft with a corrugated cylindrical cross-section has been proposed as a partial solution to the problem of elastic stiffness mismatch between conventional grafts and arterial tissue (Trescony et al., 1994, US Patent 5,282, 847 (granted February 1 1994)). A two-dimensional ring theory model and a finite el...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(98)00084-0

    authors: Stump DM,Hart VG,Tuttle SL

    更新日期:1998-08-01 00:00:00

  • Mass properties of the human mandible.

    abstract::Computer simulation of human masticatory dynamics requires specification of the jaw's mass properties. These are difficult to estimate, especially in living subjects. Here, we used calibrated computed tomography (CT) to determine the properties of eight osseous jaw specimens with adult dentitions. When the CT numbers ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(02)00057-x

    authors: Zhang F,Peck CC,Hannam AG

    更新日期:2002-07-01 00:00:00

  • High-acceleration whole body vibration stimulates cortical bone accrual and increases bone mineral content in growing mice.

    abstract::Whole body vibration (WBV) is a promising tool for counteracting bone loss. Most WBV studies on animals have been performed at acceleration <1g and frequency between 30 and 90Hz. Such WBV conditions trigger bone growth in osteopenia models, but not in healthy animals. In order to test the ability of WBV to promote ost...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.04.031

    authors: Gnyubkin V,Guignandon A,Laroche N,Vanden-Bossche A,Malaval L,Vico L

    更新日期:2016-06-14 00:00:00

  • Suitability of Kinect for measuring whole body movement patterns during exergaming.

    abstract::Exergames provide a challenging opportunity for home-based training and evaluation of postural control in the elderly population, but affordable sensor technology and algorithms for assessment of whole body movement patterns in the home environment are yet to be developed. The aim of the present study was to evaluate ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.07.017

    authors: van Diest M,Stegenga J,Wörtche HJ,Postema K,Verkerke GJ,Lamoth CJ

    更新日期:2014-09-22 00:00:00

  • Shoe midsole hardness, sex and age effects on lower extremity kinematics during running.

    abstract::Previous studies investigating the effects of shoe midsole hardness on running kinematics have often used male subjects from within a narrow age range. It is unknown whether shoe midsole hardness has the same kinematic effect on male and female runners as well as runners from different age categories. As sex and age h...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.jbiomech.2012.03.027

    authors: Nigg BM,Baltich J,Maurer C,Federolf P

    更新日期:2012-06-01 00:00:00

  • A new approach for surface fitting method of articular joint surfaces.

    abstract::The application of joint contact mechanics requires a precise configuration of the joint surfaces. B-Spline, and NURBS have been widely used to model joint surfaces, but because these formulations use a structured data set provided by a rectangular net first, then a grid, there is a limit to the accuracy of the models...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2004.01.009

    authors: Hirokawa S,Ueki T,Ohtsuki A

    更新日期:2004-10-01 00:00:00

  • Reconstruction of proximal humeral fractures without screws using a reinforced bone substitute.

    abstract::Multi-fragment fractures are still a challenge: current clinical practice relies on plates and screws. Treatment of fractures of the proximal humerus has the intra-operative risk of articular damage when inserting multiple screws. Distal-varus collapse of the head is a frequent complication in osteoporotic patients. T...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.110138

    authors: Cristofolini L,Ruspi ML,Marras D,Cavallo M,Guerra E

    更新日期:2021-01-22 00:00:00

  • Influence of shoes and heel strike on the loading of the hip joint.

    abstract::The forces and moments acting at the hip joint influence the long-term stability of the fixation of endoprostheses and the course of coxarthrosis. These loads may depend on the kind of footwear and the walking or running style. These factors were investigated in a patient with instrumented hip implants. He wore differ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(94)00129-r

    authors: Bergmann G,Kniggendorf H,Graichen F,Rohlmann A

    更新日期:1995-07-01 00:00:00

  • Variability of tissue mineral density can determine physiological creep of human vertebral cancellous bone.

    abstract::Creep is a time-dependent viscoelastic deformation observed under a constant prolonged load. It has been indicated that progressive vertebral deformation due to creep may increase the risk of vertebral fracture in the long-term. The objective of this study was to examine the relationships of creep with trabecular arch...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.03.025

    authors: Kim DG,Shertok D,Ching Tee B,Yeni YN

    更新日期:2011-06-03 00:00:00

  • Structural and hydrodynamic simulation of an acute stenosis-dependent thrombosis model in mice.

    abstract::Platelet activation under blood flow is thought to be critically dependent on the autologous secretion of soluble platelet agonists (chemical activators) such as ADP and thromboxane. However, recent evidence challenging this model suggests that platelet activation can occur independent of soluble agonist signalling, i...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.02.006

    authors: Tovar-Lopez FJ,Rosengarten G,Khoshmanesh K,Westein E,Jackson SP,Nesbitt WS,Mitchell A

    更新日期:2011-04-07 00:00:00

  • Concurrent repeatability and reproducibility analyses of four marker placement protocols for the foot-ankle complex.

    abstract::Multi-segment models of the foot have been proposed in the past years to overcome limitations imposed by oversimplified traditional approaches used to describe foot kinematics, but they have been only partially validated and never compared. This paper presents a unique comparative assessment of the four most widely ad...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.07.041

    authors: Di Marco R,Rossi S,Racic V,Cappa P,Mazzà C

    更新日期:2016-10-03 00:00:00

  • Application of singular spectrum analysis to the smoothing of raw kinematic signals.

    abstract::Motion capture systems currently used in biomechanical analysis introduce systematic measurement errors that appear in the form of noise in recorded displacement signals. The noise is unacceptably amplified when differentiating displacements to obtain velocities and accelerations. To avoid this phenomenon, it is neces...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2004.05.031

    authors: Alonso FJ,Castillo JM,Pintado P

    更新日期:2005-05-01 00:00:00

  • Modeling the impact of concomitant aortic stenosis and coarctation of the aorta on left ventricular workload.

    abstract::Coarctation of the aorta (COA) is an obstruction of the aorta and is usually associated with bicuspid and tricuspid aortic valve stenosis (AS). When COA coexists with AS, the left ventricle (LV) is facing a double hemodynamic load: a valvular load plus a vascular load. The objective of this study was to develop a lump...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.08.001

    authors: Keshavarz-Motamed Z,Garcia J,Pibarot P,Larose E,Kadem L

    更新日期:2011-11-10 00:00:00

  • Regional load bearing of the feline acetabulum.

    abstract:OBJECTIVE:To test if the caudal acetabulum of the cat is unloaded at mid-stance as has been asserted. MATERIALS AND METHODS:A kinematic study of five healthy cats was performed to ascertain the mid-stance angle of the hip joint, and the orientation of the pelvis and femur. Femora and pelves from 10 feline cadavers wer...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2004.04.035

    authors: Beck AL,Pead MJ,Draper E

    更新日期:2005-03-01 00:00:00

  • The effect of swimming activity on bone architecture in growing rats.

    abstract::The effect of non-habitual physical activity on bone architecture in the rat humeral shaft was examined. Two groups of rats were trained to swim for 1 h a day, for 20 weeks, at two training levels. The control group consisted of sedentary rats. Parameters of cross-sectional bone morphology (cross-section areas, princi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(89)90068-7

    authors: Simkin A,Leichter I,Swissa A,Samueloff S

    更新日期:1989-01-01 00:00:00

  • Tensile property of atheromatous plaque and an analysis of stress in atherosclerotic wall.

    abstract::To know the contributions of blood pressure induced stress to the progression of atherosclerosis and the rupture of atheroma, cross-sectional distributions of stresses in atherosclerotic walls were calculated by finite element method, using stress-strain data of aortic walls and atherosclerotic plaques obtained from h...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(96)00185-6

    authors: Hayashi K,Imai Y

    更新日期:1997-06-01 00:00:00

  • Two mathematical models explain the variation in cystometrograms of obstructed urinary bladders.

    abstract::Overdistension of the urinary bladder, secondary to outlet obstruction, causes cellular changes in the bladder wall, including hypertrophy of the smooth muscle cells, which increase bladder mass. To investigate the effects of increased mass on the cystometrogram (CMG), we have developed two mathematical models. In the...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:

    authors: Damaser MS,Lehman SL

    更新日期:1996-12-01 00:00:00

  • Direct calculation of the surface-to-volume ratio for human cancellous bone.

    abstract::There are many diseases which cause detrimental changes in the trabecular structure of cancellous bone, leading to mechanical failure of the tissue. One approach to understanding the mechanisms of these diseases is to create idealized models that recreate the morphology of the tissue. This paper presents a partial dev...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(93)90057-l

    authors: Fyhrie DP,Fazzalari NL,Goulet R,Goldstein SA

    更新日期:1993-08-01 00:00:00

  • Kinetic analysis of canine gait on the effect of failure tendon repair and tendon graft.

    abstract::Kinetic analysis of canine gait has been extensively studied, including normal and abnormal gait. However, no research has looked into how flexor tendon injury and further treatment would affect the walking pattern comparing to the uninjured state. Therefore, this study was aimed to utilize a portable pressure walkway...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.10.041

    authors: Cheng YS,Reisdorf R,Vrieze A,Moran SL,Amadio PC,An KN,Zhao C

    更新日期:2018-01-03 00:00:00

  • Validation of predicted patellofemoral mechanics in a finite element model of the healthy and cruciate-deficient knee.

    abstract::Healthy patellofemoral (PF) joint mechanics are critical to optimal function of the knee joint. Patellar maltracking may lead to large joint reaction loads and high stresses on the articular cartilage, increasing the risk of cartilage wear and the onset of osteoarthritis. While the mechanical sources of PF joint dysfu...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.12.020

    authors: Ali AA,Shalhoub SS,Cyr AJ,Fitzpatrick CK,Maletsky LP,Rullkoetter PJ,Shelburne KB

    更新日期:2016-01-25 00:00:00