Adversarial autoencoder for visualization and classification of human activity: Application to a low-cost commercial force plate.

Abstract:

:The ability to visualize and interpret high dimensional time-series data will be critical as wearable and other sensors are adopted in rehabilitation protocols. This study proposes a latent space representation of high dimensional time-series data for data visualization. For that purpose, a deep learning model called Adversarial AutoEncoder (AAE) is proposed to perform efficient data dimensionality reduction by considering unsupervised and semi-supervised adversarial training. Eighteen subjects were recruited for the experiment and performed two sets of exercises (upper and lower body) on the Wii Balance Board. Then, the accuracy of the latent space representation is evaluated on both sets of exercises separately. Data dimensionality reduction with conventional Machine Learning (ML) and supervised Deep Learning (DL) classification are also performed to compare the efficiency of AAE approaches. The results showed that AAE can outperform conventional ML approaches while providing close results to DL supervised classification. AAE approaches for data visualization are a promising approach to monitor the subject's movements and detect adverse events or similarity with previous data, providing an intuitive way to monitor the patient's progress and provide potential information for rehabilitation tracking.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Hernandez V,Kulić D,Venture G

doi

10.1016/j.jbiomech.2020.109684

subject

Has Abstract

pub_date

2020-04-16 00:00:00

pages

109684

eissn

0021-9290

issn

1873-2380

pii

S0021-9290(20)30100-7

journal_volume

103

pub_type

杂志文章
  • Comparison of blood particle deposition models for non-parallel flow domains.

    abstract::Adhesions of monocytes and platelets to a vascular surface, particularly in regions of flow stagnation, recirculation, and reattachment, are a significant initial event in a broad spectrum of particle-wall interactions that significantly influence the formation of stenotic lesions and mural thrombi. A number of approx...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(02)00434-7

    authors: Worth Longest P,Kleinstreuer C

    更新日期:2003-03-01 00:00:00

  • Improved walking function in laboratory does not guarantee increased community walking in stroke survivors: Potential role of gait biomechanics.

    abstract::Reduced daily stepping in stroke survivors may contribute to decreased functional capacity and increased mortality. We investigated the relationships between clinical and biomechanical walking measures that may contribute to changes in daily stepping activity following physical interventions provided to participants w...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.05.011

    authors: Ardestani MM,Henderson CE,Hornby TG

    更新日期:2019-06-25 00:00:00

  • PDGF-BB, IGF-I and mechanical load stimulate DNA synthesis in avian tendon fibroblasts in vitro.

    abstract::Resident cells in the surface epitenon and internal compartment of flexor tendons are subjected to cyclic mechanical load as muscle contracts to move limbs or digits. Tendons are largely tensile load bearing tissues and are highly matrix intensive with nondividing cells providing maintenance functions. However, when a...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(95)00098-4

    authors: Banes AJ,Tsuzaki M,Hu P,Brigman B,Brown T,Almekinders L,Lawrence WT,Fischer T

    更新日期:1995-12-01 00:00:00

  • Density of trunk tissues of young and medium age people.

    abstract::In this study the investigations made on about 50 trunk tissue densities are described. They were performed on ten cadavers of both sexes within 24 h of the moment of death. They were 20-40 yr old. The weight of each tissue was measured on a laboratory scale and the volume by placing the tissue in a pycnometer filled ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(90)90360-f

    authors: Erdmann WS,Gos T

    更新日期:1990-01-01 00:00:00

  • Modeling the mechanical properties of liver fibrosis in rats.

    abstract::The progression of liver fibrosis changes the biomechanical properties of liver tissue. This study characterized and compared different liver fibrosis stages in rats in terms of viscoelasticity. Three viscoelastic models, the Voigt, Maxwell, and Zener models, were applied to experimental data from rheometer tests and ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.03.013

    authors: Zhu Y,Chen X,Zhang X,Chen S,Shen Y,Song L

    更新日期:2016-06-14 00:00:00

  • The mechanical effects of different levels of cement penetration at the cement-bone interface.

    abstract::The mechanical effects of varying the depth of cement penetration in the cement-bone interface were investigated using finite element analysis (FEA) and validated using companion experimental data. Two FEA models of the cement-bone interface were created from micro-computed tomography data and the penetration of cemen...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.11.033

    authors: Waanders D,Janssen D,Mann KA,Verdonschot N

    更新日期:2010-04-19 00:00:00

  • Biomechanical influences of pin placement and elbow angle on hinge alignment and joint distraction of bridged elbow-pin-fixator construct.

    abstract::Joint distraction and mobilization with a hinged external fixator preserves elbow stability and mobility. However, the alignment of both elbow and fixator hinges was the initial prerequisite of the arthrodiatasis technique. The main goal of this study was to numerically evaluate the kinematic influence of the device, ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.07.030

    authors: Shih KS,Lin SC,Chao CK,Lee WS,Lu TW,Hou SM

    更新日期:2010-03-03 00:00:00

  • Validation of shear wave elastography in skeletal muscle.

    abstract::Skeletal muscle is a very dynamic tissue, thus accurate quantification of skeletal muscle stiffness throughout its functional range is crucial to improve the physical functioning and independence following pathology. Shear wave elastography (SWE) is an ultrasound-based technique that characterizes tissue mechanical pr...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.07.033

    authors: Eby SF,Song P,Chen S,Chen Q,Greenleaf JF,An KN

    更新日期:2013-09-27 00:00:00

  • Age-related differences in the maintenance of frontal plane dynamic stability while stepping to targets.

    abstract::Older adults may be vulnerable to frontal plane dynamic instability, which is of clinical significance. The purpose of the current investigation was to examine the age-related differences in frontal plane dynamic stability by quantifying the margin of stability and hip abductor moment generation of subjects performing...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.01.003

    authors: Hurt CP,Grabiner MD

    更新日期:2015-02-26 00:00:00

  • An analysis of the complete strain field within Flexercell membranes.

    abstract::The purpose of the current investigation was to use finite element analysis to quantify the complete strain field for the membranes of the Flexercell apparatus, a device extensively used to study the effects of mechanical loading on cultured cells. Four vacuum pressure simulations were run for the membrane for both th...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2004.02.022

    authors: Vande Geest JP,Di Martino ES,Vorp DA

    更新日期:2004-12-01 00:00:00

  • Coping with perturbations to a layout somersault in tumbling.

    abstract::Tumbling is a dynamic movement requiring control of the linear and angular momenta generated during the approach and takeoff phases. Both of these phases are subject to some variability even when the gymnast is trying to perform a given movement repeatedly. This paper used a simulation model of tumbling takeoff to est...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(03)00077-0

    authors: King MA,Yeadon MR

    更新日期:2003-07-01 00:00:00

  • Influence of muscle anatomical cross-sectional area on the moment arm length of the triceps brachii muscle at the elbow joint.

    abstract::The purpose of this study was to test the hypothesis that the musculotendon moment arm length is affected by the muscle anatomical cross-sectional area. The moment arm length of the triceps brachii (TB) muscle at 30°, 50°, 70°, 90°, 110° elbow flexion positions was measured in sagittal magnetic resonance images (MRI) ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.06.013

    authors: Sugisaki N,Wakahara T,Miyamoto N,Murata K,Kanehisa H,Kawakami Y,Fukunaga T

    更新日期:2010-10-19 00:00:00

  • Foot contact identification using a single triaxial accelerometer during running.

    abstract::The analysis of in-field biomechanics data typically requires the identification of foot contact. Existing techniques to identify foot contact using accelerometers offer a viable option for identifying foot contact in the field. However, these techniques often require the placement of additional accelerometers or the ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109768

    authors: Aubol KG,Milner CE

    更新日期:2020-05-22 00:00:00

  • Effects of femoral component placement on the balancing of a total knee at surgery.

    abstract::Misalignment and soft-tissue imbalance in total knee arthroplasty (TKA) can cause discomfort, pain, inadequate motion and instability that may require revision surgery. Balancing can be defined as equal collateral ligament tensions or equal medial and lateral compartmental forces during the flexion range. Our goal was...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.01.056

    authors: Zapata G,Sanz-Pena I,Verstraete M,Walker PS

    更新日期:2019-03-27 00:00:00

  • Towards a viscoelastic model for the unfused midpalatal suture: development and validation using the midsagittal suture in New Zealand white rabbits.

    abstract::Maxillary expansion treatment is a commonly used procedure by orthodontists to widen a patient's upper jaw. As this is typically performed in adolescent patients, the midpalatal suture, connective tissue adjoining the two maxilla halves, remains unfused. Studies that have investigated patient response to expansion tre...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.04.011

    authors: Romanyk DL,Liu SS,Lipsett MG,Toogood RW,Lagravère MO,Major PW,Carey JP

    更新日期:2013-06-21 00:00:00

  • Propulsion biomechanics do not differ between athletic and nonathletic manual wheelchair users in their daily wheelchairs.

    abstract::The purpose of this study was to investigate whether athletic and nonathletic manual wheelchair users (MWU) display differences in kinetic and kinematic variables during daily wheelchair propulsion. Thirty-nine manual wheelchair users (athletic n = 25; nonathletic n = 14) propelled their own daily living wheelchair on...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109725

    authors: Briley SJ,Vegter RJK,Tolfrey VL,Mason BS

    更新日期:2020-05-07 00:00:00

  • Effects of fixation and preservation on tissue elastic properties measured by quantitative optical coherence elastography (OCE).

    abstract::Fixed and preserved tissues have been massively used in the development of biomedical equipment and instrumentation. Not only the tissue morphology, but also its mechanical properties need to be considered in the fixation and preservation procedures since mechanical properties have significant influence on the design ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.02.013

    authors: Ling Y,Li C,Feng K,Duncan R,Eisma R,Huang Z,Nabi G

    更新日期:2016-05-03 00:00:00

  • Rotational kinematics of pelvis and upper trunk at butterfly stroke: Can fins affect the dynamics of the system?

    abstract::The purpose of the present study was to investigate the rotational kinematics pattern of the upper trunk and the pelvis and the complexity-variability of their movement, during the sprint butterfly stroke between male and female swimmers with long fins (18-26 cm) and without fins. Two pairs of 3D accelerometers and gy...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.01.004

    authors: Averianova A,Nikodelis T,Konstantakos V,Kollias I

    更新日期:2016-02-08 00:00:00

  • Simulation of mechanical behavior of temperature-responsive braided stents made of shape memory polyurethanes.

    abstract::Polymeric stents can be considered as an alternative to metallic stents thanks to their lessened incidence of restenosis and controlled deployment. The purpose of this study was to investigate the feasibility of developing a temperature-responsive braided stent using shape memory polyurethane (SMPU) through finite ele...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.10.032

    authors: Kim JH,Kang TJ,Yu WR

    更新日期:2010-03-03 00:00:00

  • The role of the lamellar interface during torsional yielding of human cortical bone.

    abstract::Fragility fractures are a result of alterations in bone quantity, tissue properties, applied loads, or a combination of these factors. The current study addresses the contribution of cortical bone tissue properties to skeletal fragility by characterizing the shear damage accumulation processes which occur during torsi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(98)00179-1

    authors: Jepsen KJ,Davy DT,Krzypow DJ

    更新日期:1999-03-01 00:00:00

  • Finite element models predict cancellous apparent modulus when tissue modulus is scaled from specimen CT-attenuation.

    abstract::High-resolution architecture-based finite element models are commonly used for characterizing the mechanical behavior of cancellous bone. The vast majority of studies use homogeneous material properties to model trabecular tissue. The objectives of this study were to demonstrate that inhomogeneous finite element model...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2003.10.002

    authors: Bourne BC,van der Meulen MC

    更新日期:2004-05-01 00:00:00

  • A force plate study of avian gait.

    abstract:OBJECTIVE:To test the force plate as a gait analysis system for broilers and to determine how the ground reaction force (GRF) patterns change in these birds with growth and administration of analgesia. MATERIALS AND METHODS:Thirty-three male Ross 308 chicks were raised on either an ad libitum or restricted-feeding reg...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2006.09.014

    authors: Corr SA,McCorquodale C,McDonald J,Gentle M,McGovern R

    更新日期:2007-01-01 00:00:00

  • The effect on patellofemoral joint stability of selective cutting of lateral retinacular and capsular structures.

    abstract::Patient selection for lateral retinacular release (LRR) and its efficacy are controversial. Iatrogenic medial subluxation can occur with inappropriate LRR. The aim of this study was to determine the reduction in patellofemoral stability with progressively more extensive LRR. The force required to displace the patella ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.11.003

    authors: Merican AM,Kondo E,Amis AA

    更新日期:2009-02-09 00:00:00

  • Morphing methods to parameterize specimen-specific finite element model geometries.

    abstract::Shape plays an important role in determining the biomechanical response of a structure. Specimen-specific finite element (FE) models have been developed to capture the details of the shape of biological structures and predict their biomechanics. Shape, however, can vary considerably across individuals or change due to...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.08.036

    authors: Sigal IA,Yang H,Roberts MD,Downs JC

    更新日期:2010-01-19 00:00:00

  • In vivo contact areas of the knee in patients with patellar subluxation.

    abstract:OBJECTIVE:Ex vivo studies have suggested that cartilage contact areas and pressure are of high clinical relevance in the etiology of osteoarthritis in patients with patellar subluxation. The aims of this study were therefore to validate in vivo measurements of contact areas with 3D open magnetic resonance imaging (MRI)...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2004.09.008

    authors: Hinterwimmer S,Gotthardt M,von Eisenhart-Rothe R,Sauerland S,Siebert M,Vogl T,Eckstein F,Graichen H

    更新日期:2005-10-01 00:00:00

  • Explicit finite element modeling of total knee replacement mechanics.

    abstract::Joint kinematics and contact mechanics dictate the success of current total knee replacement (TKR) devices. Efficient computer models present an effective way of evaluating these characteristics. Predicted contact stress and area due to articulations at the tibio-femoral and patello-femoral interfaces indicate potenti...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2004.02.046

    authors: Halloran JP,Petrella AJ,Rullkoetter PJ

    更新日期:2005-02-01 00:00:00

  • Endothelialization of over- and undersized flow-diverter stents at covered vessel side branches: An in vivo and in silico study.

    abstract::Although flow-diverting devices are promising treatment options for intracranial aneurysms, jailed side branches might occlude leading to insufficient blood supply. Especially differences in the local stent strut compression may have a drastic influence on subsequent endothelialization. To investigate the outcome of d...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.10.047

    authors: Berg P,Iosif C,Ponsonnard S,Yardin C,Janiga G,Mounayer C

    更新日期:2016-01-04 00:00:00

  • Quantitative associations between osteocyte density and biomechanics, microcrack and microstructure in OVX rats vertebral trabeculae.

    abstract::Osteocytes actively regulate bone modeling and remodeling, direct skeletal mineralization, and regulate calcium/phosphate homeostasis and extracellular matrix metabolism; yet the specific role of osteocytes in maintaining bone structural integrity and strength is unknown. Studies have shown that the density of osteocy...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.01.017

    authors: Ma YL,Dai RC,Sheng ZF,Jin Y,Zhang YH,Fang LN,Fan HJ,Liao EY

    更新日期:2008-01-01 00:00:00

  • On precision limits for derivatives numerically calculated from noisy data.

    abstract::This paper has three purposes. (1) To verify an error formula from which the maximal precision in derivatives obtained from noisy measurement data can be calculated. The formula is verified by comparison with the resulting noise in derivatives obtained by local least squares polynomial fitting. It is also verified tha...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(82)90082-3

    authors: Lanshammar H

    更新日期:1982-01-01 00:00:00

  • Accuracy of a contour-based biplane fluoroscopy technique for tracking knee joint kinematics of different speeds.

    abstract::While measuring knee motion in all six degrees of freedom is important for understanding and treating orthopaedic knee pathologies, traditional motion capture techniques lack the required accuracy. A variety of model-based biplane fluoroscopy techniques have been developed with sub-millimeter accuracy. However, no stu...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2012.08.045

    authors: Giphart JE,Zirker CA,Myers CA,Pennington WW,LaPrade RF

    更新日期:2012-11-15 00:00:00