Compressive strain rate sensitivity of ballistic gelatin.

Abstract:

:Gelatin is a popular tissue simulant used in biomedical applications. The uniaxial compressive stress-strain response of gelatin was determined at a range of strain rates. In the quasistatic regime, gelatin strength remained relatively constant. With increase in loading rate, the compressive strength increased from 3kPa at a strain rate of around 0.0013/s to 6MPa at a strain rate of around 3200/s. This dramatic increase in strength of gelatin at high rates is attributed to its shear-thickening behavior and is argued on the basis of hydrocluster formation mechanism and differences in internal energy dissipation mechanism under static and dynamic loading.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Kwon J,Subhash G

doi

10.1016/j.jbiomech.2009.10.008

subject

Has Abstract

pub_date

2010-02-10 00:00:00

pages

420-5

issue

3

eissn

0021-9290

issn

1873-2380

pii

S0021-9290(09)00581-8

journal_volume

43

pub_type

杂志文章
  • High frequency components of bone strain in dogs measured during various activities.

    abstract::Rubin et al. [J. Biomechanics 23, 43-54 (1990)] proposed that high frequency bone strains in the 15-30 Hz range might have significant influence on the morphological adaptation of bone tissue. We sought to further their findings by determining the magnitude of high frequency strains during various activities. We measu...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(95)80005-0

    authors: Turner CH,Yoshikawa T,Forwood MR,Sun TC,Burr DB

    更新日期:1995-01-01 00:00:00

  • Multiple-step model-experiment matching allows precise definition of dynamical leg parameters in human running.

    abstract::The spring-loaded inverted pendulum (SLIP) model is a well established model for describing bouncy gaits like human running. The notion of spring-like leg behavior has led many researchers to compute the corresponding parameters, predominantly stiffness, in various experimental setups and in various ways. However, dif...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2012.06.030

    authors: Ludwig C,Grimmer S,Seyfarth A,Maus HM

    更新日期:2012-09-21 00:00:00

  • Simulation of mechanical behavior of temperature-responsive braided stents made of shape memory polyurethanes.

    abstract::Polymeric stents can be considered as an alternative to metallic stents thanks to their lessened incidence of restenosis and controlled deployment. The purpose of this study was to investigate the feasibility of developing a temperature-responsive braided stent using shape memory polyurethane (SMPU) through finite ele...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.10.032

    authors: Kim JH,Kang TJ,Yu WR

    更新日期:2010-03-03 00:00:00

  • The measurement of body segment inertial parameters using dual energy X-ray absorptiometry.

    abstract::Accurate body segment parameter (BSP) information is required for dynamic analyses of motion and the current methods available for obtaining these BSPs have been criticized. The purpose of this study was to determine whether dual energy X-ray absorptiometry (DXA) could accurately measure the BSPs of scanned objects an...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(02)00227-0

    authors: Durkin JL,Dowling JJ,Andrews DM

    更新日期:2002-12-01 00:00:00

  • Differences in stretch-shortening cycle and residual force enhancement between muscles.

    abstract::It has been suggested that cross bridge kinetics and residual force enhancement (RFE) affect force in the stretch-shortening cycle (SSC). Because cross bridge kinetics and titin isoforms, which are thought to be related to RFE, differ between muscles, the SSC effect may be also muscle-dependent. Thus, we compared the ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.110040

    authors: Fukutani A,Herzog W

    更新日期:2020-11-09 00:00:00

  • The role of the lamellar interface during torsional yielding of human cortical bone.

    abstract::Fragility fractures are a result of alterations in bone quantity, tissue properties, applied loads, or a combination of these factors. The current study addresses the contribution of cortical bone tissue properties to skeletal fragility by characterizing the shear damage accumulation processes which occur during torsi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(98)00179-1

    authors: Jepsen KJ,Davy DT,Krzypow DJ

    更新日期:1999-03-01 00:00:00

  • Ulceration, unsteadiness, and uncertainty: the biomechanical consequences of diabetes mellitus.

    abstract::Diabetes mellitus, which results from a failure of the endocrine system to control blood glucose levels within normal limits, affects approximately 15% of the population over the age of 65 in developed countries. Between 20-50% of people with diabetes for more than 10 years will experience symmetrical distal sensory n...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章,评审

    doi:10.1016/0021-9290(93)90077-r

    authors: Cavanagh PR,Simoneau GG,Ulbrecht JS

    更新日期:1993-01-01 00:00:00

  • The fixion proximal femur nailing system: biomechanical properties of the nail and a cadaveric study.

    abstract::The treatment of choice for early mobilization of hip fracture is surgery, which traditionally employs side plates and screws or intramedullary nails. We examined the biomechanical properties of a new proximal femoral nail system. The new expandable Fixion proximal femur nailing (PFN) system, made of stainless-steel a...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2004.03.014

    authors: Steinberg EL,Blumberg N,Dekel S

    更新日期:2005-01-01 00:00:00

  • Resonant frequencies of arms and legs identify different walking patterns.

    abstract::The present study is aimed at investigating changes in the coordination of arm and leg movements in young healthy subjects. It was hypothesized that with changes in walking velocity there is a change in frequency and phase coupling between the arms and the legs. In addition, it was hypothesized that the preferred freq...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(00)00020-8

    authors: Wagenaar RC,van Emmerik RE

    更新日期:2000-07-01 00:00:00

  • Prediction of upper extremity impact forces during falls on the outstretched hand.

    abstract::Among the most common causes of upper extremity fracture is a fall on the outstretched hand. Yet few data exist on the biomechanical factors which affect injury risk during this event. In this study, we measured impact forces during low-height (0-5 cm), forward falls onto the outstretched hand, and found that these ar...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(98)00137-7

    authors: Chiu J,Robinovitch SN

    更新日期:1998-12-01 00:00:00

  • Further evidence for the dynamic stability of intracranial saccular aneurysms.

    abstract::It has long been thought that intracranial saccular aneurysms enlarge and rupture because of mechanical instabilities. Recent nonlinear analyses suggest, however, that at least certain sub-classes of aneurysms do not exhibit quasi-static limit point instabilities or dynamic instabilities in response to periodic loadin...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(03)00083-6

    authors: David G,Humphrey JD

    更新日期:2003-08-01 00:00:00

  • Regional load bearing of the feline acetabulum.

    abstract:OBJECTIVE:To test if the caudal acetabulum of the cat is unloaded at mid-stance as has been asserted. MATERIALS AND METHODS:A kinematic study of five healthy cats was performed to ascertain the mid-stance angle of the hip joint, and the orientation of the pelvis and femur. Femora and pelves from 10 feline cadavers wer...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2004.04.035

    authors: Beck AL,Pead MJ,Draper E

    更新日期:2005-03-01 00:00:00

  • Micromechanics modeling of Haversian cortical bone properties.

    abstract::A finite-element micromechanics model for Haversian cortical bone tissue has been developed and studied. The model is an extension of two-dimensional micromechanics techniques for fiber-reinforced composite materials. Haversian systems, or secondary osteons, are considered to be the fiber component, and interstitial l...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(92)90095-i

    authors: Hogan HA

    更新日期:1992-05-01 00:00:00

  • A force plate study of avian gait.

    abstract:OBJECTIVE:To test the force plate as a gait analysis system for broilers and to determine how the ground reaction force (GRF) patterns change in these birds with growth and administration of analgesia. MATERIALS AND METHODS:Thirty-three male Ross 308 chicks were raised on either an ad libitum or restricted-feeding reg...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2006.09.014

    authors: Corr SA,McCorquodale C,McDonald J,Gentle M,McGovern R

    更新日期:2007-01-01 00:00:00

  • On the permanent hip-stabilizing effect of atmospheric pressure.

    abstract::Hip joint dislocations related to total hip arthroplasty (THA) are a common complication especially in the early postoperative course. The surgical approach, the alignment of the prosthetic components, the range of motion and the muscle tone are known factors influencing the risk of dislocation. A further factor that ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.05.013

    authors: Prietzel T,Hammer N,Schleifenbaum S,Kaßebaum E,Farag M,von Salis-Soglio G

    更新日期:2014-08-22 00:00:00

  • Large scale simulation of red blood cell aggregation in shear flows.

    abstract::Aggregation of highly deformable red blood cells (RBCs) significantly affects the blood flow in the human circulatory system. To investigate the effect of deformation and aggregation of RBCs in blood flow, a mathematical model has been established by coupling the interaction between the fluid and the deformable solids...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.05.010

    authors: Xu D,Kaliviotis E,Munjiza A,Avital E,Ji C,Williams J

    更新日期:2013-07-26 00:00:00

  • Cost-effective (gaming) motion and balance devices for functional assessment: Need or hype?

    abstract::In the last decade, technological advances in the gaming industry have allowed the marketing of hardware for motion and balance control that is based on technological concepts similar to scientific and clinical equipment. Such hardware is attractive to researchers and clinicians for specific applications. However, som...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.07.011

    authors: Bonnechère B,Jansen B,Van Sint Jan S

    更新日期:2016-09-06 00:00:00

  • Ambulatory measurement of the knee adduction moment in patients with osteoarthritis of the knee.

    abstract::High knee joint-loading increases the risk and progression of knee osteoarthritis (OA). Mechanical loading on the knee is reflected in the external knee adduction moment (KAdM) that can be measured during gait with laboratory-based measurement systems. However, clinical application of these systems is limited. Ambulat...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2012.09.030

    authors: van den Noort JJ,van der Esch M,Steultjens MP,Dekker J,Schepers MH,Veltink PH,Harlaar J

    更新日期:2013-01-04 00:00:00

  • Velocities and stress levels of axisymmetric, azimuthal flow within the toroidal rotary seal of the IBM 2997 continuous flow cell separator and the implications.

    abstract::Continuous flow blood fraction separators are used to facilitate the removal of specific blood components for donation or for certain medical procedures. Problems with one such device, the IBM 2997 Blood Processor, have been noted in a number of independent investigations. A key feature of this particular unit is a ce...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(86)90163-6

    authors: Harvey CB,O'Rear EA

    更新日期:1986-01-01 00:00:00

  • Prediction of closed-chain human arm dynamics in a crank-rotation task.

    abstract::This paper deals with the analysis of human arm movement in a crank-rotation task that is an example of environmentally constrained movements. Opening a door, rotating a steering wheel, and pushing a carriage are other typical examples of movements where the physical constraints, imposed on the hand position/orientati...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.05.034

    authors: Davoudabadi Farahani S,Svinin M,Andersen MS,de Zee M,Rasmussen J

    更新日期:2016-09-06 00:00:00

  • Normal and shear stresses influence the spatial distribution of intracellular adhesion molecule-1 expression in human umbilical vein endothelial cells exposed to sudden expansion flow.

    abstract::Patterns in cell adhesion molecule expression by endothelial cells may play a role in atherogenesis. Previous studies have shown dependence of intracellular adhesion molecule-1 (ICAM-1) expression in human umbilical vein endothelial cells (HUVEC) on shear stress and have indirectly linked ICAM-1 expression to spatial ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2005.02.002

    authors: McKinney VZ,Rinker KD,Truskey GA

    更新日期:2006-01-01 00:00:00

  • The influences of foot placement on lumbopelvic rhythm during trunk flexion motion.

    abstract::Different standing postures could potentially influence trunk biomechanics during task performance. The current study investigated how foot placement, especially stance width and foot angle influenced lumbopelvic rhythm during sagittal trunk flexion motion. Ten participants performed pace controlled sagittally symmetr...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.03.048

    authors: Zhou J,Ning X,Hu B,Dai B

    更新日期:2016-06-14 00:00:00

  • The influence of mechanical stimulus on the pattern of tissue differentiation in a long bone fracture--an FEM study.

    abstract::2D, coronal plane, finite elements models (FEMs) were developed from orthogonal radiographs of a diaphyseal tibial fracture and its reparative tissue at four different time points during healing. Each callus was separated into regions of common tissue histology by computerised radiographic analysis. Starting point val...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(99)00189-x

    authors: Gardner TN,Stoll T,Marks L,Mishra S,Knothe Tate M

    更新日期:2000-04-01 00:00:00

  • Translational constraint influences dynamic spinal canal occlusion of the thoracic spine: an in vitro experimental study.

    abstract::Mechanical constraints to spine motion can arise in a variety of real-world situations such as when shoulder belts prevent anterior translation of the thorax during automotive collisions. The effect of such constraint on spinal column-spinal cord interaction during injury remains unknown. The purpose of the present st...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.06.030

    authors: Zhu Q,Lane C,Ching RP,Gordon JD,Fisher CG,Dvorak MF,Cripton PA,Oxland TR

    更新日期:2008-01-01 00:00:00

  • In vivo measurement of ACL length and relative strain during walking.

    abstract::Although numerous studies have addressed the effects of ACL injury and reconstruction on knee joint motion, there is currently little data available describing in vivo ACL strain during activities of daily living. Data describing in vivo ACL strain during activities such as gait is critical to understanding the biomec...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.jbiomech.2012.10.031

    authors: Taylor KA,Cutcliffe HC,Queen RM,Utturkar GM,Spritzer CE,Garrett WE,DeFrate LE

    更新日期:2013-02-01 00:00:00

  • Effect of wedging on the flow characteristics past tilting disc aortic valve prosthesis.

    abstract::To evaluate the efficacy of implanting a tilting disc aortic valve prosthesis in an angulated (wedged) supra-annular position, an in vitro experimental study was performed. The aortic valve prosthesis was mounted in an axi-symmetric valve chamber in a wedged position and incorporated in a mock circulatory system. Meas...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(86)90150-8

    authors: Chandran KB,Fatemi R,Hiratzka LF,Harris C

    更新日期:1986-01-01 00:00:00

  • Multi-slice ultrasound image calibration of an intelligent skin-marker for soft tissue artefact compensation.

    abstract::In this paper, a novel multi-slice ultrasound (US) image calibration of an intelligent skin-marker used for soft tissue artefact compensation is proposed to align and orient image slices in an exact H-shaped pattern. Multi-slice calibration is complex, however, in the proposed method, a phantom based visual alignment ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.12.030

    authors: Masum MA,Pickering MR,Lambert AJ,Scarvell JM,Smith PN

    更新日期:2017-09-06 00:00:00

  • Knee kinematics and kinetics during shuttle run cutting: comparison of the assessments performed with and without the point cluster technique.

    abstract::The differences between the assessments performed with and without the point cluster technique (PCT) for knee joint motions during the high-risk movements associated with non-contact anterior cruciate ligament (ACL) injuries have not been reported. This study aims to examine the differences between PCT and non-PCT ass...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.05.001

    authors: Ishii H,Nagano Y,Ida H,Fukubayashi T,Maruyama T

    更新日期:2011-07-07 00:00:00

  • The effect of sterilization on the dynamic mechanical properties of paired rabbit cortical bone.

    abstract::The optimal sterilization method for load bearing allografts remains a clinical concern. Recently, supercritical carbon dioxide (SCCO2) treatments have been shown to be capable of terminally sterilizing a range of bacteria and viruses, while preserving the static mechanical properties of cortical bone. This study eval...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.04.006

    authors: Russell N,Rives A,Bertollo N,Pelletier MH,Walsh WR

    更新日期:2013-06-21 00:00:00

  • Steady flow in a model of the human carotid bifurcation. Part I--flow visualization.

    abstract::The geometry of a typical adult human carotid bifurcation, complete with the sinus, was established from a study of a large number of angiograms. A rigid model was constructed from glass and investigations were performed under steady flow conditions using flow visualization techniques over a range of upstream Reynolds...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(82)90057-4

    authors: Bharadvaj BK,Mabon RF,Giddens DP

    更新日期:1982-01-01 00:00:00