Density and hydration of fresh and fixed human skeletal muscle.

Abstract:

:The maximum tetanic tension of skeletal muscle (P(0)) is often estimated based on calculation of physiological cross-sectional area (PCSA). PCSA depends on muscle volume, pennation angle, and fiber length. Studies documenting PCSA in fixed human muscles usually compute muscle volume by dividing muscle mass by density. These studies use a density value of 1.0597 g/cm(3), which was originally based on unfixed rabbit and canine muscle tissue. Due to the dehydration effects of different fixation methods, the variable hydration that occurs when fixed tissue is stored in buffered saline, and the potential for species-specific muscle density, this value may be incorrect and an accurate value for fixed human muscle density is needed. To obtain an accurate density and water content values, 4% formaldehyde-fixed (n=54) and 37% formaldehyde-fixed (n=54) cadaveric human muscle samples were divided into 6 groups (0, 6, 12, 18, 24, or 30 h) for hydration in phosphate buffered saline (PBS). Measurements of volume, water content, and mass were made enabling calculation of muscle density. Additionally, water content was measured in living muscle (n=4) to determine the appropriate hydration time in PBS. Comparisons among groups demonstrated a significant increase in muscle water content and muscle volume over time, reaching living tissue levels after 24h, but, interestingly, the hydration process did not affect muscle density. These data yield a density value (mean+/-SE) of 1.112+/-0.006 g/cm(3) in 4% formaldehyde-fixed muscle and 1.055+/-0.006 g/cm(3) in 37% formaldehyde-fixed muscle. These results indicate that the use of inappropriate hydration times or density values can produce PCSA errors of 5-10%.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Ward SR,Lieber RL

doi

10.1016/j.jbiomech.2004.10.001

keywords:

subject

Has Abstract

pub_date

2005-11-01 00:00:00

pages

2317-20

issue

11

eissn

0021-9290

issn

1873-2380

pii

S0021-9290(04)00507-X

journal_volume

38

pub_type

杂志文章
  • In-vivo analysis of sliding distance and cross-shear in Bi-cruciate retaining total knee arthroplasty.

    abstract::Polyethylene remains the most popular bearing material for total knee arthroplasty (TKA). Despite its widespread use, wear continue to be one of major factors implicated in revision surgery. Sliding distance, cross-shear, and contact stress are the major factors influencing polyethylene wear. As previous studies have ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.06.009

    authors: Arauz P,Peng Y,An S,Kwon YM

    更新日期:2018-08-22 00:00:00

  • Validation of a calibration technique for 6-DOF instrumented spatial linkages.

    abstract::This paper presents a practical and effective approach to the calibration of instrumented spatial linkages for biomechanical applications. A 6-DOF mechanical linkage with rotational transducers is designed and in-house manufactured for this purpose. In order to assess the validity of the proposed calibration technique...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2006.06.021

    authors: Gatti G,Danieli G

    更新日期:2007-01-01 00:00:00

  • Identification of key events in baseball hitting using inertial measurement units.

    abstract::Quantification of baseball hitting mechanics under game conditions help players to become successful batters and prevent injuries. Inertial measurement units (IMUs) can measure motion without any spatial restriction and are thus becoming a popular tool to investigate sports biomechanics. Biomechanical analysis of hitt...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.02.001

    authors: Punchihewa NG,Yamako G,Fukao Y,Chosa E

    更新日期:2019-04-18 00:00:00

  • Humans control stride-to-stride stepping movements differently for walking and running, independent of speed.

    abstract::As humans walk or run, external (environmental) and internal (physiological) disturbances induce variability. How humans regulate this variability from stride-to-stride can be critical to maintaining balance. One cannot infer what is "controlled" based on analyses of variability alone. Assessing control requires quant...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.05.034

    authors: Dingwell JB,Bohnsack-McLagan NK,Cusumano JP

    更新日期:2018-07-25 00:00:00

  • Influence of muscle anatomical cross-sectional area on the moment arm length of the triceps brachii muscle at the elbow joint.

    abstract::The purpose of this study was to test the hypothesis that the musculotendon moment arm length is affected by the muscle anatomical cross-sectional area. The moment arm length of the triceps brachii (TB) muscle at 30°, 50°, 70°, 90°, 110° elbow flexion positions was measured in sagittal magnetic resonance images (MRI) ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.06.013

    authors: Sugisaki N,Wakahara T,Miyamoto N,Murata K,Kanehisa H,Kawakami Y,Fukunaga T

    更新日期:2010-10-19 00:00:00

  • Combined effects of microtopography and cyclic strain on vascular smooth muscle cell orientation.

    abstract::Cellular alignment studies have shown that cell orientation has a large effect on the expression and behavior of cells. Cyclic strain and substrate microtopography have each been shown to regulate cellular alignment. This study examined the combined effects of these two stimuli on the alignment of bovine vascular smoo...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.11.027

    authors: Houtchens GR,Foster MD,Desai TA,Morgan EF,Wong JY

    更新日期:2008-01-01 00:00:00

  • Osteochondral graft fixation using a bioresorbable bone cement.

    abstract::Multiple osteochondral grafts can be used to resurface large joint defects in both humans and horses. In humans, immediate postoperative weight bearing can be prevented, however in the equine, it is unavoidable. Early weight bearing can create detrimental graft micromotion. The aim of this study was to investigate the...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2005.10.007

    authors: Changoor A,Hurtig MB,John Runciman R

    更新日期:2006-01-01 00:00:00

  • Mathematical modeling of the stress strain-strain rate behavior of bone using the Ramberg-Osgood equation.

    abstract::The Ramberg-Osgood equation is used to model the viscoplastic properties of compact bone. Because of the exponential nature of this equation a special optimization technique is used to curve fitting. Results are presented for the application of this equation to three sets of strain rate dependent stress-strain curves ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(83)90076-3

    authors: Hight TK,Brandeau JF

    更新日期:1983-01-01 00:00:00

  • Validation of the greater trochanter method with radiographic measurements of frontal plane hip joint centers and knee mechanical axis angles and two other hip joint center methods.

    abstract::Several motion capture methods exist for predicting hip joint centers (HJC). These methods include regression models, functional joints, and projections from greater trochanters. While regression and functional methods have been compared to imaging techniques, the TROCH method has not been previously validated. The pu...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.06.013

    authors: Bennett HJ,Shen G,Weinhandl JT,Zhang S

    更新日期:2016-09-06 00:00:00

  • Differences in stretch-shortening cycle and residual force enhancement between muscles.

    abstract::It has been suggested that cross bridge kinetics and residual force enhancement (RFE) affect force in the stretch-shortening cycle (SSC). Because cross bridge kinetics and titin isoforms, which are thought to be related to RFE, differ between muscles, the SSC effect may be also muscle-dependent. Thus, we compared the ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.110040

    authors: Fukutani A,Herzog W

    更新日期:2020-11-09 00:00:00

  • A simulation study of vertical jumping from different starting postures.

    abstract::This paper addresses the question of whether maximal vertical jump height depends on initial jumping posture. A direct dynamics computer simulation approach was used to avoid subject preference and practice effects. The human body was modeled as four rigid segments connected by ideal hinge joints, with movement constr...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(96)00030-9

    authors: Selbie WS,Caldwell GE

    更新日期:1996-09-01 00:00:00

  • Influence of the renal artery ostium flow diverter on hemodynamics and atherogenesis.

    abstract::The structure and function of the renal artery ostium flow diverter on the caudal side of the renal branch point were previously reported; in this study, we further evaluate the diverter׳s possible functions. The protrusion of this structure into the abdominal aorta suggests that the diverter may preferentially direct...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.03.006

    authors: Albert S,Balaban RS,Neufeld EB,Rossmann JS

    更新日期:2014-05-07 00:00:00

  • In-vivo analysis of thoracic mechanical response under belt loading: the role of body mass index in thorax stiffness.

    abstract::Thoracic injuries are a major cause of mortality in frontal collisions, especially for elderly and obese people. Car occupant individual characteristics like BMI are known to influence human vulnerability in crashes. In the present study, thoracic mechanical response of volunteers quantified by optical method was link...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.jbiomech.2012.12.021

    authors: Poulard D,Bermond F,Compigne S,Bruyère K

    更新日期:2013-03-15 00:00:00

  • Using force sensing insoles to predict kinetic knee symmetry during a stop jump.

    abstract::Knee kinetic asymmetries are present during jump-landings in athletes returning to sport following anterior cruciate ligament (ACL) reconstruction, and are associated with an increased risk for sustaining a second ACL injury. The loadsol® is a wireless load sensing insole that can be used in non-laboratory settings. T...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.07.037

    authors: Peebles AT,Ford KR,Taylor JB,Hart JM,Sands LP,Queen RM

    更新日期:2019-10-11 00:00:00

  • Inter-segmental coordination: motor pattern in humans stepping over an obstacle with mechanical ankle joint friction.

    abstract::This study examined the influence of a mechanical perturbation of the ankle joint on obstacle avoidance pattern. A decoupled control between the distal joint and the combined (hip-knee) proximal joints was observed according to the task requirement. In this context, a greater mechanical friction at the ankle should be...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.jbiomech.2004.07.019

    authors: Gueguen N,Charbonneau M,Robert G,Coyle T,Prince F,Mouchnino L

    更新日期:2005-07-01 00:00:00

  • Measurement of in vivo anterior cruciate ligament strain during dynamic jump landing.

    abstract::Despite recent attention in the literature, anterior cruciate ligament (ACL) injury mechanisms are controversial and incidence rates remain high. One explanation is limited data on in vivo ACL strain during high-risk, dynamic movements. The objective of this study was to quantify ACL strain during jump landing. Marker...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.10.028

    authors: Taylor KA,Terry ME,Utturkar GM,Spritzer CE,Queen RM,Irribarra LA,Garrett WE,DeFrate LE

    更新日期:2011-02-03 00:00:00

  • Toward quantification of athetotic movements by frequency spectrum analysis.

    abstract::The frequency spectrum of the elbow movements of one normal subject and six handicapped subjects were obtained in order to investigate the possibility of using this technique in quantifying athetosis. The frequency spectrum technique appears to be useful but data from more subjects must be obtained and specific detail...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(85)90046-6

    authors: Niku S,Henderson JM

    更新日期:1985-01-01 00:00:00

  • Differences in 3D vs. 2D analysis in lumbar spinal fusion simulations.

    abstract::Lumbar interbody fusion is currently the gold standard in treating patients with disc degeneration or segmental instability. Despite it having been used for several decades, the non-union rate remains high. A failed fusion is frequently attributed to an inadequate mechanical environment after instrumentation. Finite e...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.03.009

    authors: Hsu HW,Bashkuev M,Pumberger M,Schmidt H

    更新日期:2018-04-27 00:00:00

  • Force response of the fingertip pulp to repeated compression--effects of loading rate, loading angle and anthropometry.

    abstract::Repeated loading of the fingertips has been postulated to contribute to tendon and nerve disorders at the wrist during activities associated with prolonged fingertip loading such as typing. To fully understand the pathomechanics of these soft tissue disorders, the role of the fingertip pulp in attenuating the applied ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(97)00065-1

    authors: Serina ER,Mote CD Jr,Rempel D

    更新日期:1997-10-01 00:00:00

  • Acquisition of full-field strain distributions on ovine fracture callus cross-sections with electronic speckle pattern interferometry.

    abstract::This study evaluated the feasibility of assessing continuous strain distributions on fracture callus cross-sections with an electronic speckle pattern interferometry (ESPI) system. Mid-sagittal callus cross-sections were harvested from ovine tibiae. One low stiffness (LS) specimen and one high stiffness (HS) specimen ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.10.024

    authors: Bottlang M,Mohr M,Simon U,Claes L

    更新日期:2008-01-01 00:00:00

  • Comparison of micro-level and continuum-level voxel models of the proximal femur.

    abstract::Continuum-level finite element (FE) models became standard computational tools for the evaluation of bone mechanical behavior from in vivo computed tomography scans. Such scans do not account for the anisotropy of the bone. Instead, local mechanical properties in the continuum-level FE models are assumed isotropic and...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2005.10.027

    authors: Verhulp E,van Rietbergen B,Huiskes R

    更新日期:2006-01-01 00:00:00

  • The influence of ligament modelling strategies on the predictive capability of finite element models of the human knee joint.

    abstract::In finite element (FE) models knee ligaments can represented either by a group of one-dimensional springs, or by three-dimensional continuum elements based on segmentations. Continuum models closer approximate the anatomy, and facilitate ligament wrapping, while spring models are computationally less expensive. The me...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.08.030

    authors: Naghibi Beidokhti H,Janssen D,van de Groes S,Hazrati J,Van den Boogaard T,Verdonschot N

    更新日期:2017-12-08 00:00:00

  • Stone comminution correlates with the average peak pressure incident on a stone during shock wave lithotripsy.

    abstract::To investigate the roles of lithotripter shock wave (LSW) parameters and cavitation in stone comminution, a series of in vitro fragmentation experiments have been conducted in water and 1,3-butanediol (a cavitation-suppressive fluid) at a variety of acoustic field positions of an electromagnetic shock wave lithotripte...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2012.07.025

    authors: Smith N,Zhong P

    更新日期:2012-10-11 00:00:00

  • Blood and interstitial flow in the hierarchical pore space architecture of bone tissue.

    abstract::There are two main types of fluid in bone tissue, blood and interstitial fluid. The chemical composition of these fluids varies with time and location in bone. Blood arrives through the arterial system containing oxygen and other nutrients and the blood components depart via the venous system containing less oxygen an...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.12.013

    authors: Cowin SC,Cardoso L

    更新日期:2015-03-18 00:00:00

  • Effects of mechanical loading patterns, bone graft, and proximity to periosteum on bone defect healing.

    abstract::The goal of this study is to elucidate whether mechanobiological factors, including mechanical loading patterns, presence of bone graft, and proximity to the periosteum, correlate to de novo tissue generation and healing in critical sized long bone defects, which are enveloped by periosteum in situ and are bridged at ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.06.026

    authors: Knothe UR,Dolejs S,Matthew Miller R,Knothe Tate ML

    更新日期:2010-10-19 00:00:00

  • A mechanically decoupled two force component bicycle pedal dynamometer.

    abstract::A design is presented for a bicycle pedal dynamometer that measures both normal and tangential forces (i.e. driving forces). Mechanical decoupling is used to reduce the cross-sensitivity of the dynamometer to loads doing no work to propel the bicycle. This obviates the need to measure all six loads for accurate data r...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(88)90144-3

    authors: Newmiller J,Hull ML,Zajac FE

    更新日期:1988-01-01 00:00:00

  • Identification of a hemodynamic parameter for assessing treatment outcome of EDAS in Moyamoya disease.

    abstract::This work is a novel attempt to incorporate computational fluid dynamics (CFD) techniques in the analysis of hemodynamic parameters of Moyamoya disease (MMD). Highly prevalent in Asian countries, MMD is characterised by progressive occlusion of the intracranial Internal Carotid Arteries (ICA). We intend to identify a ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.11.029

    authors: Karunanithi K,Han C,Lee CJ,Shi W,Duan L,Qian Y

    更新日期:2015-01-21 00:00:00

  • Assessment of intersegmental coordination of rats during walking at different speeds - Application of continuous relative phase.

    abstract::The present study investigated the feasibility and reliability of continuous relative phase (CRP) and deviation phase (DP) to assess intersegmental hind limb coordination pattern and coordination variability in rats during walking. Twenty-six adult rats walked at 8 m/min, 12 m/min and 16 m/min while two-dimensional ki...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.03.045

    authors: Raffalt PC,Nielsen LR,Madsen S,Højberg LM,Pingel J,Nielsen JB,Alkjær T,Wienecke J

    更新日期:2018-05-17 00:00:00

  • Muscle activities of the lower limb during level and uphill running.

    abstract::This study aimed to compare the muscle activities of the lower limb during overground level running (LR) and uphill running (UR) by using a musculoskeletal model. Six male distance runners ran at three running speeds (slow: 3.3 m/s; medium: 4.2 m/s; and high: 5.0 m/s) on a level runway and a slope of 9.1% grade in whi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.05.028

    authors: Yokozawa T,Fujii N,Ae M

    更新日期:2007-01-01 00:00:00

  • Biomechanical influences of pin placement and elbow angle on hinge alignment and joint distraction of bridged elbow-pin-fixator construct.

    abstract::Joint distraction and mobilization with a hinged external fixator preserves elbow stability and mobility. However, the alignment of both elbow and fixator hinges was the initial prerequisite of the arthrodiatasis technique. The main goal of this study was to numerically evaluate the kinematic influence of the device, ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.07.030

    authors: Shih KS,Lin SC,Chao CK,Lee WS,Lu TW,Hou SM

    更新日期:2010-03-03 00:00:00