Combined effects of microtopography and cyclic strain on vascular smooth muscle cell orientation.

Abstract:

:Cellular alignment studies have shown that cell orientation has a large effect on the expression and behavior of cells. Cyclic strain and substrate microtopography have each been shown to regulate cellular alignment. This study examined the combined effects of these two stimuli on the alignment of bovine vascular smooth muscle cells (VSMCs). Cells were cultured on substrates with microgrooves of varying widths oriented either parallel or perpendicular to the direction of an applied cyclic tensile strain. We found that microgrooves oriented parallel to the direction of the applied strain limited the orientation response of VSMCs to the mechanical stimulus, while grooves perpendicular to the applied strain enhanced cellular alignment. Further, the extent to which parallel grooves limited cell alignment was found to be dependent on the groove width. It was found that for both a small (15microm) and a large (70microm) groove width, cells were better able to reorient in response to the applied strain than for an intermediate groove width (40microm). This study indicates that microtopographical cues modulate the orientation response of VSMCs to cyclic strain. The results suggest that there is a range of microgroove dimensions that is most effective at maintaining the orientation of the cells in the presence of an opposing stimulus induced by cyclic strain.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Houtchens GR,Foster MD,Desai TA,Morgan EF,Wong JY

doi

10.1016/j.jbiomech.2007.11.027

subject

Has Abstract

pub_date

2008-01-01 00:00:00

pages

762-9

issue

4

eissn

0021-9290

issn

1873-2380

pii

S0021-9290(07)00513-1

journal_volume

41

pub_type

杂志文章
  • Effect of the "squat protective response" on impact velocity during backward falls.

    abstract::Risk for injury during a fall depends on the position and velocity of the body segments at the moment of impact. One technique for reducing impact velocity is to absorb energy in the lower extremity muscles during descent, as occurs during squatting or sitting. However, the protective value of this response may depend...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.jbiomech.2003.12.015

    authors: Robinovitch SN,Brumer R,Maurer J

    更新日期:2004-09-01 00:00:00

  • Interlimb coordination in body-weight supported locomotion: A pilot study.

    abstract::Locomotion involves complex neural networks responsible for automatic and volitional actions. During locomotion, motor strategies can rapidly compensate for any obstruction or perturbation that could interfere with forward progression. In this pilot study, we examined the contribution of interlimb pathways for evoking...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.04.042

    authors: Seiterle S,Susko T,Artemiadis PK,Riener R,Igo Krebs H

    更新日期:2015-08-20 00:00:00

  • Biomechanical effect of rapid mucoperiosteal palatal tissue expansion with the use of osmotic expanders.

    abstract::The comparative study was performed to investigate the biomechanical properties (maximum tangential stiffness, maximum tangential modulus and tensile strength) of expanded mucoperiosteal palatal tissue after rapid expansion regimen correlated with histological findings. Rabbit palatal model was used to correlate the n...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.01.012

    authors: Wysocki M,Kobus K,Szotek S,Kobielarz M,Kuropka P,Będziński R

    更新日期:2011-04-29 00:00:00

  • Force-sharing between cat soleus and gastrocnemius muscles during walking: explanations based on electrical activity, properties, and kinematics.

    abstract::Studying force sharing between synergistic muscles can be useful for understanding the functional significance of musculoskeletal redundancy and the mechanisms underlying the control of synergistic muscles. The purpose of this study was to quantify and explain force sharing between cat soleus (SO) and gastrocnemius (G...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(94)90276-3

    authors: Prilutsky BI,Herzog W,Allinger TL

    更新日期:1994-10-01 00:00:00

  • Biaxial mechanical testing of human sclera.

    abstract::The biomechanical environment of the optic nerve head (ONH), of interest in glaucoma, is strongly affected by the biomechanical properties of sclera. However, there is a paucity of information about the variation of scleral mechanical properties within eyes and between individuals. We thus used biaxial testing to meas...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.02.031

    authors: Eilaghi A,Flanagan JG,Tertinegg I,Simmons CA,Wayne Brodland G,Ross Ethier C

    更新日期:2010-06-18 00:00:00

  • Explicit calibration method and specific device designed for stereoradiography.

    abstract::The three-dimensional geometry of the human spine is noteworthy information that can be obtained by stereoradiographic methods. These methods are based on the identification of anatomical structures in several views which are obtained by rotation of a patient standing on a turntable. Calibration algorithms for compute...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(03)00016-2

    authors: Dumas R,Mitton D,Laporte S,Dubousset J,Steib JP,Lavaste F,Skalli W

    更新日期:2003-06-01 00:00:00

  • Simultaneous shear and pressure sensor array for assessing pressure and shear at foot/ground interface.

    abstract::Foot ulceration is a diabetic complication estimated to result in over $1 billion worth of medical expenses per year in the United States alone. This multifaceted problem involves the response of plantar soft tissue to both external forces applied to the epidermis and internal changes such as vascular supply and neuro...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2005.10.001

    authors: Mackey JR,Davis BL

    更新日期:2006-01-01 00:00:00

  • Realistic virtual intracranial stenting and computational fluid dynamics for treatment analysis.

    abstract::In order to support the decisions of medical experts and to develop better stent designs, the availability of a simulation tool for virtual stenting would be extremely useful. An innovative virtual stenting technique is described in this work, which is directly applicable for complex patient-specific geometries. A bas...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2012.08.047

    authors: Janiga G,Rössl C,Skalej M,Thévenin D

    更新日期:2013-01-04 00:00:00

  • Compressive creep behavior of bovine trabecular bone.

    abstract::There are almost no published data that describe the creep behavior of trabecular bone (at the specimen level), even though the creep behavior of cortical bone has been well documented. In an effort to characterize the creep behavior of trabecular bone and to compare it with that of cortical bone, we performed uniaxia...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章,评审

    doi:10.1016/0021-9290(94)90006-x

    authors: Bowman SM,Keaveny TM,Gibson LJ,Hayes WC,McMahon TA

    更新日期:1994-03-01 00:00:00

  • Longitudinal strain of canine and porcine aortas.

    abstract::The in situ longitudinal strain of canine and porcine aortas was investigated. Marks of black water-resistant ink were placed on the aortas and the axial lengths between the marks were measured in situ and in vitro. When the aortas were cut, the retraction was measured and described by the stretch ratio, which is defi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(94)00091-h

    authors: Han HC,Fung YC

    更新日期:1995-05-01 00:00:00

  • Novel instrumented probe for measuring 3D pressure distribution along the vaginal canal.

    abstract::We developed an intravaginal instrumented probe (covered with a 10×10 matrix of capacitive sensors) for assessing the three-dimensional (3D) spatiotemporal pressure profile of the vaginal canal. The pressure profile was compared to the pelvic floor (PF) digital assessment, and the reliability of the instrument and rep...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.04.035

    authors: Cacciari LP,Pássaro AC,Amorim AC,Geuder M,Sacco ICN

    更新日期:2017-06-14 00:00:00

  • Effects of extracellular fiber architecture on cell membrane shear stress in a 3D fibrous matrix.

    abstract::Interstitial fluid flow has been shown to affect the organization and behavior of cells in 3D environments in vivo and in vitro, yet the forces driving such responses are not clear. Due to the complex architecture of the extracellular matrix (ECM) and the difficulty of measuring fluid flow near cells embedded in it, t...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2006.06.023

    authors: Pedersen JA,Boschetti F,Swartz MA

    更新日期:2007-01-01 00:00:00

  • Accuracy of an optical active-marker system to track the relative motion of rigid bodies.

    abstract::The measurement of relative motion between two moving bones is commonly accomplished for in vitro studies by attaching to each bone a series of either passive or active markers in a fixed orientation to create a rigid body (RB). This work determined the accuracy of motion between two RBs using an Optotrak optical moti...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2006.01.017

    authors: Maletsky LP,Sun J,Morton NA

    更新日期:2007-01-01 00:00:00

  • Elbow and wrist joint contact forces during occupational pick and place activities.

    abstract::A three-dimensional, mathematical model of the elbow and wrist joints, including 15 muscle units, 3 ligaments and 4 joint forces, has been developed. A new strain gauge transducer has been developed to measure functional grip forces. The device measures radial forces divided into six components and forces of up to 250...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(99)00184-0

    authors: Chadwick EK,Nicol AC

    更新日期:2000-05-01 00:00:00

  • Three-dimensional intervertebral kinematics in the healthy young adult cervical spine during dynamic functional loading.

    abstract::The objective of this study was to determine the intervertebral kinematics of the young, healthy cervical spine during dynamic, three-dimensional, functional loading. Intervertebral motion was characterized by the range of motion (ROM) and the helical axis of motion (HAM). Biplane radiographs of the cervical spine wer...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.02.049

    authors: Anderst WJ,Donaldson WF 3rd,Lee JY,Kang JD

    更新日期:2015-05-01 00:00:00

  • The region-dependent dynamic properties of porcine temporomandibular joint disc under unconfined compression.

    abstract::In this study, the dynamic compressive properties in five different regions of the porcine temporomandibular joint (TMJ) disc are investigated over a wide range of loading frequencies. The aim was, thus far, to evaluate the regional difference and the frequency-related effect of the applied load on these properties. E...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2012.11.035

    authors: Fernández P,Jesús Lamela M,Ramos A,Fernández-Canteli A,Tanaka E

    更新日期:2013-02-22 00:00:00

  • A probabilistic orthopaedic population model to predict fatigue-related subacromial geometric variability.

    abstract::Fatigue-related glenohumeral and scapulothoracic kinematic relationships, in addition to morphological characteristics of the scapula and humerus, affect the dimensions of the subacromial space. Each exhibits considerable interpersonal variability, which if only considering the mean, can lead to misleading population ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.12.049

    authors: Chopp-Hurley JN,Langenderfer JE,Dickerson CR

    更新日期:2016-02-29 00:00:00

  • A minimally disruptive technique for measuring intervertebral disc pressure in vitro: application to the cervical spine.

    abstract::A novel technique to measure in vitro disc pressures in human cervical spine specimens was developed. A miniature pressure transducer was used and an insertion technique was designed to minimise artefacts due to insertion. The technique was used to measure the intradiscal pressure in cervical spines loaded in pure axi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(00)00205-0

    authors: Cripton PA,Dumas GA,Nolte LP

    更新日期:2001-04-01 00:00:00

  • The potential influence of the heel counter on internal stress during static standing: a combined finite element and positional MRI investigation.

    abstract::Confinement of the heel due to the counter of the shoe is believed to influence heel pad biomechanics. Using a two-dimensional finite element model of the heel pad and shoe during a simulation of static standing, the aim of this study was to quantify the potential effect of confinement on internal heel pad stress. Non...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.01.004

    authors: Spears IR,Miller-Young JE,Sharma J,Ker RF,Smith FW

    更新日期:2007-01-01 00:00:00

  • Cellular force signal integration through vector logic gates.

    abstract::The multi-signal mechanical environment mammalian cells experience is often unaccounted for in current mechanical stimulation studies. To address this we developed a novel technique to induce dual integrated force inputs, uniaxial stretch and fluid shear stress and present here for the first time a vector logic-gate f...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.12.047

    authors: Steward RL Jr,Tan C,Cheng CM,LeDuc PR

    更新日期:2015-02-26 00:00:00

  • Precision measurements of the RSA method using a phantom model of hip prosthesis.

    abstract::Radiostereometric analysis (RSA) has become one of the recommended techniques for pre-market evaluation of new joint implant designs. In this study we evaluated the effect of repositioning of X-ray tubes and phantom model on the precision of the RSA method. In precision measurements, we utilized mean error of rigid bo...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2003.09.004

    authors: Mäkinen TJ,Koort JK,Mattila KT,Aro HT

    更新日期:2004-04-01 00:00:00

  • Material properties of articular cartilage in the rabbit tibial plateau.

    abstract::The material properties of articular cartilage in the rabbit tibial plateau were determined using biphasic indentation creep tests. Cartilage specimens from matched-pair hind limbs of rabbits approximately 4 months of age and greater than 12 months of age were tested on two locations within each compartment using a cu...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2005.07.017

    authors: Roemhildt ML,Coughlin KM,Peura GD,Fleming BC,Beynnon BD

    更新日期:2006-01-01 00:00:00

  • Microdamage accumulation in the cement layer of hip replacements under flexural loading.

    abstract::Mechanical fatigue of bone cement leading to damage accumulation is implicated in the loosening of cemented hip components. Even though cracks have been identified in autopsy-retrieved mantles, damage accumulation by continuous growth and increase in number of microcracks has not yet been demonstrated experimentally. ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(99)00018-4

    authors: McCormack BA,Prendergast PJ

    更新日期:1999-05-01 00:00:00

  • Specimen dimensions influence the measurement of material properties in tendon fascicles.

    abstract::Stress, strain and modulus are regularly used to characterize material properties of tissue samples. However, when comparing results from different studies it is evident the reported material properties, particularly failure strains, vary hugely. The aim of our study was to characterize how and why specimen length and...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.04.040

    authors: Legerlotz K,Riley GP,Screen HR

    更新日期:2010-08-26 00:00:00

  • The influences of foot placement on lumbopelvic rhythm during trunk flexion motion.

    abstract::Different standing postures could potentially influence trunk biomechanics during task performance. The current study investigated how foot placement, especially stance width and foot angle influenced lumbopelvic rhythm during sagittal trunk flexion motion. Ten participants performed pace controlled sagittally symmetr...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.03.048

    authors: Zhou J,Ning X,Hu B,Dai B

    更新日期:2016-06-14 00:00:00

  • Representative 3D shape of the distal femur, modes of variation and relationship with abnormality of the trochlear region.

    abstract::The anatomy of the distal femur has a predominant influence on the mechanics of both patello- and tibio-femoral joints. Especially, the morphological degeneration of the trochlear region dramatically affects the overall knee biomechanics and, from a clinical point of view, the staging of such a degeneration is fundame...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.07.008

    authors: Cerveri P,Belfatto A,Manzotti A

    更新日期:2019-09-20 00:00:00

  • The effect of chemically defined medium on spontaneous calcium signaling of in situ chondrocytes during long-term culture.

    abstract::Chemically defined serum-free medium has been shown to better maintain the mechanical integrity of articular cartilage explants than serum-supplemented medium during long-term in vitro culture, but little is known about its effect on cellular mechanisms. We hypothesized that the chemically defined culture medium could...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.02.005

    authors: Zhou Y,Park M,Cheung E,Wang L,Lu XL

    更新日期:2015-04-13 00:00:00

  • Influence of muscle anatomical cross-sectional area on the moment arm length of the triceps brachii muscle at the elbow joint.

    abstract::The purpose of this study was to test the hypothesis that the musculotendon moment arm length is affected by the muscle anatomical cross-sectional area. The moment arm length of the triceps brachii (TB) muscle at 30°, 50°, 70°, 90°, 110° elbow flexion positions was measured in sagittal magnetic resonance images (MRI) ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.06.013

    authors: Sugisaki N,Wakahara T,Miyamoto N,Murata K,Kanehisa H,Kawakami Y,Fukunaga T

    更新日期:2010-10-19 00:00:00

  • Effects of a sustained extension on arterial growth and remodeling: a theoretical study.

    abstract::Three recent studies reveal that the unloaded length of a carotid artery increases significantly and rapidly in response to sustained increases in axial extension. Moreover, such lengthening involves an "unprecedented" increase in the rate of turnover of cells and matrix. Although current data are not sufficient for d...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2004.06.017

    authors: Gleason RL,Humphrey JD

    更新日期:2005-06-01 00:00:00

  • A dual optimization method for the material parameter identification of a biphasic poroviscoelastic hydrogel: Potential application to hypercompliant soft tissues.

    abstract::A dual-indentation creep and stress relaxation methodology was developed and validated for the material characterization of very soft biological tissue within the framework of the biphasic poroviscoelastic (BPVE) constitutive model. Agarose hydrogel, a generic porous medium with mobile fluid, served as a mechanical ti...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2005.07.019

    authors: Olberding JE,Francis Suh JK

    更新日期:2006-01-01 00:00:00