In-vivo analysis of thoracic mechanical response under belt loading: the role of body mass index in thorax stiffness.

Abstract:

:Thoracic injuries are a major cause of mortality in frontal collisions, especially for elderly and obese people. Car occupant individual characteristics like BMI are known to influence human vulnerability in crashes. In the present study, thoracic mechanical response of volunteers quantified by optical method was linked to individual characteristics. 13 relaxed volunteers of different anthropometries, genders and age were submitted to non-injurious sled tests (4 g, 8 km/h) with a sled buck representing the environment of a front passenger restrained by a 3-point belt. A resulting shoulder belt force was computed using the external and internal shoulder belt loads and considering shoulder belt geometry. The mid sternal deflection was calculated as the distance variation between markers placed at mid-sternum and the 7th vertebra spinous process of the subject. Force-deflection curves were constructed using resulting shoulder belt force and midsternal deflection. Average maximum chest compression was 7.9±2.3% and no significant difference was observed between overweight subjects (BMI≥25 kg/m²) and normal subject (BMI<25 kg/m²). The overweight subjects exhibited significantly greater resultant belt forces than normal subjects (715±132 N vs. 527±111 N, p<0.05), higher effective stiffness (30.9±10.6N/mm vs. 19.6±8.9 N/mm, p<0.05) and lower dynamic stiffness (42.7±8.71 N/mm vs. 61.7±15.5 N/mm, p<0.05).

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Poulard D,Bermond F,Compigne S,Bruyère K

doi

10.1016/j.jbiomech.2012.12.021

subject

Has Abstract

pub_date

2013-03-15 00:00:00

pages

883-9

issue

5

eissn

0021-9290

issn

1873-2380

pii

S0021-9290(12)00751-8

journal_volume

46

pub_type

临床试验,杂志文章
  • The influence of strain rate on adaptive bone remodelling.

    abstract::Bending and compressive loads were applied intermittently at 0.5 Hz through implants chronically inserted into the radius and ulna of experimental sheep. The plane of bending was the same as that imposed during locomotion. The principal variables of the artificial strain regime were the peak strains and strain rates, ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(82)90092-6

    authors: O'Connor JA,Lanyon LE,MacFie H

    更新日期:1982-01-01 00:00:00

  • Effects of femoral component placement on the balancing of a total knee at surgery.

    abstract::Misalignment and soft-tissue imbalance in total knee arthroplasty (TKA) can cause discomfort, pain, inadequate motion and instability that may require revision surgery. Balancing can be defined as equal collateral ligament tensions or equal medial and lateral compartmental forces during the flexion range. Our goal was...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.01.056

    authors: Zapata G,Sanz-Pena I,Verstraete M,Walker PS

    更新日期:2019-03-27 00:00:00

  • A multipurpose muscle ergometer.

    abstract::A fast (0.1 mm steps within 2 ms), strong (40 N continuously) and accurate (resolution 0.002 N and 1.0 micron) muscle ergometer was developed to test dynamic and static properties of mammalian muscle. Both for twitches and for tetani isometric, isokinetic and isotonic contractions can be measured accurately. Force-vel...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(87)90312-5

    authors: Woittiez RD,Brand C,de Haan A,Hollander AP,Huijing PA,van der Tak R,Rijnsburger WH

    更新日期:1987-01-01 00:00:00

  • Assessment of mechanical properties of articular cartilage with quantitative three-dimensional ultrashort echo time (UTE) cones magnetic resonance imaging.

    abstract::Conventional magnetic resonance imaging (MRI) is not capable of detecting signal from the deep cartilage due to its short transverse relaxation time (T2). Moreover, several quantitative MRI techniques are significantly influenced by the magic angle effect. The combinations of ultrashort echo time (UTE) MRI with magnet...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.110085

    authors: Namiranian B,Jerban S,Ma Y,Dorthe EW,Masoud-Afsahi A,Wong J,Wei Z,Chen Y,D'Lima D,Chang EY,Du J

    更新日期:2020-12-02 00:00:00

  • Optimization of intravascular shear stress assessment in vivo.

    abstract::The advent of microelectromechanical systems (MEMS) sensors has enabled real-time wall shear stress (WSS) measurements with high spatial and temporal resolution in a 3-D bifurcation model. To optimize intravascular shear stress assessment, we evaluated the feasibility of catheter/coaxial wire-based MEMS sensors in the...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.04.021

    authors: Ai L,Yu H,Takabe W,Paraboschi A,Yu F,Kim ES,Li R,Hsiai TK

    更新日期:2009-07-22 00:00:00

  • A comparison of Coulomb and pseudo-Coulomb friction implementations: Application to the table contact phase of gymnastics vaulting.

    abstract::In the table contact phase of gymnastics vaulting both dynamic and static friction act. The purpose of this study was to develop a method of simulating Coulomb friction that incorporated both dynamic and static phases and to compare the results with those obtained using a pseudo-Coulomb implementation of friction when...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.07.022

    authors: Jackson MI,Hiley MJ,Yeadon MR

    更新日期:2011-10-13 00:00:00

  • Morphing methods to parameterize specimen-specific finite element model geometries.

    abstract::Shape plays an important role in determining the biomechanical response of a structure. Specimen-specific finite element (FE) models have been developed to capture the details of the shape of biological structures and predict their biomechanics. Shape, however, can vary considerably across individuals or change due to...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.08.036

    authors: Sigal IA,Yang H,Roberts MD,Downs JC

    更新日期:2010-01-19 00:00:00

  • A fully nonlinear viscohyperelastic model for the brain tissue applicable to dynamic rates.

    abstract::Understanding the mechanical response of the brain to external loadings is of critical importance in investigating the pathological conditions of this tissue during injurious conditions. Such injurious loadings may occur at high rates, for example among others, during road traffic or sport accidents, falls, or due to ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.01.007

    authors: Samadi-Dooki A,Voyiadjis GZ

    更新日期:2019-02-14 00:00:00

  • Concurrent validity and reliability of a mobile tracking technology to measure angular and linear movements of the neck.

    abstract::The neck can be moved in six degrees of freedom. Current 3D-optoelectronic motion-capture systems capable of measuring these movements are inappropriate for use in clinical practice because they are stationary, expensive and time-consuming. We therefore developed a less complex 3D-tracking technology based on Steam®VR...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.109340

    authors: Sommer BB,Weisenhorn M,Ernst MJ,Meichtry A,Rast FM,Kleger D,Schmid P,Lünenburger L,Bauer CM

    更新日期:2019-11-11 00:00:00

  • Biotribology of a mobile bearing posterior stabilised knee design--effect of motion restraint on wear, tibio-femoral kinematics and particles.

    abstract::The objective of our study was to evaluate the impact of a biphaseal anterior-posterior (AP) and internal-external (IE) motion restraint system on the wear behaviour, tibio-femoral kinematics and particle release of a mobile bearing posterior stabilised knee design in comparison to the widely used linear restraint. in...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.04.020

    authors: Grupp TM,Schroeder C,Kyun Kim T,Miehlke RK,Fritz B,Jansson V,Utzschneider S

    更新日期:2014-07-18 00:00:00

  • A piecewise mass-spring-damper model of the human breast.

    abstract::Previous models to predict breast movement whilst performing physical activities have, erroneously, assumed uniform elasticity within the breast. Consequently, the predicted displacements have not yet been satisfactorily validated. In this study, real time motion capture of the natural vibrations of a breast that foll...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.11.027

    authors: Cai Y,Chen L,Yu W,Zhou J,Wan F,Suh M,Chow DH

    更新日期:2018-01-23 00:00:00

  • Evaluation of human nasal cartilage nonlinear and rate dependent mechanical properties.

    abstract::Nasal reconstruction frequently requires donor cartilage and tissue, and ideally, donor tissue will closely emulate native nasal cartilage mechanics. Tissue engineering scaffolds, especially 3D printed scaffolds, have been proposed for nasal reconstruction, and the success of these constructs may depend on how well sc...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.109549

    authors: Chang B,Reighard C,Flanagan C,Hollister S,Zopf D

    更新日期:2020-02-13 00:00:00

  • Study of tumor blood perfusion and its variation due to vascular normalization by anti-angiogenic therapy based on 3D angiogenic microvasculature.

    abstract::The coupling of intravascular and interstitial flow is a distinct feature of tumor microcirculation, due to high vessel permeability, low osmotic pressure gradient and absence of functional lymphatic system inside tumors. We have previously studied the tumor microcirculation by using a 2D coupled model. In this paper,...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.01.009

    authors: Wu J,Long Q,Xu S,Padhani AR

    更新日期:2009-04-16 00:00:00

  • Estimation of finger muscle tendon tensions and pulley forces during specific sport-climbing grip techniques.

    abstract::The present work displayed the first quantitative data of forces acting on tendons and pulleys during specific sport-climbing grip techniques. A three-dimensional static biomechanical model was used to estimate finger muscle tendon and pulley forces during the "slope" and the "crimp" grip. In the slope grip the finger...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2005.08.027

    authors: Vigouroux L,Quaine F,Labarre-Vila A,Moutet F

    更新日期:2006-01-01 00:00:00

  • Sensitivity of flow patterns in aneurysms on the anterior communicating artery to anatomic variations of the cerebral arterial network.

    abstract::Recent studies raised increasing concern about the reliability of computer models in reproducing in vivo hemodynamics in cerebral aneurysms. Boundary condition problem is among the most frequently addressed issues since three-dimensional (3-D) modeling is usually restricted to local arterial segments. The present stud...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.09.031

    authors: Liang F,Liu X,Yamaguchi R,Liu H

    更新日期:2016-11-07 00:00:00

  • Evaluation of left ventricular function based on simulated systolic flow dynamics computed from regional wall motion.

    abstract::Left ventricular (LV) chamber flow is undoubtedly influenced by the time-dependent regional motion of the LV wall. In an attempt to obtain diagnostic parameters based on LV chamber flow, we computed the LV chamber, two-dimensional systolic velocity and pressure distribution for two right anterior oblique (RAO) ventric...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(94)90201-1

    authors: Schoephoerster RT,Silva CL,Ray G

    更新日期:1994-02-01 00:00:00

  • Conservation of energy in competitive swimming.

    abstract::Energy conservation in swimming is formulated in terms of four functions of the swim speed v: the consumed power K, the mechanical power P used for horizontal propulsion, the remaining expended mechanical power N, and the thermal power loss H. K is well-known (from VO2) and P = FDv, where the drag force FD is not know...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(94)00143-r

    authors: Brandt RA,Pichowsky MA

    更新日期:1995-08-01 00:00:00

  • Comparing different approaches for determining joint torque parameters from isovelocity dynamometer measurements.

    abstract::Strength, or maximum joint torque, is a fundamental factor governing human movement, and is regularly assessed for clinical and rehabilitative purposes as well as for research into human performance. This study aimed to identify the most appropriate protocol for fitting a maximum voluntary torque function to experimen...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.11.024

    authors: Forrester SE,Yeadon MR,King MA,Pain MT

    更新日期:2011-03-15 00:00:00

  • Non-invasive quantification of peripheral arterial volume distensibility and its non-linear relationship with arterial pressure.

    abstract::Arterial wall function is associated with different physiological and clinical factors. Changes in arterial pressure cause major changes in the arterial wall. This study presents a simple non-invasive method to quantify arterial volume distensibility changes with different arterial pressures. The electrocardiogram, fi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.02.011

    authors: Zheng D,Murray A

    更新日期:2009-05-29 00:00:00

  • In vivo knee joint loading and kinematics before and after ACL transection in an animal model.

    abstract::Osteoarthritis (OA) is typically diagnosed in humans in its final stage when joint movement becomes painful. Clinical information about the onset and the mechanisms triggering the degenerative responses are virtually non-existent. However, research on animal models of experimental OA shows that joint adaptations assoc...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(97)00119-x

    authors: Hasler EM,Herzog W,Leonard TR,Stano A,Nguyen H

    更新日期:1998-03-01 00:00:00

  • Twenty-fold difference in hemodynamic wall shear stress between murine and human aortas.

    abstract::Endothelial cells regulate vascular tone and mural remodelling in a shear-dependent manner that is commonly assumed to keep wall shear stress constant across arteries and species. Allometric arguments show that aortic flow velocity is constant across species, a deduction that is consistent with much experimental data,...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2006.07.020

    authors: Weinberg PD,Ross Ethier C

    更新日期:2007-01-01 00:00:00

  • Mechanisms relating force and high-frequency stiffness in skeletal muscle.

    abstract::Muscle stiffness increases faster than muscle force during the rising phase of a tetanic contraction, and decreases more slowly during the falling phase. Different models of the stiffness arising from series, parallels, and crossbridge elasticity were compared to determine whether they could account quantitatively for...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章,评审

    doi:10.1016/0021-9290(90)90037-4

    authors: Bobet J,Stein RB,Oğuztöreli MN

    更新日期:1990-01-01 00:00:00

  • Mechanical and metabolic requirements for active lateral stabilization in human walking.

    abstract::Walking appears to be passively unstable in the lateral direction, requiring active feedback control for stability. The central nervous system may control stability by adjusting medio-lateral foot placement, but potentially with a metabolic cost. This cost increases with narrow steps and may affect the preferred step ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2003.06.002

    authors: Donelan JM,Shipman DW,Kram R,Kuo AD

    更新日期:2004-06-01 00:00:00

  • Differences in stretch-shortening cycle and residual force enhancement between muscles.

    abstract::It has been suggested that cross bridge kinetics and residual force enhancement (RFE) affect force in the stretch-shortening cycle (SSC). Because cross bridge kinetics and titin isoforms, which are thought to be related to RFE, differ between muscles, the SSC effect may be also muscle-dependent. Thus, we compared the ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.110040

    authors: Fukutani A,Herzog W

    更新日期:2020-11-09 00:00:00

  • Musculo-articular modelling of the triceps brachii.

    abstract::With the aim of proposing modelling equations for the length, force and shortening velocity of the triceps brachii, an X-ray and biomechanical study was carried out on the elbow joint. Two series of three upper right limbs removed from cadavers were used. It allowed us to situate the articular rotational axis of the e...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(95)00032-1

    authors: Gerbeaux M,Turpin E,Lensel-Corbeil G

    更新日期:1996-02-01 00:00:00

  • Flow behaviour in an asymmetric compliant experimental model for abdominal aortic aneurysm.

    abstract::An experimental study was carried out on asymmetrical abdominal aortic aneurysm (AAA) to analyse the physiological flows involved. Velocity measurements were performed using particle image velocimetry. Resting and exercise flow rates were investigated in models with rigid and compliant walls to assess the parameters a...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2006.11.017

    authors: Deplano V,Knapp Y,Bertrand E,Gaillard E

    更新日期:2007-01-01 00:00:00

  • Kinematic analysis of video-captured falls experienced by older adults in long-term care.

    abstract::Falls cause 95% of hip and wrist fractures and 60% of head injuries in older adults. Risk for such injuries depends in part on velocity at contact, and the time available during the fall to generate protective responses. However, we have no information on the impact velocities and durations of falls in older adults. W...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.02.025

    authors: Choi WJ,Wakeling JM,Robinovitch SN

    更新日期:2015-04-13 00:00:00

  • A dynamic model of the forearm including fatigue.

    abstract::A biomechanical model of the forearm, consisting of 61 muscle-tendon systems or tendons and 8 sections, is presented. The model can be used to calculate the muscle forces when resultant of the external forces and the motion is known. Calculations are based on constraints of muscle forces, joint forces, contact forces,...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(01)00009-4

    authors: Freund J,Takala EP

    更新日期:2001-05-01 00:00:00

  • Knee kinematics and kinetics during shuttle run cutting: comparison of the assessments performed with and without the point cluster technique.

    abstract::The differences between the assessments performed with and without the point cluster technique (PCT) for knee joint motions during the high-risk movements associated with non-contact anterior cruciate ligament (ACL) injuries have not been reported. This study aims to examine the differences between PCT and non-PCT ass...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.05.001

    authors: Ishii H,Nagano Y,Ida H,Fukubayashi T,Maruyama T

    更新日期:2011-07-07 00:00:00

  • Influence of muscle anatomical cross-sectional area on the moment arm length of the triceps brachii muscle at the elbow joint.

    abstract::The purpose of this study was to test the hypothesis that the musculotendon moment arm length is affected by the muscle anatomical cross-sectional area. The moment arm length of the triceps brachii (TB) muscle at 30°, 50°, 70°, 90°, 110° elbow flexion positions was measured in sagittal magnetic resonance images (MRI) ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.06.013

    authors: Sugisaki N,Wakahara T,Miyamoto N,Murata K,Kanehisa H,Kawakami Y,Fukunaga T

    更新日期:2010-10-19 00:00:00