Propulsive joint powers track with sensor-derived angular velocity: A potential tool for lab-less gait retraining.

Abstract:

:Lower propulsive joint powers, particularly at the ankle, are often observed in older compared to young adults. Interventions to increase joint powers often require labs with motion capture and force treadmill technology. Translating these interventions out of the lab requires identifying portable measures that track (i.e., strongly correlate with) changes in joint powers. The purpose of this study was to determine if kinematics collected using inertial measurement units (IMUs) correlate with propulsive joint powers calculated using inverse dynamics. We collected data simultaneously with motion capture, force plates, and IMU sensors as young and older adults walked at varying speeds overground in a laboratory. Hip, knee, and ankle joint powers were calculated using inverse dynamics and positive peaks in the second half of stance were identified as the propulsive powers of interest. Raw IMU gyroscope data were oriented to a functional medial-lateral axis and peaks in the second half of stance were identified for segment (thigh, shank, foot) and joint (hip, knee, ankle) angular velocities. Pearson correlation coefficients were calculated between peak joint powers and peak angular velocities. We identified significant (all p < 0.001) correlations between hip joint power and hip and thigh angular velocities (r = 0.80-0.83) and between ankle joint power and ankle, shank, and foot angular velocities (r = 0.77-0.89). Correlation strength was similar between young and older adults and between segment and joint angular velocities. These results suggest that changes in joint powers longitudinally or over the course of an intervention could be tracked using a minimal set of wearable sensors.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Hafer JF,Zernicke RF

doi

10.1016/j.jbiomech.2020.109821

subject

Has Abstract

pub_date

2020-06-09 00:00:00

pages

109821

eissn

0021-9290

issn

1873-2380

pii

S0021-9290(20)30244-X

journal_volume

106

pub_type

杂志文章
  • The development of an improved physical surrogate model of the human spinal cord--tension and transverse compression.

    abstract::To prevent spinal cord injury, optimize treatments for it, and better understand spinal cord pathologies such as spondylotic myelopathy, the interaction between the spinal column and the spinal cord during injury and pathology must be understood. The spinal cord is a complex and very soft tissue that changes propertie...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.01.036

    authors: Kroeker SG,Morley PL,Jones CF,Bilston LE,Cripton PA

    更新日期:2009-05-11 00:00:00

  • In vivo measurement of ACL length and relative strain during walking.

    abstract::Although numerous studies have addressed the effects of ACL injury and reconstruction on knee joint motion, there is currently little data available describing in vivo ACL strain during activities of daily living. Data describing in vivo ACL strain during activities such as gait is critical to understanding the biomec...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.jbiomech.2012.10.031

    authors: Taylor KA,Cutcliffe HC,Queen RM,Utturkar GM,Spritzer CE,Garrett WE,DeFrate LE

    更新日期:2013-02-01 00:00:00

  • Modification of spastic gait through mechanical damping.

    abstract::The effect of dissipative mechanical loads on spastic gait has been studied, to evaluate the feasibility of using mechanically damped orthoses to effect functional improvements in the gait of spastic patients. This concept is based on a hypothesis citing uninhibited, velocity-dependent stretch reflexes as a possible c...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(85)90278-7

    authors: Maki BE,Rosen MJ,Simon SR

    更新日期:1985-01-01 00:00:00

  • Is Achilles tendon compliance optimised for maximum muscle efficiency during locomotion?

    abstract::Tendon elasticity is important for economical locomotion; however it is unknown whether tendon stiffness is appropriate to achieve an optimal efficiency in various muscles. Here we test the hypothesis that the Achilles tendon is of an appropriate stiffness to maximise medial gastrocnemius muscle efficiency during loco...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2006.07.025

    authors: Lichtwark GA,Wilson AM

    更新日期:2007-01-01 00:00:00

  • β-Tricalcium phosphate for bone replacement: stability and integration in sheep.

    abstract::Implants of microporous β-tricalcium phosphate (β-TCP) were developed for primarily stable supply of bone defects. A consistent stability over the healing period should be retained in sheep. β-TCP cylindrical shaped implants, with 7 mm diameter, 25 mm length, medium pore diameter 5 μm and 40% porosity were developed. ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.01.040

    authors: Mayr HO,Suedkamp NP,Hammer T,Hein W,Hube R,Roth PV,Bernstein A

    更新日期:2015-04-13 00:00:00

  • Comparison of three local frame definitions for the kinematic analysis of the fingers and the wrist.

    abstract::Because the hand is a complex poly-articular limb, numerous methods have been proposed to investigate its kinematics therefore complicating the comparison between studies and the methodological choices. With the objective of overcoming such issues, the present study compared the effect of three local frame definitions...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.05.025

    authors: Goislard de Monsabert B,Visser JM,Vigouroux L,Van der Helm FC,Veeger HE

    更新日期:2014-08-22 00:00:00

  • Insertion of microneedles into skin: measurement and prediction of insertion force and needle fracture force.

    abstract::As a hybrid between a hypodermic needle and transdermal patch, we have used microfabrication technology to make arrays of micron-scale needles that transport drugs and other compounds across the skin without causing pain. However, not all microneedle geometries are able to insert into skin at reasonable forces and wit...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2003.12.010

    authors: Davis SP,Landis BJ,Adams ZH,Allen MG,Prausnitz MR

    更新日期:2004-08-01 00:00:00

  • An expression relating breaking stress and density of trabecular bone.

    abstract::Bone mineral density (BMD) is the principal diagnostic tool used in clinical settings to diagnose and monitor osteoporosis. Experimental studies on ex vivo bone samples from multiple skeletal locations have been used to propose that their breaking stress bears a power-law relationship to volumetric BMD, with a locatio...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2003.12.001

    authors: Rajapakse CS,Thomsen JS,Espinoza Ortiz JS,Wimalawansa SJ,Ebbesen EN,Mosekilde L,Gunaratne GH

    更新日期:2004-08-01 00:00:00

  • Different methods to estimate total power and its components during lifting.

    abstract::A more fundamental understanding about the act of manual lifting can be provided by the assessment of the total production of power and the power generated in joints. The present study is concerned with the validity of the estimations of these parameters. Four subjects lifted an 18.8 kg load while they were filmed and...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(92)90045-3

    authors: de Looze MP,Bussmann JB,Kingma I,Toussaint HM

    更新日期:1992-09-01 00:00:00

  • Peristaltic transport of blood: Casson model--II.

    abstract::The problem of peristaltic transport of blood in a uniform and non-uniform tube has been investigated, under zero Reynolds number and long wavelength approximation. Blood is represented by a two-layered fluid model consisting of a central layer of suspension of all erythrocytes, etc., assumed to be a Casson fluid, and...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(84)90140-4

    authors: Srivastava LM,Srivastava VP

    更新日期:1984-01-01 00:00:00

  • Sagittal plane rotation center of lower lumbar spine during a dynamic weight-lifting activity.

    abstract::This study investigated the center of rotation (COR) of the intervertebral segments of the lower lumbar spine (L4-L5 and L5-S1 segments) in sagittal plane during a weight-lifting (3.6 kg in each hand) extension activity performed with the pelvis constrained. Seven healthy subjects were studied using a dual fluoroscopi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.12.029

    authors: Liu Z,Tsai TY,Wang S,Wu M,Zhong W,Li JS,Cha T,Wood K,Li G

    更新日期:2016-02-08 00:00:00

  • A computational fluid-structure interaction analysis of a fiber-reinforced stentless aortic valve.

    abstract::The importance of the aortic root compliance in the aortic valve performance has most frequently been ignored in computational valve modeling, although it has a significant contribution to the functionality of the valve. Aortic root aneurysm or (calcific) stiffening severely affects the aortic valve behavior and, cons...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(02)00448-7

    authors: De Hart J,Baaijens FP,Peters GW,Schreurs PJ

    更新日期:2003-05-01 00:00:00

  • Predictive equations to estimate spinal loads in symmetric lifting tasks.

    abstract::Response surface methodology is used to establish robust and user-friendly predictive equations that relate responses of a complex detailed trunk finite element biomechanical model to its input variables during sagittal symmetric static lifting activities. Four input variables (thorax flexion angle, lumbar/pelvis rati...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.08.028

    authors: Arjmand N,Plamondon A,Shirazi-Adl A,Larivière C,Parnianpour M

    更新日期:2011-01-04 00:00:00

  • Age-related and regional differences in the stress-strain and stress-relaxation behaviours of the rat incisor periodontal ligament.

    abstract::Groups of rats were killed at 2, 6, 12, and 24 months of age. From dissected left and right mandibles in each rat, three pairs of transverse sections were cut at the incisal, middle, and basal regions of the incisor. One section in each pair was loaded until failure and a stress-strain curve for the periodontal ligame...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2003.11.013

    authors: Komatsu K,Shibata T,Shimada A,Viidik A,Chiba M

    更新日期:2004-07-01 00:00:00

  • Index-matched measurements of the effect of cartilaginous rings on tracheobronchial flow.

    abstract::We present a comparison of the flow characteristics in an idealized smooth trachea model and a second model which has a roughness simulating cartilaginous rings. We use refractive index-matched particle image velocimetry (PIV) to measure the velocity field in a two-generation model of the trachea and main bronchi. The...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.03.043

    authors: Bocanegra Evans H,Castillo L

    更新日期:2016-06-14 00:00:00

  • Functional imaging using computational fluid dynamics to predict treatment success of mandibular advancement devices in sleep-disordered breathing.

    abstract::Mandibular advancement devices (MADs) have emerged as a popular alternative for the treatment of sleep-disordered breathing. These devices bring the mandibula forward in order to increase upper airway (UA) volume and prevent total UA collapse during sleep. However, the precise mechanism of action appears to be quite c...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.jbiomech.2007.06.022

    authors: De Backer JW,Vanderveken OM,Vos WG,Devolder A,Verhulst SL,Verbraecken JA,Parizel PM,Braem MJ,Van de Heyning PH,De Backer WA

    更新日期:2007-01-01 00:00:00

  • Effect of the "squat protective response" on impact velocity during backward falls.

    abstract::Risk for injury during a fall depends on the position and velocity of the body segments at the moment of impact. One technique for reducing impact velocity is to absorb energy in the lower extremity muscles during descent, as occurs during squatting or sitting. However, the protective value of this response may depend...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.jbiomech.2003.12.015

    authors: Robinovitch SN,Brumer R,Maurer J

    更新日期:2004-09-01 00:00:00

  • Direct calculation of the surface-to-volume ratio for human cancellous bone.

    abstract::There are many diseases which cause detrimental changes in the trabecular structure of cancellous bone, leading to mechanical failure of the tissue. One approach to understanding the mechanisms of these diseases is to create idealized models that recreate the morphology of the tissue. This paper presents a partial dev...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(93)90057-l

    authors: Fyhrie DP,Fazzalari NL,Goulet R,Goldstein SA

    更新日期:1993-08-01 00:00:00

  • Planar biaxial characterization of diseased human coronary and carotid arteries for computational modeling.

    abstract::Computational models have the potential to provide precise estimates of stresses and strains associated with sites of coronary plaque rupture. However, lack of adequate mathematical description of diseased human vessel wall mechanical properties is hindering computational accuracy. The goal of this study is to charact...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.11.019

    authors: Kural MH,Cai M,Tang D,Gwyther T,Zheng J,Billiar KL

    更新日期:2012-03-15 00:00:00

  • The utility of an empirically derived co-activation ratio for muscle force prediction through optimization.

    abstract::Biomechanical optimization models that apply efficiency-based objective functions often underestimate or negate antagonist co-activation. Co-activation assists movement control, joint stabilization and limb stiffness and should be carefully incorporated into models. The purposes of this study were to mathematically de...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.02.077

    authors: Brookham RL,Middlebrook EE,Grewal TJ,Dickerson CR

    更新日期:2011-05-17 00:00:00

  • Validation of the greater trochanter method with radiographic measurements of frontal plane hip joint centers and knee mechanical axis angles and two other hip joint center methods.

    abstract::Several motion capture methods exist for predicting hip joint centers (HJC). These methods include regression models, functional joints, and projections from greater trochanters. While regression and functional methods have been compared to imaging techniques, the TROCH method has not been previously validated. The pu...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.06.013

    authors: Bennett HJ,Shen G,Weinhandl JT,Zhang S

    更新日期:2016-09-06 00:00:00

  • Mathematical model of the human ankle joint.

    abstract::It has been suspected that the mechanical environment in which a particular joint functions has an effect on the initiation or progression of degenerative joint disease. The objective of this study is to define the mechanical environment of the ankle joint, specifically, the contact areas and pressure distributions, t...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(83)90132-x

    authors: Wynarsky GT,Greenwald AS

    更新日期:1983-01-01 00:00:00

  • Evaluation of cross-sectional geometry and mass density distributions of humans and laboratory animals using computerized tomography.

    abstract::The purpose of this study was to determine the cross-sectional geometry and mass density distribution of a young porcine subject using the X-ray computerized tomographic (CT) method and to perform a comparative study of anatomical features of this subject and a 3 yr old female child specimen. The cross-sectional CT sc...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(83)90006-4

    authors: Huang HK,Suarez FR

    更新日期:1983-01-01 00:00:00

  • Non-invasive determination of cartilage thickness throughout joint surfaces using magnetic resonance imaging.

    abstract::Data on articular cartilage thickness in the living are important for the design for computer models, aimed at preoperatively assessing the effect of surgical procedures on joint contact and load transmission, and for the calculation of cartilage material properties from its deformational behavior as determined during...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(97)81146-3

    authors: Eckstein F,Adam C,Sittek H,Becker C,Milz S,Schulte E,Reiser M,Putz R

    更新日期:1997-03-01 00:00:00

  • Tissue and cellular morphological changes in growth plate explants under compression.

    abstract::The mechanisms by which mechanical loading may alter bone development within growth plates are still poorly understood. However, several growth plate cell or tissue morphological parameters are associated with both normal and mechanically modulated bone growth rates. The aim of this study was to quantify in situ the t...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.05.010

    authors: Amini S,Veilleux D,Villemure I

    更新日期:2010-09-17 00:00:00

  • The elastic behavior of the urinary bladder for large deformations.

    abstract::The purpose of this paper is to investigate the theoretical basis for the pressure-distension behavior of the urinary bladder. A finite strain theory is developed for hollow spherical structures and it is shown that the Treloar model is a good prototype only for rubber balloons. The pressure-extension ratio relationsh...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(83)90055-6

    authors: Regnier CH,Kolsky H,Richardson PD,Ghoniem GM,Susset JG

    更新日期:1983-01-01 00:00:00

  • Estimation of gait kinematics and kinetics from inertial sensor data using optimal control of musculoskeletal models.

    abstract::Inertial sensing enables field studies of human movement and ambulant assessment of patients. However, the challenge is to obtain a comprehensive analysis from low-quality data and sparse measurements. In this paper, we present a method to estimate gait kinematics and kinetics directly from raw inertial sensor data pe...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.07.022

    authors: Dorschky E,Nitschke M,Seifer AK,van den Bogert AJ,Eskofier BM

    更新日期:2019-10-11 00:00:00

  • Evaluation of brain-skull interface modelling approaches on the prediction of acute subdural hematoma in the elderly.

    abstract::Acute subdural hematoma (ASDH) in the elderly is currently a matter of concern due to the growing number of the aging population and their higher incident rate compared to the younger adults. Computational head models that can replicate this age-related injury pattern are valuable tools to help addressing this concern...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109787

    authors: Zhou Z,Li X,Kleiven S

    更新日期:2020-05-22 00:00:00

  • Normal and shear stresses influence the spatial distribution of intracellular adhesion molecule-1 expression in human umbilical vein endothelial cells exposed to sudden expansion flow.

    abstract::Patterns in cell adhesion molecule expression by endothelial cells may play a role in atherogenesis. Previous studies have shown dependence of intracellular adhesion molecule-1 (ICAM-1) expression in human umbilical vein endothelial cells (HUVEC) on shear stress and have indirectly linked ICAM-1 expression to spatial ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2005.02.002

    authors: McKinney VZ,Rinker KD,Truskey GA

    更新日期:2006-01-01 00:00:00

  • Non-Newtonian blood flow in human right coronary arteries: steady state simulations.

    abstract::This study looks at blood flow through four different right coronary arteries, which have been reconstructed from bi-plane angiograms. Five non-Newtonian blood models, as well as the usual Newtonian model of blood viscosity, are used to study the wall shear stress in each of these arteries at a particular point in the...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2003.09.016

    authors: Johnston BM,Johnston PR,Corney S,Kilpatrick D

    更新日期:2004-05-01 00:00:00