Articular contact in a three-dimensional model of the knee.

Abstract:

:This study is aimed at the analysis of articular contact in a three-dimensional mathematical model of the human knee-joint. In particular the effect of articular contact on the passive motion characteristics is assessed in relation to experimentally obtained joint kinematics. Two basically different mathematical contact descriptions were compared for this purpose. One description was for rigid contact and one for deformable contact. The description of deformable contact is based on a simplified theory for contact of a thin elastic layer on a rigid foundation. The articular cartilage was described either as a linear elastic material or as a non-linear elastic material. The contact descriptions were introduced in a mathematical model of the knee. The locations of the ligament insertions and the geometry of the articular surfaces were obtained from a joint specimen of which experimentally determined kinematic data were available, and were used as input for the model. The ligaments were described by non-linear elastic line elements. The mechanical properties of the ligaments and the articular cartilage were derived from literature data. Parametric model evaluations showed that, relative to rigid articular contact, the incorporation of deformable contact did not alter the motion characteristics in a qualitative sense, and that the quantitative changes were small. Variation of the elasticity of the elastic layer revealed that decreasing the surface stiffness caused the ligaments to relax and, as a consequence, increased the joint laxity, particularly for axial rotation. The difference between the linear and the non-linear deformable contact in the knee model was very small for moderate loading conditions. The motion characteristics simulated with the knee model compared very well with the experiments. It is concluded that for simulation of the passive motion characteristics of the knee, the simplified description for contact of a thin linear elastic layer on a rigid foundation is a valid approach when aiming at the study of the motion characteristics for moderate loading conditions. With deformable contact in the knee model, geometric conformity between the surfaces can be modelled as opposed to rigid contact which assumed only point contact.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Blankevoort L,Kuiper JH,Huiskes R,Grootenboer HJ

doi

10.1016/0021-9290(91)90019-j

subject

Has Abstract

pub_date

1991-01-01 00:00:00

pages

1019-31

issue

11

eissn

0021-9290

issn

1873-2380

pii

0021-9290(91)90019-J

journal_volume

24

pub_type

杂志文章
  • Conservation of energy in competitive swimming.

    abstract::Energy conservation in swimming is formulated in terms of four functions of the swim speed v: the consumed power K, the mechanical power P used for horizontal propulsion, the remaining expended mechanical power N, and the thermal power loss H. K is well-known (from VO2) and P = FDv, where the drag force FD is not know...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(94)00143-r

    authors: Brandt RA,Pichowsky MA

    更新日期:1995-08-01 00:00:00

  • The effects of exterior boundary conditions on a internally heated tumor tissue with a thermoporoelastic model.

    abstract::Modeling flow field in tumor regions interstitial space is of primary importance, because of the importance of advection in macromolecule drug delivery. Its deformation has also to be taken into account because of the forces caused by the fluid; if the tumor region is not isothermal, this deformation can be also stron...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.110122

    authors: Andreozzi A,Iasiello M,Netti PA

    更新日期:2020-12-02 00:00:00

  • Variables during swing associated with decreased impact peak and loading rate in running.

    abstract::When the foot impacts the ground in running, large forces and loading rates can arise that may contribute to the development of overuse injuries. Investigating which biomechanical factors contribute to these impact loads and loading rates in running could assist clinicians in developing strategies to reduce these load...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.10.026

    authors: Schmitz A,Pohl MB,Woods K,Noehren B

    更新日期:2014-01-03 00:00:00

  • Reproducibility analysis of upper limbs reachable workspace, and effects of acquisition protocol, sex and hand dominancy.

    abstract::None of the physical testing, nor the goniometers currently used to assess upper limb function have a high validity, sensitivity or reliability. The reachable workspace, i.e. the area covered by the farthest points a subject can reach by hand without moving his/her body, shows promise but has yet to be validated, part...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.12.010

    authors: Clément J,Raison M,Rouleau DM

    更新日期:2018-02-08 00:00:00

  • Influence of stent height upon stresses on the cusps of closed bioprosthetic valves.

    abstract::A finite element model of a bioprosthetic heart valve was developed to determine the influence of the stent height on leaflet stresses under various pressure loading conditions after valve closure. A nonlinear solution was used to obtain the stresses in the leaflets for stent heights of 14.6 mm, 19.0 mm and 22.0 mm re...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(86)90199-5

    authors: Hamid MS,Sabbah HN,Stein PD

    更新日期:1986-01-01 00:00:00

  • Changes in fascicle length from rest to maximal voluntary contraction affect the assessment of voluntary activation.

    abstract::The purpose of this study was to investigate the effect of the differences between the actual fascicle length during a voluntary contraction and the fascicle length at rest of the triceps surae muscle on the determination of the voluntary activation (VA) by using the interpolated twitch technique. Twelve participants ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.04.011

    authors: Arampatzis A,Mademli L,De Monte G,Walsh M

    更新日期:2007-01-01 00:00:00

  • Validation of shear wave elastography in skeletal muscle.

    abstract::Skeletal muscle is a very dynamic tissue, thus accurate quantification of skeletal muscle stiffness throughout its functional range is crucial to improve the physical functioning and independence following pathology. Shear wave elastography (SWE) is an ultrasound-based technique that characterizes tissue mechanical pr...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.07.033

    authors: Eby SF,Song P,Chen S,Chen Q,Greenleaf JF,An KN

    更新日期:2013-09-27 00:00:00

  • Application of singular spectrum analysis to the smoothing of raw kinematic signals.

    abstract::Motion capture systems currently used in biomechanical analysis introduce systematic measurement errors that appear in the form of noise in recorded displacement signals. The noise is unacceptably amplified when differentiating displacements to obtain velocities and accelerations. To avoid this phenomenon, it is neces...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2004.05.031

    authors: Alonso FJ,Castillo JM,Pintado P

    更新日期:2005-05-01 00:00:00

  • Application and validation of the lattice Boltzmann method for modelling flow-related clotting.

    abstract::The purpose of this paper is to present a simple clotting model, based on residence time and shear stress distribution, that can simulate the deposition over time of enzyme-activated milk in an in vitro system. Results for the model are compared with experiments exhibiting clot deposition in the region of a sharp-edge...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.01.026

    authors: Harrison SE,Smith SM,Bernsdorf J,Hose DR,Lawford PV

    更新日期:2007-01-01 00:00:00

  • A model of surfactant-induced surface tension effects on the parenchymal tethering of pulmonary airways.

    abstract::We developed a computational model of lung parenchyma, which is comprised of individual alveolar chamber models. Each alveolus is modeled by a truncated octahedron. Considering the force balance between the elastin and collagen fibers laying on the alveolar membrane and the pressures acting on the membrane, we compute...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2012.11.031

    authors: Fujioka H,Halpern D,Gaver DP 3rd

    更新日期:2013-01-18 00:00:00

  • Ex-vivo observation of calcification process in chick tibia slice: Augmented calcification along collagen fiber orientation in specimens subjected to static stretch.

    abstract::Bone formation through matrix synthesis and calcification in response to mechanical loading is an essential process of the maturation in immature animals, although how mechanical loading applied to the tissue increases the calcification and improves mechanical properties, and which directions the calcification progres...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.07.024

    authors: Maeda E,Ichikawa K,Murase K,Nagayama K,Matsumoto T

    更新日期:2018-09-10 00:00:00

  • Bone creep and short and long term subsidence after cemented stem total hip arthroplasty (THA).

    abstract::Stem-cement and cement-bone interfacial failures as well as cement fractures have been noted in cemented total hip arthroplasty (THA) as the cause of aseptic loosening. Attempts to reduce the risk of femoral component loosening include improving the stem-cement interface by various coatings, using a textured or porous...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2012.12.010

    authors: Norman TL,Shultz T,Noble G,Gruen TA,Blaha JD

    更新日期:2013-03-15 00:00:00

  • Sensitivity of temporomandibular joint force calculations to errors in muscle force measurements.

    abstract::A two-dimensional, five-muscle model was used to determine the degree of precision required for accurate calculation of temporomandibular joint force magnitude and direction. The sensitivity of the calculations to each variable were assessed by incrementing each variable through its presumed biological range and were ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(89)90206-6

    authors: Throckmorton GS

    更新日期:1989-01-01 00:00:00

  • Non-Newtonian blood flow in human right coronary arteries: transient simulations.

    abstract::This study looks at pulsatile blood flow through four different right coronary arteries, which have been reconstructed from biplane angiograms. A non-Newtonian blood model (the Generalised Power Law), as well as the usual Newtonian model of blood viscosity, is used to study the wall shear stress in each of these arter...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2005.01.034

    authors: Johnston BM,Johnston PR,Corney S,Kilpatrick D

    更新日期:2006-01-01 00:00:00

  • An in vitro model for the pathological degradation of articular cartilage in osteoarthritis.

    abstract::The objective of this study was to develop an in vitro cartilage degradation model that emulates the damage seen in early-stage osteoarthritis. To this end, cartilage explants were collagenase-treated to induce enzymatic degradation of collagen fibers and proteoglycans at the articular surface. To assess changes in me...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.11.050

    authors: Grenier S,Bhargava MM,Torzilli PA

    更新日期:2014-02-07 00:00:00

  • The use of a single sacral marker method to approximate the centre of mass trajectory during treadmill running.

    abstract::The three-dimensional trajectory of the body's centre of mass (COM) is useful to determine a number of biomechanical outcomes in running research. Previous studies have used the COM to calculate measures such as overstriding, vertical stiffness, and vertical oscillation. The COM is traditionally computed using the seg...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109886

    authors: Napier C,Jiang X,MacLean CL,Menon C,Hunt MA

    更新日期:2020-07-17 00:00:00

  • A wax barrier to simulate bone resorption for pre-clinical laboratory models of cemented total hip replacements.

    abstract::Pre-clinical tests are often performed to screen new implant designs, surgical techniques, and cement formulations. In this work, we developed a technique to simulate the cement-bone morphology found with postmortem retrieved cemented hip replacements. With this technique, a soy wax barrier is created along the endost...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.06.029

    authors: Cherukuri AR,Miller MA,Race A,Izant TH,Mann KA

    更新日期:2010-10-19 00:00:00

  • Understanding the fluid mechanics behind transverse wall shear stress.

    abstract::The patchy distribution of atherosclerosis within arteries is widely attributed to local variation in haemodynamic wall shear stress (WSS). A recently-introduced metric, the transverse wall shear stress (transWSS), which is the average over the cardiac cycle of WSS components perpendicular to the temporal mean WSS vec...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.11.035

    authors: Mohamied Y,Sherwin SJ,Weinberg PD

    更新日期:2017-01-04 00:00:00

  • Integrated geometric and mechanical analysis of an image-based lymphatic valve.

    abstract::Lymphatic valves facilitate the lymphatic system's role in maintaining fluid homeostasis. Malformed valves are found in several forms of primary lymphœdema, resulting in incurable swelling of the tissues and immune dysfunction. Their experimental study is complicated by their small size and operation in low pressure a...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.09.040

    authors: Watson DJ,Sazonov I,Zawieja DC,Moore JE Jr,van Loon R

    更新日期:2017-11-07 00:00:00

  • Modeling aqueous humor collection from the human eye.

    abstract::Glaucoma is a common cause of blindness. Studies of this disease can involve collection of aqueous humor (AH) fluid from eyes of patients undergoing surgery, which involves aspirating a small fluid volume from the anterior region of the eye through a fine-bore needle. Unfortunately, the composition of the AH is spatia...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.07.025

    authors: Kapnisis K,Doormaal MV,Ross Ethier C

    更新日期:2009-11-13 00:00:00

  • Relationships between femoral fracture loads for two load configurations.

    abstract::Studies of proximal femoral strength usually involve one of two types of loading conditions, loading similar to joint loading during single-limb stance or loading simulating impact from a fall. When interpreting the results of studies involving only one of these load configurations, the question arises as to their app...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(99)00202-x

    authors: Keyak JH

    更新日期:2000-04-01 00:00:00

  • An explicit expression for the moment in multibody systems.

    abstract::The equations of motion are formulated for a set of interacting rigid bodies. An explicit formulation could be derived for the total moment of the forces on such a system. This is applied to (1) the intersegmental moment in a multisegment rigid-body model, and (2) the interpretation of the 'centre of pressure' as defi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(92)90076-d

    authors: Hof AL

    更新日期:1992-10-01 00:00:00

  • An analytical study on the thermal effects of cryosurgery on selective cell destruction.

    abstract::The aim of cryosurgery is to kill cells within a closely defined region maintained at a predetermined low temperature. To effectively kill cells, it is important to be able to predict and control the cooling rate over some critical range of temperatures and freezing states in order to regulate the spatial extent of in...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2005.11.005

    authors: Chua KJ,Chou SK,Ho JC

    更新日期:2007-01-01 00:00:00

  • Optimization-based differential kinematic modeling exhibits a velocity-control strategy for dynamic posture determination in seated reaching movements.

    abstract::We proposed a velocity control strategy for dynamic posture determination that underlay an optimization-based differential inverse kinematics (ODIK) approach for modeling three-dimensional (3-D) seated reaching movements. In this modeling approach, a four-segment seven-DOF linkage is employed to represent the torso an...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(98)00117-1

    authors: Zhang X,Kuo AD,Chaffin DB

    更新日期:1998-11-01 00:00:00

  • Tribology studies of the natural knee using an animal model in a new whole joint natural knee simulator.

    abstract::The successful development of early-stage cartilage and meniscus repair interventions in the knee requires biomechanical and biotribological understanding of the design of the therapeutic interventions and their tribological function in the natural joint. The aim of this study was to develop and validate a porcine kne...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.07.043

    authors: Liu A,Jennings LM,Ingham E,Fisher J

    更新日期:2015-09-18 00:00:00

  • Compressive creep behavior of bovine trabecular bone.

    abstract::There are almost no published data that describe the creep behavior of trabecular bone (at the specimen level), even though the creep behavior of cortical bone has been well documented. In an effort to characterize the creep behavior of trabecular bone and to compare it with that of cortical bone, we performed uniaxia...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章,评审

    doi:10.1016/0021-9290(94)90006-x

    authors: Bowman SM,Keaveny TM,Gibson LJ,Hayes WC,McMahon TA

    更新日期:1994-03-01 00:00:00

  • Finite element investigation of the loading rate effect on the spinal load-sharing changes under impact conditions.

    abstract::Sudden deceleration and frontal/rear impact configurations involve rapid movements that can cause spinal injuries. This study aimed to investigate the rotation rate effect on the L2-L3 motion segment load-sharing and to identify which spinal structure is at risk of failure and at what rotation velocity the failure may...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.03.036

    authors: El-Rich M,Arnoux PJ,Wagnac E,Brunet C,Aubin CE

    更新日期:2009-06-19 00:00:00

  • Synthesis and characterisation of core-shell structures for orthopaedic surgery.

    abstract::This paperwork deals with the obtaining and characterisation of new acrylic cements for bone surgery. The final mixture of cement contains derivatives of methacryloyloxyethyl phosphate, methacrylic acid or 2-acrylamido-2-methyl-1-propane sulphonic acid. The idea of using these monomers is sustained by their ability to...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.05.002

    authors: Rusen E,Zaharia C,Zecheru T,Mărculescu B,Filmon R,Chappard D,Bădulescu R,Cincu C

    更新日期:2007-01-01 00:00:00

  • The effect of isokinetic dynamometer deceleration phase on maximum ankle joint range of motion and plantar flexor mechanical properties tested at different angular velocities.

    abstract::During range of motion (max-ROM) tests performed on an isokinetic dynamometer, the mechanical delay between the button press (by the participant to signal their max-ROM) and the stopping of joint rotation resulting from system inertia induces errors in both max-ROM and maximum passive joint moment. The present study a...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.05.036

    authors: Pinto MD,Wilson CJ,Kay AD,Cochrane J,Blazevich AJ

    更新日期:2019-07-19 00:00:00

  • Compressive and shear hip joint contact forces are affected by pediatric obesity during walking.

    abstract::Obese children exhibit altered gait mechanics compared to healthy-weight children and have an increased prevalence of hip pain and pathology. This study sought to determine the relationships between body mass and compressive and shear hip joint contact forces during walking. Kinematic and kinetic data were collected d...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.03.033

    authors: Lerner ZF,Browning RC

    更新日期:2016-06-14 00:00:00