The influence of the instabilities in modelling arteriovenous junction haemodynamics.

Abstract:

:The arteriovenous junction is characterised by high flow rates, large pressure difference and typically a palpable thrill or audible bruit, associated with turbulent flow. However, the arteriovenous junction is frequently studied with the assumption of streamline flow. This assumption is based on the Reynolds number calculation, although other factors can contribute to turbulent generation. In this study, the presence of instabilities is examined and the influencing factors discussed. This was performed using a pseudo-realistic geometry with adapted graft angles, vein diameter, outflow split ratio and graft inlet velocity values. Correlation was performed between steady and unsteady averaged simulation cases with correlation performance ranked. Overall the arteriovenous junction is capable of possessing highly disturbed flows, in which strict modelling requirements are necessary to capture such instabilities and avoid erroneous conclusions. Vein diameter and flow split ratio contribute to turbulent generation, thus Reynolds number cannot be used as a sole turbulent criterion in the arteriovenous junction.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Broderick SP,Houston JG,Walsh MT

doi

10.1016/j.jbiomech.2015.07.038

subject

Has Abstract

pub_date

2015-10-15 00:00:00

pages

3591-8

issue

13

eissn

0021-9290

issn

1873-2380

pii

S0021-9290(15)00432-7

journal_volume

48

pub_type

杂志文章
  • Influence of microcalcifications on vulnerable plaque mechanics using FSI modeling.

    abstract::Sudden heart attacks remain one of the primary causes of premature death in the developed world. Asymptomatic vulnerable plaques that rupture are believed to prompt such fatal heart attacks and strokes. The role of microcalcifications in the vulnerable plaque rupture mechanics is still debated. Recent studies suggest ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.11.029

    authors: Bluestein D,Alemu Y,Avrahami I,Gharib M,Dumont K,Ricotta JJ,Einav S

    更新日期:2008-01-01 00:00:00

  • Do quadrupeds require a change in trunk posture to walk backward?

    abstract::Previous studies on cats walking backward have indicated that they adopt a presumably adaptive posture characterized by extreme dorsiflexion of the lumbar spine. Because humans do not show any marked postural changes during backward walking, we questioned whether the posture exhibited by cats during backward walking w...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(00)00071-3

    authors: Vilensky JA,Cook JA

    更新日期:2000-08-01 00:00:00

  • The effect of shortening history on isometric and dynamic muscle function.

    abstract::Despite numerous reports on isometric force depression, few reports have quantified force depression during active muscle shortening (dynamic force depression). The purpose of this investigation was to determine the influence of shortening history on isometric force following active shortening, force during isokinetic...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.10.041

    authors: McDaniel J,Elmer SJ,Martin JC

    更新日期:2010-03-03 00:00:00

  • Age-related distensibility and histology of the ascending aorta in elderly patients with acute aortic dissection.

    abstract::Degradation and fragmentation of elastic fibers in the media dilate the aortic wall excessively in patients with acute Stanford type A aortic dissection (AD). Such dilatation occurs not via aortic stiffening, which is diagnosed using imaging under physiological loading, but due to the abovementioned intrinsic changes ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.06.025

    authors: Yamada H,Sakata N,Wada H,Tashiro T,Tayama E

    更新日期:2015-09-18 00:00:00

  • Velocity profiles in the wake of two prosthetic heart valves using a new cardiovascular simulator.

    abstract::In this paper we present a study of the post valvular flow field on a new cardiovascular simulator including an elastic model of the aortic arch. Transverse and vertical two-dimensional velocity measurements are performed with an ultrasonic velocimeter. Two prosthetic heart valves are tested in the aortic position. Th...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(85)90054-5

    authors: Farahifar D,Cassot F,Bodard H,Pelissier R

    更新日期:1985-01-01 00:00:00

  • Quantification of red blood cell deformation at high-hematocrit blood flow in microvessels.

    abstract::The deformation of red blood cells in microvessels was investigated numerically for various vessel diameters, hematocrits, and shear rates. We simulated blood flow in circular channels with diameters ranging from 9 to 50 μm, hematocrits from 20% to 45%, and shear rates from 20 to 150 s(-1) using a particle-based model...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2012.08.026

    authors: Alizadehrad D,Imai Y,Nakaaki K,Ishikawa T,Yamaguchi T

    更新日期:2012-10-11 00:00:00

  • Moment-rotation behavior of intervertebral joints in flexion-extension, lateral bending, and axial rotation at all levels of the human spine: A structured review and meta-regression analysis.

    abstract::Spinal intervertebral joints are complex structures allowing motion in multiple directions, and many experimental studies have reported moment-rotation response. However, experimental methods, reporting of results, and levels of the spine tested vary widely, and a comprehensive assessment of moment-rotation response a...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章,meta分析,评审

    doi:10.1016/j.jbiomech.2019.109579

    authors: Zhang C,Mannen EM,Sis HL,Cadel ES,Wong BM,Wang W,Cheng B,Friis EA,Anderson DE

    更新日期:2020-02-13 00:00:00

  • Evaluation of left ventricular function based on simulated systolic flow dynamics computed from regional wall motion.

    abstract::Left ventricular (LV) chamber flow is undoubtedly influenced by the time-dependent regional motion of the LV wall. In an attempt to obtain diagnostic parameters based on LV chamber flow, we computed the LV chamber, two-dimensional systolic velocity and pressure distribution for two right anterior oblique (RAO) ventric...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(94)90201-1

    authors: Schoephoerster RT,Silva CL,Ray G

    更新日期:1994-02-01 00:00:00

  • Reconstruction of proximal humeral fractures without screws using a reinforced bone substitute.

    abstract::Multi-fragment fractures are still a challenge: current clinical practice relies on plates and screws. Treatment of fractures of the proximal humerus has the intra-operative risk of articular damage when inserting multiple screws. Distal-varus collapse of the head is a frequent complication in osteoporotic patients. T...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.110138

    authors: Cristofolini L,Ruspi ML,Marras D,Cavallo M,Guerra E

    更新日期:2021-01-22 00:00:00

  • Modelling the mechanical effect of muscles with large attachment sites: application to the shoulder mechanism.

    abstract::A general theory is described for deriving the mechanical effect of muscles with large attachment sites. In a cadaver experiment the complete attachment sites and bundle distribution of 16 muscles of the shoulder mechanism were recorded. These data were used to calculate the mechanical effect, i.e. the resulting force...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(91)90007-a

    authors: Van der Helm FC,Veenbaas R

    更新日期:1991-01-01 00:00:00

  • Microcrack growth parameters for compact bone deduced from stiffness variations.

    abstract::This paper shows how information on the fatigue behaviour of microcracks can be obtained by the analysis of stiffness changes measured during cyclic loading. Relationships between crack length, growth rate and cyclic stress intensity were deduced, and compared with previous empirical equations. Results show that the c...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(98)00050-5

    authors: Taylor D

    更新日期:1998-07-01 00:00:00

  • Falls resulting from a laboratory-induced slip occur at a higher rate among individuals who are obese.

    abstract::Falls due to slipping are a serious concern, with slipping estimated to cause 40-50% of all fall-related injuries. Epidemiological data indicates that older and obese adults experience more falls than young, non-obese individuals. An increasingly heavier and older U.S. population and workforce may be exacerbating the ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.01.018

    authors: Allin LJ,Wu X,Nussbaum MA,Madigan ML

    更新日期:2016-03-21 00:00:00

  • Cross-sectional structural parameters from densitometry.

    abstract::Bone densitometry has previously been used to obtain cross-sectional properties of bone from a single X-ray projection across the bone width. Using three unique projections, we have extended the method to obtain the principal area moments of inertia and orientations of the principal axes at each scan cross-section alo...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(01)00220-2

    authors: Cleek TM,Whalen RT

    更新日期:2002-04-01 00:00:00

  • The effect of sterilization on the dynamic mechanical properties of paired rabbit cortical bone.

    abstract::The optimal sterilization method for load bearing allografts remains a clinical concern. Recently, supercritical carbon dioxide (SCCO2) treatments have been shown to be capable of terminally sterilizing a range of bacteria and viruses, while preserving the static mechanical properties of cortical bone. This study eval...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.04.006

    authors: Russell N,Rives A,Bertollo N,Pelletier MH,Walsh WR

    更新日期:2013-06-21 00:00:00

  • The vesico-urethral pressuregram analysis of urethral function under stress.

    abstract::About one-third of older multiparous women are prone to stress urinary incontinence (SUI): unwanted urine loss during activities which suddenly raise intra-abdominal pressure. In this paper we describe and test a method for visualizing and analyzing the function of the urinary continence control system (CCS) under str...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(97)81291-2

    authors: Kim KJ,Ashton-Miller JA,Strohbehn K,DeLancey JO,Schultz AB

    更新日期:1997-01-01 00:00:00

  • The human ankle during walking: implications for design of biomimetic ankle prostheses.

    abstract::The non-disabled human ankle joint was examined during walking in an attempt to determine overall system characteristics for use in the design of ankle prostheses. The hypothesis of the study was that the quasi-stiffness of the ankle changes when walking at different walking speeds. The hypothesis was examined using s...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2004.01.017

    authors: Hansen AH,Childress DS,Miff SC,Gard SA,Mesplay KP

    更新日期:2004-10-01 00:00:00

  • Canine intersegmental hip joint forces and moments before and after cemented total hip replacement.

    abstract::Intersegmental forces and moments (i.e. resultant free body forces and moments computed at the joint centers) were studied in canine hindlimbs before and after cemented total hip replacement (THR). Five large, adult, mixed-breed dogs were selected. Their gait was recorded (while leash-walked) before surgery using high...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(91)90028-l

    authors: Dogan S,Manley PA,Vanderby R Jr,Kohles SS,Hartman LM,McBeath AA

    更新日期:1991-01-01 00:00:00

  • In vivo knee joint loading and kinematics before and after ACL transection in an animal model.

    abstract::Osteoarthritis (OA) is typically diagnosed in humans in its final stage when joint movement becomes painful. Clinical information about the onset and the mechanisms triggering the degenerative responses are virtually non-existent. However, research on animal models of experimental OA shows that joint adaptations assoc...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(97)00119-x

    authors: Hasler EM,Herzog W,Leonard TR,Stano A,Nguyen H

    更新日期:1998-03-01 00:00:00

  • Volumetric locking free 3D finite element for modelling of anisotropic visco-hyperelastic behaviour of anterior cruciate ligament.

    abstract::Solids such as polymers, soft biological tissues display visco-hyperelastic, isochoric and finite deformation behaviour. The incompressibility constraint imposed severe restriction on the displacement field results in volumetric locking. Many techniques have been developed to address the issue such as reduced integrat...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.03.016

    authors: Bijalwan A,Patel BP,Marieswaran M,Kalyanasundaram D

    更新日期:2018-05-17 00:00:00

  • Ligamentous versus physeal failure in murine medial collateral ligament biomechanical testing.

    abstract::This study examines the age at which a femoral physeal failure ceased to occur in a mouse model of medial collateral ligament (MCL) testing. Biomechanical testing of the MCL with load to failure can result in physeal failure rather than MCL failure in skeletally immature animals. Failure mode depended significantly on...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2004.05.014

    authors: El-Zawawy HB,Silva MJ,Sandell LJ,Wright RW

    更新日期:2005-04-01 00:00:00

  • Using the loading response peak for defining gait cycle timing: A novel solution for the double-belt problem.

    abstract::Split-belt treadmills (SBTM) contain force plates under each belt that measure ground reaction force (GRF). Initial contact (IC) detection for each gait cycle obtained from the GRF is used for calculating temporal gait parameters (e.g., gait variability, step time, stride time). Occasionally, the participant steps wit...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109963

    authors: Ben-Gal O,Benady A,Zadik S,Doniger GM,Schnaider Beeri M,Plotnik M

    更新日期:2020-09-18 00:00:00

  • Steady flow in a model of the human carotid bifurcation. Part I--flow visualization.

    abstract::The geometry of a typical adult human carotid bifurcation, complete with the sinus, was established from a study of a large number of angiograms. A rigid model was constructed from glass and investigations were performed under steady flow conditions using flow visualization techniques over a range of upstream Reynolds...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(82)90057-4

    authors: Bharadvaj BK,Mabon RF,Giddens DP

    更新日期:1982-01-01 00:00:00

  • Adhesive strength of atherosclerotic plaque in a mouse model depends on local collagen content and elastin fragmentation.

    abstract::Atherosclerotic plaque rupture is a major cause of myocardial infarction and ischemic stroke. The adhesive strength of the bond between a plaque and the vascular wall, measured as local energy release rate, G, is used for quantitative plaque stability estimation. We tested the hypothesis that adhesive strength varies ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2012.11.041

    authors: Wang Y,Johnson JA,Fulp A,Sutton MA,Lessner SM

    更新日期:2013-02-22 00:00:00

  • Ventilation inhomogeneity: alveolar mechanics and gas distribution.

    abstract::The effects of regional lung differences in alveolar mechanics on the transpulmonary pressure-volume (Ptp-V) relationship and the single-breath washout (SBW) of nitrogen were investigated by mathematical modeling and postmorten human lung experiments. Regional nonuniformity in alveolar collapse and re-opening were ass...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(83)90100-8

    authors: Salmon RB,Saidel GM,Primiano FP Jr,Niewoehner DE,Chester EH

    更新日期:1983-01-01 00:00:00

  • Estimating severity of sideways fall using a generic multi linear regression model based on kinematic input variables.

    abstract::Many research groups have studied fall impact mechanics to understand how fall severity can be reduced to prevent hip fractures. Yet, direct impact force measurements with force plates are restricted to a very limited repertoire of experimental falls. The purpose of this study was to develop a generic model for estima...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.01.033

    authors: van der Zijden AM,Groen BE,Tanck E,Nienhuis B,Verdonschot N,Weerdesteyn V

    更新日期:2017-03-21 00:00:00

  • Influence of muscle anatomical cross-sectional area on the moment arm length of the triceps brachii muscle at the elbow joint.

    abstract::The purpose of this study was to test the hypothesis that the musculotendon moment arm length is affected by the muscle anatomical cross-sectional area. The moment arm length of the triceps brachii (TB) muscle at 30°, 50°, 70°, 90°, 110° elbow flexion positions was measured in sagittal magnetic resonance images (MRI) ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.06.013

    authors: Sugisaki N,Wakahara T,Miyamoto N,Murata K,Kanehisa H,Kawakami Y,Fukunaga T

    更新日期:2010-10-19 00:00:00

  • Validation of the Leap Motion Controller using markered motion capture technology.

    abstract::The Leap Motion Controller (LMC) is a low-cost, markerless motion capture device that tracks hand, wrist and forearm position. Integration of this technology into healthcare applications has begun to occur rapidly, making validation of the LMC׳s data output an important research goal. Here, we perform a detailed evalu...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.04.006

    authors: Smeragliuolo AH,Hill NJ,Disla L,Putrino D

    更新日期:2016-06-14 00:00:00

  • A study of the viability of obtaining a generic animation of the foot while walking for the virtual testing of footwear using dorsal pressures.

    abstract::Establishing the appropriate pressure exerted by the shoe upper over the foot surface is fundamental for the design of specific footwear, although measuring the dorsal pressures can also provide important additional information. In previous works, a virtual simulator to perform studies of comfort and functionality in ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.06.054

    authors: Rupérez MJ,Alemany S,Monserrat C,Olaso J,Alcañíz M,González JC

    更新日期:2009-09-18 00:00:00

  • Loads on an internal spinal fixation device during sitting.

    abstract::Sitting is often assumed to involve high loads on the spine as well as on implants for stabilising the spine. Loads on internal spinal fixation devices were therefore measured in ten patients sitting on several types of seats, including a stool, a stool with a padded wedge, a chair, a physiotherapy ball, a knee-stool,...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(01)00073-2

    authors: Rohlmann A,Arntz U,Graichen F,Bergmann G

    更新日期:2001-08-01 00:00:00

  • On the permanent hip-stabilizing effect of atmospheric pressure.

    abstract::Hip joint dislocations related to total hip arthroplasty (THA) are a common complication especially in the early postoperative course. The surgical approach, the alignment of the prosthetic components, the range of motion and the muscle tone are known factors influencing the risk of dislocation. A further factor that ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.05.013

    authors: Prietzel T,Hammer N,Schleifenbaum S,Kaßebaum E,Farag M,von Salis-Soglio G

    更新日期:2014-08-22 00:00:00