Relationship between shear modulus and passive tension of the posterior shoulder capsule using ultrasound shear wave elastography: A cadaveric study.

Abstract:

:Although shear wave elastography (SWE) has been used to indirectly measure passive tension in muscle tissues, it is unknown whether SWE can adequately evaluate passive tension in capsule tissues. This study investigated the relationship between the shear modulus and passive tension in the posterior shoulder capsule using SWE. Ten posterior middle and ten posterior inferior shoulder capsules were dissected from ten fresh-frozen cadavers; humeral head-capsule-glenoid specimens were created from each capsule. The humeral head and glenoid were immobilized with clamps in a custom-built device. Loads (0-400 g, in 25-g increments) were applied to each capsule via a pulley system; elasticity was simultaneously measured using SWE. The elasticity-load relationship of each tested capsule was analyzed by fitting a least-squares regression line to the data. Elasticity change due to creep or hysteresis effects was evaluated by comparing the elastic modulus for a 100-g load during and after the stepwise application of the loads. The observed relationship between the shear modulus and passive capsule tension was highly linear for all twenty tested capsules (p < 0.01). The mean coefficient of determination was 0.882 ± 0.075 and 0.901 ± 0.050 for the posterior middle and posterior inferior capsules, respectively. There was no difference in the shear modulus between the two 100-g load assessments for both the posterior middle (p = 0.205) and posterior inferior capsules (p = 0.161). Thus, SWE is a valid and useful method for indirectly evaluating the change in the passive tension under loading in specific posterior shoulder capsule.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Iida N,Taniguchi K,Watanabe K,Miyamoto H,Taniguchi T,Fujimiya M,Katayose M

doi

10.1016/j.jbiomech.2019.109498

subject

Has Abstract

pub_date

2020-01-23 00:00:00

pages

109498

eissn

0021-9290

issn

1873-2380

pii

S0021-9290(19)30748-1

journal_volume

99

pub_type

杂志文章
  • Vertebroplasty reduces progressive ׳creep' deformity of fractured vertebrae.

    abstract::Elderly vertebrae frequently develop an "anterior wedge" deformity as a result of fracture and creep mechanisms. Injecting cement into a damaged vertebral body (vertebroplasty) is known to help restore its shape and stiffness. We now hypothesise that vertebroplasty is also effective in reducing subsequent creep deform...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.09.006

    authors: Luo J,Pollintine P,Annesley-Williams DJ,Dolan P,Adams MA

    更新日期:2016-04-11 00:00:00

  • Influence of muscle anatomical cross-sectional area on the moment arm length of the triceps brachii muscle at the elbow joint.

    abstract::The purpose of this study was to test the hypothesis that the musculotendon moment arm length is affected by the muscle anatomical cross-sectional area. The moment arm length of the triceps brachii (TB) muscle at 30°, 50°, 70°, 90°, 110° elbow flexion positions was measured in sagittal magnetic resonance images (MRI) ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.06.013

    authors: Sugisaki N,Wakahara T,Miyamoto N,Murata K,Kanehisa H,Kawakami Y,Fukunaga T

    更新日期:2010-10-19 00:00:00

  • Finite element investigation of the loading rate effect on the spinal load-sharing changes under impact conditions.

    abstract::Sudden deceleration and frontal/rear impact configurations involve rapid movements that can cause spinal injuries. This study aimed to investigate the rotation rate effect on the L2-L3 motion segment load-sharing and to identify which spinal structure is at risk of failure and at what rotation velocity the failure may...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.03.036

    authors: El-Rich M,Arnoux PJ,Wagnac E,Brunet C,Aubin CE

    更新日期:2009-06-19 00:00:00

  • NLT and extrapolated DLT:3-D cinematography alternatives for enlarging the volume of calibration.

    abstract::This study investigated the accuracy of the direct linear transformation (DLT) and non-linear transformation (NLT) methods of 3-D cinematography/videography. A comparison of standard DLT, extrapolated DLT, and NLT calibrations showed the standard (non-extrapolated) DLT to be the most accurate, especially when a large ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(95)00034-f

    authors: Hinrichs RN,McLean SP

    更新日期:1995-10-01 00:00:00

  • The use of a single inertial sensor to estimate 3-dimensional ground reaction force during accelerative running tasks.

    abstract::The purpose of this investigation was to determine the feasibility of using a single inertial measurement unit (IMU) placed on the sacrum to estimate 3-dimensional ground reaction force (F) during linear acceleration and change of direction tasks. Force plate measurements of F and estimates from the proposed IMU metho...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.07.035

    authors: Gurchiek RD,McGinnis RS,Needle AR,McBride JM,van Werkhoven H

    更新日期:2017-08-16 00:00:00

  • A novel approach to estimate trabecular bone anisotropy using a database approach.

    abstract::Continuum finite element (FE) models of bones have become a standard pre-clinical tool to estimate bone strength. These models are usually based on clinical CT scans and material properties assigned are chosen as isotropic based only on the density distribution. It has been shown, however, that trabecular bone elastic...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.07.042

    authors: Hazrati Marangalou J,Ito K,Cataldi M,Taddei F,van Rietbergen B

    更新日期:2013-09-27 00:00:00

  • On the assumption of steadiness of nasal cavity flow.

    abstract::The unsteady flow through a model of the human nasal cavity is analyzed at a Strouhal number of Sr=0.791 for the complete respiration cycle. A comparison of the essential flow structures in the model geometry and a real nasal cavity shows the relevance of the model data. The analysis of the steady and unsteady solutio...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.12.008

    authors: Hörschler I,Schröder W,Meinke M

    更新日期:2010-04-19 00:00:00

  • Translational constraint influences dynamic spinal canal occlusion of the thoracic spine: an in vitro experimental study.

    abstract::Mechanical constraints to spine motion can arise in a variety of real-world situations such as when shoulder belts prevent anterior translation of the thorax during automotive collisions. The effect of such constraint on spinal column-spinal cord interaction during injury remains unknown. The purpose of the present st...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.06.030

    authors: Zhu Q,Lane C,Ching RP,Gordon JD,Fisher CG,Dvorak MF,Cripton PA,Oxland TR

    更新日期:2008-01-01 00:00:00

  • Impact-induced osteochondral fracture in the tibial plateau.

    abstract::In this study, human tibia plateaus with the meniscus removed were impacted on various regions of the plateau surface via a drop test using a 5mm indenter. Osteochondral blocks containing the failure site were then extracted, chemically fixed, dehydrated, gold-particle coated, and sent for X-ray micro-CT imaging to ob...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.01.033

    authors: Thambyah A,Shim VP,Chong LM,Lee VS

    更新日期:2008-01-01 00:00:00

  • Single-subject analysis reveals variation in knee mechanics during step landing.

    abstract:PURPOSE:Evidence concerning the alteration of knee function during landing suffers from a lack of consensus. This uncertainty can be attributed to methodological flaws, particularly in relation to the statistical analysis of variable human movement data. The aim of this study was to compare single-subject and group ana...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.jbiomech.2012.05.046

    authors: Scholes CJ,McDonald MD,Parker AW

    更新日期:2012-08-09 00:00:00

  • Sagittal range of motion of the thoracic spine using inertial tracking device and effect of measurement errors on model predictions.

    abstract::Range of motion (ROM) of the thoracic spine has implications in patient discrimination for diagnostic purposes and in biomechanical models for predictions of spinal loads. Few previous studies have reported quite different thoracic ROMs. Total (T1-T12), lower (T5-T12) and upper (T1-T5) thoracic, lumbar (T12-S1), pelvi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.09.003

    authors: Hajibozorgi M,Arjmand N

    更新日期:2016-04-11 00:00:00

  • Effects of aging on hip abductor-adductor neuromuscular and mechanical performance during the weight transfer phase of lateral protective stepping.

    abstract::Aging brings about challenges in the ability to recover balance through protective stepping, especially in the lateral direction. Previous work has suggested that lateral protective stepping during weight transfer may be affected by impaired muscle composition and performance of the hip abductors (AB) in older adults....

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.10.040

    authors: Inacio M,Creath R,Rogers MW

    更新日期:2019-01-03 00:00:00

  • Differences in 3D vs. 2D analysis in lumbar spinal fusion simulations.

    abstract::Lumbar interbody fusion is currently the gold standard in treating patients with disc degeneration or segmental instability. Despite it having been used for several decades, the non-union rate remains high. A failed fusion is frequently attributed to an inadequate mechanical environment after instrumentation. Finite e...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.03.009

    authors: Hsu HW,Bashkuev M,Pumberger M,Schmidt H

    更新日期:2018-04-27 00:00:00

  • A musculoskeletal model of the human lower extremity: the effect of muscle, tendon, and moment arm on the moment-angle relationship of musculotendon actuators at the hip, knee, and ankle.

    abstract::We have developed a musculoskeletal model of the human lower extremity for computer simulation studies of musculotendon function and muscle coordination during movement. This model incorporates the salient features of muscle and tendon, specifies the musculoskeletal geometry and musculotendon parameters of 18 musculot...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(90)90349-8

    authors: Hoy MG,Zajac FE,Gordon ME

    更新日期:1990-01-01 00:00:00

  • Does stretching velocity affect residual force enhancement?

    abstract::It is thought that the magnitude of residual force enhancement (RFE) is not affected by stretch velocity. However, the range of stretch velocities studied in previous investigations has been limited to slow and moderate velocities. High velocities of muscle stretching are associated with a loss of force and incomplete...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.04.033

    authors: Fukutani A,Leonard T,Herzog W

    更新日期:2019-05-24 00:00:00

  • Failure mechanism of the all-polyethylene glenoid implant.

    abstract::Fixation failure of glenoid components is the main cause of unsuccessful total shoulder arthroplasties. The characteristics of these failures are still not well understood, hence, attempts at improving the implant fixation are somewhat blind and the failure rate remains high. This lack of understanding is largely due ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.10.019

    authors: Sarah J,Sanjay G,Sanjay S,Carolyn A,Emery R,Andrew A,Ulrich H

    更新日期:2010-03-03 00:00:00

  • A reduction of the saddle vertical force triggers the sit-stand transition in cycling.

    abstract::The purpose of the study was to establish the link between the saddle vertical force and its determinants in order to establish the strategies that could trigger the sit-stand transition. We hypothesized that the minimum saddle vertical force would be a critical parameter influencing the sit-stand transition during cy...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.07.035

    authors: Costes A,Turpin NA,Villeger D,Moretto P,Watier B

    更新日期:2015-09-18 00:00:00

  • Pulsatile flow of non-Newtonian fluids through arterial stenoses.

    abstract::The problem of blood flow through stenoses is solved using the incompressible generalized Newtonian model. The Herschel-Bulkley, Bingham and power-law fluids are incorporated. The geometry corresponds to a rigid circular tube with a partial occlusion. Calculations are performed by a Galerkin finite-element method. For...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(95)00151-4

    authors: Tu C,Deville M

    更新日期:1996-07-01 00:00:00

  • A new system for analyzing swim fin propulsion based on human kinematic data.

    abstract::The use of swim fins has become popular in various water sport activities. While numerous models of swim fin with various innovative shapes have been subjectively designed, the exact influence of the fin characteristics on swimming performance is still much debated, and remains difficult to quantify. To date, the most...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.03.031

    authors: Nicolas G,Bideau B,Bideau N,Colobert B,Le Guerroue G,Delamarche P

    更新日期:2010-07-20 00:00:00

  • Knee joint biomechanics of patients with unilateral total knee arthroplasty during stationary cycling.

    abstract::Stationary cycling is typically recommended following total knee arthroplasty (TKA) operations. However, knee joint biomechanics during cycling remains mostly unknown for TKA patients. Biomechanical differences between the replaced and non-replaced limb may inform applications of cycling in TKA rehabilitation. The pur...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.110111

    authors: Hummer E,Thorsen T,Weinhandl JT,Cates H,Zhang S

    更新日期:2021-01-22 00:00:00

  • Biomechanical comparison of the human cadaveric pelvis with a fourth generation composite model.

    abstract::The use of cadavers for orthopaedic biomechanics research is well established, but presents difficulties to researchers in terms of cost, biosafety, availability, and ease of use. High fidelity composite models of human bone have been developed for use in biomechanical studies. While several studies have utilized comp...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.12.050

    authors: Girardi BL,Attia T,Backstein D,Safir O,Willett TL,Kuzyk PR

    更新日期:2016-02-29 00:00:00

  • Fracture analysis for biological materials with an expanded cohesive zone model.

    abstract::In this study, a theoretical framework for simulation of fracture of bone and bone-like materials is provided. An expanded cohesive zone model with thermodynamically consistent framework has been proposed and used to investigate the crack growth resistance of bone and bone-like materials. The reversible elastic deform...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.04.054

    authors: An B,Zhao X,Arola D,Zhang D

    更新日期:2014-07-18 00:00:00

  • In-vivo 6 degrees-of-freedom kinematics of metal-on-polyethylene total hip arthroplasty during gait.

    abstract::Knowledge of accurate in-vivo 6 degree-of-freedom (6-DOF) kinematics of total hip arthroplasty (THA) during daily activities is critical for improvement of longevity of the components. Previous studies assessed in-vivo THA kinematics using skin marker-based motion analysis. However, skin markers are prone to move with...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.03.012

    authors: Tsai TY,Li JS,Wang S,Scarborough D,Kwon YM

    更新日期:2014-05-07 00:00:00

  • Measurement of in vivo anterior cruciate ligament strain during dynamic jump landing.

    abstract::Despite recent attention in the literature, anterior cruciate ligament (ACL) injury mechanisms are controversial and incidence rates remain high. One explanation is limited data on in vivo ACL strain during high-risk, dynamic movements. The objective of this study was to quantify ACL strain during jump landing. Marker...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.10.028

    authors: Taylor KA,Terry ME,Utturkar GM,Spritzer CE,Queen RM,Irribarra LA,Garrett WE,DeFrate LE

    更新日期:2011-02-03 00:00:00

  • Study on modelling of PMMA bone cement polymerisation.

    abstract::This contribution is concerned with the modelling of PMMA-based bone cement polymerisation process and the associated heat effect. While existing models use description in terms of the so-called polymerisation fraction to fit the experimental data, the new model is constructed in such a way as to mimic the chemical pr...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2004.06.021

    authors: Stańczyk M

    更新日期:2005-07-01 00:00:00

  • Evaluation of the superficial characteristics of articular cartilage using evanescent waves in the friction tests with intermittent sliding and loading.

    abstract::Articular cartilage plays an important role in the lubrication of synovial joints because of its peculiar characteristics. In this work, the frictional and superficial characteristics of articular cartilage were evaluated simultaneously during intermittent sliding and loading. The apparatus used for the analysis of th...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2005.06.015

    authors: Naka MH,Hattori K,Ikeuchi K

    更新日期:2006-01-01 00:00:00

  • A stereophotogrammetric method for determining in situ contact areas in diarthrodial joints, and a comparison with other methods.

    abstract::Determination of contact areas in diarthrodial joints is necessary for understanding the state of stress within the articular cartilage layers and the supporting bony structures. The present study describes the use of a stereophotogrammetry (SPG) system [Huiskes et al., J. Biomechanics 18, 559-570 (1985) and Ateshian ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(94)90038-8

    authors: Ateshian GA,Kwak SD,Soslowsky LJ,Mow VC

    更新日期:1994-01-01 00:00:00

  • A kinematic algorithm to identify gait events during running at different speeds and with different footstrike types.

    abstract::Although a number of algorithms exist for estimating ground contact events (GCEs) from kinematic data during running, they are typically only applicable to heelstrike running, or have only been evaluated at a single running speed. The purpose of this study was to investigate the accuracy of four kinematics-based algor...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.10.013

    authors: Handsaker JC,Forrester SE,Folland JP,Black MI,Allen SJ

    更新日期:2016-12-08 00:00:00

  • Mechanical characterization of stomach tissue under uniaxial tensile action.

    abstract::In this article, the tensile properties of gastric wall were investigated by using biomechanical test and theoretical analysis. The samples of porcine stomach strips from smaller and greater curvature of the stomach were cut in longitudinal and circumferential direction, respectively. The loading-unloading, stress rel...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.12.048

    authors: Jia ZG,Li W,Zhou ZR

    更新日期:2015-02-26 00:00:00

  • Volume effects on fatigue life of equine cortical bone.

    abstract::Materials, including bone, often fail due to loading in the presence of critical flaws. The relative amount, location, and interaction of these flaws within a stressed volume of material play a role in determining the failure properties of the structure. As materials are generally imperfect, larger volumes of material...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.05.025

    authors: Bigley RF,Gibeling JC,Stover SM,Hazelwood SJ,Fyhrie DP,Martin RB

    更新日期:2007-01-01 00:00:00