A novel approach to predicting human ingress motion using an artificial neural network.

Abstract:

:Due to the increased availability of digital human models, the need for knowing human movement is important in product design process. If the human motion is derived rapidly as design parameters change, a developer could determine the optimal parameters. For example, the optimal design of the door panel of an automobile can be obtained for a human operator to conduct the easiest ingress and egress motion. However, acquiring motion data from existing methods provides only unrealistic motion or requires a great amount of time. This not only leads to an increased time consumption for a product development, but also causes inefficiency of the overall design process. To solve such problems, this research proposes an algorithm to rapidly and accurately predict full-body human motion using an artificial neural network (ANN) and a motion database, as the design parameters are varied. To achieve this goal, this study refers to the processes behind human motor learning procedures. According to the previous research, human generate new motion based on past motion experience when they encounter new environments. Based on this principle, we constructed a motion capture database. To construct the database, motion capture experiments were performed in various environments using an optical motion capture system. To generate full-body human motion using this data, a generalized regression neural network (GRNN) was used. The proposed algorithm not only guarantees rapid and accurate results but also overcomes the ambiguity of the human motion objective function, which has been pointed out as a limitation of optimization-based research. Statistical criteria were utilized to confirm the similarity between the generated motion and actual human motion. Our research provides the basis for a rapid motion prediction algorithm that can include a variety of environmental variables. This research contributes to an increase in the usability of digital human models, and it can be applied to various research fields.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Kim Y,Soo Choi E,Seo J,Choi WS,Lee J,Lee K

doi

10.1016/j.jbiomech.2018.12.009

subject

Has Abstract

pub_date

2019-02-14 00:00:00

pages

27-35

eissn

0021-9290

issn

1873-2380

pii

S0021-9290(18)30899-6

journal_volume

84

pub_type

杂志文章
  • The effects of groove height and substrate stiffness on C. elegans locomotion.

    abstract::The physical environment surrounding an animal has a significant impact on its behavior. The nematode Caenorhabditis elegans (C. elegans) has proved to be an excellent choice for understanding the adaptability of organisms crawling on soft surfaces. In this work, we investigate the modulation of C. elegans' behavioral...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.02.015

    authors: Parida L,Ghosh UU,Padmanabhan V

    更新日期:2017-04-11 00:00:00

  • Statistical osteoporosis models using composite finite elements: a parameter study.

    abstract::Osteoporosis is a widely spread disease with severe consequences for patients and high costs for health care systems. The disease is characterised by a loss of bone mass which induces a loss of mechanical performance and structural integrity. It was found that transverse trabeculae are thinned and perforated while ver...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.06.017

    authors: Wolfram U,Schwen LO,Simon U,Rumpf M,Wilke HJ

    更新日期:2009-09-18 00:00:00

  • Effect of wedging on the flow characteristics past tilting disc aortic valve prosthesis.

    abstract::To evaluate the efficacy of implanting a tilting disc aortic valve prosthesis in an angulated (wedged) supra-annular position, an in vitro experimental study was performed. The aortic valve prosthesis was mounted in an axi-symmetric valve chamber in a wedged position and incorporated in a mock circulatory system. Meas...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(86)90150-8

    authors: Chandran KB,Fatemi R,Hiratzka LF,Harris C

    更新日期:1986-01-01 00:00:00

  • Different methods to estimate total power and its components during lifting.

    abstract::A more fundamental understanding about the act of manual lifting can be provided by the assessment of the total production of power and the power generated in joints. The present study is concerned with the validity of the estimations of these parameters. Four subjects lifted an 18.8 kg load while they were filmed and...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(92)90045-3

    authors: de Looze MP,Bussmann JB,Kingma I,Toussaint HM

    更新日期:1992-09-01 00:00:00

  • Sensitivity analysis of muscle properties and impact parameters on head injury risk in American football.

    abstract::Head injuries frequently occur in American football and other contact sports. Uncertainty on the effects of cervical muscle properties on head injury risk may be due to the limitations of previous observational studies. This simulation study employs a musculoskeletal model of the head and neck to investigate the effec...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.109411

    authors: Mortensen JD,Vasavada AN,Merryweather AS

    更新日期:2020-02-13 00:00:00

  • Using the loading response peak for defining gait cycle timing: A novel solution for the double-belt problem.

    abstract::Split-belt treadmills (SBTM) contain force plates under each belt that measure ground reaction force (GRF). Initial contact (IC) detection for each gait cycle obtained from the GRF is used for calculating temporal gait parameters (e.g., gait variability, step time, stride time). Occasionally, the participant steps wit...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109963

    authors: Ben-Gal O,Benady A,Zadik S,Doniger GM,Schnaider Beeri M,Plotnik M

    更新日期:2020-09-18 00:00:00

  • Muscle fatigue does not lead to increased instability of upper extremity repetitive movements.

    abstract::Muscle fatigue alters neuromuscular responses. This may lead to increased sensitivity to perturbations and possibly to subsequent injury risk. We studied the effects of muscle fatigue on movement stability during a repetitive upper extremity task. Twenty healthy young subjects performed a repetitive work task, similar...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.11.001

    authors: Gates DH,Dingwell JB

    更新日期:2010-03-22 00:00:00

  • Laterality in the gallop gait of horses.

    abstract::Bilateral asymmetry in gallop stride limb contact patterns of four Quarter Horse fillies was documented by high-speed cinematography. Horses were filmed with rider by two cameras simultaneously while galloping along a straightaway. Even though signaled for each gallop lead an equivalent number of times, horses frequen...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(87)90285-5

    authors: Deuel NR,Lawrence LM

    更新日期:1987-01-01 00:00:00

  • The mechanics of atherosclerotic plaque rupture by inclusion/matrix interfacial decohesion.

    abstract::Histological investigation along with finite element analysis of arterial wall/atherosclerotic plaque geometries indicates the paradoxical result that ruptures often occur at sites with predicted stresses of half the plaque cap strength. Recent experiments have revealed calcified cells within the cap suggesting that t...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.06.012

    authors: Nguyen CM,Levy AJ

    更新日期:2010-10-19 00:00:00

  • Unique behavior of dermal cells from regenerative mammal, the African Spiny Mouse, in response to substrate stiffness.

    abstract::The African Spiny Mouse (Acomys spp.) is a unique outbred mammal capable of full, scar-free skin regeneration. In vivo, we have observed rapid reepithelialization and deposition of normal dermis in Acomys after wounding. Acomys skin also has a lower modulus and lower elastic energy storage than normal lab mice, Mus mu...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.10.005

    authors: Stewart DC,Serrano PN,Rubiano A,Yokosawa R,Sandler J,Mukhtar M,Brant JO,Maden M,Simmons CS

    更新日期:2018-11-16 00:00:00

  • Lumbar muscle force estimation using a subject-invariant 5-parameter EMG-based model.

    abstract::The use of electromyographic measures, in concert with modeled or empirical representations of muscle physiology, is a common approach for estimation of muscle force. Existing models of the lumbar musculature have allowed model parameters to vary for an individual subject. While this approach improves apparent predict...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(98)00055-4

    authors: Nussbaum MA,Chaffin DB

    更新日期:1998-07-01 00:00:00

  • Muscle fascicle and series elastic element length changes along the length of the human gastrocnemius during walking and running.

    abstract::Ultrasound imaging has recently been used to distinguish the length changes of muscle fascicles from those of the whole muscle tendon complex during real life movements. The complicated three-dimensional architecture of pennate muscles can however cause heterogeneity in the length changes along the length of a muscle....

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2005.10.035

    authors: Lichtwark GA,Bougoulias K,Wilson AM

    更新日期:2007-01-01 00:00:00

  • The effect on patellofemoral joint stability of selective cutting of lateral retinacular and capsular structures.

    abstract::Patient selection for lateral retinacular release (LRR) and its efficacy are controversial. Iatrogenic medial subluxation can occur with inappropriate LRR. The aim of this study was to determine the reduction in patellofemoral stability with progressively more extensive LRR. The force required to displace the patella ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.11.003

    authors: Merican AM,Kondo E,Amis AA

    更新日期:2009-02-09 00:00:00

  • Impact of transversal calf muscle loading on plantarflexion.

    abstract::Muscle compression commonly occurs in daily life (for instance wearing backpacks or compression garments, and during sitting). However, the effects of the compression on contraction dynamics in humans are not well examined. The aim of the study was to quantify the alterations of contraction dynamics and muscle archite...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.01.011

    authors: Stutzig N,Ryan D,Wakeling JM,Siebert T

    更新日期:2019-03-06 00:00:00

  • Nonlinear finite element simulation to elucidate the efficacy of slit arteriotomy for end-to-side arterial anastomosis in microsurgery.

    abstract::The slit arteriotomy for end-to-side arterial microanastomosis is a technique used to revascularize free flaps in reconstructive surgery. Does a slit open to a width sufficient for blood supply? How is the slit opening affected by factors, such as arterial wall thickness and material stiffness? To answer these questio...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2004.12.015

    authors: Gu H,Chua A,Tan BK,Chew Hung K

    更新日期:2006-01-01 00:00:00

  • Vocal fold contact patterns based on normal modes of vibration.

    abstract::The fluid-structure interaction and energy transfer from respiratory airflow to self-sustained vocal fold oscillation continues to be a topic of interest in vocal fold research. Vocal fold vibration is driven by pressures on the vocal fold surface, which are determined by the shape of the glottis and the contact betwe...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.04.011

    authors: Smith SL,Titze IR

    更新日期:2018-05-17 00:00:00

  • Intravoxel bone micromechanics for microCT-based finite element simulations.

    abstract::While micro-FE simulations have become a standard tool in computational biomechanics, the choice of appropriate material properties is still a relevant topic, typically involving empirical grey value-to-elastic modulus relations. We here derive the voxel-specific volume fractions of mineral, collagen, and water, from ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.06.036

    authors: Blanchard R,Dejaco A,Bongaers E,Hellmich C

    更新日期:2013-10-18 00:00:00

  • Altered osteogenic commitment of human mesenchymal stem cells by ERM protein-dependent modulation of cellular biomechanics.

    abstract::Cellular mechanics is known to play an important role in many cellular functions including adhesion, migration, proliferation, and differentiation. Human mesenchymal stem cells (hMSCs) demonstrate unique mechanical properties distinct from fully differentiated cells. This observation suggests that the stem cell mechan...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.07.024

    authors: Titushkin I,Cho M

    更新日期:2011-10-13 00:00:00

  • Comparison of partial least squares regression and principal component regression for pelvic shape prediction.

    abstract::This paper studied two different regression techniques for pelvic shape prediction, i.e., the partial least square regression (PLSR) and the principal component regression (PCR). Three different predictors such as surface landmarks, morphological parameters, or surface models of neighboring structures were used in a c...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2012.11.005

    authors: Schumann S,Nolte LP,Zheng G

    更新日期:2013-01-04 00:00:00

  • Influence of the renal artery ostium flow diverter on hemodynamics and atherogenesis.

    abstract::The structure and function of the renal artery ostium flow diverter on the caudal side of the renal branch point were previously reported; in this study, we further evaluate the diverter׳s possible functions. The protrusion of this structure into the abdominal aorta suggests that the diverter may preferentially direct...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.03.006

    authors: Albert S,Balaban RS,Neufeld EB,Rossmann JS

    更新日期:2014-05-07 00:00:00

  • The range of axial rotation of the glenohumeral joint.

    abstract::There is a paucity of data in the literature on the restraining effects of the glenohumeral (GH) ligaments; cadaveric testing is one of the best methods for determining the function of these types of tissues. The aim of this work was to commission a custom-made six degrees of freedom (dof) joint loading apparatus and ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.03.007

    authors: Southgate DF,Hill AM,Alexander S,Wallace AL,Hansen UN,Bull AM

    更新日期:2009-06-19 00:00:00

  • The reliability of humerothoracic angles during arm elevation depends on the representation of rotations.

    abstract::The reliability of joint rotation measurements is an issue of major interest, especially in clinical applications. The effect of instrumental errors and soft tissue artifacts on the variability of human motion measures is well known, but the influence of the representation of joint motion has not yet been studied. The...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.12.045

    authors: López-Pascual J,Cáceres ML,De Rosario H,Page Á

    更新日期:2016-02-08 00:00:00

  • An instrumented, dynamic test for anterior laxity of the ankle joint complex.

    abstract::Evaluation of anterior laxity of the ankle joint complex is a difficult clinical problem. Currently, the prime determinant for anterolateral ligament function is the subjective manual examination of anterior laxity of the ankle joint complex. An instrumented dynamic test was developed for objective measurement of ante...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章

    doi:10.1016/s0021-9290(02)00189-6

    authors: Kerkhoffs GM,Blankevoort L,Schreurs AW,Jaspers JE,van Dijk CN

    更新日期:2002-12-01 00:00:00

  • EMG and force production of some human shoulder muscles during isometric abduction.

    abstract::Surface EMG was recorded in four subjects on three different occasions from the three parts of the deltoid, the clavicular part of the pectoralis major and from the infraspinatus muscles at different angles of abduction, in the frontal and scapular plane. The integrated EMG was related to the maximum values found for ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(85)90037-5

    authors: Ringelberg JA

    更新日期:1985-01-01 00:00:00

  • Falls resulting from a laboratory-induced slip occur at a higher rate among individuals who are obese.

    abstract::Falls due to slipping are a serious concern, with slipping estimated to cause 40-50% of all fall-related injuries. Epidemiological data indicates that older and obese adults experience more falls than young, non-obese individuals. An increasingly heavier and older U.S. population and workforce may be exacerbating the ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.01.018

    authors: Allin LJ,Wu X,Nussbaum MA,Madigan ML

    更新日期:2016-03-21 00:00:00

  • A rigid body model for the assessment of glenohumeral joint mechanics: Influence of osseous defects on range of motion and dislocation.

    abstract::The purpose of this study was to employ subject-specific computer models to evaluate the interaction of glenohumeral range-of-motion and Hill-Sachs humeral head bone defect size on engagement and shoulder dislocation. We hypothesized that the rate of engagement would increase as defect size increased, and that greater...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.11.001

    authors: Welsh MF,Willing RT,Giles JW,Athwal GS,Johnson JA

    更新日期:2016-02-29 00:00:00

  • Reproducibility analysis of upper limbs reachable workspace, and effects of acquisition protocol, sex and hand dominancy.

    abstract::None of the physical testing, nor the goniometers currently used to assess upper limb function have a high validity, sensitivity or reliability. The reachable workspace, i.e. the area covered by the farthest points a subject can reach by hand without moving his/her body, shows promise but has yet to be validated, part...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.12.010

    authors: Clément J,Raison M,Rouleau DM

    更新日期:2018-02-08 00:00:00

  • Analysis of swimmers' velocity during the underwater gliding motion following grab start.

    abstract::The purpose of this study was to determine the swimmers' loss of speed during the underwater gliding motion of a grab start. This study also set out to determine the kinematical variables influencing this loss of speed. Eight French national-level swimmers participated in this study. The swimmers were filmed using 4 m...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.03.032

    authors: Elipot M,Hellard P,Taïar R,Boissière E,Rey JL,Lecat S,Houel N

    更新日期:2009-06-19 00:00:00

  • Mechanical recovery of dentin following remineralization in vitro--an indentation study.

    abstract::This study sought to gain insights into the steps leading to remineralization and mechanical recovery of hydrated dentin. Mechanical recovery in water was hypothesized to result from effective mineral matrix binding and to occur from the innermost regions outwards due to an increase in the number of nucleation sites. ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.09.005

    authors: Bertassoni LE,Habelitz S,Marshall SJ,Marshall GW

    更新日期:2011-01-04 00:00:00

  • Modelling the mechanical effect of muscles with large attachment sites: application to the shoulder mechanism.

    abstract::A general theory is described for deriving the mechanical effect of muscles with large attachment sites. In a cadaver experiment the complete attachment sites and bundle distribution of 16 muscles of the shoulder mechanism were recorded. These data were used to calculate the mechanical effect, i.e. the resulting force...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(91)90007-a

    authors: Van der Helm FC,Veenbaas R

    更新日期:1991-01-01 00:00:00