The reliability of humerothoracic angles during arm elevation depends on the representation of rotations.

Abstract:

:The reliability of joint rotation measurements is an issue of major interest, especially in clinical applications. The effect of instrumental errors and soft tissue artifacts on the variability of human motion measures is well known, but the influence of the representation of joint motion has not yet been studied. The aim of the study was to compare the within-subject reliability of three rotation formalisms for the calculation of the shoulder elevation joint angles. Five repetitions of humeral elevation in the scapular plane of 27 healthy subjects were recorded using a stereophotogrammetry system. The humerothoracic joint angles were calculated using the YX'Y" and XZ'Y" Euler angle sequences and the attitude vector. A within-subject repeatability study was performed for the three representations. ICC, SEM and CV were the indices used to estimate the error in the calculation of the angle amplitudes and the angular waveforms with each method. Excellent results were obtained in all representations for the main angle (elevation), but there were remarkable differences for axial rotation and plane of elevation. The YX'Y" sequence generally had the poorest reliability in the secondary angles. The XZ'Y' sequence proved to be the most reliable representation of axial rotation, whereas the attitude vector had the highest reliability in the plane of elevation. These results highlight the importance of selecting the method used to describe the joint motion when within-subjects reliability is an important issue of the experiment. This may be of particular importance when the secondary angles of motions are being studied.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

López-Pascual J,Cáceres ML,De Rosario H,Page Á

doi

10.1016/j.jbiomech.2015.12.045

subject

Has Abstract

pub_date

2016-02-08 00:00:00

pages

502-6

issue

3

eissn

0021-9290

issn

1873-2380

pii

S0021-9290(16)00003-8

journal_volume

49

pub_type

杂志文章
  • 3D Imaging of vascular networks for biophysical modeling of perfusion distribution within the heart.

    abstract::One of the main determinants of perfusion distribution within an organ is the structure of its vascular network. Past studies were based on angiography or corrosion casting and lacked quantitative three dimensional, 3D, representation. Based on branching rules and other properties derived from such imaging, 3D vascula...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章,评审

    doi:10.1016/j.jbiomech.2012.11.027

    authors: van den Wijngaard JP,Schwarz JC,van Horssen P,van Lier MG,Dobbe JG,Spaan JA,Siebes M

    更新日期:2013-01-18 00:00:00

  • Mechanical mechanisms of thrombosis in intact bent microvessels of rat mesentery.

    abstract::The hypothesis that thrombus can be induced by localized shear stresses/rates, such as in the bent/stretched microvessels, was tested both experimentally and computationally. Our newly designed in vivo experiments were performed on the microvessels (post-capillary venules, 20-50 microm diameter) of rat mesentery. Thes...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.06.013

    authors: Liu Q,Mirc D,Fu BM

    更新日期:2008-08-28 00:00:00

  • The impact of boundary conditions on surface curvature of polypropylene mesh in response to uniaxial loading.

    abstract::Exposure following pelvic organ prolapse repair has been observationally associated with wrinkling of the implanted mesh. The purpose of this study was to quantify the impact of variable boundary conditions on the out-of-plane deformations of mesh subjected to tensile loading. Using photogrammetry and surface curvatur...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.02.061

    authors: Barone WR,Amini R,Maiti S,Moalli PA,Abramowitch SD

    更新日期:2015-06-25 00:00:00

  • In-vivo analysis of sliding distance and cross-shear in Bi-cruciate retaining total knee arthroplasty.

    abstract::Polyethylene remains the most popular bearing material for total knee arthroplasty (TKA). Despite its widespread use, wear continue to be one of major factors implicated in revision surgery. Sliding distance, cross-shear, and contact stress are the major factors influencing polyethylene wear. As previous studies have ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.06.009

    authors: Arauz P,Peng Y,An S,Kwon YM

    更新日期:2018-08-22 00:00:00

  • A minimally disruptive technique for measuring intervertebral disc pressure in vitro: application to the cervical spine.

    abstract::A novel technique to measure in vitro disc pressures in human cervical spine specimens was developed. A miniature pressure transducer was used and an insertion technique was designed to minimise artefacts due to insertion. The technique was used to measure the intradiscal pressure in cervical spines loaded in pure axi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(00)00205-0

    authors: Cripton PA,Dumas GA,Nolte LP

    更新日期:2001-04-01 00:00:00

  • High frequency components of bone strain in dogs measured during various activities.

    abstract::Rubin et al. [J. Biomechanics 23, 43-54 (1990)] proposed that high frequency bone strains in the 15-30 Hz range might have significant influence on the morphological adaptation of bone tissue. We sought to further their findings by determining the magnitude of high frequency strains during various activities. We measu...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(95)80005-0

    authors: Turner CH,Yoshikawa T,Forwood MR,Sun TC,Burr DB

    更新日期:1995-01-01 00:00:00

  • Modelling the mechanical effect of muscles with large attachment sites: application to the shoulder mechanism.

    abstract::A general theory is described for deriving the mechanical effect of muscles with large attachment sites. In a cadaver experiment the complete attachment sites and bundle distribution of 16 muscles of the shoulder mechanism were recorded. These data were used to calculate the mechanical effect, i.e. the resulting force...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(91)90007-a

    authors: Van der Helm FC,Veenbaas R

    更新日期:1991-01-01 00:00:00

  • Is Achilles tendon compliance optimised for maximum muscle efficiency during locomotion?

    abstract::Tendon elasticity is important for economical locomotion; however it is unknown whether tendon stiffness is appropriate to achieve an optimal efficiency in various muscles. Here we test the hypothesis that the Achilles tendon is of an appropriate stiffness to maximise medial gastrocnemius muscle efficiency during loco...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2006.07.025

    authors: Lichtwark GA,Wilson AM

    更新日期:2007-01-01 00:00:00

  • Towards mechanical characterization of intact endarterectomy samples of carotid arteries during inflation using Echo-CT.

    abstract::In this study, an experimental framework is described that allows pressurization of intact, human atherosclerotic carotid samples (inflation testing), in combination with ultrasound imaging. Eight fresh human carotid endarterectomy samples were successfully pressurized and tested. About 36 2-D (+t) ultrasound datasets...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.01.016

    authors: Boekhoven RW,Rutten MC,van Sambeek MR,van de Vosse FN,Lopata RG

    更新日期:2014-03-03 00:00:00

  • Interlimb coordination in body-weight supported locomotion: A pilot study.

    abstract::Locomotion involves complex neural networks responsible for automatic and volitional actions. During locomotion, motor strategies can rapidly compensate for any obstruction or perturbation that could interfere with forward progression. In this pilot study, we examined the contribution of interlimb pathways for evoking...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.04.042

    authors: Seiterle S,Susko T,Artemiadis PK,Riener R,Igo Krebs H

    更新日期:2015-08-20 00:00:00

  • Differences in stretch-shortening cycle and residual force enhancement between muscles.

    abstract::It has been suggested that cross bridge kinetics and residual force enhancement (RFE) affect force in the stretch-shortening cycle (SSC). Because cross bridge kinetics and titin isoforms, which are thought to be related to RFE, differ between muscles, the SSC effect may be also muscle-dependent. Thus, we compared the ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.110040

    authors: Fukutani A,Herzog W

    更新日期:2020-11-09 00:00:00

  • Two strategies of transferring from sit-to-stand; the activation of monoarticular and biarticular muscles.

    abstract::In this study, two different strategies of rising from a chair were compared, using integrated biomechanical and electromyographic analyses. Nine healthy subjects were instructed to rise using two different strategies: natural sit-to-stand transfer (NSTS) and a sit-to-stand transfer with full flexion of the trunk (FST...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(94)90039-6

    authors: Doorenbosch CA,Harlaar J,Roebroeck ME,Lankhorst GJ

    更新日期:1994-11-01 00:00:00

  • Associations of hamstring and triceps surae muscle spasticity and stance phase gait kinematics in children with spastic diplegic cerebral palsy.

    abstract::Clinical decisions on interventions to improve function in children with cerebral palsy (CP) are based, in part, on hypothesized interactions amongst physical signs of CP and functional deficits. However, a knowledge gap exists regarding associations between spasticity and gait function. This study quantified associat...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.110218

    authors: Bowal N,Nettel-Aguirre A,Ursulak G,Condliffe E,Robu I,Goldstein S,Emery C,Ronsky JL,Kuntze G

    更新日期:2021-01-16 00:00:00

  • Implant size and mechanical properties influence the failure of the adhesive bond between cartilage implants and native tissue in a finite element analysis.

    abstract::Implanted cartilage replacements (ICRs) are a promising approach to restore the functionality of joints with partial- and full-thickness articular cartilage lesions. Two major hurdles hindering successful repair of cartilage injuries with ICRs are their inadequate mechanical properties and fixation into the defect are...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.03.019

    authors: Vahdati A,Wagner DR

    更新日期:2013-05-31 00:00:00

  • Estimation of unmeasured ground reaction force data based on the oscillatory characteristics of the center of mass during human walking.

    abstract::To enhance the wearability of portable motion-monitoring devices, the size and number of sensors are minimized, but at the expense of quality and quantity of data collected. For example, owing to the size and weight of low-frequency force transducers, most currently available wearable gait measurement systems provide ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.01.046

    authors: Ryu HX,Park S

    更新日期:2018-04-11 00:00:00

  • An activatable molecular spring reduces muscle tearing during extreme stretching.

    abstract::The purpose of this study was to determine failure stresses and failure lengths of actively and passively stretched myofibrils. As expected, myofibrils failed at average sarcomere lengths (about 6-7μm) that vastly exceeded sarcomere lengths at which actin-myosin filament overlap ceases to exist (4μm) and thus actin-my...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.07.016

    authors: Leonard TR,Joumaa V,Herzog W

    更新日期:2010-11-16 00:00:00

  • Heterogeneous linear elastic trabecular bone modelling using micro-CT attenuation data and experimentally measured heterogeneous tissue properties.

    abstract::High-resolution voxel-based finite element software, such as FEEBE developed at the NCBES, is widely used for studying trabecular bone at the micro-scale. A new approach to determine heterogeneous bone tissue material properties for computational models was proposed in this study. The specimen-specific range of tissue...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.05.014

    authors: Harrison NM,McDonnell PF,O'Mahoney DC,Kennedy OD,O'Brien FJ,McHugh PE

    更新日期:2008-08-07 00:00:00

  • Computational modeling of neuromuscular response to swing-phase robotic knee extension assistance in cerebral palsy.

    abstract::Predicting subject-specific responses to exoskeleton assistance may aid in maximizing functional gait outcomes, such as achieving full knee-extension at foot contact in individuals with crouch gait from cerebral palsy (CP). The purpose of this study was to investigate the role of volitional and non-volitional muscle a...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.02.025

    authors: Lerner ZF,Damiano DL,Bulea TC

    更新日期:2019-04-18 00:00:00

  • Fluid-structure interaction simulation of artificial textile reinforced aortic heart valve: Validation with an in-vitro test.

    abstract::Prosthetic heart valves deployed in the left heart (aortic and mitral) are subjected to harsh hemodynamical conditions. Most of the tissue engineered heart valves have been developed for the low pressure pulmonary position because of the difficulties in fabricating a mechanically strong valve, able to withstand the sy...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.07.018

    authors: Sodhani D,Reese S,Aksenov A,Soğanci S,Jockenhövel S,Mela P,Stapleton SE

    更新日期:2018-09-10 00:00:00

  • Failure of mineralized collagen fibrils: modeling the role of collagen cross-linking.

    abstract::Experimental evidence demonstrates that collagen cross-linking in bone tissue significantly influences its deformation and failure behavior yet difficulties exist in determining the independent biomechanical effects of collagen cross-linking using in vitro and in vivo experiments. The aim of this study is to use a nan...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.02.017

    authors: Siegmund T,Allen MR,Burr DB

    更新日期:2008-01-01 00:00:00

  • Fracture properties of bovine tibial bone.

    abstract::Linear elastic fracture mechanics predicts that the fracture stress of precracked materials is dependent on the length of the initial crack tip radius of curvature, as supported by the Griffith and Inglis equations. In order to determine the applicability of these equations and the effects of other variables, tensile ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(86)90187-9

    authors: Moyle DD,Gavens AJ

    更新日期:1986-01-01 00:00:00

  • Proximal femur elastic behaviour is the same in impact and constant displacement rate fall simulation.

    abstract::Understanding proximal femur fracture may yield new targets for fracture prevention screening and treatment. The goal of this study was to characterize force-displacement and failure behaviours in the proximal femur between displacement control and impact loading fall simulations. Twenty-one human proximal femurs were...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.06.040

    authors: Gilchrist S,Nishiyama KK,de Bakker P,Guy P,Boyd SK,Oxland T,Cripton PA

    更新日期:2014-11-28 00:00:00

  • Single-subject analysis reveals variation in knee mechanics during step landing.

    abstract:PURPOSE:Evidence concerning the alteration of knee function during landing suffers from a lack of consensus. This uncertainty can be attributed to methodological flaws, particularly in relation to the statistical analysis of variable human movement data. The aim of this study was to compare single-subject and group ana...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.jbiomech.2012.05.046

    authors: Scholes CJ,McDonald MD,Parker AW

    更新日期:2012-08-09 00:00:00

  • The consistency of maximum running speed measurements in humans using a feedback-controlled treadmill, and a comparison with maximum attainable speed during overground locomotion.

    abstract::Consistent measurement of maximum running speed overground is problematic due to the difficulty in precise, continual measurement of speed, and the substantial workload in accelerating the body promoting the onset of fatigue. Treadmills remove the requirement for acceleration which enables more repeats. They also allo...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.07.024

    authors: Bowtell MV,Tan H,Wilson AM

    更新日期:2009-11-13 00:00:00

  • Twenty-fold difference in hemodynamic wall shear stress between murine and human aortas.

    abstract::Endothelial cells regulate vascular tone and mural remodelling in a shear-dependent manner that is commonly assumed to keep wall shear stress constant across arteries and species. Allometric arguments show that aortic flow velocity is constant across species, a deduction that is consistent with much experimental data,...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2006.07.020

    authors: Weinberg PD,Ross Ethier C

    更新日期:2007-01-01 00:00:00

  • Continuum modeling of deformation and aggregation of red blood cells.

    abstract::In order to gain better understanding for rheology of an isolated red blood cell (RBC) and a group of multiple RBCs, new continuum models for describing mechanical properties of cellular structures of an RBC and inter-cellular interactions among multiple RBCs are developed. The viscous property of an RBC membrane, whi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.11.027

    authors: Yoon D,You D

    更新日期:2016-07-26 00:00:00

  • What is the role of the convective current density in the real-time calcium response of cultured bone cells to fluid flow?

    abstract::Cultured cells subjected to fluid flow are exposed to mechanical forces and electrokinetic forces. The convective current establishes an electrokinetic force created by the flow-dependent transport of mobile ions in the media over the charged cell surfaces. This current can be expressed as a current density, the curre...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(96)84535-0

    authors: Hung CT,Allen FD,Pollack SR,Brighton CT

    更新日期:1996-11-01 00:00:00

  • Non-Newtonian blood flow in human right coronary arteries: steady state simulations.

    abstract::This study looks at blood flow through four different right coronary arteries, which have been reconstructed from bi-plane angiograms. Five non-Newtonian blood models, as well as the usual Newtonian model of blood viscosity, are used to study the wall shear stress in each of these arteries at a particular point in the...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2003.09.016

    authors: Johnston BM,Johnston PR,Corney S,Kilpatrick D

    更新日期:2004-05-01 00:00:00

  • The exoskeletal structure and tensile loading behavior of an ant neck joint.

    abstract::Insects have evolved mechanical form and function over millions of years. Ants, in particular, can lift and carry heavy loads relative to their body mass. Loads are lifted with the mouthparts, transferred through the neck joint to the thorax, and distributed over six legs and tarsi (feet) that anchor to the supporting...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.10.053

    authors: Nguyen V,Lilly B,Castro C

    更新日期:2014-01-22 00:00:00

  • Design of next generation total disk replacements.

    abstract::To improve the treatments for low back pain, new designs of total disk replacement have been proposed. The question is how well these designs can act as a functional replacement of the intervertebral disk. Four finite element models were made, for four different design concepts, to determine how well they can mimic th...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.09.017

    authors: van den Broek PR,Huyghe JM,Wilson W,Ito K

    更新日期:2012-01-03 00:00:00