Abstract:
:Anterior cruciate ligament (ACL) volume and T2∗ relaxation times from magnetic resonance (MR) images have been previously shown to predict the structural properties of healing ligaments. We investigated whether MR imaging scan resolution and condition (in vivo, in situ, or ex vivo) affected ACL volume and T2∗ relaxation times in intact ligaments. ACLs of 14 pigs were imaged using a 3T scanner and a six-channel flexcoil using at least two of four possible scan conditions: (1) in vivo moderate resolution (n=14); (2) in vivo high resolution (n=7); (3) in situ high resolution acquired within 60 minutes of euthanasia (n=6); and (4) ex vivo high resolution following hind limb disarticulation and one freeze-thaw cycle (n=7). T2∗ relaxation times were mapped to the ACL voxels. The total ACL volume was then divided into four sub-volumes (Vol1-4) based on predetermined increasing ranges of T2∗ times. ACL T2∗ statistics (first quartile, median, and standard deviation (SD)) were computed. Scan resolution had no effect on the total ACL volume, but Vol1 and first quartile T2∗ times decreased with high resolution and in situ/ex vivo scan conditions. The most dramatic differences in T2∗ summary statistics were between in vivo moderate and ex vivo high resolution scan conditions that included a freeze-thaw cycle: ACL T2∗ SD increased by over 50% in 9 animals, and more than 90% in 4 animals. Our results indicated that T2∗-based prediction models to quantify in vivo structural properties of healing ligaments should be based on high resolution in vivo MR scan conditions.
journal_name
J Biomechjournal_title
Journal of biomechanicsauthors
Beveridge JE,Walsh EG,Murray MM,Fleming BCdoi
10.1016/j.jbiomech.2017.03.010subject
Has Abstractpub_date
2017-05-03 00:00:00pages
117-121eissn
0021-9290issn
1873-2380pii
S0021-9290(17)30158-6journal_volume
56pub_type
杂志文章abstract::The purpose of the study was to compare the effects of a feedback-controlled treadmill (FeedbackTM) to a traditional fixed-speed treadmill (FixedTM) on spatiotemporal gait means, variability, and dynamics. The study also examined inter-session reliability when using the FeedbackTM. Ten young adults walked on the Feedb...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2018.11.051
更新日期:2019-01-23 00:00:00
abstract::Specific spinal postures and physical activities have been linked to low back pain (LBP) but previous reviews have produced contrasting outcomes. This umbrella review examined (1) what relationship, if any, is evident between specific spinal postures or physical activities and LBP; (2) the quality of existing systemat...
journal_title:Journal of biomechanics
pub_type: 杂志文章,评审
doi:10.1016/j.jbiomech.2019.08.006
更新日期:2020-03-26 00:00:00
abstract::We assessed the local distribution of bone mechanical properties on a micro-nano-scale and its correlation to strain distribution. Left tibia samples were obtained from 5-month old female Sprague Dawley rats, including baseline control (n=9) and hindlimb suspended (n=9) groups. Elastic modulus was measured by nanoinde...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2015.11.052
更新日期:2016-01-25 00:00:00
abstract::The purpose of the current investigation was to use finite element analysis to quantify the complete strain field for the membranes of the Flexercell apparatus, a device extensively used to study the effects of mechanical loading on cultured cells. Four vacuum pressure simulations were run for the membrane for both th...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2004.02.022
更新日期:2004-12-01 00:00:00
abstract::An anatomically accurate human upper airway model was constructed from multiple magnetic resonance imaging axial scans. This model was used to conduct detailed Computational Fluid Dynamics (CFD) simulations during expiration, to investigate the fluid flow in the airway regions where obstruction could occur. An identic...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2009.03.035
更新日期:2009-07-22 00:00:00
abstract::Lymphatic valves facilitate the lymphatic system's role in maintaining fluid homeostasis. Malformed valves are found in several forms of primary lymphœdema, resulting in incurable swelling of the tissues and immune dysfunction. Their experimental study is complicated by their small size and operation in low pressure a...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2017.09.040
更新日期:2017-11-07 00:00:00
abstract::Gait analysis is a quantitative, non-invasive technique that can be used to investigate functional changes in animal models of musculoskeletal disease. Changes in ground reaction forces following injury have been observed that coincide with differences in tissue mechanical and histological properties during healing. H...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2015.12.027
更新日期:2016-02-08 00:00:00
abstract::This contribution is concerned with the modelling of PMMA-based bone cement polymerisation process and the associated heat effect. While existing models use description in terms of the so-called polymerisation fraction to fit the experimental data, the new model is constructed in such a way as to mimic the chemical pr...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2004.06.021
更新日期:2005-07-01 00:00:00
abstract::Vessel geometry for numerical analysis is generally obtained by computed tomography (CT) or magnetic resonance imaging (MRI) and intravascular ultrasound (IVUS). Most medical imaging is obtained from patients for hemodynamic analysis due to the properties of vascular disease and the difficulties in angiography. To pre...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2012.04.003
更新日期:2012-06-01 00:00:00
abstract::This study sought to gain insights into the steps leading to remineralization and mechanical recovery of hydrated dentin. Mechanical recovery in water was hypothesized to result from effective mineral matrix binding and to occur from the innermost regions outwards due to an increase in the number of nucleation sites. ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2010.09.005
更新日期:2011-01-04 00:00:00
abstract::This study aimed to evaluate the sex difference in active muscle stiffness of the tibialis anterior muscle (TA) through shear modulus measurements performed using supersonic shear imaging (SSI) technique. Twenty-five women and twenty-one men participated in this study. Joint torque, electromyographic (EMG) activity an...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2016.08.008
更新日期:2016-10-03 00:00:00
abstract::Numerical models commonly account for elastic inhomogeneity in cortical bone using power-law scaling relationships with various measures of tissue density, but limited experimental data exists for anatomic variation in elastic anisotropy. A recent study revealed anatomic variation in the magnitude and anisotropy of el...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2011.04.009
更新日期:2011-06-03 00:00:00
abstract::The potential for wear in UHMWPE components for total knee replacements can be reduced by decreasing the stresses and strains arising from tibial-femoral contact. The conformity of the articular surfaces has a large effect on the resultant stresses, and components that achieve flat medial-lateral contact have been ass...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/s0021-9290(01)00172-5
更新日期:2002-01-01 00:00:00
abstract::Coronary artery disease results in blockages or narrowing of the artery lumen. Drug eluting stents (DES) were developed to replace bare metal stents in an effort to combat re-blocking of the diseased artery following treatment. The numerical models developed within this study focus on representing the changing trends ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2013.09.017
更新日期:2014-01-03 00:00:00
abstract:OBJECTIVES:To assess the ability of a biomechanical impact model to predict the likelihood of distal radius fracture in children using data gathered for a previous epidemiological case-control study of falls from playground equipment. METHODOLOGY:Factor of Risk (FR) values were generated for each of selected subjects ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2004.11.028
更新日期:2006-01-01 00:00:00
abstract::Overdistension of the urinary bladder, secondary to outlet obstruction, causes cellular changes in the bladder wall, including hypertrophy of the smooth muscle cells, which increase bladder mass. To investigate the effects of increased mass on the cystometrogram (CMG), we have developed two mathematical models. In the...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:
更新日期:1996-12-01 00:00:00
abstract::The purpose of this study was to determine the swimmers' loss of speed during the underwater gliding motion of a grab start. This study also set out to determine the kinematical variables influencing this loss of speed. Eight French national-level swimmers participated in this study. The swimmers were filmed using 4 m...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2009.03.032
更新日期:2009-06-19 00:00:00
abstract::The purpose of this study was to investigate the effect of thickness, cross-sectional area and stiffness of intrinsic foot muscles on performance in single-leg stance balance tasks in healthy sedentary young females. This study included a total of 40 healthy sedentary young females between the ages of 19 and 35 years....
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2019.109530
更新日期:2020-01-23 00:00:00
abstract::Mechanical constraints to spine motion can arise in a variety of real-world situations such as when shoulder belts prevent anterior translation of the thorax during automotive collisions. The effect of such constraint on spinal column-spinal cord interaction during injury remains unknown. The purpose of the present st...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2007.06.030
更新日期:2008-01-01 00:00:00
abstract::In vivo measurements of the loads and deformations occurring in orthopaedic implants will allow future improvements to be made. This paper describes an extremely small telemetry for long term measurements with three strain gauges and methods for an absolutely safe implant design. Developed for measuring the load at hi...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(88)90009-7
更新日期:1988-01-01 00:00:00
abstract::Shape plays an important role in determining the biomechanical response of a structure. Specimen-specific finite element (FE) models have been developed to capture the details of the shape of biological structures and predict their biomechanics. Shape, however, can vary considerably across individuals or change due to...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2009.08.036
更新日期:2010-01-19 00:00:00
abstract::During range of motion (max-ROM) tests performed on an isokinetic dynamometer, the mechanical delay between the button press (by the participant to signal their max-ROM) and the stopping of joint rotation resulting from system inertia induces errors in both max-ROM and maximum passive joint moment. The present study a...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2019.05.036
更新日期:2019-07-19 00:00:00
abstract::Ultrasound imaging has recently been used to distinguish the length changes of muscle fascicles from those of the whole muscle tendon complex during real life movements. The complicated three-dimensional architecture of pennate muscles can however cause heterogeneity in the length changes along the length of a muscle....
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2005.10.035
更新日期:2007-01-01 00:00:00
abstract::Whole body vibration (WBV) is a promising tool for counteracting bone loss. Most WBV studies on animals have been performed at acceleration <1g and frequency between 30 and 90Hz. Such WBV conditions trigger bone growth in osteopenia models, but not in healthy animals. In order to test the ability of WBV to promote ost...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2016.04.031
更新日期:2016-06-14 00:00:00
abstract::Head injury is a persistent and costly problem for both children and adults. Globally, approximately 10 million people are hospitalized each year for head injuries. Knowing the structural properties of the head is important for modeling the response of the head in impact, and for providing insights into mechanisms of ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2015.08.024
更新日期:2015-11-05 00:00:00
abstract::Stem-cement and cement-bone interfacial failures as well as cement fractures have been noted in cemented total hip arthroplasty (THA) as the cause of aseptic loosening. Attempts to reduce the risk of femoral component loosening include improving the stem-cement interface by various coatings, using a textured or porous...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2012.12.010
更新日期:2013-03-15 00:00:00
abstract::The use of swim fins has become popular in various water sport activities. While numerous models of swim fin with various innovative shapes have been subjectively designed, the exact influence of the fin characteristics on swimming performance is still much debated, and remains difficult to quantify. To date, the most...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2010.03.031
更新日期:2010-07-20 00:00:00
abstract::Detecting and assessing an individual's gait can be important for medical diagnostic purposes and for developing and guiding follow-on rehabilitation protocols. Thus, an accurate, objective gait classification system has the potential to facilitate earlier diagnosis and improved clinical decision-making. Systems using...
journal_title:Journal of biomechanics
pub_type: 临床试验,杂志文章
doi:10.1016/j.jbiomech.2019.06.009
更新日期:2019-08-27 00:00:00
abstract::We developed an intravaginal instrumented probe (covered with a 10×10 matrix of capacitive sensors) for assessing the three-dimensional (3D) spatiotemporal pressure profile of the vaginal canal. The pressure profile was compared to the pelvic floor (PF) digital assessment, and the reliability of the instrument and rep...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2017.04.035
更新日期:2017-06-14 00:00:00
abstract::This study reports for the first time an estimation of the internal net joint forces and torques on adults' lower limbs and pelvis when walking in shallow water, taking into account the drag forces generated by the movement of their bodies in the water and the equivalent data when they walk on land. A force plate and ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2011.01.017
更新日期:2011-04-07 00:00:00