Validation of computational fluid dynamics methodology used for human upper airway flow simulations.

Abstract:

:An anatomically accurate human upper airway model was constructed from multiple magnetic resonance imaging axial scans. This model was used to conduct detailed Computational Fluid Dynamics (CFD) simulations during expiration, to investigate the fluid flow in the airway regions where obstruction could occur. An identical physical model of the same airway was built using stereo lithography. Pressure and velocity measurements were conducted in the physical model. Both simulations and experiments were performed at a peak expiratory flow rate of 200 L/min. Several different numerical approaches within the FLUENT commercial software framework were used in the simulations; unsteady Large Eddy Simulation (LES), steady Reynolds-Averaged Navier-Stokes (RANS) with two-equation turbulence models (i.e. k-epsilon, standard k-omega, and k-omega Shear Stress Transport (SST)) and with one-equation Spalart-Allmaras model. The CFD predictions of the average wall static pressures at different locations along the airway wall were favorably compared with the experimental data. Among all the approaches, standard k-omega turbulence model resulted in the best agreement with the static pressure measurements, with an average error of approximately 20% over all ports. The highest positive pressures were observed in the retroglossal regions below the epiglottis, while the lowest negative pressures were recorded in the retropalatal region. The latter is a result of the airflow acceleration in the narrow retropalatal region. The largest pressure drop was observed at the tip of the soft palate. This location has the smallest cross section of the airway. The good agreement between the computations and the experimental results suggest that CFD simulations can be used to accurately compute aerodynamic flow characteristics of the upper airway.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Mylavarapu G,Murugappan S,Mihaescu M,Kalra M,Khosla S,Gutmark E

doi

10.1016/j.jbiomech.2009.03.035

subject

Has Abstract

pub_date

2009-07-22 00:00:00

pages

1553-1559

issue

10

eissn

0021-9290

issn

1873-2380

pii

S0021-9290(09)00134-1

journal_volume

42

pub_type

杂志文章
  • Soft tissue artifact compensation by linear 3D interpolation and approximation methods.

    abstract::Several compensation methods estimate bone pose from a cluster of skin-mounted makers, each influenced by soft tissue artifact (STA). In this study, linear 3D interpolation and approximation methods (affine mapping, Kriging and radial basis function (RBF)) and the conventional singular value decomposition (SVD) method...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.06.006

    authors: Dumas R,Cheze L

    更新日期:2009-09-18 00:00:00

  • Interaction forces and interface properties of KIF1A kinesin-alphabeta tubulin complex assessed by molecular dynamics.

    abstract::Kinesin is a microtubule-based motor protein that generates motion involved in intracellular trafficking and cell division. Even if the force-generating and enzymatic properties of kinesin were extensively studied, the molecular basis of its interaction with the microtubule is still not well understood. The aim of the...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.08.014

    authors: Aprodu I,Soncini M,Redaelli A

    更新日期:2008-11-14 00:00:00

  • Comparison of micro-level and continuum-level voxel models of the proximal femur.

    abstract::Continuum-level finite element (FE) models became standard computational tools for the evaluation of bone mechanical behavior from in vivo computed tomography scans. Such scans do not account for the anisotropy of the bone. Instead, local mechanical properties in the continuum-level FE models are assumed isotropic and...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2005.10.027

    authors: Verhulp E,van Rietbergen B,Huiskes R

    更新日期:2006-01-01 00:00:00

  • Reproducibility of energy parameters in the pole vault.

    abstract::The purpose of this study was to analyze the reproducibility of kinematic, dynamometric and derived mechanical energy parameters in the pole vault as a main precondition for the practical applicability of the concept of energy exchange in the pole vault. A total of 46 vaults of six experienced vaulters were analyzed. ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2005.03.027

    authors: Schade F,Arampatzis A,Brüggemann GP

    更新日期:2006-01-01 00:00:00

  • Using regression models to determine the poroelastic properties of cartilage.

    abstract::The feasibility of determining biphasic material properties using regression models was investigated. A transversely isotropic poroelastic finite element model of stress relaxation was developed and validated against known results. This model was then used to simulate load intensity for a wide range of material proper...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.05.028

    authors: Chung CY,Mansour JM

    更新日期:2013-07-26 00:00:00

  • Reprogramming cardiomyocyte mechanosensing by crosstalk between integrins and hyaluronic acid receptors.

    abstract::The elastic modulus of bioengineered materials has a strong influence on the phenotype of many cells including cardiomyocytes. On polyacrylamide (PAA) gels that are laminated with ligands for integrins, cardiac myocytes develop well organized sarcomeres only when cultured on substrates with elastic moduli in the range...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.11.023

    authors: Chopra A,Lin V,McCollough A,Atzet S,Prestwich GD,Wechsler AS,Murray ME,Oake SA,Kresh JY,Janmey PA

    更新日期:2012-03-15 00:00:00

  • Impact responses of the cervical spine: A computational study of the effects of muscle activity, torso constraint, and pre-flexion.

    abstract::Cervical spine injuries continue to be a costly societal problem. Future advancements in injury prevention depend on improved physical and computational models, which are predicated on a better understanding of the neck response during dynamic loading. Previous studies have shown that the tolerance of the neck is depe...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.01.006

    authors: Nightingale RW,Sganga J,Cutcliffe H,Bass CR

    更新日期:2016-02-29 00:00:00

  • An analytical study on the thermal effects of cryosurgery on selective cell destruction.

    abstract::The aim of cryosurgery is to kill cells within a closely defined region maintained at a predetermined low temperature. To effectively kill cells, it is important to be able to predict and control the cooling rate over some critical range of temperatures and freezing states in order to regulate the spatial extent of in...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2005.11.005

    authors: Chua KJ,Chou SK,Ho JC

    更新日期:2007-01-01 00:00:00

  • Control of cellular adhesion and myofibroblastic character with sub-micrometer magnetoelastic vibrations.

    abstract::The effect of sub-cellular mechanical loads on the behavior of fibroblasts was investigated using magnetoelastic (ME) materials, a type of material that produces mechanical vibrations when exposed to an external magnetic AC field. The integration of this functionality into implant surfaces could mitigate excessive fib...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.02.007

    authors: Holmes HR,Vlaisavljevich E,Tan EL,Snyder KL,Ong KG,Rajachar RM

    更新日期:2018-04-11 00:00:00

  • A study of the viability of obtaining a generic animation of the foot while walking for the virtual testing of footwear using dorsal pressures.

    abstract::Establishing the appropriate pressure exerted by the shoe upper over the foot surface is fundamental for the design of specific footwear, although measuring the dorsal pressures can also provide important additional information. In previous works, a virtual simulator to perform studies of comfort and functionality in ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.06.054

    authors: Rupérez MJ,Alemany S,Monserrat C,Olaso J,Alcañíz M,González JC

    更新日期:2009-09-18 00:00:00

  • Validation of the Leap Motion Controller using markered motion capture technology.

    abstract::The Leap Motion Controller (LMC) is a low-cost, markerless motion capture device that tracks hand, wrist and forearm position. Integration of this technology into healthcare applications has begun to occur rapidly, making validation of the LMC׳s data output an important research goal. Here, we perform a detailed evalu...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.04.006

    authors: Smeragliuolo AH,Hill NJ,Disla L,Putrino D

    更新日期:2016-06-14 00:00:00

  • Modela-r as a Froude and Strouhal dimensionless numbers combination for dynamic similarity in running.

    abstract::The aim of this study was to test the hypothesis that running at fixed fractions of Froude (Nfr) and Strouhal (Str) dimensionless numbers combinations induce dynamic similarity between humans of different sizes. Nineteen subjects ran in three experimental conditions, (i) constant speed, (ii) similar speed (Nfr) and (i...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.10.012

    authors: Villeger D,Costes A,Watier B,Moretto P

    更新日期:2014-12-18 00:00:00

  • An ocular biomechanic model for dynamic simulation of different eye movements.

    abstract::Simulating and analysing eye movement is useful for assessing visual system contribution to discomfort with respect to body movements, especially in virtual environments where simulation sickness might occur. It can also be used in the design of eye prosthesis or humanoid robot eye. In this paper, we present two biome...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.02.006

    authors: Iskander J,Hossny M,Nahavandi S,Del Porto L

    更新日期:2018-04-11 00:00:00

  • Marker-less versus marker-based driven musculoskeletal models of the spine during static load-handling activities.

    abstract::Evaluation of workers' body posture in workstations is a prerequisite to estimate spinal loads and assess risk of injury for the subsequent design of preventive interventions. The Microsoft Kinect™ sensor is, in this regard, advantageous over the traditional skin-marker-based optical motion capture systems for being m...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.110043

    authors: Asadi F,Arjmand N

    更新日期:2020-11-09 00:00:00

  • The influence of lower leg configurations on muscle force variability.

    abstract::The maintenance of steady contractions is required in many daily tasks. However, there is little understanding of how various lower limb configurations influence the ability to maintain force. The purpose of the current investigation was to examine the influence of joint angle on various lower-limb constant force cont...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.01.032

    authors: Ofori E,Shim J,Sosnoff JJ

    更新日期:2018-04-11 00:00:00

  • Crushed bone grafts and a collagen membrane are not suitable for enhancing cartilage quality in the regeneration of osteochondral defects--an in vivo study in sheep.

    abstract::Hyaline joint cartilage has only a limited potential for self-repair. Some of the published techniques for osteochondral defect therapy try to improve that potential. In this study, it was hypothesised that one of those surgical techniques, the crushed transplanted bone graft together with a collagen membrane, acceler...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.02.021

    authors: Schell H,Lienau J,Kleemann RU,Schlichting K,Taylor WR,Weiler A,Duda GN

    更新日期:2007-01-01 00:00:00

  • Dominant role of interface over knee angle for cushioning impact loading and regulating initial leg stiffness.

    abstract::For in vivo impact loadings administered under controlled initial conditions, it was hypothesized that larger initial knee angles (IKA) and softer impacting interfaces would reduce impact loading and initial leg stiffness. A human pendulum was used to deliver controlled impacts to the right foot of 21 subjects for thr...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:

    authors: Lafortune MA,Hennig EM,Lake MJ

    更新日期:1996-12-01 00:00:00

  • Alternative measures of toe trajectory more accurately predict the probability of tripping than minimum toe clearance.

    abstract::Tripping is responsible for a large percentage of falls. Minimum toe clearance (MTC) during the swing phase of gait is commonly used to infer the probability of tripping (POT). However, there is limited empirical evidence to support the relationship between these two variables, and other measures of toe trajectory may...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.10.045

    authors: Byju AG,Nussbaum MA,Madigan ML

    更新日期:2016-12-08 00:00:00

  • Evaluation of left ventricular function based on simulated systolic flow dynamics computed from regional wall motion.

    abstract::Left ventricular (LV) chamber flow is undoubtedly influenced by the time-dependent regional motion of the LV wall. In an attempt to obtain diagnostic parameters based on LV chamber flow, we computed the LV chamber, two-dimensional systolic velocity and pressure distribution for two right anterior oblique (RAO) ventric...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(94)90201-1

    authors: Schoephoerster RT,Silva CL,Ray G

    更新日期:1994-02-01 00:00:00

  • Simulation of mechanical behavior of temperature-responsive braided stents made of shape memory polyurethanes.

    abstract::Polymeric stents can be considered as an alternative to metallic stents thanks to their lessened incidence of restenosis and controlled deployment. The purpose of this study was to investigate the feasibility of developing a temperature-responsive braided stent using shape memory polyurethane (SMPU) through finite ele...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.10.032

    authors: Kim JH,Kang TJ,Yu WR

    更新日期:2010-03-03 00:00:00

  • Transient body sway characteristics during single-leg quiet stance in ballet dancers and young adults.

    abstract::This study explored transient characteristics of body sway during single-leg quiet stance in young ballet dancers (n = 41) and young healthy adults (n = 58). We compared the groups in terms of center of pressure (CoP) parameters (CoP velocity and amplitude, averaged across the duration of the 30-s trial), and the tran...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.110195

    authors: Kozinc Ž,Šarabon N

    更新日期:2021-01-22 00:00:00

  • Effects of intervertebral disc lesion and multifidus muscle resection on the structure of the lumbar intervertebral discs and paraspinal musculature of the rat.

    abstract::The aim of this study was to investigate whether elimination of multifidus muscle in rats causes intervertebral disc (IVD) degeneration similar to that found after IVD lesion. Data were obtained from 36 male Wistar rats randomly assigned to one of three groups: (i) IVD lesion, in which the L4/L5 IVD was stabbed; (ii) ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.01.004

    authors: Maas H,Noort W,Hodges PW,van Dieën J

    更新日期:2018-03-21 00:00:00

  • Propulsive joint powers track with sensor-derived angular velocity: A potential tool for lab-less gait retraining.

    abstract::Lower propulsive joint powers, particularly at the ankle, are often observed in older compared to young adults. Interventions to increase joint powers often require labs with motion capture and force treadmill technology. Translating these interventions out of the lab requires identifying portable measures that track ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109821

    authors: Hafer JF,Zernicke RF

    更新日期:2020-06-09 00:00:00

  • A critical comparison of different residence time measures in aneurysms.

    abstract::Flow stagnation and residence time (RT) are important features of diseased arterial flows that influence biochemical transport processes and thrombosis. RT calculation methods are classified into Eulerian and Lagrangian approaches where several measures have been proposed to quantify RT. Each of these methods has a di...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.03.028

    authors: Reza MMS,Arzani A

    更新日期:2019-05-09 00:00:00

  • The ground reaction force thresholds for detecting postural stability in participants with and without flat foot.

    abstract::Foot mobility commonly contributes to injury via altered motion of the lower extremities. However, there is a lack of understanding of sensitive kinetic changes with flat foot. The purpose of this study was to investigate the threshold that best distinguishes between participants with and without flat foot. The kineti...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.11.004

    authors: Sung PS

    更新日期:2016-01-04 00:00:00

  • Biomechanical influences of pin placement and elbow angle on hinge alignment and joint distraction of bridged elbow-pin-fixator construct.

    abstract::Joint distraction and mobilization with a hinged external fixator preserves elbow stability and mobility. However, the alignment of both elbow and fixator hinges was the initial prerequisite of the arthrodiatasis technique. The main goal of this study was to numerically evaluate the kinematic influence of the device, ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.07.030

    authors: Shih KS,Lin SC,Chao CK,Lee WS,Lu TW,Hou SM

    更新日期:2010-03-03 00:00:00

  • Reducing upper airway collapse at lower continuous positive airway titration pressure.

    abstract::During respiration, upper airway (UA) collapse occurs when the forces generated from the negative UA pressures exceed the forces produced by the UA muscles; which leads to loose soft tissue at the back of the mouth. At predetermined titration pressure, the Continuous Positive Airway Pressure (CPAP) normally provides a...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.11.005

    authors: Ashaat S,Al-Jumaily AM

    更新日期:2016-12-08 00:00:00

  • Relationship between shear modulus and passive tension of the posterior shoulder capsule using ultrasound shear wave elastography: A cadaveric study.

    abstract::Although shear wave elastography (SWE) has been used to indirectly measure passive tension in muscle tissues, it is unknown whether SWE can adequately evaluate passive tension in capsule tissues. This study investigated the relationship between the shear modulus and passive tension in the posterior shoulder capsule us...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.109498

    authors: Iida N,Taniguchi K,Watanabe K,Miyamoto H,Taniguchi T,Fujimiya M,Katayose M

    更新日期:2020-01-23 00:00:00

  • Sarcomere dynamics in skeletal muscle myofibrils during isometric contractions.

    abstract::The main goal of this study was to evaluate the dynamics of sarcomeres during isometric activation of skeletal muscle myofibrils. Rabbit psoas myofibrils (n=14) were attached between a pair of cantilevers for force measurements at one side and a rigid glass needle at the other side, and their images were used for meas...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.08.011

    authors: Pavlov I,Novinger R,Rassier DE

    更新日期:2009-12-11 00:00:00

  • Functional muscle synergies constrain force production during postural tasks.

    abstract::We recently demonstrated that a set of five functional muscle synergies were sufficient to characterize both hindlimb muscle activity and active forces during automatic postural responses in cats standing at multiple postural configurations. This characterization depended critically upon the assumption that the endpoi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.09.012

    authors: McKay JL,Ting LH

    更新日期:2008-01-01 00:00:00