Abstract:
:People with a transtibial amputation have numerous secondary health conditions, including an increased prevalence of low back pain. This increased prevalence may be partially explained by altered low back biomechanics during movement. The purpose of this study was to compare trunk kinematics and L4-L5 lumbar loads in people with and without a transtibial amputation during sit-to-stand. Motion capture, ground reaction force and electromyographic data were collected from eight people with a unilateral transtibial amputation and eight people without an amputation during five self-paced sit-to-stand motions. A musculoskeletal model of the torso, lumbar spine, pelvis, lower limbs, and 294 muscles was used in a static optimization framework to quantify L4-L5 loads, low back muscle forces, and trunk kinematics. Participants with an amputation had greater peak and average L4-L5 loading in compression compared to control participants, with peak loading occurring shortly after liftoff from the chair. At the instant of peak loading, participants with an amputation had significantly greater segmental trunk lateral bending and trunk-pelvis axial rotation toward the intact side, and significantly greater segmental trunk axial rotation toward the prosthetic side compared to control participants. Participants with an amputation also had greater peak frontal plane and transverse plane segmental trunk angular velocity. The postural differences observed in people with a transtibial amputation were consistent with their ground reaction force asymmetry. The cumulative effects of the altered movement strategy used by people with an amputation may result in an increased risk for low back pain development over time.
journal_name
J Biomechjournal_title
Journal of biomechanicsauthors
Actis JA,Nolasco LA,Gates DH,Silverman AKdoi
10.1016/j.jbiomech.2017.12.030subject
Has Abstractpub_date
2018-03-01 00:00:00pages
1-9eissn
0021-9290issn
1873-2380pii
S0021-9290(17)30743-1journal_volume
69pub_type
杂志文章abstract::Low back pain (LBP) affects many individuals worldwide. The established association between LBP and spine motor control has led to the development of many control assessment techniques. To understand spine control and LBP, it is essential to know the relationship between assessment techniques. Systems identification (...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2019.109344
更新日期:2019-11-11 00:00:00
abstract::The periodontal ligament (PDL) is a critical player in the maintenance of tooth health, acting as the primary stabilizer of tooth position. Recent studies have identified two unique regions within the PDL, the 'dense collar' region and the 'furcation' region, which exhibit distinct structural and compositional differe...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2020.109996
更新日期:2020-10-09 00:00:00
abstract::This paper describes a method for adjusting biomechanics platform measures of sway for loss of balance. Area and velocity measures of sway were determined in forty-seven elderly women, in double and single leg stance, first with their eyes open, then closed. Subjects were rarely able to complete 10 s trials during sin...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(90)90025-x
更新日期:1990-01-01 00:00:00
abstract::The finite element method described in this study provides an easy method to simulate the kinetics of multibody mechanisms. It is used in order to develop a musculoskeletal model of the shoulder mechanism. Each relevant morphological structure has been represented by an appropriate element. For the shoulder mechanism ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(94)90065-5
更新日期:1994-05-01 00:00:00
abstract::The ultimate compressive strength and modulus of elasticity of femoral cortical bone from adult geese (Anser anser), were determined by sex and by quadrant by compressing small right circular cylinders which were 2.4 mm in height and 0.8 mm in diameter. The average ultimate compressive strength was 183 +/- 29 MPa. The...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(83)90108-2
更新日期:1983-01-01 00:00:00
abstract::Creep is a time-dependent viscoelastic deformation observed under a constant prolonged load. It has been indicated that progressive vertebral deformation due to creep may increase the risk of vertebral fracture in the long-term. The objective of this study was to examine the relationships of creep with trabecular arch...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2011.03.025
更新日期:2011-06-03 00:00:00
abstract::The trunk has a multi-segmental structure and is composed of the cervical, thoracic, and lumber spines and surrounding soft tissue elements; this allows flexible deformation during dynamic movements. The purpose of this study was to quantitatively assess trunk deformation during dynamic movement. Ten male subjects per...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2017.04.019
更新日期:2017-07-05 00:00:00
abstract::A finite element model of a bioprosthetic heart valve was developed to determine the influence of the stent height on leaflet stresses under various pressure loading conditions after valve closure. A nonlinear solution was used to obtain the stresses in the leaflets for stent heights of 14.6 mm, 19.0 mm and 22.0 mm re...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(86)90199-5
更新日期:1986-01-01 00:00:00
abstract::It is generally accepted that spine control and stability are relevant for the prevention and rehabilitation of low back pain (LBP). However, there are conflicting results in the literature in regards to how these variables are modified in the presence of LBP. The aims of the present work were twofold: (1) to use noxi...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2017.04.010
更新日期:2017-06-14 00:00:00
abstract::In order to support the decisions of medical experts and to develop better stent designs, the availability of a simulation tool for virtual stenting would be extremely useful. An innovative virtual stenting technique is described in this work, which is directly applicable for complex patient-specific geometries. A bas...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2012.08.047
更新日期:2013-01-04 00:00:00
abstract::Chondrocytes in articular cartilage are regularly subjected to compression and recovery due to dynamic loading of the joint. Previous studies have investigated the elastic and viscoelastic properties of chondrocytes using micropipette aspiration techniques, but in order to calculate cell properties, these studies have...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2004.11.006
更新日期:2006-01-01 00:00:00
abstract::Gelatin is a popular tissue simulant used in biomedical applications. The uniaxial compressive stress-strain response of gelatin was determined at a range of strain rates. In the quasistatic regime, gelatin strength remained relatively constant. With increase in loading rate, the compressive strength increased from 3k...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2009.10.008
更新日期:2010-02-10 00:00:00
abstract::To better protect soldiers from blast threat, that principally affect air-filled organs such a lung, it is necessary to develop an adapted injury criterion and, prior to this, to evaluate the response of a biological model against that threat. The objective of this study is to provide some robust data to quantify the ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2017.10.012
更新日期:2017-12-08 00:00:00
abstract::The treatment of choice for early mobilization of hip fracture is surgery, which traditionally employs side plates and screws or intramedullary nails. We examined the biomechanical properties of a new proximal femoral nail system. The new expandable Fixion proximal femur nailing (PFN) system, made of stainless-steel a...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2004.03.014
更新日期:2005-01-01 00:00:00
abstract::This paper presents a method for analyzing and comparing numerically Saphenous Vein Grafts (SVGs) following Coronary Artery Bypass Graft surgery (CABG). The method analyses the flow dynamics inside vein grafts with and without supporting using Venous External Scaffolding Technology (VEST). The numerical method uses pa...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2015.03.011
更新日期:2015-07-16 00:00:00
abstract::In the present study, a numerical calculation procedure based on a finite volume method was developed to simulate steady flow fields in a model of abdominal aorta with its peripheral branches. The study focused on the steady baseline flow fields and the wall shear stress (WSS) distribution as well as the localization ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/s0021-9290(02)00044-1
更新日期:2002-08-01 00:00:00
abstract::Acute injury severity, altered joint kinematics, and joint incongruity are three important mechanical factors linked to post-traumatic osteoarthritis (PTOA). Finite element analysis (FEA) was previously used to assess the influence of increased contact stress due to joint incongruity on PTOA development. While promisi...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2015.05.030
更新日期:2015-09-18 00:00:00
abstract::Shape plays an important role in determining the biomechanical response of a structure. Specimen-specific finite element (FE) models have been developed to capture the details of the shape of biological structures and predict their biomechanics. Shape, however, can vary considerably across individuals or change due to...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2009.08.036
更新日期:2010-01-19 00:00:00
abstract::In order to provide physical information supporting the clinical use of flow mapping, an in vitro model was designed to measure the velocity fields in a pulsatile hydraulic turbulent jet. We used a peak velocity ranging from 2.5 to 5.5 m.s-1, an orifice diameter ranging from 5.8 to 11.3 mm and confined the jet in a re...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(90)90367-c
更新日期:1990-01-01 00:00:00
abstract::This paper studied two different regression techniques for pelvic shape prediction, i.e., the partial least square regression (PLSR) and the principal component regression (PCR). Three different predictors such as surface landmarks, morphological parameters, or surface models of neighboring structures were used in a c...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2012.11.005
更新日期:2013-01-04 00:00:00
abstract::A sticky chain model has been proposed to describe the unfolding of spectrin network under applied mechanical loads. With the model, the response of a red blood cell (RBC) under static and cyclic shear loading has been predicted, which agrees qualitatively with relevant experimental results. ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2008.05.028
更新日期:2008-08-07 00:00:00
abstract::Musculoskeletal simulations of human movement commonly use Hill muscle models to predict muscle forces, but their sensitivity to model parameter values is not well understood. The purpose of this study was to evaluate muscle model sensitivity to perturbations in 14 Hill muscle model parameters in forward dynamic simul...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2005.06.005
更新日期:2006-01-01 00:00:00
abstract::Flexure is a major deformation mode of the aortic valve (AV) leaflet, particularly in the commissural region where the upper portion of the leaflet joins the aortic root. However, there are no existing data known on the mechanical properties of leaflet in the commissural region. To address this issue, we quantified th...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2005.10.026
更新日期:2006-01-01 00:00:00
abstract::Numerical models commonly account for elastic inhomogeneity in cortical bone using power-law scaling relationships with various measures of tissue density, but limited experimental data exists for anatomic variation in elastic anisotropy. A recent study revealed anatomic variation in the magnitude and anisotropy of el...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2011.04.009
更新日期:2011-06-03 00:00:00
abstract::Epigenetics is the regulation of gene expression (transcription) in response to changes in the cell environment through genomic modifications that largely involve the non-coding fraction of the human genome and that cannot be attributed to modification of the primary DNA sequence. Epigenetics is dominant in establishi...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2016.11.017
更新日期:2017-01-04 00:00:00
abstract::The relative motion of the brain with respect to the skull has been widely studied to investigate brain injury mechanisms under impacts, but the motion patterns are not yet thoroughly understood. This work analyzes brain motion patterns using the most recent and advanced experimental relative brain/skull motion data c...
journal_title:Journal of biomechanics
pub_type: 杂志文章,评审
doi:10.1016/j.jbiomech.2006.06.018
更新日期:2007-01-01 00:00:00
abstract::A dry-land rowing system was developed to provide the coach and/or athlete with quantitative information about the athlete's kinetics and kinematics while the athlete trains. This system consists of a Concept II rowing ergometer instrumented with a force transducer and potentiometer, four electrogoniometers attached t...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/s0021-9290(99)00139-6
更新日期:2000-02-01 00:00:00
abstract::In presence of aortic stenosis, a jet is produced downstream of the aortic valve annulus during systole. The vena contracta corresponds to the location where the cross-sectional area of the flow jet is minimal. The maximal transvalvular pressure gradient (TPG(max)) is the difference between the static pressure in the ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2005.10.013
更新日期:2006-01-01 00:00:00
abstract::The application of joint contact mechanics requires a precise configuration of the joint surfaces. B-Spline, and NURBS have been widely used to model joint surfaces, but because these formulations use a structured data set provided by a rectangular net first, then a grid, there is a limit to the accuracy of the models...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2004.01.009
更新日期:2004-10-01 00:00:00
abstract::Adverse wall shear stress (WSS) patterns are known to play a key role in the localisation, formation, and progression of intracranial aneurysms (IAs). Complex region-specific and time-varying aneurysmal WSS patterns depend both on vascular morphology as well as on variable systemic flow conditions. Computational fluid...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2016.10.005
更新日期:2016-12-08 00:00:00