Influence of the number of cycles on shear fatigue strength of resin composite bonded to enamel and dentin using dental adhesives in self-etching mode.

Abstract:

:The influence of the number of cycles on shear fatigue strength to enamel and dentin using dental adhesives in self-etch mode was investigated. A two-step self-etch adhesive and two universal adhesives were used to bond to enamel and dentin in self-etch mode. Initial shear bond strength and shear fatigue strength to enamel and dentin using the adhesive in self-etch mode were determined. Fatigue testing was used with 20 Hz frequency and cycling periods of 50,000, 100,000 and 1,000,000 cycles, or until failure occurred. For each of the cycling periods, there was no significant difference in shear fatigue strength across the cycling periods for the individual adhesives. Differences in shear fatigue strength were found between the adhesives within the cycling periods. Regardless of the adhesive used in self-etch mode for bonding to enamel or dentin, shear fatigue strength was not influenced by the number of cycles used for shear fatigue strength testing.

journal_name

Dent Mater J

journal_title

Dental materials journal

authors

Tsujimoto A,Barkmeier WW,Erickson RL,Takamizawa T,Latta MA,Miyazaki M

doi

10.4012/dmj.2017-012

subject

Has Abstract

pub_date

2018-01-30 00:00:00

pages

113-121

issue

1

eissn

0287-4547

issn

1881-1361

journal_volume

37

pub_type

杂志文章
  • Effects of a barbituric acid/CuCl2 initiator system on resin adhesion to dentin.

    abstract::The effectiveness of a barbituric acid/copper (II) chloride initiator system in dentin was examined in terms of the effects of barbituric acid structures and dentin conditioners on bond strength. Curing times and tensile bond strengths to bovine dentin were measured for PMMA/MMA resins in conjunction with initiators c...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.14.221

    authors: Suzuki A,Imai Y

    更新日期:1995-12-01 00:00:00

  • Water durability of resin bond to pure gold treated with various adhesion promoting thiirane monomers.

    abstract::Adhesion promoting monomers for precious metals, 2,3-epithiopropyl methacrylate (EP1MA), 4,5-epithiopentyl methacrylate (EP3MA), 9,10-epithiodecyl methacrylate (EP8MA), 10,11-epithioundecyl methacrylate (EP9MA), 9,10-epithiodecyl 4-vinylbenzoate (EP8VB), 2,3-epithiocyclohexyl methacrylate (EPCHMA), and 3,4-epithiobuty...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.26.29

    authors: Kadoma Y,Kojima K,Tamaki Y,Nomura Y

    更新日期:2007-01-01 00:00:00

  • Nanostructure evaluation of healthy and fluorotic dentin by atomic force microscopy before and after phosphoric acid etching.

    abstract::The aim was to characterize by atomic force microscopy (AFM) the nanostructure of human dentin surfaces affected by dental fluorosis (DF) before and after phosphoric acid etching. This study included 240 human dentin samples classified according to the severity of DF, which were divided into four groups using the Thyl...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2011-023

    authors: Zavala-Alonso V,Aguilera-Flores R,Patiño-Marin N,Martinez-Castañon GA,Anusavice KJ,Loyola-Rodriguez JP

    更新日期:2011-01-01 00:00:00

  • An ultrastructural analysis of the prototype single-step adhesive applied on enamel and dentin surfaces.

    abstract::A new type of self-etching agent, the single-step adhesive, was developed. The purpose of this study was to investigate the difference in the ultrastructural features of enamel and dentin surfaces following application of the prototype single-step adhesive (EXM618, 3M, MN, USA). Extracted caries-free human premolars w...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.23.321

    authors: Han L,Cruz E,Fukushima M,Okamoto A,Okiji T

    更新日期:2004-09-01 00:00:00

  • Impact of different surface treatments and repair material reinforcement on the flexural strength of repaired PMMA denture base material.

    abstract::This study assessed the impact of surface treatments and repair resin reinforcement with zirconium oxide nano-particles (nano-ZrO2) on flexural strength (FS) of repaired denture base. A total of 320 heat-polymerized acrylic resin specimens were prepared and sectioned creating 2-mm gap. According to repair surface trea...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2018-436

    authors: Gad MM,Rahoma A,Abualsaud R,Al-Thobity AM,Akhtar S,Helal MA,Al-Harbi FA

    更新日期:2020-06-05 00:00:00

  • Assessment of mechanical properties of WaveOne Gold Primary reciprocating instruments.

    abstract::This study aimed to evaluate cyclic fatigue resistance and bending properties and torque/force generation of WaveOne Gold (WOG) Primary in comparison with WaveOne (WO) Primary and Reciproc (RE) R25. A cyclic fatigue test revealed that the WOG Primary took significantly longer time to fracture compared with the WO Prim...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2018-203

    authors: Fangli T,Maki K,Kimura S,Nishijo M,Tokita D,Ebihara A,Okiji T

    更新日期:2019-06-01 00:00:00

  • Effects of dose of recombinant human BMP-2 on bone formation at palatal sites in young and old rats.

    abstract::This study was designed to examine the effects of dose of recombinant human BMP-2 (rhBMP-2) on bone formation at palatal sites in 10-week-old (10w) and 70-week-old (70w) rats, when combined with a polylactate-polyglycolate copolymer/gelatine sponge (PGS). New bone formation was observed at six weeks after implantation...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.26.481

    authors: Yamaji K,Kawanami M,Matsumoto A,Odajima T,Nishitani Y,Iwasaka K,Yoshimitsu K,Yoshiyama M

    更新日期:2007-07-01 00:00:00

  • Wear resistance of hybrid composite resin for crown material by the two-body sliding test.

    abstract::Comparative studies on two-body sliding wear resistance were performed between a hybrid composite resin and conventional light-curing composite veneering materials. This study investigated the wear resistance of hybrid composite resins compared with three composite resin veneering materials for 12%Au-Ag-Pd alloy, the ...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.21.225

    authors: Suese K,Kawazoe T

    更新日期:2002-09-01 00:00:00

  • Pre-treatment of radicular dentin by self-etch primer containing chlorhexidine can improve fiber post bond durability.

    abstract::We evaluated whether the pre-treatment of radicular dentin by ED Primer containing different concentrations of chlorhexidine can improve the bond durability of fiber post to radicular dentin. Experimental ED primers containing different concentrations of chlorhexidine (0%, 0.5% and 1.0%) were prepared. Thirty extracte...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2012-134

    authors: Zhou J,Yang X,Chen L,Liu X,Ma L,Tan J

    更新日期:2013-01-01 00:00:00

  • Surface analysis of dentinal caries in primary teeth using a pH-imaging microscope.

    abstract::The aim of this in vitro study was to evaluate the pH value of intact and carious dentin in primary teeth using a pH-imaging microscope (SCHEM-100, HORIBA Ltd., Kyoto, Japan). Bucco-lingual cut sections of extracted human primary teeth, which had either mild or severe dentinal caries lesions, were placed on the pH-ima...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.23.628

    authors: Nikaido T,Moriya K,Hiraishi N,Ikeda M,Kitasako Y,Foxton RM,Tagami J

    更新日期:2004-12-01 00:00:00

  • The extent of polymerization of Class II light-cured composite resin restorations; effects of incremental placement technique, exposure time and heating for resin inlays.

    abstract::The extent of polymerization of light-cured composite resins cured in relatively large class II cavities was estimated by measuring Knoop hardness on sectioned surfaces of resin restorations. The influences of the incremental placement technique, exposure time, and post-curing of resin inlay on the extent of polymeriz...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.12.159

    authors: Hirabayashi S,Hood JA,Hirasawa T

    更新日期:1993-12-01 00:00:00

  • Transformation behavior of nickel-titanium orthodontic wires under tensile load.

    abstract::This study investigated transformations of nickel-titanium wires using differential scanning calorimetry (DSC) and thermomechanical analysis (TMA) under tensile load (100 gf or 500 gf). Two nickel-titanium wires, 35°C Copper Ni-Ti and Nitinol SE, were selected. DSC analyses were performed between -90° and 100°C. Speci...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2010-196

    authors: Iijima M,Ohta M,Brantley WA,Naganishi A,Murakami T,Muguruma T,Mizoguchi I

    更新日期:2011-01-01 00:00:00

  • Fluorescence of thulium-doped translucent zirconia.

    abstract::The fluorescence and physical properties of thulium-doped zirconia were investigated. A standard grade of zirconia (TZ-3Y-E) and two translucent dental zirconia materials (Zpex and Zpex Smile) were examined. The specimens were prepared by addition of 0-1.5 wt% Tm2O3 and then sintering. When exposed to UV light, the Tm...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2017-384

    authors: Nakamura T,Okamura S,Nishida H,Usami H,Nakano Y,Wakabayashi K,Sekino T,Yatani H

    更新日期:2018-11-30 00:00:00

  • Ceramic bonding strength of Au-1.6 wt% Ti alloy.

    abstract::The aim of this investigation was to evaluate the metal-ceramic bonding of Au-1.6 wt% Ti alloy. Therefore, the coefficient of thermal expansion, modulus of elasticity, ceramic bonding strength, and hardness of Au-1.6 wt% Ti alloy were measured. The metal-ceramic interface was observed by EPMA to investigate its bondin...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.24.268

    authors: Ito M,Kikuchi M,Okuno O,Kimura K

    更新日期:2005-06-01 00:00:00

  • Flexural properties of three kinds of experimental fiber-reinforced composite posts.

    abstract::The aim of this study was to estimate the flexural properties of three kinds of experimental fiber-reinforced composite (FRC) posts and to evaluate their potential use as posts. Experimental FRC posts were fabricated with glass, aramid, and UHMWP fibers. Commercial FRC posts were used for comparison. A three-point ben...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2010-053

    authors: Kim MJ,Jung WC,Oh S,Hattori M,Yoshinari M,Kawada E,Oda Y,Bae JM

    更新日期:2011-01-01 00:00:00

  • Adhesiveness of amide monomers to tooth substrate.

    abstract::Seven types of amide monomers, methacryloyl tyrosine amide (MTYA), p-methacryloxybenzamide (p-MBA), p-methacryloxybutoxybenzamide (p-MBBA), o-methacryloxybutoxybenzamide (o-MBBA), p-methacryloxybutoxy phenylpropionamide (p-MBPPA), 3,5-dimethacryloxybenzamide (3,5-DMBA), and 3,5-di (methacryloxybutoxy)benzamide (3,5-DM...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.10.165

    authors: Hayakawa T,Horie K

    更新日期:1991-12-01 00:00:00

  • Repair bond strength of bulk-fill resin composite: Effect of different adhesive protocols.

    abstract::This study evaluated the effect of different adhesive protocols on the shear bond strength (SBS) of bulk-fill resin composite repaired with bulk-fill or conventional composite. Cylindrical bulk-fill resin composite specimens were prepared and allocated into groups according to the bonding strategy: no treatment, Silan...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2018-291

    authors: Cuevas-Suárez CE,Nakanishi L,Isolan CP,Ribeiro JS,Moreira AG,Piva E

    更新日期:2020-03-31 00:00:00

  • Effect of thermal misfit between different veneering ceramics and zirconia frameworks on in vitro fracture load of single crowns.

    abstract::Thermal misfit is deemed as one reason for the chipping of veneered zirconia restorations. Aim of the present study was to assess the effect of thermal misfit on the fracture load of veneered zirconia frameworks and to evaluate the applicability of a universal veneering ceramic for both zirconia and titanium framework...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.26.766

    authors: Fischer J,Stawarczyk B,Tomic M,Strub JR,Hämmerle CH

    更新日期:2007-11-01 00:00:00

  • Effect of four silane coupling agents on bonding of two resin-modified glass ionomer cements to a machinable ceramic.

    abstract::The purpose of the present study was to evaluate the effect of four silane coupling agents on the bond strength between two resin-modified glass ionomer cements and a machinable leucite glass ceramic. Ceramic specimens were ground with silicon carbide paper and cleaned with phosphoric acid. They were then conditioned ...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.26.240

    authors: Kamada K,Taira Y,Yoshida K,Atsuta M

    更新日期:2007-03-01 00:00:00

  • Effect of Cr and Cu addition on corrosion behavior of Ni-Ti alloys.

    abstract::The corrosion behavior of three Ni-Ti alloys with compositions as commercial super-elastic orthodontic wires was investigated using polished plate specimens. Corrosion resistance was estimated by potentiodynamic polarization measurement in 0.9% NaCl and 1% lactic acid solutions and analysis of released metals by atomi...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.17.31

    authors: Iijima M,Endo K,Ohno H,Mizoguchi I

    更新日期:1998-03-01 00:00:00

  • Evaluation of an articulated measuring apparatus for use in the oral cavity.

    abstract::The aim of this study was to evaluate the trial Teaching Robot for the development of a contact-type measuring apparatus for using directly in the oral cavity. A standard model was used to mimic the dentition by placing an arrangement of three bearing balls. The diameters of the balls were measured. A practical dentit...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.22.168

    authors: Maikuma Y,Usui K,Araki K,Mataki S,Kurosaki N,Furuya N

    更新日期:2003-06-01 00:00:00

  • High temperature characteristics and solidification microstructures of dental metallic materials. Part II. ADAS Type 3 gold alloy.

    abstract::Previously, high temperature properties of the silver-palladium-copper-gold alloy were investigated. In this study, the thermal expansion percentage and coefficient, and high temperature strengths of ADAS Type 3 gold alloy were investigated up to the liquidus temperature. Furthermore, microstructural and compositional...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.23.81

    authors: Nagasawa S,Yoshida T,Terashima N,Mizoguchi T,Yagasaki H,Kamijo K,Ito M,Platt JA,Oshida Y

    更新日期:2004-06-01 00:00:00

  • The hydration chemistry of ProRoot MTA.

    abstract::'Tooth-coloured' ProRoot MTA is an endodontic cement comprising an 80:20 wt% mixture of white Portland cement (WPC) and bismuth oxide. The setting reactions within this cement system are not currently well understood. Accordingly, this research monitors the early hydration chemistry of ProRoot MTA by X-ray diffraction...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2014-309

    authors: Li Q,Coleman NJ

    更新日期:2015-01-01 00:00:00

  • Influence of resin coating materials on Porphyromonas gingivalis attachment.

    abstract::Resin coating materials have been used for composite resin or provisional restoration in order to prevent plaque accumulation on their surfaces. However, it is not clear whether the coating materials influence attachment of periodontal bacteria. Therefore, we investigated the effect of resin coating materials on the a...

    journal_title:Dental materials journal

    pub_type: 杂志文章,随机对照试验

    doi:10.4012/dmj.2011-164

    authors: Kumada A,Matsuka Y,Mine A,Ono M,Uehara J,Sonoi N,Ito T,Takashiba S,Kuboki T

    更新日期:2012-02-03 00:00:00

  • Deformation properties of Ti-6A1-7Nb alloy castings for removable partial denture frameworks.

    abstract::Ti-6Al-7Nb alloy was cast into three differently designed, removable partial denture frameworks: Palatal strap (PS), Anterior-posterior bar (AP), and Horseshoe-shaped bar (HS). The vertical displacement and local strain of Ti-6Al-7Nb alloy frameworks were investigated to compare against those of Co-Cr alloy frameworks...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.23.497

    authors: Srimaneepong V,Yoneyama T,Wakabayashi N,Kobayashi E,Hanawa T,Doi H

    更新日期:2004-12-01 00:00:00

  • Effect of three metal priming agents on the bond strength of adhesive resin cement to Ag-Zn-Sn-In alloy and component metals.

    abstract::The aim of this study was to investigate the effect of three metal priming agents on the bond strength of adhesive resin cement to Silver-Zinc-Tin-Indium (Ag-Zn-Sn-In) alloy and pure Ag, Zn, Sn, and In. The specimens were air-abraded with alumina and then primed with one of three metal priming agents: V-Primer, Esteni...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2017-139

    authors: Imamura N,Kawaguchi T,Shimizu H,Takahashi Y

    更新日期:2018-03-30 00:00:00

  • A study of self-adhesive resin cements for bonding to silver-palladium-copper-gold alloy -- effect of including primer components in cement base.

    abstract::This study investigated the efficacies of adhesive resin cements (Clearfil SA Luting, Maxcem, G-CEM, RelyX Unicem Clicker, Vitremer Paste) for bonding to Ag-Pd-Cu-Au alloy not surface-pretreated with metal primer. For control, Panavia F 2.0 -developed for use with a proprietary metal primer, Alloy Primer- was tested w...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2010-093

    authors: Muraguchi K,Minami H,Minesaki Y,Suzuki S,Tanaka T

    更新日期:2011-01-01 00:00:00

  • Proximal contact tightness of class Ⅱ bulk-fill composite resin restorations: An in vitro study.

    abstract::This study investigated the effect of bulk-fill composites on proximal contact tightness (PCT) of composite restorations using different matrix systems. 150/standardized-MO-ivorine cavity preparations were divided into 5 groups; Smart Dentin Replacement (SDR), SonicFill (SF), Tetric EvoCeram Bulk-Fill (TEB), G-ænial U...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2017-279

    authors: El-Shamy H,Sonbul H,Alturkestani N,Tashkandi A,Loomans BA,Dörfer C,El-Badrawy W

    更新日期:2019-02-08 00:00:00

  • New partition technique for two-chamber pressure casting unit for titanium.

    abstract::Although titanium has been widely used in prosthetic appliances, such as cast removable partial denture frameworks, high quality castings are still difficult to obtain. This study proposes a new partition technique using a metal foil for improving castability of a two-chamber pressure casting unit. The metal foil was ...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.19.307

    authors: Watanabe K,Okawa S,Kanatani M,Nakano S,Miyakawa O,Kobayashi M

    更新日期:2000-09-01 00:00:00

  • Technique-sensitivity of contemporary adhesives.

    abstract::Besides micro-mechanical interlocking through hybrid-layer formation, self-etch adhesives may benefit from additional chemical interaction between the functional monomer and residual hydroxyapatite. One-step adhesives are commonly associated with lower bonding effectiveness, which must be attributed in part to the dis...

    journal_title:Dental materials journal

    pub_type: 杂志文章,评审

    doi:10.4012/dmj.24.1

    authors: Van Meerbeek B,Van Landuyt K,De Munck J,Hashimoto M,Peumans M,Lambrechts P,Yoshida Y,Inoue S,Suzuki K