Abstract:
PURPOSE:To evaluate the reliability indices [fixation losses, false negative response rates (FN) and false positive response rates] and threshold sensitivities obtained from glaucoma patients with a Compass perimeter and to compare the same with the Humphrey field analyzer (HFA). METHODS:In a cross-sectional study, 97 eyes of 58 subjects (64 glaucoma and 33 glaucoma suspect eyes) underwent visual field examination with Compass and HFA. Any test with a fixation losses, FN or FP of >20% was considered unreliable. Reliability indices and threshold sensitivities between the 2 instruments were compared and the agreement evaluated using Bland and Altman analysis. RESULTS:In total, 37 tests (38%) with Compass and 17 (18%) with HFA were unreliable. The number of unreliable tests due to high FN (>20%) was significantly more (P=0.005) with Compass (n=27) than HFA (n=3). The mean difference [95% limits of agreement (LoA)] in mean sensitivity between Compass and HFA in the 51 eyes with reliable Compass and HFA results was -0.7 dB (-5.6, 4.3 dB). The point-wise threshold sensitivities with Compass were lower than that with HFA in central and temporal but higher in the nasal field. The 95% LoA ranged from -8 to +5 dB at one of the central points to -20 to +20 dB at one of the peripheral points. CONCLUSIONS:The numbers of unreliable tests were higher with Compass compared with HFA. The LoA between Compass and HFA for point-wise threshold sensitivities as well as the global indices were wide, implying that the instruments cannot be used interchangeably.
journal_name
J Glaucomajournal_title
Journal of glaucomaauthors
Rao HL,Raveendran S,James V,Dasari S,Palakurthy M,Reddy HB,Pradhan ZS,Rao DA,Puttaiah NK,Devi Sdoi
10.1097/IJG.0000000000000609subject
Has Abstractpub_date
2017-03-01 00:00:00pages
292-297issue
3eissn
1057-0829issn
1536-481Xjournal_volume
26pub_type
杂志文章abstract:PURPOSE:To report a case of successful intraocular pressure (IOP) reduction after a 360-degree gonioscopy-assisted transluminal trabeculotomy (GATT) using the iTrack catheter in a patient with steroid-induced glaucoma as a result of treatment of vernal keratoconjunctivitis (VKC). MATERIALS AND METHODS:Case report. RE...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0000000000001326
更新日期:2019-10-01 00:00:00
abstract:PURPOSE:To investigate the effect of nepafenac on intraocular pressure (IOP) in primary open-angle glaucoma (POAG) patients treated with prostaglandin (PG) analogs. MATERIALS AND METHODS:This prospective clinical study included 35 patients who had been receiving latanoprost (n=12), travoprost (n=12), or bimatoprost (n...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0000000000000204
更新日期:2016-03-01 00:00:00
abstract:PURPOSE:To study the frequencies and factors associated with 4 disc patterns in primary open-angle glaucoma (POAG) identified in population-based studies: focal glaucomatous (FG type), generalized enlargement of cup (GE type), myopic glaucomatous (MG type), and senile sclerotic glaucomatous (SS type) patterns. SUBJECT...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0000000000001240
更新日期:2019-06-01 00:00:00
abstract:PURPOSE:To investigate the amount of intraocular pressure (IOP) asymmetry in a large group of ethnically diverse patients with and without glaucoma, and to delineate the risk for glaucoma which increasing amounts of IOP asymmetry confer upon the patient. PATIENTS AND METHODS:Collaborative retrospective study of 326 gl...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0b013e318237bfb8
更新日期:2013-03-01 00:00:00
abstract:PURPOSE:The Molteno implant is one of the most widely used drainage devices for the management of complicated glaucoma. Antiproliferative agents such as mitomycin-C (MMC) have markedly improved the outcome of glaucoma filtering surgery. This case control study compares the results of these two techniques in the managem...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:
更新日期:1995-04-01 00:00:00
abstract::A 56-year-old Hispanic male individual with moderate primary open-angle glaucoma on maximal tolerated topical therapy with recent visual field progression presented with excessive glare due to cataract in the right eye. The patient underwent uncomplicated phacoemulsification with supraciliary microstent implantation. ...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0000000000001407
更新日期:2020-01-01 00:00:00
abstract:SUMMARY:Subconjunctival fibrosis is one of the major causes of most bleb failures. To inhibit the wound-healing process and to achieve a better intraocular pressure (IOP) lowering effect as well as bleb formation, we performed a sclerostomy using a THC:YAG laser (thulium, holmium, and chromium-doped yttrium-aluminum-ga...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:
更新日期:1993-01-01 00:00:00
abstract:PURPOSE:To report 2-year results of deep sclerectomy (DS) with mitomycin C and the uveoscleral implant Esnoper-Clip (AJL Ophthalmics, Álava, Spain), a nonabsorbable hema implant, and the morphologic analysis of the surgical area with anterior segment optical coherence tomography (AS-OCT). MATERIALS AND METHODS:In tota...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0000000000000756
更新日期:2017-10-01 00:00:00
abstract:PURPOSE:Glaucoma drainage implantation in conjunction with Boston Type 1 Keratoprosthesis placement is a surgical option in controlling postoperative glaucoma. The purpose of this study is to report outcomes of combined pars plana vitrectomy and glaucoma drainage implantation with corneal patch graft in Boston Type 1 K...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0b013e31829e55f8
更新日期:2014-01-01 00:00:00
abstract::The most effective way to control glaucoma is by lowering intraocular pressure (IOP) in order to prevent the progression of the disease. Glaucoma drainage devices (GDDs) are surgical option reserved for refractory cases and have been designed to address known complications of conventional filtering surgery. They are, ...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0000000000001417
更新日期:2020-02-01 00:00:00
abstract:PURPOSE:Primary open-angle glaucoma is a significant health-economic burden in both the United States and Europe that is likely to increase. This study compared treatment patterns and cost among patients with primary open-angle glaucoma in these locations. METHODS:Retrospective medical chart reviews were conducted in ...
journal_title:Journal of glaucoma
pub_type: 杂志文章,多中心研究
doi:10.1097/IJG.0b013e3180575202
更新日期:2007-08-01 00:00:00
abstract:PURPOSE:Latanoprost, travoprost, and bimatoprost are prostaglandin or prostamide-type ocular hypotensive medications, all of which are effective and safe for lowering intraocular pressure (IOP). Most studies with these types of drugs have included patients mainly from European or white ethnic backgrounds; however, some...
journal_title:Journal of glaucoma
pub_type: 杂志文章,多中心研究,随机对照试验
doi:10.1097/IJG.0b013e3181c4aeac
更新日期:2010-09-01 00:00:00
abstract::Primary intraocular lymphoma can cause an elevation of intraocular pressure (IOP), resulting from infiltration of the trabecular meshwork with neoplastic lymphocytes. More rarely, therapeutic procedures can induce a highly synchronised death of tumor cells, leading to congestion of the trabecular meshwork with cell de...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0b013e31827a0875
更新日期:2014-09-01 00:00:00
abstract::Gonioscopy-assisted transluminal trabeculotomy (GATT) is a minimally invasive ab interno procedure, performed with guidance of an illuminating microcatheter device (iTrack). The pathophysiology of raised intraocular pressure (IOP) in uveitic glaucoma is commonly due to increased resistance at the trabecular meshwork-S...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0000000000001641
更新日期:2020-10-01 00:00:00
abstract::Glaucoma is a progressive optic neuropathy that is the leading cause of irreversible blindness in the world. Although methods to lower intraocular pressure are the mainstay of glaucoma therapy, there are currently no available treatment modalities targeted at neuroprotection. Erythropoietin is a hematopoietic cytokine...
journal_title:Journal of glaucoma
pub_type: 杂志文章,评审
doi:10.1097/IJG.0b013e318156a556
更新日期:2007-09-01 00:00:00
abstract:PURPOSE:The aim of this study was to compare the peripapillary vessel density between eyes with pseudoexfoliation glaucoma (PXG) and eyes with primary open-angle glaucoma (POAG). METHODS:Peripapillary vessel density in the radial peripapillary capillaries was assessed using optical coherence tomography angiography, an...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0000000000001062
更新日期:2018-11-01 00:00:00
abstract::The pressure on glaucoma services is ever-growing, and policymakers seek robust cost-effectiveness arguments in their decisions around resource allocation. The benefits of glaucoma are in preventing or delaying a future loss of vision and associated quality of life, and this expectation is quantified using a metric ca...
journal_title:Journal of glaucoma
pub_type: 杂志文章,评审
doi:10.1097/IJG.0000000000001462
更新日期:2020-04-01 00:00:00
abstract:PURPOSE:The authors identify any diurnal intraocular pressure (IOP) variation in healthy Cayo Santiago macaques, as well as Cayo Santiago macaques with normotensive and hypertensive primary open-angle glaucoma (POAG), to further evaluate their potential value as a model for human POAG. METHODS:Twenty-four monkeys (eig...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:
更新日期:1998-04-01 00:00:00
abstract::While working with a large data set of Goldmann applanation tonometry (GAT) intraocular pressure (IOP) measurements for a separate investigation, we observed that the IOP distribution favored even-numbered values. Study of this phenomenon has been limited, and this larger data set enabled inquiry that showed new insig...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0000000000001412
更新日期:2020-02-01 00:00:00
abstract:PURPOSE:To compare characteristics of functioning blebs (FBs) and nonfunctioning blebs (NFBs) with en-face spectral-domain optical coherence tomography (OCT). METHODS:We evaluated 41 blebs of 38 patients after a first-time trabeculectomy. Eyes were classified into 2 groups: FBs (22 eyes) and NFBs (19 eyes). En-face OC...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0000000000000319
更新日期:2016-05-01 00:00:00
abstract:PURPOSE:To evaluate the results of Ahmed Glaucoma Valve surgery in neovascular glaucoma and control patients. PATIENTS AND METHODS:In this retrospective comparative study, we reviewed 76 eyes of 76 patients, comparing the surgical outcomes in control patients (N=38) to matched neovascular glaucoma patients (N=38). Suc...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0b013e3181ca7f7f
更新日期:2010-12-01 00:00:00
abstract::The multifunctional protein clusterin (CLU) is a secreted glycoprotein ubiquitously expressed throughout the body, including in the eye. Its primary function is to act as an extracellular molecular chaperone, preventing the precipitation and aggregation of misfolded extracellular proteins. Clusterin is commonly identi...
journal_title:Journal of glaucoma
pub_type: 杂志文章,评审
doi:10.1097/IJG.0000000000000916
更新日期:2018-07-01 00:00:00
abstract:PURPOSE:To evaluate whether postural changes of intraocular pressure (IOP) are associated with visual field damage by comparing both eyes of patients with previously untreated normal-tension glaucoma (NTG). PATIENTS AND METHODS:Forty eyes of 20 patients newly diagnosed as bilateral NTG were studied. IOP was measured i...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0b013e3181a98f30
更新日期:2010-03-01 00:00:00
abstract:PURPOSE:To compare the difference between 2 methods of measuring the intraocular pressure (IOP), namely, Goldmann applanation tonometry (GAT) and dynamic contour tonometry (DCT) and to study the relationship with the corneal parameters in patients with no glaucoma signs. METHODS:One hundred and eighteen eyes of 118 he...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0b013e31816224bd
更新日期:2008-09-01 00:00:00
abstract:PURPOSE:To describe a simple method and outcomes of remodeling dysesthetic, oversized filtering blebs. PATIENTS AND METHODS:Retrospective chart review of the initial consecutive patients who had undergone "bleb window"-pexy (BWP) over a 1-year period. Patients with symptomatic, oversized, and dysmorphic blebs that did...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0b013e3181815a06
更新日期:2009-09-01 00:00:00
abstract:PURPOSE:To evaluate the effect of a latanoprost/timolol fixed combination (LTFC) versus a latanoprost and timolol gel-forming solution unfixed combination (LTuFC) on daytime intraocular pressure (IOP) levels and fluctuations. METHODS:This was an 8-week, randomized, parallel-group study. Ninety eyes of 90 patients diag...
journal_title:Journal of glaucoma
pub_type: 杂志文章,随机对照试验
doi:10.1097/IJG.0000000000000170
更新日期:2016-02-01 00:00:00
abstract:PURPOSE:The purpose of the study was to compare radial peripapillary capillary (RPC) density between normal subjects and patients with early primary open-angle glaucoma (POAG) using optical coherence tomography angiography (OCT-A). MATERIALS AND METHODS:A total of 24 patients with early POAG and age-matched 52 normal ...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0000000000000649
更新日期:2017-05-01 00:00:00
abstract::The in vivo response to laser trabeculoplasty (LTP) was evaluated by measuring the incorporation of thymidine into DNA in the nuclei of trabecular meshwork cells. incorporation into DNA was analyzed by light microscopic autoradiography and by scintillation counting of trabecular extracts. Sixteen cats received argon L...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:
更新日期:1994-04-01 00:00:00
abstract:AIMS:To compare the retinal nerve fiber layer thickness (RNFLT) parameters obtained with newly introduced GDx with enhanced corneal compensation (ECC) and those with GDx with variable corneal compensation (VCC) and to evaluate their reproducibility and the correspondence with visual field damage (VFD) in total or secto...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0b013e318133fb47
更新日期:2008-01-01 00:00:00
abstract:PURPOSE:Lasers have been used to treat dysfunctional blebs, but the laser remodeling of blebs that dissect into the palpebral fissure has not been reported. We describe the unique use of krypton green laser to treat dissected blebs and discuss treatment outcomes. PATIENTS AND METHODS:Retrospective review of consecutiv...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/00061198-200604000-00013
更新日期:2006-04-01 00:00:00