Abstract:
PURPOSE:Glaucoma drainage implantation in conjunction with Boston Type 1 Keratoprosthesis placement is a surgical option in controlling postoperative glaucoma. The purpose of this study is to report outcomes of combined pars plana vitrectomy and glaucoma drainage implantation with corneal patch graft in Boston Type 1 Keratoprosthesis patients. PATIENTS AND METHODS:A retrospective review of patients who underwent pars plana glaucoma drainage implantation in combination with Boston Type 1 Keratoprosthesis was performed. Preoperative and postoperative parameters collected and analyzed included: visual acuity, intraocular pressure, number of glaucoma medications to achieve intraocular pressure control, bandage contact lens fit, and postoperative complications. RESULTS:Twenty eyes of 20 patients were identified; 95% had preoperative diagnosis of glaucoma, utilizing on an average 2.5 medications with an average intraocular pressure of 19.8 mm Hg (±6.3 mm Hg; range, 9 to 32.8 mm Hg). After placement of the pars plana glaucoma drainage implant, an average intraocular pressure of 19 mm Hg (±7.0 mm Hg; range, 8 to 30 mm Hg) by scleral pneumotonometry was achieved and 85% were deemed to have normal pressures by digital palpation. An average of 2.1 intraocular pressure-lowering medications were required on last follow-up. Average follow-up was 31.6 months (±17.4 mo; range, 12.3 to 71.6 mo). Two eyes required glaucoma drainage implant explantation: one eye due to endophthalmitis from a nonhealing corneal ulcer and the other eye due to corneal melt. None of our patients experienced conjunctival erosion over a pars plana positioned glaucoma drainage implant or tube. CONCLUSIONS:For the long-term management of glaucoma in keratoprosthesis patients, a posteriorly placed pars plana glaucoma drainage implant with corneal patch graft in conjunction with keratoprosthesis has a low risk of erosion and postoperative complications.
journal_name
J Glaucomajournal_title
Journal of glaucomaauthors
Huh ES,Aref AA,Vajaranant TS,de la Cruz J,Chau FY,Cortina MSdoi
10.1097/IJG.0b013e31829e55f8subject
Has Abstractpub_date
2014-01-01 00:00:00pages
e39-44issue
1eissn
1057-0829issn
1536-481Xpii
00061198-201401000-00020journal_volume
23pub_type
杂志文章abstract:PURPOSE:To evaluate the diagnostic ability of macular parameters and peripapillary retinal nerve fiber layer (RNFL) parameters for early glaucoma using spectral domain optical coherence tomography (SD-OCT). MATERIALS AND METHODS:One eye from 32 early glaucoma patients (including preperimetric glaucoma) and 32 normal p...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0b013e3181e079ed
更新日期:2011-04-01 00:00:00
abstract:PRECIS:In a cohort study of 120,307 participants with 25+ years of follow-up, a history of nonmelanoma skin cancer (NMSC) was associated with a 40% higher exfoliation glaucoma (XFG) risk. PURPOSE:The purpose of this study was to evaluate the relationship between NMSC (a marker of ultraviolet radiation exposure) and XF...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0000000000001496
更新日期:2020-06-01 00:00:00
abstract::The lamina cribrosa (LC) is a multilayered, collagenous, sieve-like structure at the deep optic nerve head, and is presumed to be the primary site of axonal injury. According to biomechanical theory, intraocular pressure-induced posterior deformation of the LC causes blockage of axonal transport and alters the ocular ...
journal_title:Journal of glaucoma
pub_type: 杂志文章,评审
doi:10.1097/IJG.0000000000000728
更新日期:2017-09-01 00:00:00
abstract:PURPOSE:Management of a case of glaucoma secondary to an iris metastasis is reported. RESULTS:A 31-year-old woman developed glaucoma secondary to a metastatic tumor to the iris. Anti-glaucoma medication failed to control the increase in intraocular pressure (IOP). However, diode laser cyclophotocoagulation controlled ...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:
更新日期:1998-10-01 00:00:00
abstract:PURPOSE OF THE STUDY:The purpose of the study was to evaluate the long-term effectiveness and safety profile of Baerveldt glaucoma implant (BGI) in patients with refractory glaucoma operated using a modified technique to avoid postoperative complications. PATIENTS AND METHODS:A total of 160 eyes from 147 glaucomatous ...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0000000000000488
更新日期:2016-12-01 00:00:00
abstract:PRCIS:Use of toric intraocular lenses is a reasonable option for better visual outcomes when a combined minimally invasive glaucoma surgery (MIGS) and cataract surgery is performed in eyes with corneal astigmatism. PURPOSE:To assess the efficacy of toric intraocular lenses (IOLs) in combined cataract and MIGS, visual ...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0000000000001705
更新日期:2021-01-01 00:00:00
abstract:PURPOSE:To report the safety and the effectiveness of deep sclerectomy (DS) with a new nonabsorbable uveoscleral hema implant (Esnoper-Clip) designed to increase trabecular and uveoscleral outflow and to achieve higher intrascleral blebs. MATERIALS AND METHODS:Twenty-seven eyes of 27 patients with open-angle glaucoma,...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0000000000000253
更新日期:2015-08-01 00:00:00
abstract:PURPOSE:To evaluate morphological features of filtering blebs after trabeculectomy with limbus-based versus fornix-based conjunctival flaps (LBCF and FBCF, respectively) using in vivo confocal microscopy (IVCM) and ultrasound biomicroscopy (UBM). PATIENTS AND METHODS:Seventy-five eyes of 62 patients with glaucoma were...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0b013e3182120a08
更新日期:2012-08-01 00:00:00
abstract:PURPOSE:To describe the Stratus optical coherence tomography (OCT) retinal nerve fiber layer (RNFL) thickness profile of dominant optic atrophy (DOA), to differentiate it from that of glaucoma. METHODS:RNFL thickness was measured using Stratus OCT in 32 eyes of 16 DOA patients. RESULTS:The temporal-most clock hour me...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0b013e31804d23aa
更新日期:2007-12-01 00:00:00
abstract:PURPOSE:To evaluate an alternate method of covering the subconjunctival portion of the tube in aqueous shunt surgery. Evidence of tube erosion, graft-related infection, graft melting, or other associated intraocular complications were evaluated. METHODS:A retrospective study of 16 patients (17 eyes) who underwent tube...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:
更新日期:1999-10-01 00:00:00
abstract:PURPOSE:To report the histopathologic and immunohistochemical findings from the iridectomy specimen of a patient with acquired unilateral iris heterochromia due to latanoprost. PATIENT AND METHODS:A 45-year-old woman with open-angle glaucoma and unilateral iris heterochromia was evaluated for uncontrolled intraocular ...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/00061198-200110000-00009
更新日期:2001-10-01 00:00:00
abstract:PURPOSE:To determine whether the bacterial and floral patterns on the bleb surface are affected by the season in eyes that had undergone trabeculectomy with adjunctive mitomycin C. PATIENTS AND METHODS:Forty-four glaucoma patients who had an avascular or a hypovascular cystic filtering bleb were studied. Swabs of the ...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0000000000000305
更新日期:2016-05-01 00:00:00
abstract:PURPOSE:To evaluate the efficacy of CO2 laser-assisted sclerectomy surgery (CLASS) in primary and pseudoexfoliative open-angle glaucoma. MATERIALS AND METHODS:Patients for primary filtration surgery underwent CLASS with a CO2 laser system (OT-134-IOPtiMate, IOPtima Ltd., Ramat Gan, Israel). This self-controlled system...
journal_title:Journal of glaucoma
pub_type: 临床试验,杂志文章,多中心研究
doi:10.1097/IJG.0b013e3181f7b14f
更新日期:2012-03-01 00:00:00
abstract:PURPOSE:To compare the abilities of standard automated perimetry (SAP) and spectral-domain optical coherence tomography (SDOCT) in diagnosing eyes with glaucomatous optic neuropathy (GON). METHODS:In a cross-sectional study, 280 eyes of 175 subjects referred to tertiary eye care center by general ophthalmologists for ...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0000000000000048
更新日期:2015-06-01 00:00:00
abstract:PURPOSE:The purpose of the study was to evaluate the tolerability and functionality of a wireless ocular telemetry sensor in African American patients with glaucoma. MATERIALS AND METHODS:In this prospective, observational cohort study, 20 African American patients with primary open angle glaucoma (POAG) were evaluate...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0000000000001141
更新日期:2019-02-01 00:00:00
abstract:PURPOSE:To examine the relationship between retinal ganglion cell function measured using pattern electroretinogram optimized for glaucoma screening (PERGLA), retinal nerve fiber layer (RNFL) thickness, and optic nerve head topography. METHODS:Twenty-nine normal, 28 glaucoma, and 37 glaucoma suspect volunteers were en...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0b013e31819afb5c
更新日期:2009-10-01 00:00:00
abstract:PURPOSE:To discuss a case in which melanocytoma of the ciliary body presented with widespread pigment dispersion and elevated intraocular pressure (IOP). METHODS:A 64-year old woman presented with increased IOP and persistent anterior segment inflammation in her right eye. She had undergone a trabeculectomy for uncont...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:
更新日期:1999-04-01 00:00:00
abstract::Treatment with noncardioselective beta-adrenoceptor antagonists (e.g., 0.5% timolol or 0.5% levobunolol) is standard practice for lowering elevated intraocular pressure (IOP). However, because there are risks and side effects associated with the use of these agents, a lower, yet still effective, dose may be preferred....
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/00061198-199201040-00005
更新日期:1992-01-01 00:00:00
abstract:PURPOSE:To evaluate the effects of flunarizine, a nonselective calcium channel blocker, on intraocular pressure (IOP) in monkeys with laser-induced unilateral glaucoma and on aqueous humor dynamics in normal monkeys. METHODS:The IOP was measured before and hourly for 6 hours after single-dose administration of 0.5%, 1...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0b013e318133a845
更新日期:2008-01-01 00:00:00
abstract:PURPOSE:To investigate the frequency of choroidal microvasculature dropout (CMvD) in healthy myopic eyes in comparison with that of myopic open-angle glaucoma (OAG) eyes and determine whether myopia is independently associated with CMvD. PATIENTS AND METHODS:Choroidal layer microvasculature images were obtained using ...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0000000000000859
更新日期:2018-02-01 00:00:00
abstract::The pressure on glaucoma services is ever-growing, and policymakers seek robust cost-effectiveness arguments in their decisions around resource allocation. The benefits of glaucoma are in preventing or delaying a future loss of vision and associated quality of life, and this expectation is quantified using a metric ca...
journal_title:Journal of glaucoma
pub_type: 杂志文章,评审
doi:10.1097/IJG.0000000000001462
更新日期:2020-04-01 00:00:00
abstract::We report a case of tube obstruction of a non valved glaucoma drainage device (Aurolab Aqueous Drainage Implant; AADI) with a dislocated Soemmering's ring leading to a postoperative intraocular pressure (IOP) spike after an initial IOP reduction. A 24 year old male with bilateral aphakia, bilateral secondary glaucoma ...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0000000000001760
更新日期:2020-12-17 00:00:00
abstract:PURPOSE:To investigate the effects of topical instillation of 0.5% tranilast eye drops on intraocular pressure (IOP) and bleb formation after glaucoma filtering surgery. PATIENTS AND METHODS:This was a prospective, randomized, double-masked, and controlled clinical trial. A total of 52 eyes of 52 patients were randoml...
journal_title:Journal of glaucoma
pub_type: 临床试验,杂志文章,随机对照试验
doi:10.1097/00061198-200204000-00008
更新日期:2002-04-01 00:00:00
abstract::We report a case of acute angle closure with significantly elevated intraocular pressure 9 hours after implantation of a phakic intraocular lens for high myopia. ...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0000000000001533
更新日期:2020-07-01 00:00:00
abstract:PURPOSE:The purpose of the study was to investigate the effects of myopic optic disc tilt and rotation on peripapillary retinal nerve fiber layer (RNFL) thickness characteristics measured by Cirrus HD spectral-domain optical coherence tomography (Cirrus HD OCT). METHODS:A total of 93 right eyes from 93 healthy young m...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0b013e3182182567
更新日期:2012-08-01 00:00:00
abstract:PURPOSE:To describe a surgical technique to improve visualization and surgical access for trabeculectomy and implantation of aqueous drainage devices. MATERIALS AND METHODS:After the corneal traction suture (6-0 polygalactin; S-29 needle) is placed, a second suture is passed through Tenon's capsule alone, either at th...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/00061198-200212000-00014
更新日期:2002-12-01 00:00:00
abstract:PURPOSE:To compare the surgical outcomes between phaco-viscocanalostomy and phaco-trabeculotomy in open-angle glaucoma. PATIENTS AND METHODS:In a nonrandomized, retrospective clinical study, 110 eyes underwent phaco-viscocanalostomy (VCS group), and 110 eyes underwent phaco-trabeculotomy (LOT group). The mean follow-u...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/01.ijg.0000212265.96864.77
更新日期:2006-10-01 00:00:00
abstract:PURPOSE:To determine if treatment with prostaglandin (PG) analogues affects keratocyte density as an indirect measure of extracellular matrix in the corneal stroma. PATIENTS AND METHODS:In this case control study, 129 eyes from 68 patients were examined: 52 eyes had only PG analogue therapy for at least 3 years, 37 ey...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0b013e3181ca7c7a
更新日期:2010-12-01 00:00:00
abstract:PURPOSE:This randomized, masked, prospective study was conducted to compare the outcome of filtering surgery using doses of 0.2 mg/cc or 0.4 mg/cc of mitomycin C (MMC) in eyes that were at higher risk from previous conjunctival incisional surgery. METHODS:Eyes of 50 consecutive patients with primary open-angle, pseudo...
journal_title:Journal of glaucoma
pub_type: 临床试验,杂志文章,随机对照试验
doi:
更新日期:1999-06-01 00:00:00
abstract:PRECIS:As the only microinvasive glaucoma surgery (MIGS) with a reusable component, the cost per procedure of endoscopic cyclophotocoagulation (ECP) diminishes with each successive use. We present a cost comparison of ECP with other MIGS devices, based on our clinical practice. PURPOSE:ECP delivers diode laser via a r...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0000000000001245
更新日期:2019-06-01 00:00:00