Evaluation of macular thickness and peripapillary retinal nerve fiber layer thickness for detection of early glaucoma using spectral domain optical coherence tomography.

Abstract:

PURPOSE:To evaluate the diagnostic ability of macular parameters and peripapillary retinal nerve fiber layer (RNFL) parameters for early glaucoma using spectral domain optical coherence tomography (SD-OCT). MATERIALS AND METHODS:One eye from 32 early glaucoma patients (including preperimetric glaucoma) and 32 normal participants underwent macular scans and peripapillary RNFL scans with SD-OCT 3 times on the same day. The discrimination power of each parameter to detect early glaucoma was determined by areas under receiver operating characteristics curve (AROC) and sensitivity at fixed specificity. Correlation of OCT data with visual field defects was evaluated by linear regression analysis. Reproducibility was also evaluated. RESULTS:Significant differences between early glaucoma and normal participants were found for all parameters except fovea in macular scans and in the superior and inferior quadrants, at 12, 3, 6, 7, 11 o'clock, and average RNFL thickness in RNFL scans. The best parameters based on AROC and sensitivity at a specificity of >90% were temporal outer macula thickness (AROC, 0.79; sensitivity, 63%) in macular parameters and inferior quadrant (AROC, 0.82; sensitivity, 53%) in RNFL parameters. The highest correlation with mean deviation was found in inferior inner macular volume (r=0.50, P<0.001). The mean intraclass correlation coefficient was 0.96 in macular scans and 0.84 in RNFL scans. Test-retest variability ranged from 2.3 to 10.1 μm in macular thickness, 0 to 0.06 mm in macular volume, and 5.8 to 18.9 μm in RNFL thickness. CONCLUSION:For the diagnosis of early glaucoma by SD-OCT, macular parameters had high discriminating power and high reproducibility comparable with peripapillary RNFL parameters.

journal_name

J Glaucoma

journal_title

Journal of glaucoma

authors

Nakatani Y,Higashide T,Ohkubo S,Takeda H,Sugiyama K

doi

10.1097/IJG.0b013e3181e079ed

subject

Has Abstract

pub_date

2011-04-01 00:00:00

pages

252-9

issue

4

eissn

1057-0829

issn

1536-481X

journal_volume

20

pub_type

杂志文章
  • Prevalence and correlates of self-reported nonadherence with eye drop treatment: the Belgian Compliance Study in Ophthalmology (BCSO).

    abstract:PURPOSE:This study aimed to investigate (1) the prevalence of nonadherence with eye drop treatment; (2) selected correlates of nonadherence at the patient and health-care organization level; and (3) the diagnostic value of the ophthalmologists' ratings, using patients' self-reports as standard. METHODS:This cross-sect...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章,多中心研究

    doi:10.1097/IJG.0b013e3181f7b10e

    authors: Vandenbroeck S,De Geest S,Dobbels F,Fieuws S,Stalmans I,Zeyen T

    更新日期:2011-09-01 00:00:00

  • Near and Distance Stereoacuity in Patients With Primary Open-angle Glaucoma.

    abstract:PURPOSE:To compare near and distance stereoacuity between patients with primary open-angle glaucoma (POAG) and a control group, and to analyze the associations between stereoacuity and POAG severity. METHODS:This cross-sectional study compared near and distance stereoacuity between the POAG and control groups. The dat...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000000963

    authors: Park CK,Kim DW,Lee CK

    更新日期:2018-06-01 00:00:00

  • Progression of Parapapillary Choroidal Microvascular Dropout After Disc Hemorrhage in Glaucoma Patients: 2 Case Reports.

    abstract:PURPOSE:Microvasculature dropout (MvD) is a novel finding seen in optical coherence tomography angiography (OCTA), which is characterized by a localized dehiscence of the choriocapillaris in the parapapillary atrophy area. Disc hemorrhage (DH) is an important factor often associated with the development and especially ...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000001688

    authors: Lee JS,Lee WJ,Lim HW,Seong M

    更新日期:2021-01-01 00:00:00

  • Episcleral Venous Outflow: A Potential Outcome Marker for iStent Surgery.

    abstract:PURPOSE:(1) To propose the use of episcleral venous outflow (EVO) as an outcome marker of iStent surgery, and an EVO grading scale. (2) To determine the association of EVO with: (a) postoperative intraocular pressure (IOP) and medication burden; (b) iStent patency status. PATIENTS AND METHODS:Retrospective cohort stud...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000000799

    authors: Bostan C,Harasymowycz P

    更新日期:2017-12-01 00:00:00

  • Technique for removal of malpositioned Ex-PRESS glaucoma device.

    abstract:PURPOSE:To report a simple technique for removal of malpositioned Ex-PRESS miniature glaucoma filtration device. PATIENT AND METHODS:A patient who underwent removal of a malpositioned Ex-PRESS shunt from the right eye with wound revision. RESULTS:Description of step-by-step technique for removal of the Ex-PRESS shunt...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0b013e31827b1540

    authors: Khouri AS,Khan MN,Fechtner RD,Vold SD

    更新日期:2014-09-01 00:00:00

  • Corneal thickness in congenital glaucoma.

    abstract:PURPOSE:To compare central corneal thickness between eyes with congenital glaucoma and normal controls and to correlate this parameter with corneal diameter and axial length. METHODS:Eyes of consecutive children with congenital glaucoma with previous glaucoma surgery and eyes of children with inadequacy of lacrimal dr...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/00061198-200406000-00002

    authors: Henriques MJ,Vessani RM,Reis FA,de Almeida GV,Betinjane AJ,Susanna R Jr

    更新日期:2004-06-01 00:00:00

  • The Association Between Macula and ONH Optical Coherence Tomography Angiography (OCT-A) Vessel Densities in Glaucoma, Glaucoma Suspect, and Healthy Eyes.

    abstract:PURPOSE:To evaluate strength of associations between optical coherence tomography (OCT)-angiography vessel density (VD) measurements in the macula and peripapillary region of the optic nerve head (ONH) with standard structural OCT thickness measures. MATERIALS AND METHODS:This cross-sectional study included 333 eyes o...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000000862

    authors: Manalastas PIC,Zangwill LM,Daga FB,Christopher MA,Saunders LJ,Shoji T,Akagi T,Penteado RC,Yarmohammadi A,Suh MH,Medeiros FA,Weinreb RN

    更新日期:2018-03-01 00:00:00

  • Progressive High Hypermetropic Shift as a Refractive Surprise Following Glaucoma Filtration Surgery in a Phakic Child With Early-Onset Childhood Glaucoma Associated With Axenfeld-Rieger Anomaly.

    abstract:PURPOSE:We report a case of progressive high hypermetropia following glaucoma filtration surgery in a child with Axenfeld-Rieger syndrome and congenital glaucoma. METHODS/RESULTS:We report a case of a 4-day-old female child presented as a case of Axenfeld-Rieger anomaly with secondary glaucoma in both eyes (OU), who u...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000001283

    authors: Kumar P,Senthil S

    更新日期:2019-08-01 00:00:00

  • Cohort Study of Nonmelanoma Skin Cancer and the Risk of Exfoliation Glaucoma.

    abstract:PRECIS:In a cohort study of 120,307 participants with 25+ years of follow-up, a history of nonmelanoma skin cancer (NMSC) was associated with a 40% higher exfoliation glaucoma (XFG) risk. PURPOSE:The purpose of this study was to evaluate the relationship between NMSC (a marker of ultraviolet radiation exposure) and XF...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000001496

    authors: Kang JH,VoPham T,Laden F,Rosner BA,Wirostko B,Ritch R,Wiggs JL,Qureshi A,Nan H,Pasquale LR

    更新日期:2020-06-01 00:00:00

  • Relationship between pattern electroretinogram, standard automated perimetry, and optic nerve structural assessments.

    abstract:PURPOSE:To examine the relationship between retinal ganglion cell function measured using pattern electroretinogram optimized for glaucoma screening (PERGLA), retinal nerve fiber layer (RNFL) thickness, and optic nerve head topography. METHODS:Twenty-nine normal, 28 glaucoma, and 37 glaucoma suspect volunteers were en...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0b013e31819afb5c

    authors: Sehi M,Pinzon-Plazas M,Feuer WJ,Greenfield DS

    更新日期:2009-10-01 00:00:00

  • Three-Year Follow-up of a Novel Aqueous Humor MicroShunt.

    abstract:AIMS:An observational study to determine the safety and efficacy of filtering surgery employing a microlumen aqueous drainage device (InnFocus MicroShunt), used intraoperatively with Mitomycin C, implanted alone or in combination with phacoemulsification. MATERIALS AND METHODS:Single-site, prospective, nonrandomized s...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000000368

    authors: Batlle JF,Fantes F,Riss I,Pinchuk L,Alburquerque R,Kato YP,Arrieta E,Peralta AC,Palmberg P,Parrish RK 2nd,Weber BA,Parel JM

    更新日期:2016-02-01 00:00:00

  • Ahmed glaucoma valve surgical outcomes in eyes with and without silicone oil endotamponade.

    abstract:PURPOSE:To compare the results of Ahmed glaucoma valve (AGV) implantation in eyes containing silicone oil to those without silicone oil. METHODS:This was a multicenter, retrospective, comparative study of 94 eyes in 94 patients with mean follow-up of 2 years, comparing surgical outcomes in eyes with silicone oil (N=47...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0b013e318182ede3

    authors: Ishida K,Ahmed II,Netland PA

    更新日期:2009-04-01 00:00:00

  • Clinical Implications of In Vivo Lamina Cribrosa Imaging in Glaucoma.

    abstract::The lamina cribrosa (LC) is a multilayered, collagenous, sieve-like structure at the deep optic nerve head, and is presumed to be the primary site of axonal injury. According to biomechanical theory, intraocular pressure-induced posterior deformation of the LC causes blockage of axonal transport and alters the ocular ...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章,评审

    doi:10.1097/IJG.0000000000000728

    authors: Kim YW,Jeoung JW,Kim YK,Park KH

    更新日期:2017-09-01 00:00:00

  • Evaluation of prostaglandin analogue effects on corneal keratocyte density using scanning laser confocal microscopy.

    abstract:PURPOSE:To determine if treatment with prostaglandin (PG) analogues affects keratocyte density as an indirect measure of extracellular matrix in the corneal stroma. PATIENTS AND METHODS:In this case control study, 129 eyes from 68 patients were examined: 52 eyes had only PG analogue therapy for at least 3 years, 37 ey...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0b013e3181ca7c7a

    authors: Bergonzi C,Giani A,Blini M,Marchi S,Luccarelli S,Staurenghi G

    更新日期:2010-12-01 00:00:00

  • Outcomes of pars plana glaucoma drainage implant in Boston type 1 keratoprosthesis surgery.

    abstract:PURPOSE:Glaucoma drainage implantation in conjunction with Boston Type 1 Keratoprosthesis placement is a surgical option in controlling postoperative glaucoma. The purpose of this study is to report outcomes of combined pars plana vitrectomy and glaucoma drainage implantation with corneal patch graft in Boston Type 1 K...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0b013e31829e55f8

    authors: Huh ES,Aref AA,Vajaranant TS,de la Cruz J,Chau FY,Cortina MS

    更新日期:2014-01-01 00:00:00

  • The Ahmed Glaucoma Valve in patients with and without neovascular glaucoma.

    abstract:PURPOSE:To evaluate the results of Ahmed Glaucoma Valve surgery in neovascular glaucoma and control patients. PATIENTS AND METHODS:In this retrospective comparative study, we reviewed 76 eyes of 76 patients, comparing the surgical outcomes in control patients (N=38) to matched neovascular glaucoma patients (N=38). Suc...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0b013e3181ca7f7f

    authors: Netland PA,Ishida K,Boyle JW

    更新日期:2010-12-01 00:00:00

  • Long-term results of Ahmed glaucoma valve in association with intravitreal bevacizumab in neovascular glaucoma.

    abstract:PURPOSE:Evaluate the long-term results of the Ahmed glaucoma valve (AGV) surgery in association with bevacizumab (Avastin) in neovascular glaucoma (NVG) patients. DESIGN AND METHODS:This retrospective institutional study reviewed 39 eyes of 34 patients with NVG who underwent AGV implantation. The intravitreal bevacizu...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000000234

    authors: Sahyoun M,Azar G,Khoueir Z,Antoun J,Kourie H,Nehme J,Jalkh A

    更新日期:2015-06-01 00:00:00

  • Fourier analysis of nerve fiber layer measurements from scanning laser polarimetry in glaucoma: emphasizing shape characteristics of the 'double-hump' pattern.

    abstract:PURPOSE:The pattern of the distribution of nerve fiber layer (NFL) thickness values across the retina may provide an early anatomic indication of glaucomatous disruption. We developed a method of analyzing polarimetry measurements that emphasizes the shape of the pattern of NFL thickness values. Sensitivity and specifi...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/00061198-200012000-00005

    authors: Essock EA,Sinai MJ,Fechtner RD,Srinivasan N,Bryant FD

    更新日期:2000-12-01 00:00:00

  • Changes in retinal nerve fiber layer thickness after optic disc hemorrhage in glaucomatous eyes.

    abstract:PURPOSE:The aim of this study was to investigate the changes in longitudinal retinal nerve fiber layer thickness (RNFLT) as determined by spectral-domain optical coherence tomography (OCT) after optic disc hemorrhage (DH) in glaucomatous eyes. METHODS:A total of 65 eyes with unilateral DH and 65 contralateral eyes wit...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000000083

    authors: Hwang YH,Kim YY,Kim HK,Sohn YH

    更新日期:2014-10-01 00:00:00

  • The effect of laser iridotomy on the anterior segment anatomy of patients with plateau iris configuration.

    abstract:PURPOSE:To determine if laser iridotomy altered the anterior segment anatomy of patients with plateau iris configuration. METHODS:Twenty eyes of 9 female and 1 male patients were imaged using an ultrasound biomicroscope within 19 weeks before and 52 weeks after laser iridotomy. Measurements obtained included the anter...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/01.ijg.0000151687.96785.03

    authors: Polikoff LA,Chanis RA,Toor A,Ramos-Esteban JC,Fahim MM,Gagliuso DJ,Serle JB

    更新日期:2005-04-01 00:00:00

  • Relationship Between OCT Angiography Temporal Peripapillary Vessel-Density and Octopus Perimeter Paracentral Cluster Mean Defect.

    abstract:PURPOSE OF THE STUDY:The purpose of the study was to investigate the relationship between optical coherence tomography angiography angioflow vessel-density (PAFD) measured in the retinal nerve fiber layer in the temporal peripapillary sector and the average of the spatially corresponding superior and inferior paracentr...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000000630

    authors: Holló G

    更新日期:2017-05-01 00:00:00

  • The Clinical Interpretation of Changes in Intraocular Pressure Measurements Using Goldmann Applanation Tonometry: A Review.

    abstract:PURPOSE:The interpretation of changes in serial intraocular pressure (IOP) measurements are critical in the diagnosis and management of glaucoma. Differentiating true change from test-retest variability (TRV) in IOP measurements using Goldmann applanation tonometry (IOPG) is essential when reviewing these measurements....

    journal_title:Journal of glaucoma

    pub_type: 杂志文章,评审

    doi:10.1097/IJG.0000000000001144

    authors: Pearce JG,Maddess T

    更新日期:2019-04-01 00:00:00

  • Macular and retinal nerve fiber layer thickness measurement reproducibility using optical coherence tomography (OCT-3).

    abstract:PURPOSE:To assess the reproducibility of retinal nerve fiber layer thickness and macular thickness measurements using OCT-3. METHODS:Randomly chosen eyes of healthy individuals were scanned following pupillary dilation by two trained operators (RGO, RV) using OCT-3 (software version A1.1, Carl Zeiss Meditec, Inc., Dub...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/00061198-200406000-00012

    authors: Gürses-Ozden R,Teng C,Vessani R,Zafar S,Liebmann JM,Ritch R

    更新日期:2004-06-01 00:00:00

  • Scanning laser polarimetry with enhanced corneal compensation in patients with open-angle glaucoma.

    abstract:AIMS:To compare the retinal nerve fiber layer thickness (RNFLT) parameters obtained with newly introduced GDx with enhanced corneal compensation (ECC) and those with GDx with variable corneal compensation (VCC) and to evaluate their reproducibility and the correspondence with visual field damage (VFD) in total or secto...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0b013e318133fb47

    authors: Saito H,Tomidokoro A,Yanagisawa M,Aihara M,Tomita G,Araie M

    更新日期:2008-01-01 00:00:00

  • Perfusion of the juxtapapillary retina and the neuroretinal rim area in primary open angle glaucoma.

    abstract:PURPOSE:The objective of this study is to evaluate capillary blood flow of the juxtapapillary retina and neuroretinal rim area in primary open angle glaucoma (POAG) by a new noninvasive method performing a high-definition topography of perfused vessels of the retina and the optic nerve head with simultaneous evaluation...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:

    authors: Michelson G,Langhans MJ,Groh MJ

    更新日期:1996-04-01 00:00:00

  • Acute angle-closure glaucoma in a patient with miller fisher syndrome without pupillary dysfunction.

    abstract:PURPOSE:To report a case of an angle-closure glaucoma in a patient with Miller Fisher syndrome (MFS) without pupillary dysfunction. METHODS:We present a case report of a 75-year-old male presenting with total ophthalmoplegia, complete bilateral ptosis, and gait disturbance. He was diagnosed with MFS without pupillary ...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000000191

    authors: Ryu WY,Kim JK,Jin SW,Shim DH

    更新日期:2015-02-01 00:00:00

  • Influence of total energy delivery on success rate after contact diode laser transscleral cyclophotocoagulation: a retrospective case review and meta-analysis.

    abstract:PURPOSE:To evaluate the effect of a single treatment of contact diode laser transscleral cyclophotocoagulation (TSCP) on intraocular pressure (IOP) in patients with refractory glaucoma and perform a historical meta-analysis of the relationship between successful IOP control and various laser parameters. METHODS:Clinic...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章,meta分析

    doi:10.1097/00061198-200208000-00009

    authors: Hauber FA,Scherer WJ

    更新日期:2002-08-01 00:00:00

  • Inadvertent filtering bleb due to corneal stromal wick syndrome.

    abstract::We report a unique case in which an inadvertent filtering bleb was created after a complicated cataract surgery through an unusual mechanism: an internal fragment of corneal stroma, which was still attached at one end of the clear corneal wound, was pushed into the anterior chamber, became inadvertently entrapped in t...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0b013e3182a07604

    authors: Alasil T,Jakobiec FA,Zakka FR,Gardiner M,Chen TC

    更新日期:2013-09-01 00:00:00

  • Obstructive Sleep Apnea and Retinal Nerve Fiber Layer Thickness: A Meta-analysis.

    abstract:STUDY OBJECTIVES:The association between obstructive sleep apnea syndrome (OSAS) and retinal nerve fiber layer (RNFL) thickness has been examined in many studies. However, the findings are inconsistent. Our goal is to evaluate the association between OSAS and RNFL thickness by performing a meta-analysis. METHODS:We co...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章,meta分析

    doi:10.1097/IJG.0000000000000349

    authors: Zhao XJ,Yang CC,Zhang JC,Zheng H,Liu PP,Li Q

    更新日期:2016-04-01 00:00:00

  • Management of blebitis by members of the American Glaucoma Society: a survey.

    abstract:PURPOSE:To investigate the practice patterns among glaucoma subspecialists in the American Glaucoma Society regarding the management of blebitis. METHODS:An anonymous survey incorporating 14 questions regarding the management of blebitis was mailed to all current active American Glaucoma Society members, including pro...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/00061198-200108000-00015

    authors: Reynolds AC,Skuta GL,Monlux R,Johnson J

    更新日期:2001-08-01 00:00:00