Relationship Between OCT Angiography Temporal Peripapillary Vessel-Density and Octopus Perimeter Paracentral Cluster Mean Defect.

Abstract:

PURPOSE OF THE STUDY:The purpose of the study was to investigate the relationship between optical coherence tomography angiography angioflow vessel-density (PAFD) measured in the retinal nerve fiber layer in the temporal peripapillary sector and the average of the spatially corresponding superior and inferior paracentral cluster mean defect values (mean paracentral MD) measured with Octopus perimetry. MATERIALS AND METHODS:Spaerman's correlation between temporal peripapillary PAFD acquired with the Angiovue OCT and mean paracentral MD measured with the Normal and tendency-oriented perimetry strategy of Octopus G2 perimetry, respectively, was determined on 1 eye of 13 healthy participants, 22 medically controlled ocular hypertensive, and 27 stable early to moderate glaucoma patients. Octopus perimetry was made within 3 months from optical coherence tomography angiography imaging. RESULTS:Strong negative relationship was found irrespective to Octopus test strategy between temporal sector peripapillary PAFD and mean paracentral MD for the total population (r-values: -0.5525 and -0.4496, respectively, P≤0.002), the glaucoma group (r-values: -0.4901 and -0.4936, respectively, P<0.01) and the ocular hypertensive group (r-values: -0.4445 and -0.4496, P≤0.0382). For the healthy eyes, and for all groups when correction for the diffuse defect component of global MD was made using the perimeter's software, no significant relationship was found. CONCLUSIONS:Strong negative relationship exists between the temporal peripapillary sector PAFD measured with Angiovue OCT angiography in the retinal nerve fiber layer and mean paracentral cluster MD determined with uncorrected Normal and tendency-oriented perimetry strategies of Octopus perimetry. This relationship may be usefully applied in research when eyes with paracentral scotomas are investigated.

journal_name

J Glaucoma

journal_title

Journal of glaucoma

authors

Holló G

doi

10.1097/IJG.0000000000000630

subject

Has Abstract

pub_date

2017-05-01 00:00:00

pages

397-402

issue

5

eissn

1057-0829

issn

1536-481X

journal_volume

26

pub_type

杂志文章
  • Preliminary Report on a Novel Virtual Reality Perimeter Compared With Standard Automated Perimetry.

    abstract:PRECIS:The VisuALL head-mounted perimetry in normal subjects and glaucoma patients had a moderate to strong correlation with the Humphrey Field Analyzer (HFA). PURPOSE:Visual field testing has a vital role in diagnosing and managing glaucoma. The current clinical practice relies on large, table-based testing units. Th...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000001670

    authors: Razeghinejad R,Gonzalez-Garcia A,Myers JS,Katz LJ

    更新日期:2021-01-01 00:00:00

  • Macular and retinal nerve fiber layer thickness measurement reproducibility using optical coherence tomography (OCT-3).

    abstract:PURPOSE:To assess the reproducibility of retinal nerve fiber layer thickness and macular thickness measurements using OCT-3. METHODS:Randomly chosen eyes of healthy individuals were scanned following pupillary dilation by two trained operators (RGO, RV) using OCT-3 (software version A1.1, Carl Zeiss Meditec, Inc., Dub...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/00061198-200406000-00012

    authors: Gürses-Ozden R,Teng C,Vessani R,Zafar S,Liebmann JM,Ritch R

    更新日期:2004-06-01 00:00:00

  • Comparison of Anterior Segment Optical Coherence Tomography Bleb Grading, Moorfields Bleb Grading System, and Intraocular Pressure After Trabeculectomy.

    abstract:PURPOSE:To compare a novel anterior segment optical coherence tomography (AS-OCT) bleb grading system with a clinical bleb grading system and both with intraocular pressure (IOP) following trabeculectomy surgery. MATERIALS AND METHODS:A novel AS-OCT grading system based on bleb size and internal reflectivity was devel...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000000636

    authors: Wen JC,Stinnett SS,Asrani S

    更新日期:2017-05-01 00:00:00

  • Micropulse Trans-scleral Cyclophotocoagulation in Patients With Glaucoma: 1- and 2-Year Treatment Outcomes.

    abstract::PRéCIS:: Micropulse trans-scleral cyclophotocoagulation (TSCPC) is an effective and safe IOP-lowering treatment for patients with primary or secondary glaucoma. PURPOSE:To investigate the 1-year and 2-year effect on intraocular pressure (IOP) and safety profile of micropulse TSCPC in patients with glaucoma. METHODS:...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000001552

    authors: de Crom RMPC,Slangen CGMM,Kujovic-Aleksov S,Webers CAB,Berendschot TTJM,Beckers HJM

    更新日期:2020-09-01 00:00:00

  • Retinal nerve fiber layer measurement of the Hong Kong chinese population by optical coherence tomography.

    abstract:PURPOSE:To obtain retinal nerve fiber layer (RNFL) measurements by optical coherence tomography in a local, normal Hong Kong Chinese population and to identify the correlation of the measurement with age cross-sectionally. METHODS:A total of 129 normal Hong Kong Chinese volunteers of different age groups were recruite...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/00061198-200212000-00004

    authors: Mok KH,Lee VW,So KF

    更新日期:2002-12-01 00:00:00

  • Comparison of Ab Externo and Ab Interno 360-degree Suture Trabeculotomy in Adult Open-angle Glaucoma.

    abstract:PRECIS:Ab interno (gonioscopy-assisted transluminal trabeculotomy) and ab externo 360-degree suture trabeculotomy (ST) achieved similar success rates for reducing intraocular pressure (IOP) without serious complications threatening visual acuity. PURPOSE:We aimed to compare the efficacy of ab externo and ab interno 36...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000001627

    authors: Yalinbas D,Dilekmen N,Hepsen IF

    更新日期:2020-11-01 00:00:00

  • Ahmed glaucoma valve implantation with tube insertion through the ciliary sulcus in pseudophakic/aphakic eyes.

    abstract:PURPOSE:To report the efficacy and safety of Ahmed glaucoma valve (AGV) insertion into the ciliary sulcus in pseudophakic/aphakic patients. PATIENTS AND METHODS:A chart review was done on patients with uncontrolled glaucoma, who underwent AGV implantation with tube inserted into the ciliary sulcus. Baseline intraocula...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0b013e318265bc0b

    authors: Eslami Y,Mohammadi M,Fakhraie G,Zarei R,Moghimi S

    更新日期:2014-02-01 00:00:00

  • Relationship Between Serum Glucose Levels and Intraocular Pressure, a Population-based Cross-sectional Study.

    abstract:PURPOSE:The purpose of this study is to assess the relationship between serum glucose levels and intraocular pressure (IOP) both in subjects with impaired fasting glucose (IFG) as well as in subjects with diabetes mellitus (DM). MATERIALS AND METHODS:Data of a cross-sectional sample of 18,406 subjects who underwent ro...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000000700

    authors: Cohen E,Kramer M,Shochat T,Goldberg E,Krause I

    更新日期:2017-07-01 00:00:00

  • Transconjunctival mitomycin C as an adjunct to conventional glaucoma filtration surgery in rabbits.

    abstract:PURPOSE:Subconjunctival mitomycin C has been used in glaucoma filtration surgery with success. A prospective, randomized, masked, placebo-controlled study was performed to evaluate whether single transconjunctival mitomycin C applied either preoperatively or postoperatively would enhance the success of filtration surge...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:

    authors: Buffenn AN,Saetre SB,Higginbotham EJ,Musch DC,Kincaid MC

    更新日期:1997-10-01 00:00:00

  • Genetic analysis of PITX2 and FOXC1 in Rieger Syndrome patients from Brazil.

    abstract:PURPOSE:Axenfeld-Rieger syndrome is a genetically heterogeneous, autosomal dominant disorder that is characterized by anterior segment defects, glaucoma, and extraocular anomalies. This study examined the two genes known to cause Rieger syndrome, PITX2 and FOXC1, for mutations in five Brazilian families with Axenfeld-R...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/00061198-200202000-00010

    authors: Borges AS,Susanna R Jr,Carani JC,Betinjane AJ,Alward WL,Stone EM,Sheffield VC,Nishimura DY

    更新日期:2002-02-01 00:00:00

  • Surgical Technique for Pars Plana Ahmed Glaucoma Valve Implantation in Advanced Glaucoma: The Upside-Down Technique.

    abstract:PRCIS:Ahmed glaucoma valve implantation using the upside-down technique resulted in an aqueous humor outflow pathway, occurring primarily on the scleral side and secondarily on the conjunctival side, and was effective in treating refractory glaucoma. PURPOSE:To describe the Ahmed glaucoma valve (AGV) surgical techniqu...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000001791

    authors: Masuda Y,Saito Y,Oki T,Hayashi T,Takahashi G,Nakano T

    更新日期:2021-01-13 00:00:00

  • Outcomes of pars plana glaucoma drainage implant in Boston type 1 keratoprosthesis surgery.

    abstract:PURPOSE:Glaucoma drainage implantation in conjunction with Boston Type 1 Keratoprosthesis placement is a surgical option in controlling postoperative glaucoma. The purpose of this study is to report outcomes of combined pars plana vitrectomy and glaucoma drainage implantation with corneal patch graft in Boston Type 1 K...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0b013e31829e55f8

    authors: Huh ES,Aref AA,Vajaranant TS,de la Cruz J,Chau FY,Cortina MS

    更新日期:2014-01-01 00:00:00

  • Accuracy of Measurements With the iCare HOME Rebound Tonometer.

    abstract:PURPOSE:To evaluate the accuracy of intraocular pressure (IOP) measurements obtained with the newly available iCare HOME (RTHOME) rebound tonometer compared with the iCare ONE (RTONE) tonometer and Goldmann applanation tonometry (GAT), and possible correlation with central corneal thickness (CCT). MATERIALS AND METHOD...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章,随机对照试验

    doi:10.1097/IJG.0000000000000390

    authors: Termühlen J,Mihailovic N,Alnawaiseh M,Dietlein TS,Rosentreter A

    更新日期:2016-06-01 00:00:00

  • The Clinical Interpretation of Changes in Intraocular Pressure Measurements Using Goldmann Applanation Tonometry: A Review.

    abstract:PURPOSE:The interpretation of changes in serial intraocular pressure (IOP) measurements are critical in the diagnosis and management of glaucoma. Differentiating true change from test-retest variability (TRV) in IOP measurements using Goldmann applanation tonometry (IOPG) is essential when reviewing these measurements....

    journal_title:Journal of glaucoma

    pub_type: 杂志文章,评审

    doi:10.1097/IJG.0000000000001144

    authors: Pearce JG,Maddess T

    更新日期:2019-04-01 00:00:00

  • A Role for Clusterin in Exfoliation Syndrome and Exfoliation Glaucoma?

    abstract::The multifunctional protein clusterin (CLU) is a secreted glycoprotein ubiquitously expressed throughout the body, including in the eye. Its primary function is to act as an extracellular molecular chaperone, preventing the precipitation and aggregation of misfolded extracellular proteins. Clusterin is commonly identi...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章,评审

    doi:10.1097/IJG.0000000000000916

    authors: Wiggs JL,Kang JH,Fan B,Levkovitch-Verbin H,Pasquale LR

    更新日期:2018-07-01 00:00:00

  • A comparative study between diode laser cyclophotocoagulation and the Ahmed glaucoma valve implant in neovascular glaucoma: a long-term follow-up.

    abstract:BACKGROUND:To compare the efficacy, safety, and long-term results of intraocular pressure (IOP) reduction by diode laser contact cyclophotocoagulation (DCPC) and Ahmed glaucoma valve (AGV) implant in cases of neovascular glaucoma. METHODS:A total of 66 eyes of 66 patients with neovascular glaucoma were prospectively a...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0b013e31817d235c

    authors: Yildirim N,Yalvac IS,Sahin A,Ozer A,Bozca T

    更新日期:2009-03-01 00:00:00

  • Static and Dynamic Pupillary Characteristics in Clinically Unilateral Pseudoexfoliation Syndrome.

    abstract:PURPOSE:The purpose of this study was to perform a comparison of static and dynamic pupillometry measurements in patients with clinically unilateral pseudoexfoliation syndrome (PES) and age-matched controls. METHODS:This prospective cross-sectional study consisted of 38 patients with unilateral PES and 40 control part...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000000953

    authors: Tekin K,Sekeroglu MA,Kiziltoprak H,Yetkin E,Doguizi S,Yilmazbas P

    更新日期:2018-06-01 00:00:00

  • Primary Open-angle Glaucoma and Increased Risk of Chronic Kidney Disease.

    abstract:PRECIS:The association between primary open-angle glaucoma (POAG) and subsequent development of chronic kidney disease (CKD) was investigated using a nationwide, population-based, retrospective cohort in South Korea. POAG increases the risk of subsequent CKD development. PURPOSE:The purpose of this study was to invest...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000001390

    authors: Park SJ,Byun SJ,Park JY,Kim M

    更新日期:2019-12-01 00:00:00

  • Peripapillary focal retinal arteriolar narrowing in open angle glaucoma.

    abstract:PURPOSE:Optic disc photographs of 750 patients attending a glaucoma practice were examined to identify focal peripapillary arteriolar narrowing. METHODS:A subgroup of 110 of these patients' photographs, who had also had finger circulation tested for vasospasm to cold, were divided into patients with peripapillary foca...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:

    authors: Rankin SJ,Drance SM

    更新日期:1996-02-01 00:00:00

  • High failure rate associated with 180 degrees selective laser trabeculoplasty.

    abstract:PURPOSE:To determine the efficacy of selective laser trabeculoplasty (SLT) in a tertiary care referral center. PATIENTS AND METHODS:In this retrospective study of selective laser trabeculoplasty performed by five physicians, 94 eyes from 94 patients were included. A majority (83/92, 90%) underwent 180 degrees selectiv...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/01.ijg.0000176939.43681.c2

    authors: Song J,Lee PP,Epstein DL,Stinnett SS,Herndon LW Jr,Asrani SG,Allingham RR,Challa P

    更新日期:2005-10-01 00:00:00

  • A review: "a comparison of treated and untreated glaucoma suspects" (4).

    abstract:OBJECTIVES:This study was conducted to evaluate the effect of long-term intraocular pressure reduction with timolol on the incidence of glaucomatous visual field defects and optic nerve cupping in individuals with ocular hypertension and to compare this incidence with that of a similar group on no treatment. ...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:

    authors: Vogel R

    更新日期:1993-01-01 00:00:00

  • The Effect of Suture Wick Technique on Early Intraocular Pressure Control After Nonvalved (Baerveldt 350) Glaucoma Drainage Device Surgery.

    abstract:PURPOSE:The purpose of this study was to compare early postoperative outcomes of patients who underwent Baerveldt 350-mm aqueous drainage device (Abbott Medical Optics Inc., Santa Ana, CA) implantation with and without 7-0 polyglactin (vicryl) suture placement through tube fenestration to serve as a stenting wick. MET...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000001080

    authors: Rothman AL,An SJ,Herndon LW Jr

    更新日期:2018-12-01 00:00:00

  • Measurement of ocular blood flow.

    abstract::Many of these techniques have been adapted to investigate hemodynamic alterations, not only in glaucoma, but in diverse disorders such as diabetic retinopathy, macular degeneration, retinal dystrophies, and nonglaucomatous optic neuropathies. However, each of these techniques has limitations and there is not a single ...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章,评审

    doi:10.1097/00061198-200110001-00022

    authors: Cioffi GA,Alm A

    更新日期:2001-10-01 00:00:00

  • The effect of dehydration and fasting on ocular blood flow.

    abstract:PURPOSE:To investigate the effects of dehydration and fasting on retrobulbar-vessel blood velocity in healthy subjects. METHODS:Twenty-eight eyes of 28 normal subjects without ocular disease were enrolled in this study. Each subject had a baseline color-Doppler imaging ultrasound of the central retinal artery, tempora...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/00061198-200210000-00007

    authors: Inan UU,Yücel A,Ermis SS,Oztürk F

    更新日期:2002-10-01 00:00:00

  • Health Economic Analysis in Glaucoma.

    abstract::The pressure on glaucoma services is ever-growing, and policymakers seek robust cost-effectiveness arguments in their decisions around resource allocation. The benefits of glaucoma are in preventing or delaying a future loss of vision and associated quality of life, and this expectation is quantified using a metric ca...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章,评审

    doi:10.1097/IJG.0000000000001462

    authors: Park I,Gale J,Skalicky SE

    更新日期:2020-04-01 00:00:00

  • Technique for removal of malpositioned Ex-PRESS glaucoma device.

    abstract:PURPOSE:To report a simple technique for removal of malpositioned Ex-PRESS miniature glaucoma filtration device. PATIENT AND METHODS:A patient who underwent removal of a malpositioned Ex-PRESS shunt from the right eye with wound revision. RESULTS:Description of step-by-step technique for removal of the Ex-PRESS shunt...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0b013e31827b1540

    authors: Khouri AS,Khan MN,Fechtner RD,Vold SD

    更新日期:2014-09-01 00:00:00

  • "Bleb window"-pexy for the management of symptomatic, oversized blebs.

    abstract:PURPOSE:To describe a simple method and outcomes of remodeling dysesthetic, oversized filtering blebs. PATIENTS AND METHODS:Retrospective chart review of the initial consecutive patients who had undergone "bleb window"-pexy (BWP) over a 1-year period. Patients with symptomatic, oversized, and dysmorphic blebs that did...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0b013e3181815a06

    authors: Tabet R,Feldman RM,Bell NP,Lee DA

    更新日期:2009-09-01 00:00:00

  • Even-number Measurement Bias With Goldmann Applanation Tonometry.

    abstract::While working with a large data set of Goldmann applanation tonometry (GAT) intraocular pressure (IOP) measurements for a separate investigation, we observed that the IOP distribution favored even-numbered values. Study of this phenomenon has been limited, and this larger data set enabled inquiry that showed new insig...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000001412

    authors: Rozwat A,Roberts DK

    更新日期:2020-02-01 00:00:00

  • Comparison of Thickness-Function and Vessel Density-Function Relationship in the Superior and Inferior Macula, and in the Superotemporal and Inferotemporal Peripapillary Sectors.

    abstract::PRéCIS:: In primary open-angle glaucoma (POAG), unlogged mean macular hemifield visual field sensitivity correlates significantly better with superficial capillary vessel density (VD) than with ganglion cell complex (GCC) thickness of the opposite macular hemifield. PURPOSE:The aim of this study was to compare the re...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000001441

    authors: Holló G

    更新日期:2020-03-01 00:00:00

  • Scleral indentation optimizes visualization of anterior chamber angle during goniosynechialysis.

    abstract:PURPOSE:To propose a new surgical technique for optimized visualization of the chamber angle using scleral indentation under an operating microscope in goniosynechialysis (GSL). PATIENTS AND METHODS:Six volunteers with normal chamber angle and five patients with synechial angle closure glaucoma were examined. Scleral ...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/01.ijg.0000170061.51878.02

    authors: Takanashi T,Masuda H,Tanito M,Nonoyama S,Katsube T,Ohira A

    更新日期:2005-08-01 00:00:00