Abstract:
PURPOSE:To evaluate the accuracy of intraocular pressure (IOP) measurements obtained with the newly available iCare HOME (RTHOME) rebound tonometer compared with the iCare ONE (RTONE) tonometer and Goldmann applanation tonometry (GAT), and possible correlation with central corneal thickness (CCT). MATERIALS AND METHODS:IOP measurements were obtained from 154 patients by an ophthalmologist (doc) using each of the above-mentioned tonometers. In addition, patients (pat) measured their own IOP with the RTHOME and RTONE. The means and SD of results obtained with the different tonometers were compared. Agreement between the tonometers was calculated using the Bland-Altman method. RESULTS:Mean IOPs for the right eyes only were 15.9±6.4 mm Hg (RTONEdoc), 15.8±6.4 mm Hg (RTONEpat), 15.0±5.9 mm Hg (RTHOMEdoc), 14.9±6.3 mm Hg (RTHOMEpat), and 15.8±4.4 mm Hg (GAT). Bland-Altman analysis revealed mean differences (bias) between RTONEdoc and RTHOMEdoc, between RTHOMEdoc and RTHOMEpat, and between RTHOMEdoc and GAT of 0.8, 0.1, and -0.8 mm Hg, respectively, with 95% limits of agreement of -3.5 to 5.2, -4.9 to 5.1, and -7.2 to 5.6 mm Hg, respectively. Linear regression of the comparisons revealed a proportional error over the range of pressures examined in the case of RTHOMEdoc versus GAT (slope=0.32, P<0.001). Considering the data from all eyes, the difference between RTHOMEdoc and GAT correlated significantly with the CCT (P=0.01). CONCLUSION:RTHOME readings correlate well with the GAT results although some limitations such as dependency of readings on CCT and increasing differences at lower and higher IOP levels need to be taken into account.
journal_name
J Glaucomajournal_title
Journal of glaucomaauthors
Termühlen J,Mihailovic N,Alnawaiseh M,Dietlein TS,Rosentreter Adoi
10.1097/IJG.0000000000000390subject
Has Abstractpub_date
2016-06-01 00:00:00pages
533-8issue
6eissn
1057-0829issn
1536-481Xjournal_volume
25pub_type
杂志文章,随机对照试验abstract::PRéCIS:: In this study, we report clinical results after implantation of an adjustable glaucoma drainage device. The intraocular pressure (IOP) profile was efficiently controlled postoperatively as the resistance to aqueous humor outflow was finely adjusted. PURPOSE:The main purpose of this study was to evaluate the ...
journal_title:Journal of glaucoma
pub_type: 临床试验,杂志文章,多中心研究
doi:10.1097/IJG.0000000000001209
更新日期:2019-05-01 00:00:00
abstract:PURPOSE:To examine the relationship between retinal ganglion cell function measured using pattern electroretinogram optimized for glaucoma screening (PERGLA), retinal nerve fiber layer (RNFL) thickness, and optic nerve head topography. METHODS:Twenty-nine normal, 28 glaucoma, and 37 glaucoma suspect volunteers were en...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0b013e31819afb5c
更新日期:2009-10-01 00:00:00
abstract:PURPOSE:To compare the results of frequency-doubling technology perimetry (FDT), assumed to test the magnocellular visual pathway, and high-pass resolution perimetry (HRP), assumed to test the parvocellular visual pathway, in patients with ocular hypertension or glaucoma. PATIENTS AND METHODS:Forty-eight consecutive p...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/00061198-200302000-00008
更新日期:2003-02-01 00:00:00
abstract:PRCIS:Use of toric intraocular lenses is a reasonable option for better visual outcomes when a combined minimally invasive glaucoma surgery (MIGS) and cataract surgery is performed in eyes with corneal astigmatism. PURPOSE:To assess the efficacy of toric intraocular lenses (IOLs) in combined cataract and MIGS, visual ...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0000000000001705
更新日期:2021-01-01 00:00:00
abstract:PURPOSE:To describe the outcome of surgical bleb revision for late-onset bleb leaks after trabeculectomy. PATIENTS AND METHODS:Appropriate cases were identified. Qualified and complete success required intraocular pressure of 21 mm Hg or less with and without glaucoma medication use, respectively. Bleb survival was de...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0b013e31821e83e6
更新日期:2013-01-01 00:00:00
abstract::A 54-year-old woman who presented with photopsia was found to have elevated intraocular pressure in both eyes and optic disc cupping in the right eye. Angle infiltration was noted on gonioscopy. She was previously been diagnosed with metastatic breast cancer. This case report describes a rare case of glaucoma as a com...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0000000000001445
更新日期:2020-03-01 00:00:00
abstract:PURPOSE:Evaluate the long-term results of the Ahmed glaucoma valve (AGV) surgery in association with bevacizumab (Avastin) in neovascular glaucoma (NVG) patients. DESIGN AND METHODS:This retrospective institutional study reviewed 39 eyes of 34 patients with NVG who underwent AGV implantation. The intravitreal bevacizu...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0000000000000234
更新日期:2015-06-01 00:00:00
abstract:PURPOSE:To evaluate the efficacy of CO2 laser-assisted sclerectomy surgery (CLASS) compared with classic nonpenetrating deep sclerectomy (NPDS) with implant in medically uncontrolled glaucoma patients. MATERIALS AND METHODS:Patients who underwent primary filtration surgery with CO2 laser system at the time interval be...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0000000000000187
更新日期:2016-07-01 00:00:00
abstract:PRCIS:Ahmed glaucoma valve implantation using the upside-down technique resulted in an aqueous humor outflow pathway, occurring primarily on the scleral side and secondarily on the conjunctival side, and was effective in treating refractory glaucoma. PURPOSE:To describe the Ahmed glaucoma valve (AGV) surgical techniqu...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0000000000001791
更新日期:2021-01-13 00:00:00
abstract:PURPOSE:Traditionally, during trabeculectomy, Mitomycin-C (MMC) is applied to the tissues using surgical sponges. However, alternate modes of application exist. This study assessed the success rates, complication rates, final intraocular pressure (IOP), and bleb characteristics between patients receiving subtenon MMC a...
journal_title:Journal of glaucoma
pub_type: 杂志文章,随机对照试验
doi:10.1097/IJG.0000000000000830
更新日期:2018-02-01 00:00:00
abstract:PURPOSE:To evaluate circulatory melatonin levels by assessing nocturnal urinary excretion of 6-sulfatoxymelatonin (aMT6s) in patients with primary open-angle glaucoma (POAG) and to compare the high-tension group and the low-tension group. METHODS:This study included 80 eyes of 41 POAG patients and 87 eyes of 44 contro...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0000000000001130
更新日期:2019-02-01 00:00:00
abstract:PURPOSE:To evaluate the usefulness of day-long sequential office measurements of intraocular pressure (IOP) to make therapeutic decisions in patients with progressive glaucomatous damage despite apparently 'controlled' IOP. METHODS:We reviewed the records of 93 consecutive glaucoma patients (185 eyes) who underwent se...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/01.ijg.0000159125.34241.79
更新日期:2005-06-01 00:00:00
abstract:SUMMARY:Subconjunctival fibrosis is one of the major causes of most bleb failures. To inhibit the wound-healing process and to achieve a better intraocular pressure (IOP) lowering effect as well as bleb formation, we performed a sclerostomy using a THC:YAG laser (thulium, holmium, and chromium-doped yttrium-aluminum-ga...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:
更新日期:1993-01-01 00:00:00
abstract:PURPOSE:To describe a simple method and outcomes of remodeling dysesthetic, oversized filtering blebs. PATIENTS AND METHODS:Retrospective chart review of the initial consecutive patients who had undergone "bleb window"-pexy (BWP) over a 1-year period. Patients with symptomatic, oversized, and dysmorphic blebs that did...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0b013e3181815a06
更新日期:2009-09-01 00:00:00
abstract:PURPOSE:Estimate patient adherence to glaucoma medications and identify potential determinants of nonadherence. DESIGN:Descriptive study. METHODS:Two hundred patients with open angle glaucoma, ocular hypertension, or glaucoma suspects were interviewed regarding their glaucoma and its treatment and their charts were r...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0b013e3181815421
更新日期:2009-03-01 00:00:00
abstract:PURPOSE:To investigate the effect of modern vaginal labor using epidural anesthesia on the intraocular pressure (IOP) and on the mean ocular perfusion pressure (MOPP) in healthy women. PATIENTS AND METHODS:In this prospective observational study, eligible candidates were healthy pregnant women for vaginal delivery wit...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0000000000000559
更新日期:2017-01-01 00:00:00
abstract:PRECIS:Citicoline eyedrops in patients with progressing glaucoma. PURPOSE:This study aimed to test whether the additional therapy with citicoline eyedrops to intraocular pressure (IOP)-lowering treatment could slow glaucoma progression in patients with worsening of damage and IOP 18 mm Hg or less. DESIGN:This was a r...
journal_title:Journal of glaucoma
pub_type: 杂志文章,多中心研究,随机对照试验
doi:10.1097/IJG.0000000000001565
更新日期:2020-07-01 00:00:00
abstract:BACKGROUND:To compare the efficacy, safety, and long-term results of intraocular pressure (IOP) reduction by diode laser contact cyclophotocoagulation (DCPC) and Ahmed glaucoma valve (AGV) implant in cases of neovascular glaucoma. METHODS:A total of 66 eyes of 66 patients with neovascular glaucoma were prospectively a...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0b013e31817d235c
更新日期:2009-03-01 00:00:00
abstract:PRECIS:Surgeons that perform cataract surgery combined with endocyclophotocoagulation should rely on their preferred IOL calculation formula. There is no need to perform any correction to the IOL power, as this procedure does not modify the refractive outcome. PURPOSE:To compare postoperative refractive outcomes in pa...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0000000000001777
更新日期:2020-12-29 00:00:00
abstract::The pressure on glaucoma services is ever-growing, and policymakers seek robust cost-effectiveness arguments in their decisions around resource allocation. The benefits of glaucoma are in preventing or delaying a future loss of vision and associated quality of life, and this expectation is quantified using a metric ca...
journal_title:Journal of glaucoma
pub_type: 杂志文章,评审
doi:10.1097/IJG.0000000000001462
更新日期:2020-04-01 00:00:00
abstract::Intraocular pressure (IOP) is a dynamic physiologic parameter with regular circadian variations and unpredictable short-term and long-term fluctuations. Current methods of measuring IOP are suboptimal with a typical clinical practice only performing periodic IOP measurements during regular office hours. Diurnal and 24...
journal_title:Journal of glaucoma
pub_type: 杂志文章,评审
doi:10.1097/IJG.0b013e3181862490
更新日期:2009-04-01 00:00:00
abstract:PURPOSE:To determine the effect of cataract extraction on the glaucoma progression index (GPI) in glaucoma patients with coexisting cataract. PATIENTS AND METHODS:This is a retrospective noncomparative study. Consecutive eligible patients with glaucoma who underwent phacoemulsification alone or in combination with aug...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0b013e3181b21fb9
更新日期:2010-04-01 00:00:00
abstract:PURPOSE:The author studied the effects of pupillary dilation on perimetry in a group of glaucomatous patients receiving timolol therapy. PATIENTS AND METHODS:A prospective study compared the visual fields of 23 patients with primary open-angle glaucoma of varying severity (mean defect: 3.84; short-term fluctuation: 1....
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:
更新日期:1997-08-01 00:00:00
abstract:PURPOSE:To report on the prevalence of pseudoexfoliation (PEX) and its association with ophthalmic characteristics and systemic diseases in a well-defined population. METHODS:The Thessaloniki Eye study is a cross-sectional population-based study of chronic eye diseases in Thessaloniki, Greece. Participants with PEX we...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0b013e3181d9d8bd
更新日期:2011-03-01 00:00:00
abstract:PURPOSE:Microvasculature dropout (MvD) is a novel finding seen in optical coherence tomography angiography (OCTA), which is characterized by a localized dehiscence of the choriocapillaris in the parapapillary atrophy area. Disc hemorrhage (DH) is an important factor often associated with the development and especially ...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0000000000001688
更新日期:2021-01-01 00:00:00
abstract:PURPOSE:To report 2 cases of delayed-onset, bleb-related endophthalmitis induced by Gemella species. METHODS:Interventional case report. RESULTS:Two patients developed bleb-related ocular infection attributable to Gemella haemolysans and Gemella morbillorum after trabeculectomy with adjunctive mitomycin C. Both patie...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0b013e31818c6f07
更新日期:2009-08-01 00:00:00
abstract:PURPOSE:The aim of this study is to evaluate the safety and efficacy of laser goniopuncture (LGP) to lower intraocular pressure (IOP) post-viscocanalostomy (VC)/phacoviscocanalostomy (PVC). Outcomes include: IOP reduction from pre-LGP levels and the need for further topical antiglaucomatous medication or surgery. PATI...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0000000000000333
更新日期:2016-06-01 00:00:00
abstract:PURPOSE:To determine whether the multifocal visual evoked potential (mfVEP) technique can detect early functional damage in ocular hypertensive (OHT) and glaucoma suspect (GS) patients with normal standard achromatic automated perimetry (SAP) results. PATIENTS AND METHODS:Twenty-five GS patients (25 eyes), 25 patients...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/01.ijg.0000212237.26466.0e
更新日期:2006-08-01 00:00:00
abstract:PURPOSE:To find the dropout rate and identify the clinical characteristics of patients who drop out in the first year of follow-up from a glaucoma clinic. DESIGN:Descriptive hospital-based study at a tertiary hospital eye department. METHODS:Clinical characteristics of consecutive patients newly diagnosed with glauco...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0b013e31815768b3
更新日期:2008-04-01 00:00:00
abstract:PURPOSE:To investigate the relationship between the peripapillary retinal nerve fiber layer (RNFL) thickness, as measured by Stratus time domain optical coherence tomography (OCT) (Stratus OCT) and Cirrus spectral domain OCT (Cirrus HD-OCT), and the severity indices of the visual field (VF) defects in glaucoma patients...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0b013e3181efb371