Abstract:
:PRéCIS:: In this study, we report clinical results after implantation of an adjustable glaucoma drainage device. The intraocular pressure (IOP) profile was efficiently controlled postoperatively as the resistance to aqueous humor outflow was finely adjusted. PURPOSE:The main purpose of this study was to evaluate the safety and efficacy of the new adjustable glaucoma drainage device eyeWatch used in conjunction with a Baerveldt glaucoma implant in refractory glaucoma. PATIENTS AND METHODS:This was a multicentric, prospective, noncomparative clinical trial. Patients older than 18 years of age suffering from refractory glaucoma after failed surgeries, with IOP of ≥20 mm Hg, in whom a further glaucoma procedure using an aqueous shunt was planned, were enrolled in this study. The primary outcome was the success rate, defined as an IOP≤18 mm Hg and reduction of >20% from baseline, IOP≥6 mm Hg. Secondary outcomes were mean IOP, visual acuity, number of antiglaucoma medications, number, and type of complications. RESULTS:Fifteen patients were included. The mean follow-up time was 15.6±3.5 months. The mean baseline IOP decreased from 26.2±6.8 mm Hg before surgery to 11.9±2.8 mm Hg at 12 months (P<0.001). The mean number of glaucoma medications decreased from 3.0±0.7 before surgery to 0.8±0.9 at last visit (P<0.001). The success rate was 40% for complete success and 93% for overall success at last follow-up. Complication rate was 7%. CONCLUSIONS:The novel glaucoma device allows for perioperative and postoperative noninvasive adjustments of the resistance to aqueous humor outflow. This leads to better management of IOP during the early postoperative period, preventing ocular hypotony and eliminating the need for obstructive elements and reinterventions. The rate of complications was low, IOP was adequately controlled and lowered, with a substantial reduction in the number of antiglaucoma medication.
journal_name
J Glaucomajournal_title
Journal of glaucomaauthors
Roy S,Villamarin A,Stergiopulos C,Bigler S,Guidotti J,Stergiopulos N,Kniestedt C,Mermoud Adoi
10.1097/IJG.0000000000001209subject
Has Abstractpub_date
2019-05-01 00:00:00pages
452-458issue
5eissn
1057-0829issn
1536-481Xpii
00061198-201905000-00015journal_volume
28pub_type
临床试验,杂志文章,多中心研究abstract:PURPOSE:To determine if a new, normative, race-specific database enhances the ability of confocal scanning laser ophthalmoscopy to differentiate normal from glaucomatous eyes. METHODS:One eye of eligible normal and glaucoma patients was enrolled. All subjects underwent a complete ophthalmologic examination, standard a...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/01.ijg.0000212289.00917.a8
更新日期:2006-12-01 00:00:00
abstract:PURPOSE:The purpose of this study was to perform a comparison of static and dynamic pupillometry measurements in patients with clinically unilateral pseudoexfoliation syndrome (PES) and age-matched controls. METHODS:This prospective cross-sectional study consisted of 38 patients with unilateral PES and 40 control part...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0000000000000953
更新日期:2018-06-01 00:00:00
abstract:PURPOSE:To evaluate the relationship between glaucomatous structural damage assessed by the Cirrus Spectral Domain OCT (SDOCT) and functional loss as measured by standard automated perimetry (SAP). METHODS:Four hundred twenty-two eyes (78 healthy, 210 suspects, 134 glaucomatous) of 250 patients were recruited from the...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0b013e31822af27a
更新日期:2012-01-01 00:00:00
abstract:PURPOSE:To determine the efficacy of selective laser trabeculoplasty (SLT) in a tertiary care referral center. PATIENTS AND METHODS:In this retrospective study of selective laser trabeculoplasty performed by five physicians, 94 eyes from 94 patients were included. A majority (83/92, 90%) underwent 180 degrees selectiv...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/01.ijg.0000176939.43681.c2
更新日期:2005-10-01 00:00:00
abstract:OBJECTIVE:Pachymetry plays a crucial role in the diagnosis and management of glaucoma and corneal diseases. There have been several outbreaks of epidemic ocular infections in ophthalmology clinics worldwide with reports of viral, parasitic, and prion disease. Contact pachymetry is a possible vehicle of transmission due...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0000000000001525
更新日期:2020-08-01 00:00:00
abstract:PURPOSE:The purpose of this study is to determinate the long-term effect of a cycle ergometer sprint training program against heavy and light resistances on baseline intraocular pressure (IOP), and on the acute IOP response to cycling sprints. METHODS:A total 27 physically active males were randomly assigned to a heav...
journal_title:Journal of glaucoma
pub_type: 杂志文章,随机对照试验
doi:10.1097/IJG.0000000000000893
更新日期:2018-04-01 00:00:00
abstract:BACKGROUND:This meta-analysis aims to comprehensively evaluate the association between total homocysteine (tHcy) levels, serum folic acid, vitamin B12, vitamin B6 levels, methylenetetrahydrofolate reductase (MTHFR) C677T genotype, and risk of normal-tension glaucoma (NTG). MATERIALS AND METHODS:A systematic search of ...
journal_title:Journal of glaucoma
pub_type: 杂志文章,meta分析
doi:10.1097/IJG.0000000000000269
更新日期:2016-02-01 00:00:00
abstract:PURPOSE:To evaluate the effect of a single treatment of contact diode laser transscleral cyclophotocoagulation (TSCP) on intraocular pressure (IOP) in patients with refractory glaucoma and perform a historical meta-analysis of the relationship between successful IOP control and various laser parameters. METHODS:Clinic...
journal_title:Journal of glaucoma
pub_type: 杂志文章,meta分析
doi:10.1097/00061198-200208000-00009
更新日期:2002-08-01 00:00:00
abstract:PURPOSE:The most common reason for long-term failure of glaucoma filtering surgery (GFS) is scarring of the external filtering "bleb" tissues. The identification of the factors that mediate this process, as well as the development and initial testing of new therapies to limit scarring is enhanced by the use of appropri...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/01.ijg.0000131482.86547.5a
更新日期:2004-10-01 00:00:00
abstract:PURPOSE:Evaluate the long-term results of the Ahmed glaucoma valve (AGV) surgery in association with bevacizumab (Avastin) in neovascular glaucoma (NVG) patients. DESIGN AND METHODS:This retrospective institutional study reviewed 39 eyes of 34 patients with NVG who underwent AGV implantation. The intravitreal bevacizu...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0000000000000234
更新日期:2015-06-01 00:00:00
abstract:PURPOSE:To report plateau iris configuration (PIC) in subjects who have the long anterior zonule (LAZ) clinical trait. METHODS:Two elderly African American males who exhibited LAZ and had partial appositional angle closure persisting after laser iridotomy were imaged with high-resolution ultrasonography to examine for...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0b013e31815c3b04
更新日期:2008-08-01 00:00:00
abstract::We herein report 2 eyes with significant loss of vision after glaucoma filtering surgery that was accompanied by progressive macular thinning detected on macular optical coherence tomography imaging. The findings provide evidence that progressive retinal ganglion cell loss is one of the causes of visual loss after unc...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0000000000001202
更新日期:2019-06-01 00:00:00
abstract:PURPOSE:To report 2 cases of delayed-onset, bleb-related endophthalmitis induced by Gemella species. METHODS:Interventional case report. RESULTS:Two patients developed bleb-related ocular infection attributable to Gemella haemolysans and Gemella morbillorum after trabeculectomy with adjunctive mitomycin C. Both patie...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0b013e31818c6f07
更新日期:2009-08-01 00:00:00
abstract::PRéCIS:: Micropulse trans-scleral cyclophotocoagulation (TSCPC) is an effective and safe IOP-lowering treatment for patients with primary or secondary glaucoma. PURPOSE:To investigate the 1-year and 2-year effect on intraocular pressure (IOP) and safety profile of micropulse TSCPC in patients with glaucoma. METHODS:...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0000000000001552
更新日期:2020-09-01 00:00:00
abstract:PURPOSE:We assessed vision-related quality of life (VR-QOL) in glaucoma patients and examined the relationship between VR-QOL and indices of visual function and subjective symptoms. PATIENTS AND METHODS:Four hundred seventy-two glaucoma patients completed a questionnaire concerning VR-QOL and subjective symptoms of gl...
journal_title:Journal of glaucoma
pub_type: 杂志文章,多中心研究
doi:10.1097/IJG.0000000000000221
更新日期:2016-03-01 00:00:00
abstract:PURPOSE:The purpose of this study was to compare early postoperative outcomes of patients who underwent Baerveldt 350-mm aqueous drainage device (Abbott Medical Optics Inc., Santa Ana, CA) implantation with and without 7-0 polyglactin (vicryl) suture placement through tube fenestration to serve as a stenting wick. MET...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0000000000001080
更新日期:2018-12-01 00:00:00
abstract:PURPOSE:The study investigated the applicability of the inferior≥superior≥nasal≥temporal neuroretinal rim thickness (ISNT) rule to rim thickness measured using Cirrus high-definition spectral-domain optical coherence tomography (Cirrus HD-OCT) in healthy eyes and eyes with glaucoma. METHODS:Rim thicknesses of 4 quadra...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0000000000000015
更新日期:2015-09-01 00:00:00
abstract:PURPOSE:To assess and compare the impact of medical and surgical glaucoma treatments on patients' health-related Quality of Life (QoL). MATERIALS AND METHODS:We used the 25-question version of the National Eye Institute Visual Functioning Questionnaire (NEI VFQ-25) for this cross-sectional study. Patients were divided...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0b013e31824ceb8b
更新日期:2013-06-01 00:00:00
abstract:PURPOSE:To evaluate anxiety felt by glaucoma patients. PATIENTS AND METHODS:In total, 472 glaucoma patients responded to a questionnaire on anxiety, subjective symptoms, and vision-related quality of life (VR-QOL) associated with glaucoma. Anxiety was evaluated using the State-Trait Anxiety Inventory (STAI), state anx...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0000000000000761
更新日期:2017-11-01 00:00:00
abstract::We report a unique case in which an inadvertent filtering bleb was created after a complicated cataract surgery through an unusual mechanism: an internal fragment of corneal stroma, which was still attached at one end of the clear corneal wound, was pushed into the anterior chamber, became inadvertently entrapped in t...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0b013e3182a07604
更新日期:2013-09-01 00:00:00
abstract:PURPOSE:To report clinical outcomes after pars plana endoscopic cyclophotocoagulation of the ciliary processes and pars plana (ECP-plus), a novel treatment for refractory glaucoma. DESIGN:Retrospective, noncomparative interventional case series. MATERIALS AND METHODS: SETTING:multicenter tertiary referral academic a...
journal_title:Journal of glaucoma
pub_type: 杂志文章,多中心研究
doi:10.1097/IJG.0000000000000278
更新日期:2016-03-01 00:00:00
abstract:PURPOSE:To evaluate morphological features of filtering blebs after trabeculectomy with limbus-based versus fornix-based conjunctival flaps (LBCF and FBCF, respectively) using in vivo confocal microscopy (IVCM) and ultrasound biomicroscopy (UBM). PATIENTS AND METHODS:Seventy-five eyes of 62 patients with glaucoma were...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0b013e3182120a08
更新日期:2012-08-01 00:00:00
abstract:PURPOSE:To evaluate the efficacy and safety of CO2 Laser-assisted Sclerectomy Surgery (CLASS) in primary and pseudoexfoliative open-angle glaucoma. MATERIALS AND METHODS:Single-arm, open-label study included data from 9 medical centers located in 7 countries. Subjects underwent nonpenetrating CLASS procedure with a CO...
journal_title:Journal of glaucoma
pub_type: 杂志文章,多中心研究,随机对照试验
doi:10.1097/IJG.0000000000000437
更新日期:2016-12-01 00:00:00
abstract::Intraocular pressure (IOP) is a dynamic physiologic parameter with regular circadian variations and unpredictable short-term and long-term fluctuations. Current methods of measuring IOP are suboptimal with a typical clinical practice only performing periodic IOP measurements during regular office hours. Diurnal and 24...
journal_title:Journal of glaucoma
pub_type: 杂志文章,评审
doi:10.1097/IJG.0b013e3181862490
更新日期:2009-04-01 00:00:00
abstract:PURPOSE:To investigate the efficacy of argon laser trabeculoplasty (ALT) for the treatment of primary open-angle glaucoma (POAG) and of glaucoma associated with exfoliation syndrome (EXF). METHODS:Review of > 200 charts from patients treated with ALT between 1981 and 1987 identified 66 POAG and 29 EXF eyes that underw...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:
更新日期:1996-10-01 00:00:00
abstract:PURPOSE:The purpose of the study was to investigate the effects of myopic optic disc tilt and rotation on peripapillary retinal nerve fiber layer (RNFL) thickness characteristics measured by Cirrus HD spectral-domain optical coherence tomography (Cirrus HD OCT). METHODS:A total of 93 right eyes from 93 healthy young m...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0b013e3182182567
更新日期:2012-08-01 00:00:00
abstract::PRéCIS:: The potential parameters for differentiating pupillary block (PB) from plateau iris configuration (PIC) on anterior segment optical coherence tomography (ASOCT) are lens/pupil size parameters and angles. Further study is needed to determine a landmark peripheral to the centroid of the iris. PURPOSE:Investiga...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0000000000001664
更新日期:2020-11-01 00:00:00
abstract:PURPOSE:To evaluate the accuracy of intraocular pressure (IOP) measurements obtained with the newly available iCare HOME (RTHOME) rebound tonometer compared with the iCare ONE (RTONE) tonometer and Goldmann applanation tonometry (GAT), and possible correlation with central corneal thickness (CCT). MATERIALS AND METHOD...
journal_title:Journal of glaucoma
pub_type: 杂志文章,随机对照试验
doi:10.1097/IJG.0000000000000390
更新日期:2016-06-01 00:00:00
abstract:PURPOSE:Primary open-angle glaucoma is a significant health-economic burden in both the United States and Europe that is likely to increase. This study compared treatment patterns and cost among patients with primary open-angle glaucoma in these locations. METHODS:Retrospective medical chart reviews were conducted in ...
journal_title:Journal of glaucoma
pub_type: 杂志文章,多中心研究
doi:10.1097/IJG.0b013e3180575202
更新日期:2007-08-01 00:00:00
abstract:PURPOSE:To evaluate the usefulness of the spectral-domain optical coherence tomography (SD OCT)-determined ganglion cell complex thickness to total retinal thickness ratio (G/T ratio) in diagnosing glaucoma. METHODS:A total of 99 eyes with primary open-angle glaucoma and 35 normal eyes were enrolled in the study. SD O...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0b013e31825af58a
更新日期:2013-12-01 00:00:00