Effect of a Short-term Cycle Ergometer Sprint Training Against Heavy and Light Resistances on Intraocular Pressure Responses.

Abstract:

PURPOSE:The purpose of this study is to determinate the long-term effect of a cycle ergometer sprint training program against heavy and light resistances on baseline intraocular pressure (IOP), and on the acute IOP response to cycling sprints. METHODS:A total 27 physically active males were randomly assigned to a heavy loads group (HLG, n=9), low loads group (LLG, n=9), and control group (CG, n=9). Participants performed 12 training sessions during 6 weeks (2 sessions per week), and each training session consisted in performing 8 cycling sprints against either heavy (HLG) or light (LLG) resistances. Before and after intervention, they performed an identical protocol, which consisted in performing maximal cycling sprints against 5 different resistances in random order. In these protocols, IOP was measured before and after each sprint by rebound tonometry. RESULTS:A Bayesian analysis revealed that baseline IOP was reduced in the LLG after the intervention [Bayes factor (BF01)=0.043 and effect size (ES)=1.255; pretest=15.22±0.94 mm Hg and posttest=15.39±1.02 mm Hg], whereas the HLG did not manifest any baseline IOP change (BF01=2.363 and ES=-0.205; pretest=15.28±1.44 mm Hg and posttest=14.17±1.77 mm Hg). The acute IOP response to maximal sprints was modified for the HLG, showing a more stable IOP response with heavier loads (resistance, 4 and 5) after the intervention (BF01<0.01 in both cases, and ESs=1.847 and 1.920, respectively). CONCLUSIONS:A short-term cycle ergometer sprint training impacts long-term IOP depending on the level of resistance imposed, showing that training with low loads permits to reduce baseline IOP, whereas training with heavy loads attenuates the acute IOP changes after sprinting against heavy loads.

journal_name

J Glaucoma

journal_title

Journal of glaucoma

authors

Vera J,Garcia-Ramos A,Redondo B,Cárdenas D,De Moraes CG,Jiménez R

doi

10.1097/IJG.0000000000000893

subject

Has Abstract

pub_date

2018-04-01 00:00:00

pages

315-321

issue

4

eissn

1057-0829

issn

1536-481X

journal_volume

27

pub_type

杂志文章,随机对照试验
  • Serum Bile Acids in Patients With Primary Open-angle Glaucoma.

    abstract:PURPOSE:To measure the serum bile acids (SBA) in patients with primary open-angle glaucoma (POAG) and to compare with nonglaucomatous controls. PATIENTS AND METHODS:A hospital-based case control study of 90 patients above the age of 40 years was conducted. Patients with POAG formed the study group and individuals with...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000000993

    authors: Jacob MM,Pai H V,Gnanaharan J,Kamath S

    更新日期:2018-08-01 00:00:00

  • The effects of the beta-adrenergic-blocking agents, timolol and carteolol, on plasma lipids and lipoproteins in Japanese glaucoma patients.

    abstract:PURPOSE:To determine whether two topical beta-blockers, timolol and carteolol, differently affect plasma lipids and lipoproteins in normolipidemic Japanese patients with glaucoma. PATIENTS AND METHODS:Thirty-three normolipidemic patients with primary open-angle glaucoma or ocular hypertension were randomly allocated t...

    journal_title:Journal of glaucoma

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:

    authors: Yamamoto T,Kitazawa Y,Noma A,Maeda S,Kato A,Ando Y,Ido T,Inazumi K,Hayakawa T,Goto Y,Ichien M

    更新日期:1996-08-01 00:00:00

  • Trabeculectomy Following Failed Ab Interno Gelatin Microstent: Case Series.

    abstract:PURPOSE:The purpose of this study is to describe the outcomes of mitomycin C (MMC)-augmented trabeculectomy performed following a failed MMC-augmented XEN-45 implantation. DESIGN:Retrospective case series. METHODS:All consecutive cases of MMC-augmented trabeculectomy performed after MMC-augmented XEN-45 in the Glauco...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000001000

    authors: Gizzi C,Mohamed-Noriega J,Elkarmouty A,Scott A

    更新日期:2018-10-01 00:00:00

  • Transconjunctival mitomycin C as an adjunct to conventional glaucoma filtration surgery in rabbits.

    abstract:PURPOSE:Subconjunctival mitomycin C has been used in glaucoma filtration surgery with success. A prospective, randomized, masked, placebo-controlled study was performed to evaluate whether single transconjunctival mitomycin C applied either preoperatively or postoperatively would enhance the success of filtration surge...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:

    authors: Buffenn AN,Saetre SB,Higginbotham EJ,Musch DC,Kincaid MC

    更新日期:1997-10-01 00:00:00

  • Retinal nerve fiber layer measurement of the Hong Kong chinese population by optical coherence tomography.

    abstract:PURPOSE:To obtain retinal nerve fiber layer (RNFL) measurements by optical coherence tomography in a local, normal Hong Kong Chinese population and to identify the correlation of the measurement with age cross-sectionally. METHODS:A total of 129 normal Hong Kong Chinese volunteers of different age groups were recruite...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/00061198-200212000-00004

    authors: Mok KH,Lee VW,So KF

    更新日期:2002-12-01 00:00:00

  • Relationship Between Serum Glucose Levels and Intraocular Pressure, a Population-based Cross-sectional Study.

    abstract:PURPOSE:The purpose of this study is to assess the relationship between serum glucose levels and intraocular pressure (IOP) both in subjects with impaired fasting glucose (IFG) as well as in subjects with diabetes mellitus (DM). MATERIALS AND METHODS:Data of a cross-sectional sample of 18,406 subjects who underwent ro...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000000700

    authors: Cohen E,Kramer M,Shochat T,Goldberg E,Krause I

    更新日期:2017-07-01 00:00:00

  • Clinical Presentation and Management Outcomes of Coexistent Congenital Glaucoma and Retinopathy of Prematurity.

    abstract:PURPOSE:The purpose of this study was to report presentation and outcomes of coexisting congenital glaucoma with retinopathy of prematurity (ROP) in "Indian Twin cities ROP study (ITCROPS)." METHODS:Children with ROP and congenital glaucoma were identified from ITCROPS (prospective digital database) between 1997 and 2...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000001124

    authors: Senthil S,Balijepalli P,Garudadri C,Jalali S

    更新日期:2019-01-01 00:00:00

  • Reproducibility of retinal nerve fiber thickness measurements using the test-retest function of spectral OCT/SLO in normal and glaucomatous eyes.

    abstract:PURPOSE:To evaluate the reproducibility of retinal nerve fiber layer (RNFL) thickness measurements in normal and glaucoma patients using the spectral optical coherence tomography (OCT)/scanning laser ophthalmosope (SLO). METHODS:One experienced operator measured peripapillary RNFL thickness 3 times in succession in 98...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0b013e3181ca7cbe

    authors: Lee SH,Kim SH,Kim TW,Park KH,Kim DM

    更新日期:2010-12-01 00:00:00

  • Impact of Phacoemulsification Combined with XEN Gel Stent Implantation on Corneal Endothelial Cell Density: 2-Year Results.

    abstract:INTRODUCTION:Corneal integrity has long been a preoccupation of glaucoma surgeons considering glaucoma drainage device surgery or antimetabolite-enhanced trabeculectomy. Despite having demonstrated a good safety profile and significant intraocular pressure-lowering capacities, the impact of XEN gel stents on endothelia...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000001430

    authors: Gillmann K,Bravetti GE,Rao HL,Mermoud A,Mansouri K

    更新日期:2020-03-01 00:00:00

  • Changes in scanning laser polarimetry before and after laser capsulotomy for posterior capsular opacification.

    abstract:PURPOSE:To investigate changes in scanning laser polarimetry with variable corneal compensation (GDx-VCC) parameters caused by posterior capsular opacification (PCO). METHODS:In this comparative case-control series, 20 eyes due to undergo YAG laser capsulotomy for PCO were recruited. GDx-VCC was performed before and a...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/01.ijg.0000243469.05719.0d

    authors: Brittain CJ,Fong KC,Hull CC,Gillespie IH

    更新日期:2007-01-01 00:00:00

  • Repeatability of pattern electroretinogram measurements using a new paradigm optimized for glaucoma detection.

    abstract:PURPOSE:To determine the within-trial and between-trial repeatability of pattern electroretinogram (PERG) measurements in healthy and patient eyes, using a new clinical instrument, the PERGLA. STUDY DESIGN:In all, 70 eyes of 35 healthy individuals (intraocular pressure <22 mm Hg, healthy optic disc by stereophotograph...

    journal_title:Journal of glaucoma

    pub_type: 临床试验,杂志文章

    doi:10.1097/IJG.0b013e31818c6f44

    authors: Bowd C,Tafreshi A,Vizzeri G,Zangwill LM,Sample PA,Weinreb RN

    更新日期:2009-08-01 00:00:00

  • Effect of 2 Novel Sustained-release Drug Release Systems on Bleb Fibrosis: An In Vivo Trabeculectomy Study in a Rabbit Model.

    abstract:PRECIS:Rabbit model studies suggested better morphology blebs with equal intraocular pressure (IOP) efficacy as a standard mitomycin C (MMC) trabeculectomy using a novel slow-release drug delivery antifibrotic system delivering small quantities of MMC and 5-fluorouracil (5-FU). PURPOSE:To evaluate 2 different concentr...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000001215

    authors: Swann FB,Singh S,Blake D,John V,Le C,Fullerton M,Margo C,Zhang Z,Muddasani N,Wall J,Satija C,Greenberg E,Mancera N,Zurakowski D,Ayyala RS

    更新日期:2019-06-01 00:00:00

  • Results of CO2 Laser-assisted Deep Sclerectomy as Compared With Conventional Deep Sclerectomy.

    abstract:PURPOSE:To evaluate the efficacy of CO2 laser-assisted sclerectomy surgery (CLASS) compared with classic nonpenetrating deep sclerectomy (NPDS) with implant in medically uncontrolled glaucoma patients. MATERIALS AND METHODS:Patients who underwent primary filtration surgery with CO2 laser system at the time interval be...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000000187

    authors: Greifner G,Roy S,Mermoud A

    更新日期:2016-07-01 00:00:00

  • Phacoemulsification and intraocular lens implantation before, during, or after canaloplasty in eyes with open-angle glaucoma: 3-year results.

    abstract:PURPOSE:To report 3-year results evaluating the effect on safety and efficacy of canaloplasty to treat open-angle glaucoma when combined with cataract surgery. PATIENTS AND METHODS:This was a retrospective subset analysis of a prospective, international, multicenter study evaluating 133 eyes of 133 adult, open-angle g...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章,多中心研究

    doi:10.1097/IJG.0b013e318285ff13

    authors: Tetz M,Koerber N,Shingleton BJ,von Wolff K,Bull H,Samuelson TW,Lewis RA

    更新日期:2015-03-01 00:00:00

  • Association of the optic disc structure with the use of antihypertensive medications: the thessaloniki eye study.

    abstract:PURPOSE:To investigate the association of antihypertensive medications with optic disc structure by blood pressure (BP) level, in nonglaucoma subjects. DESIGN:Cross-sectional, population-based study. METHODS:A subset of Thessaloniki Eye Study participants was included in this study. Subjects were interviewed for medi...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0b013e31824d1e12

    authors: Harris A,Topouzis F,Wilson MR,Founti P,Kheradiya NS,Anastasopoulos E,Gong G,Yu F,Jonescu-Cuypers CP,Pappas T,Koskosas A,Coleman AL

    更新日期:2013-09-01 00:00:00

  • Initial Clinical Results of the eyeWatch: a New Adjustable Glaucoma Drainage Device Used in Refractory Glaucoma Surgery.

    abstract::PRéCIS:: In this study, we report clinical results after implantation of an adjustable glaucoma drainage device. The intraocular pressure (IOP) profile was efficiently controlled postoperatively as the resistance to aqueous humor outflow was finely adjusted. PURPOSE:The main purpose of this study was to evaluate the ...

    journal_title:Journal of glaucoma

    pub_type: 临床试验,杂志文章,多中心研究

    doi:10.1097/IJG.0000000000001209

    authors: Roy S,Villamarin A,Stergiopulos C,Bigler S,Guidotti J,Stergiopulos N,Kniestedt C,Mermoud A

    更新日期:2019-05-01 00:00:00

  • Assessing the Methodological Quality of Glaucoma Clinical Practice Guidelines and Their Recommendations on Microinvasive Glaucoma Surgery: A Systematic Review.

    abstract:INTRODUCTION:Clinical practice guidelines (CPG) are regarded by many as critical communications providing guidance within specific medical fields. Over a decade ago, the first microinvasive glaucoma surgical (MIGS) procedures were introduced. Since then, a number of these novel intraocular pressure controlling surgical...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000000820

    authors: Michaelov E,Armstrong JJ,Nguyen M,Instrum B,Lam T,Denstedt J,Hutnik CML

    更新日期:2018-02-01 00:00:00

  • Compliance With Primary Open-angle Glaucoma and Primary Open-angle Glaucoma Suspect Preferred Practice Patterns in a Retail-based Eye Clinic.

    abstract:PURPOSE:To determine the level of adherence to the American Academy of Ophthalmology preferred practice pattern (PPP) guidelines for quality primary open-angle glaucoma (POAG) and POAG suspect (POAGS) care among retail-based optometrists. METHODS:Patients with a diagnosis of POAG or POAGS who participated in a telemed...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000001093

    authors: Stanley J,Huisingh CE,Swain TA,McGwin G Jr,Owsley C,Girkin CA,Rhodes LA

    更新日期:2018-12-01 00:00:00

  • RETeval Portable Electroretinogram Parameters in Different Severity Stages of Glaucoma.

    abstract::PRéCIS:: Four parameters of the noninvasive, portable RETeval electroretinogram (ERG) system were found to correlate with visual field mean deviation and optical coherence tomography (OCT) thickness parameters, and may therefore be suitable for glaucoma detection. PURPOSE:To investigate the RETeval full-field ERG par...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000001509

    authors: Kita Y,Holló G,Saito T,Momota Y,Kita R,Tsunoda K,Hirakata A

    更新日期:2020-07-01 00:00:00

  • Oral fluoroquinolones and risk of glaucoma.

    abstract:OBJECTIVE:To evaluate the risk of developing glaucoma in patients taking systemic fluoroquinolones. METHODS:A case-control study was carried out among a cohort of subjects who had visited an ophthalmologist in the Province of British Columbia, Canada from 2000 to 2007. Cases were identified as those newly diagnosed wi...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0b013e31829463c1

    authors: Yang L,Etminan M,Mikelberg FS

    更新日期:2014-09-01 00:00:00

  • Can Treatment With Citicoline Eyedrops Reduce Progression in Glaucoma? The Results of a Randomized Placebo-controlled Clinical Trial.

    abstract:PRECIS:Citicoline eyedrops in patients with progressing glaucoma. PURPOSE:This study aimed to test whether the additional therapy with citicoline eyedrops to intraocular pressure (IOP)-lowering treatment could slow glaucoma progression in patients with worsening of damage and IOP 18 mm Hg or less. DESIGN:This was a r...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章,多中心研究,随机对照试验

    doi:10.1097/IJG.0000000000001565

    authors: Rossetti L,Iester M,Tranchina L,Ottobelli L,Coco G,Calcatelli E,Ancona C,Cirafici P,Manni G

    更新日期:2020-07-01 00:00:00

  • Vision Loss After Glaucoma Surgery: Progressive Macular Thinning as a Sign of Snuff-Out Phenomenon.

    abstract::We herein report 2 eyes with significant loss of vision after glaucoma filtering surgery that was accompanied by progressive macular thinning detected on macular optical coherence tomography imaging. The findings provide evidence that progressive retinal ganglion cell loss is one of the causes of visual loss after unc...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000001202

    authors: Mohammadzadeh V,Galian K,Martinyan J,Nouri-Mahdavi K

    更新日期:2019-06-01 00:00:00

  • Clinical Efficacy and Safety Outcomes of Micropulse Trans-Scleral Diode Cyclophotocoagulation in Patients with Advanced Glaucoma.

    abstract:PRECIS:Micropulse trans-scleral cyclophotocoagulation is only moderately effective in lowering intraocular pressure and useful as an adjunct procedure to other glaucoma surgeries. There was a small risk of loss of vision, prolonged hypotony and phthisis bulbi. AIMS:To determine the efficacy and safety of a single micr...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000001729

    authors: Lim JYE,Cecilia AM,Lim KAD,Sng C,Loon SC,Lun WXK,Chew TKP,Koh TCV

    更新日期:2020-10-29 00:00:00

  • Correlating RNFL thickness by OCT with perimetric sensitivity in glaucoma patients.

    abstract:PURPOSE:To determine whether a structure-function model developed for normal age-related losses of retinal ganglion cells also models the retinal ganglion cell losses in glaucomatous optic neuropathy. METHODS:The model to relate age-related loss of retinal nerve fiber layer thickness and reduced sensitivity for standa...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0b013e31820bcfbe

    authors: Wheat JL,Rangaswamy NV,Harwerth RS

    更新日期:2012-02-01 00:00:00

  • Imaging visual cortical structure and function in vivo.

    abstract::The recent advent of in vivo two-photon microscopy has allowed the repeat imaging of cortical structures at microscopic resolution within intact brains. Recent data obtained using this imaging technique shows that dendritic spines, the postsynaptic sites of the majority of excitatory synapses in the central nervous sy...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章,评审

    doi:10.1097/IJG.0b013e3182934a30

    authors: Majewska AK

    更新日期:2013-06-01 00:00:00

  • Influence of age-related macular degeneration on macular thickness measurement made with fourier-domain optical coherence tomography.

    abstract:PURPOSE:To evaluate the influence of age-related macular degeneration (AMD) on macular thickness measurement made with Fourier-domain optical coherence tomography (RTVue-OCT) to detect glaucoma. METHODS:: One nonglaucomatous eye of 79 white persons was imaged. This comprised 25 healthy eyes, 19 eyes with early/interme...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0b013e31824083e6

    authors: Garas A,Papp A,Holló G

    更新日期:2013-03-01 00:00:00

  • Structure-function relationships using the Cirrus spectral domain optical coherence tomograph and standard automated perimetry.

    abstract:PURPOSE:To evaluate the relationship between glaucomatous structural damage assessed by the Cirrus Spectral Domain OCT (SDOCT) and functional loss as measured by standard automated perimetry (SAP). METHODS:Four hundred twenty-two eyes (78 healthy, 210 suspects, 134 glaucomatous) of 250 patients were recruited from the...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0b013e31822af27a

    authors: Leite MT,Zangwill LM,Weinreb RN,Rao HL,Alencar LM,Medeiros FA

    更新日期:2012-01-01 00:00:00

  • The effect of myopic optical defocus on the humphrey matrix 30-2 threshold test.

    abstract:PURPOSE:To examine the effect of the myopic optical defocus on the Humphrey Matrix 30-2 test. DESIGN:Prospective, nonrandomized, comparative case series. METHODS:Forty eyes from 40 patients with and without glaucoma underwent 2 consecutive tests using the Humphrey Matrix 30-2 threshold program. The first and second t...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0b013e3181b21ef6

    authors: Kim JH,Kee C

    更新日期:2010-04-01 00:00:00

  • Ahmed Valve Upstream Obstruction Caused by Fibrous Ingrowth: Surgical Approach.

    abstract::Glaucoma secondary to penetrating keratoplasty can be challenging and multiple surgeries may be needed to control the intraocular pressure (IOP), including the use of glaucoma drainage implants. However, late failure of these drainage implant surgery is common, mostly because of excessive scarring or bleb encapsulatio...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000000739

    authors: Medeiros Pinto J,Pinto Ferreira N,Abegão Pinto L

    更新日期:2017-10-01 00:00:00

  • Rasagiline-induced delay of retinal ganglion cell death in experimental glaucoma in rats.

    abstract:PURPOSE:To evaluate the neuroprotective effect of rasagiline (N-propargyl-1 (R)-aminoindan), a selective monoamine oxidase inhibitor, on the survival of retinal ganglion cells (RGCs) in glaucomatous rat eyes. Rasagiline is an FDA approved anti-Parkinson disease drug with neuroprotective capabilities that were shown in ...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0b013e3181e3d101

    authors: Levkovitch-Verbin H,Vander S,Melamed S

    更新日期:2011-06-01 00:00:00