RETeval Portable Electroretinogram Parameters in Different Severity Stages of Glaucoma.

Abstract:

:PRéCIS:: Four parameters of the noninvasive, portable RETeval electroretinogram (ERG) system were found to correlate with visual field mean deviation and optical coherence tomography (OCT) thickness parameters, and may therefore be suitable for glaucoma detection. PURPOSE:To investigate the RETeval full-field ERG parameters for accuracy of separating glaucoma and normal eyes, and correlation with glaucoma severity. PATIENTS AND METHODS:Sixty-two eyes of 62 primary open-angle glaucoma patients [visual field mean deviation (MD) range: -0.44 to -31.15 dB] and 39 eyes of 39 healthy controls underwent one RETeval test (photopic negative response protocol), OCT imaging, and Humphrey 30-2 visual field testing. The glaucoma patients were divided into early (MD≥-6dB, n=33) and moderate-to-advanced (MD<-6 dB, n=29) groups. RESULTS:Significant correlations were found between the best-performing 4 RETeval ERG parameters and the glaucoma severity measures (MD and OCT thickness parameters) for all eyes, all glaucoma eyes and the moderate-to-advanced glaucoma eyes [photopic negative response amplitude at 72 ms (PhNR 72) and MD: r=-0.333, -0.414, and -0.485, respectively, P≤0.008; PhNR 72 and average circumpapillary retinal nerve fiber layer thickness; r=-0.429, -0.450, and -0.542, respectively, P≤0.002]. Except for P-ratio, there was no significant difference between the area under the receiver-operating characteristic (AUROC) values of the OCT thickness parameters (range: 0.927 to 0.938) and the 4 best-performing RETeval ERG parameters (range: 0.839 to 0.905) in the early glaucoma versus control separation. For differentiating the control and the moderate-to-advanced glaucoma eyes, the AUROC values of the 4 best-performing RETeval ERG parameters ranged between 0.924 and 0.958, and no significant difference was found between them and those of the OCT parameters. CONCLUSIONS:The noninvasive, portable RETeval full-field ERG device may be useful to detect glaucoma in moderate-to-advanced stages.

journal_name

J Glaucoma

journal_title

Journal of glaucoma

authors

Kita Y,Holló G,Saito T,Momota Y,Kita R,Tsunoda K,Hirakata A

doi

10.1097/IJG.0000000000001509

subject

Has Abstract

pub_date

2020-07-01 00:00:00

pages

572-580

issue

7

eissn

1057-0829

issn

1536-481X

journal_volume

29

pub_type

杂志文章
  • Progressive High Hypermetropic Shift as a Refractive Surprise Following Glaucoma Filtration Surgery in a Phakic Child With Early-Onset Childhood Glaucoma Associated With Axenfeld-Rieger Anomaly.

    abstract:PURPOSE:We report a case of progressive high hypermetropia following glaucoma filtration surgery in a child with Axenfeld-Rieger syndrome and congenital glaucoma. METHODS/RESULTS:We report a case of a 4-day-old female child presented as a case of Axenfeld-Rieger anomaly with secondary glaucoma in both eyes (OU), who u...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000001283

    authors: Kumar P,Senthil S

    更新日期:2019-08-01 00:00:00

  • Effects of Nonporous Silica Nanoparticles on Human Trabecular Meshwork Cells.

    abstract:PRECIS:Silica nanoparticles (SiNPs), which are potential drug carriers for glaucoma treatment, may induce mild dose-dependent cytotoxicity but not so severe as to compromise a mammalian target of rapamycin (mTOR) pathway in immortalized trabecular meshwork (TM) cells. PURPOSE:Nanoparticle-based ophthalmic drug deliver...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000001709

    authors: Kim M,Park JH,Jeong H,Hong J,Park CY

    更新日期:2021-02-01 00:00:00

  • Clinical Evaluation of Methods to Correct Intraocular Pressure Measurements by the Goldmann Applanation Tonometer, Ocular Response Analyzer, and Corvis ST Tonometer for the Effects of Corneal Stiffness Parameters.

    abstract:PURPOSE:To evaluate the effectiveness of methods to correct intraocular pressure (IOP) measurements obtained using the Goldmann applanation tonometer (GAT), the ocular response analyzer (ORA), and the Corvis ST tonometer (CVS) for the effects of corneal stiffness parameters: central corneal thickness (CCT), corneal cur...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000000359

    authors: Bao F,Huang Z,Huang J,Wang J,Deng M,Li L,Yu A,Wang Q,Elsheikh A

    更新日期:2016-06-01 00:00:00

  • Autologous patch graft in tube shunt surgery.

    abstract:PURPOSE:To evaluate an alternate method of covering the subconjunctival portion of the tube in aqueous shunt surgery. Evidence of tube erosion, graft-related infection, graft melting, or other associated intraocular complications were evaluated. METHODS:A retrospective study of 16 patients (17 eyes) who underwent tube...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:

    authors: Aslanides IM,Spaeth GL,Schmidt CM,Lanzl IM,Gandham SB

    更新日期:1999-10-01 00:00:00

  • Do glaucoma patients use eye drops correctly?

    abstract:PURPOSE:To assess how glaucoma patients use their topical medications. METHODS:142 subjects were tested before an examiner as to how they used their eyedrops. RESULTS:Fifty-six patients (39.4%) used one drop. The number of drops instilled increased with age. The tip of the bottle touched the ocular surface in 78 (54....

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:

    authors: Hosoda M,Yamabayashi S,Furuta M,Tsukahara S

    更新日期:1995-06-01 00:00:00

  • Radial Peripapillary Capillary Density Measurement Using Optical Coherence Tomography Angiography in Early Glaucoma.

    abstract:PURPOSE:The purpose of the study was to compare radial peripapillary capillary (RPC) density between normal subjects and patients with early primary open-angle glaucoma (POAG) using optical coherence tomography angiography (OCT-A). MATERIALS AND METHODS:A total of 24 patients with early POAG and age-matched 52 normal ...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000000649

    authors: Mansoori T,Sivaswamy J,Gamalapati JS,Balakrishna N

    更新日期:2017-05-01 00:00:00

  • Predictive value of early IOP in mitomycin-C augmented trabeculectomy.

    abstract:PURPOSE:To determine whether early intraocular pressure (IOP) after mitomycin-C (MMC) augmented trabeculectomy has any predictive value for intermediate IOP outcome. METHODS:Retrospective case note review. All cases of trabeculectomy using MMC augmentation and at least 1-year follow-up during the study period were inc...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0b013e31805d014a

    authors: Alwitry A,Moodie J,Rotchford A,Abedin A,Patel V,King AJ

    更新日期:2007-10-01 00:00:00

  • Factors That Influence of Trabectome Surgery for Glaucoma Patients.

    abstract:BACKGROUND:The aim of this study was to investigate the factors that influence the outcome of trabectome surgery. METHODS:This was a retrospective nonrandomized study. Seventy-eight glaucoma patients (86 eyes) who underwent trabectome surgeries and were followed up for more than 12 months were included. We classified ...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000000743

    authors: Tojo N,Abe S,Hayashi A

    更新日期:2017-09-01 00:00:00

  • Glycomics, extracellular matrix, and anti-glycan antibodies in exfoliation syndrome.

    abstract::Exfoliation syndrome (XFS) is considered to be a disease of extracellular matrix. Here we review key experimental evidence of aberrations in structure, expression, and function of glycoproteins, complex carbohydrates, and glycosaminoglycans found in extracellular matrix components forming exfoliation material in patie...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章,评审

    doi:10.1097/IJG.0000000000000118

    authors: Huflejt ME,Preiss JS,Thomson JE,Gils IM,Vuskovic MI

    更新日期:2014-10-01 00:00:00

  • Mitomycin C in higher risk trabeculectomy: a prospective comparison of 0.2- to 0.4-mg/cc doses.

    abstract:PURPOSE:This randomized, masked, prospective study was conducted to compare the outcome of filtering surgery using doses of 0.2 mg/cc or 0.4 mg/cc of mitomycin C (MMC) in eyes that were at higher risk from previous conjunctival incisional surgery. METHODS:Eyes of 50 consecutive patients with primary open-angle, pseudo...

    journal_title:Journal of glaucoma

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:

    authors: Sanders SP,Cantor LB,Dobler AA,Hoop JS

    更新日期:1999-06-01 00:00:00

  • Two-year Results After Deep Sclerectomy With Nonabsorbable Uveoscleral Implant (Esnoper-Clip): Surgical Area Analysis Using Anterior Segment Optical Coherence Tomography.

    abstract:PURPOSE:To report 2-year results of deep sclerectomy (DS) with mitomycin C and the uveoscleral implant Esnoper-Clip (AJL Ophthalmics, Álava, Spain), a nonabsorbable hema implant, and the morphologic analysis of the surgical area with anterior segment optical coherence tomography (AS-OCT). MATERIALS AND METHODS:In tota...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000000756

    authors: Romera-Romero P,Loscos-Arenas J,Moll-Udina A,Romanic-Bubalo N,Castellvi-Manent J,Valldeperas X

    更新日期:2017-10-01 00:00:00

  • Dietary ω-3 deficiency and IOP insult are additive risk factors for ganglion cell dysfunction.

    abstract:AIM:Dietary deficiencies in ω-3 polyunsaturated fatty acids are known to effect retinal function including retinal ganglion cell (RGC) activity, which may have implications for glaucoma. In this study we consider retinal function after dietary manipulation and intraocular pressure (IOP) stress designed to compromise RG...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0b013e318237cac7

    authors: Nguyen CT,Vingrys AJ,Bui BV

    更新日期:2013-04-01 00:00:00

  • Near and Distance Stereoacuity in Patients With Primary Open-angle Glaucoma.

    abstract:PURPOSE:To compare near and distance stereoacuity between patients with primary open-angle glaucoma (POAG) and a control group, and to analyze the associations between stereoacuity and POAG severity. METHODS:This cross-sectional study compared near and distance stereoacuity between the POAG and control groups. The dat...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000000963

    authors: Park CK,Kim DW,Lee CK

    更新日期:2018-06-01 00:00:00

  • A comparative study between diode laser cyclophotocoagulation and the Ahmed glaucoma valve implant in neovascular glaucoma: a long-term follow-up.

    abstract:BACKGROUND:To compare the efficacy, safety, and long-term results of intraocular pressure (IOP) reduction by diode laser contact cyclophotocoagulation (DCPC) and Ahmed glaucoma valve (AGV) implant in cases of neovascular glaucoma. METHODS:A total of 66 eyes of 66 patients with neovascular glaucoma were prospectively a...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0b013e31817d235c

    authors: Yildirim N,Yalvac IS,Sahin A,Ozer A,Bozca T

    更新日期:2009-03-01 00:00:00

  • Characteristics of Patients Receiving Treatment Who Deny A Diagnosis Glaucoma or Elevated Intraocular Pressure in the United States.

    abstract:PURPOSE:The purpose of this study was to determine the proportion of patients in the US population who are receiving long-term intraocular pressure (IOP)-lowering medication, but, deny having a diagnosis of glaucoma or elevated IOP. MATERIALS AND METHODS:The National Health and Nutrition Examination Survey (NHANES) is...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000001035

    authors: Lowry EA,Mansberger SL

    更新日期:2018-11-01 00:00:00

  • Evaluation of tonometric correction factors.

    abstract:PURPOSE:To investigate the efficacy of currently available correction factors in correcting intraocular pressure (IOP) measurements for the errors induced by the normal variations in corneal structural characteristics. MATERIALS AND METHODS:Central corneal thickness (CCT) and corneal radius of curvature were measured ...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/01.ijg.0000176940.81799.33

    authors: Gunvant P,O'Leary DJ,Baskaran M,Broadway DC,Watkins RJ,Vijaya L

    更新日期:2005-10-01 00:00:00

  • Technique for removal of malpositioned Ex-PRESS glaucoma device.

    abstract:PURPOSE:To report a simple technique for removal of malpositioned Ex-PRESS miniature glaucoma filtration device. PATIENT AND METHODS:A patient who underwent removal of a malpositioned Ex-PRESS shunt from the right eye with wound revision. RESULTS:Description of step-by-step technique for removal of the Ex-PRESS shunt...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0b013e31827b1540

    authors: Khouri AS,Khan MN,Fechtner RD,Vold SD

    更新日期:2014-09-01 00:00:00

  • Comparison of ICare rebound tonometer with noncontact tonometer in healthy children.

    abstract:PURPOSE:To evaluate the effectiveness of using a noncontact tonometer (NCT) versus a rebound tonometer (ICare) when measuring the intraocular pressure (IOP) in healthy children. DESIGN:Prospective observational study. METHODS:A total of 180 (96 males and 84 females) healthy children, aged 6 months to 15 years, were r...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0b013e3181d12dc4

    authors: Kageyama M,Hirooka K,Baba T,Shiraga F

    更新日期:2011-01-01 00:00:00

  • Scanning Electron Microscopy Evaluation of an EX-PRESS Mini Glaucoma Shunt After Explantation.

    abstract::We report a case of an explanted stainless steel miniature glaucoma drainage device (EX-PRESS) implanted under a scleral flap for pseudoexfoliation open-angle glaucoma surgical treatment. The glaucoma shunt was implanted in a 75-year-old white man with medically refractive glaucoma. Cataract surgery was performed simu...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000000521

    authors: Tognetto D,Cecchini P,D'Aloisio R,Vattovani O,Turco G

    更新日期:2017-01-01 00:00:00

  • Corneal parameters and difference between goldmann applanation tonometry and dynamic contour tonometry in normal eyes.

    abstract:PURPOSE:To compare the difference between 2 methods of measuring the intraocular pressure (IOP), namely, Goldmann applanation tonometry (GAT) and dynamic contour tonometry (DCT) and to study the relationship with the corneal parameters in patients with no glaucoma signs. METHODS:One hundred and eighteen eyes of 118 he...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0b013e31816224bd

    authors: Lanza M,Borrelli M,De Bernardo M,Filosa ML,Rosa N

    更新日期:2008-09-01 00:00:00

  • Influence of total energy delivery on success rate after contact diode laser transscleral cyclophotocoagulation: a retrospective case review and meta-analysis.

    abstract:PURPOSE:To evaluate the effect of a single treatment of contact diode laser transscleral cyclophotocoagulation (TSCP) on intraocular pressure (IOP) in patients with refractory glaucoma and perform a historical meta-analysis of the relationship between successful IOP control and various laser parameters. METHODS:Clinic...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章,meta分析

    doi:10.1097/00061198-200208000-00009

    authors: Hauber FA,Scherer WJ

    更新日期:2002-08-01 00:00:00

  • Early Clinical Results of a Novel Ab Interno Gel Stent for the Surgical Treatment of Open-angle Glaucoma.

    abstract:PURPOSE:To evaluate the intraocular pressure (IOP) lowering effect of the XEN140 microfistula gel stent implant for the surgical treatment of open-angle glaucoma. PATIENTS AND METHODS:Forty-nine eyes of 49 patients with an IOP>18 mm Hg and ≤35 mm Hg were studied in a prospective nonrandomized multicenter cohort trial ...

    journal_title:Journal of glaucoma

    pub_type: 临床试验,杂志文章,多中心研究

    doi:10.1097/IJG.0000000000000352

    authors: Sheybani A,Dick HB,Ahmed II

    更新日期:2016-07-01 00:00:00

  • Diurnal pattern of intraocular pressure is affected by microgravity when measured in space with the pressure phosphene tonometer (PPT).

    abstract:PURPOSE:This study was designed to evaluate the effect of microgravity on the diurnal variation of intraocular pressure (IOP). METHODS:IOPs were measured with the pressure phosphene tonometer in 1 subject (the first Korean astronaut) during spaceflight. IOPs were measured every 3 hours during day time (6 times per day...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0b013e3181f464d2

    authors: Chung KY,Woo SJ,Yi S,Choi GH,Ahn CH,Hur GC,Lim JG,Kim TW

    更新日期:2011-10-01 00:00:00

  • Quality of life of medically versus surgically treated glaucoma patients.

    abstract:PURPOSE:To assess and compare the impact of medical and surgical glaucoma treatments on patients' health-related Quality of Life (QoL). MATERIALS AND METHODS:We used the 25-question version of the National Eye Institute Visual Functioning Questionnaire (NEI VFQ-25) for this cross-sectional study. Patients were divided...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0b013e31824ceb8b

    authors: Guedes RA,Guedes VM,Freitas SM,Chaoubah A

    更新日期:2013-06-01 00:00:00

  • Accuracy of Measurements With the iCare HOME Rebound Tonometer.

    abstract:PURPOSE:To evaluate the accuracy of intraocular pressure (IOP) measurements obtained with the newly available iCare HOME (RTHOME) rebound tonometer compared with the iCare ONE (RTONE) tonometer and Goldmann applanation tonometry (GAT), and possible correlation with central corneal thickness (CCT). MATERIALS AND METHOD...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章,随机对照试验

    doi:10.1097/IJG.0000000000000390

    authors: Termühlen J,Mihailovic N,Alnawaiseh M,Dietlein TS,Rosentreter A

    更新日期:2016-06-01 00:00:00

  • Scanning protocol choice affects optical coherence tomography (OCT-3) measurements.

    abstract:PURPOSE:To determine the optimal OCT-3 scanning protocol. METHODS:Normal subjects, ocular hypertensive, and open-angle glaucoma patients were enrolled. The "fast" RNFL scan protocol consists of 3 consecutive circular scans, each containing 256 A-scans obtained in a single 1.92 second session. The "regular" RNFL scan p...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/00061198-200404000-00010

    authors: Zafar S,Gurses-Ozden R,Makornwattana M,Vessani R,Liebmann JM,Tello C,Ritch R

    更新日期:2004-04-01 00:00:00

  • Scanning laser polarimetry with enhanced corneal compensation in patients with open-angle glaucoma.

    abstract:AIMS:To compare the retinal nerve fiber layer thickness (RNFLT) parameters obtained with newly introduced GDx with enhanced corneal compensation (ECC) and those with GDx with variable corneal compensation (VCC) and to evaluate their reproducibility and the correspondence with visual field damage (VFD) in total or secto...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0b013e318133fb47

    authors: Saito H,Tomidokoro A,Yanagisawa M,Aihara M,Tomita G,Araie M

    更新日期:2008-01-01 00:00:00

  • A randomized clinical trial of selective laser trabeculoplasty versus argon laser trabeculoplasty in patients with pseudoexfoliation.

    abstract:PURPOSE:To evaluate the efficacy of selective laser trabeculoplasty (SLT) versus argon laser trabeculoplasty (ALT) in lowering the intraocular pressure (IOP) in patients with open-angle glaucoma or ocular hypertension secondary to pseudoexfoliation. DESIGN:Multicentered randomized clinical trial. PARTICIPANTS:A total...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章,多中心研究,随机对照试验

    doi:10.1097/IJG.0b013e31829e55e4

    authors: Kent SS,Hutnik CM,Birt CM,Damji KF,Harasymowycz P,Si F,Hodge W,Pan I,Crichton A

    更新日期:2015-06-01 00:00:00

  • Expression and regulation of LOXL1 and elastin-related genes in eyes with exfoliation syndrome.

    abstract::Variants in LOXL1 are significantly associated with exfoliation syndrome (XFS), however the impact of the associated variants on disease development is not yet understood. Initially the associated missense changes, R141L and G153D, were considered to be pathogenic alleles. Flipping of the risk allele in certain popula...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章,评审

    doi:10.1097/IJG.0000000000000124

    authors: Wiggs JL,Pasquale LR

    更新日期:2014-10-01 00:00:00

  • Management of blebitis by members of the American Glaucoma Society: a survey.

    abstract:PURPOSE:To investigate the practice patterns among glaucoma subspecialists in the American Glaucoma Society regarding the management of blebitis. METHODS:An anonymous survey incorporating 14 questions regarding the management of blebitis was mailed to all current active American Glaucoma Society members, including pro...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/00061198-200108000-00015

    authors: Reynolds AC,Skuta GL,Monlux R,Johnson J

    更新日期:2001-08-01 00:00:00