Influence of a dilated pupil on the visual field in glaucoma.

Abstract:

PURPOSE:The author studied the effects of pupillary dilation on perimetry in a group of glaucomatous patients receiving timolol therapy. PATIENTS AND METHODS:A prospective study compared the visual fields of 23 patients with primary open-angle glaucoma of varying severity (mean defect: 3.84; short-term fluctuation: 1.91; pattern standard deviation [SD]: 3.61; corrected pattern SD: 3.12) before and after instillation of phenylephrine 10% using the Octopus 1-2-3 projection perimeter (INTERZEAG AG, Schlieren, Switzerland). RESULTS:The mean defect became impaired by an average of 3.01 (SD +/- 1.52) dB after administration of phenylephrine (p < 0.001). The pattern SD and the corrected pattern SD also became impaired with dilation by 1.51 dB (p < 0.01) and 1.73 dB (p < 0.05), respectively, after dilation. These changes varied across the visual field. The outer zone of the visual field had the greatest impairment after dilation with phenylephrine. CONCLUSIONS:Pupillary dilation in patients with glaucoma produces a nonuniform decrease in threshold sensitivities that is statistically greater on outer zone of the visual field.

journal_name

J Glaucoma

journal_title

Journal of glaucoma

authors

Mendivil A

subject

Has Abstract

pub_date

1997-08-01 00:00:00

pages

217-20

issue

4

eissn

1057-0829

issn

1536-481X

journal_volume

6

pub_type

杂志文章
  • Clinical Efficacy and Safety Outcomes of Micropulse Trans-Scleral Diode Cyclophotocoagulation in Patients with Advanced Glaucoma.

    abstract:PRECIS:Micropulse trans-scleral cyclophotocoagulation is only moderately effective in lowering intraocular pressure and useful as an adjunct procedure to other glaucoma surgeries. There was a small risk of loss of vision, prolonged hypotony and phthisis bulbi. AIMS:To determine the efficacy and safety of a single micr...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000001729

    authors: Lim JYE,Cecilia AM,Lim KAD,Sng C,Loon SC,Lun WXK,Chew TKP,Koh TCV

    更新日期:2020-10-29 00:00:00

  • Risk factors for decompression retinopathy after glaucoma surgery.

    abstract:PURPOSE:To evaluate the risk factors for decompression retinopathy after glaucoma surgery. METHODS:We reviewed the medical records of patients who underwent a trabeculectomy or Ahmed valve implantation and divided them into 2 groups by the development of decompression retinopathy. Various factors were compared between...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0b013e318287aba0

    authors: Jung KI,Lim SA,Lopilly Park HY,Park CK

    更新日期:2014-12-01 00:00:00

  • Provider Agreement in the Assessment of Glaucoma Progression Within a Team Model.

    abstract:PURPOSE:Glaucoma specialists and optometrists who work in a team model at a single institution utilize a common definition of glaucoma progression and treatment algorithm. The purpose of this study was to assess the consistency of agreement in identifying glaucoma progression among glaucoma specialists and optometrists...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000000994

    authors: Shah SM,Choo C,Odden J,Zhao B,Fang C,Schornack M,Stalboerger G,Bennett JR,Khanna CL

    更新日期:2018-08-01 00:00:00

  • Efficacy and safety of inferior 180 degrees goniosynechialysis followed by diode laser peripheral iridoplasty in the treatment of chronic angle-closure glaucoma.

    abstract:PURPOSE:To report the efficacy and safety of inferior 180 degrees goniosynechialysis followed by diode laser peripheral iridoplasty in the treatment of chronic angle-closure glaucoma with total synechial angle closure. METHODS:Five patients with chronic angle-closure glaucoma and total synechial angle closure whose in...

    journal_title:Journal of glaucoma

    pub_type: 临床试验,杂志文章

    doi:10.1097/00061198-200010000-00007

    authors: Lai JS,Tham CC,Chua JK,Lam DS

    更新日期:2000-10-01 00:00:00

  • CO2 laser-assisted sclerectomy surgery, part II: multicenter clinical preliminary study.

    abstract:PURPOSE:To evaluate the efficacy of CO2 laser-assisted sclerectomy surgery (CLASS) in primary and pseudoexfoliative open-angle glaucoma. MATERIALS AND METHODS:Patients for primary filtration surgery underwent CLASS with a CO2 laser system (OT-134-IOPtiMate, IOPtima Ltd., Ramat Gan, Israel). This self-controlled system...

    journal_title:Journal of glaucoma

    pub_type: 临床试验,杂志文章,多中心研究

    doi:10.1097/IJG.0b013e3181f7b14f

    authors: Geffen N,Ton Y,Degani J,Assia EI

    更新日期:2012-03-01 00:00:00

  • Comparison of Anterior Segment Optical Coherence Tomography Bleb Grading, Moorfields Bleb Grading System, and Intraocular Pressure After Trabeculectomy.

    abstract:PURPOSE:To compare a novel anterior segment optical coherence tomography (AS-OCT) bleb grading system with a clinical bleb grading system and both with intraocular pressure (IOP) following trabeculectomy surgery. MATERIALS AND METHODS:A novel AS-OCT grading system based on bleb size and internal reflectivity was devel...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000000636

    authors: Wen JC,Stinnett SS,Asrani S

    更新日期:2017-05-01 00:00:00

  • Recurrent Exposure of XEN Gel Stent Implant and Conjunctival Erosion.

    abstract:PURPOSE:The purpose of this study was to report a case of recurrent conjunctival erosion and XEN Gel Stent exposure after implantation in a primary open-angle glaucoma patient. Minimally invasive glaucoma surgery (MIGS) is a new approach in glaucoma surgery, and there is a lack of published data with regard to the mana...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000001146

    authors: Arnould L,Theillac V,Moran S,Gatinel D,Grise-Dulac A

    更新日期:2019-03-01 00:00:00

  • Intra- and interrater agreement with cumulative defect curves.

    abstract:PURPOSE:To examine intra- and interrater agreement when analyzing cumulative defect curves. Cumulative defect (Bebié) curves provide a graphical representation of the visual field and allow a subjective classification of diffuse and localized loss. METHODS:We used 75 Humphrey 30-2 visual field tests, randomly chosen f...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:

    authors: Chan AB,Chauhan BC,LeBlanc RP,McCormick TA,Shaw AM

    更新日期:1997-04-01 00:00:00

  • Effect of Angle of Incidence on Anterior Chamber Angle Metrics From Optical Coherence Tomography.

    abstract:PURPOSE:To evaluate the local variability of anterior chamber angle (ACA) metrics obtained by time domain (TD) and spectral domain (SD) optical coherence tomography (OCT). MATERIALS AND METHODS:Anterior-segment OCT imaging was performed on 30 normal eyes using Visante TD-OCT and 40 normal eyes using Cirrus SD-OCT. For...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000000169

    authors: Pan X,Maram J,Marion K,Dastiridou A,Zhang ZY,Dominguez-Velasco MF,Sadda SR,Chopra V

    更新日期:2016-01-01 00:00:00

  • Streptococcus intermedius-associated late-onset endophthalmitis after trabeculectomy with adjunctive mitomycin C.

    abstract:PURPOSE:To report a woman with congenital rubella syndrome of delayed-onset, bleb-related endophthalmitis induced by Streptococcus intermedius. METHODS:Interventional case report. RESULTS:A 33-year-old woman who underwent bilateral trabeculectomy with adjunctive mitomycin C, 11 years earlier presented with redness an...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0b013e318170a732

    authors: Mochizuki K,Kumada M,Suemori S,Kawakami H,Sawada A,Yamamoto T,Mikamo H

    更新日期:2009-01-01 00:00:00

  • Laser bleb reduction for bleb dissection with krypton green laser: technique and outcomes.

    abstract:PURPOSE:Lasers have been used to treat dysfunctional blebs, but the laser remodeling of blebs that dissect into the palpebral fissure has not been reported. We describe the unique use of krypton green laser to treat dissected blebs and discuss treatment outcomes. PATIENTS AND METHODS:Retrospective review of consecutiv...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/00061198-200604000-00013

    authors: Welcome BA,Skuta GL,Reynolds AC

    更新日期:2006-04-01 00:00:00

  • Evaluating the Laser Output of the Micropulse P3 Laser Delivery Device Following Repeated Use.

    abstract:PRECIS:Repeated use of the Micropulse P3 (MP3) probe during micropulse transscleral cyclophotocoagulation is associated with an increase in laser output over time. PURPOSE:The purpose of this study was to examine the laser efficacy of the MP3 probe following repeated use. METHODS:This was an observational study carri...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000001277

    authors: Lun K,Suwandono ME,Koh V,Chew PT

    更新日期:2019-08-01 00:00:00

  • Characteristics of pseudoexfoliation in the Thessaloniki Eye Study.

    abstract:PURPOSE:To report on the prevalence of pseudoexfoliation (PEX) and its association with ophthalmic characteristics and systemic diseases in a well-defined population. METHODS:The Thessaloniki Eye study is a cross-sectional population-based study of chronic eye diseases in Thessaloniki, Greece. Participants with PEX we...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0b013e3181d9d8bd

    authors: Anastasopoulos E,Topouzis F,Wilson MR,Harris A,Pappas T,Yu F,Koskosas A,Founti P,Coleman AL

    更新日期:2011-03-01 00:00:00

  • Repeatability and Agreement of Swept Source and Spectral Domain Optical Coherence Tomography Evaluations of Thickness Sectors in Normal Eyes.

    abstract:PURPOSE OF THE STUDY:The purpose of the study was to evaluate the clinical efficacy of swept-source optical coherence tomography (SS-OCT), we compared the intradevice repeatability of thickness measurements obtained using SS-OCT to that of measurements obtained using spectral domain OCT (SD-OCT), and assessed the inter...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000000536

    authors: Lee SY,Bae HW,Kwon HJ,Seong GJ,Kim CY

    更新日期:2017-02-01 00:00:00

  • Comparing spectral-domain optical coherence tomography and standard automated perimetry to diagnose glaucomatous optic neuropathy.

    abstract:PURPOSE:To compare the abilities of standard automated perimetry (SAP) and spectral-domain optical coherence tomography (SDOCT) in diagnosing eyes with glaucomatous optic neuropathy (GON). METHODS:In a cross-sectional study, 280 eyes of 175 subjects referred to tertiary eye care center by general ophthalmologists for ...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000000048

    authors: Rao HL,Yadav RK,Addepalli UK,Begum VU,Senthil S,Choudhari NS,Garudadri CS

    更新日期:2015-06-01 00:00:00

  • The effect of myopic optical defocus on the humphrey matrix 30-2 threshold test.

    abstract:PURPOSE:To examine the effect of the myopic optical defocus on the Humphrey Matrix 30-2 test. DESIGN:Prospective, nonrandomized, comparative case series. METHODS:Forty eyes from 40 patients with and without glaucoma underwent 2 consecutive tests using the Humphrey Matrix 30-2 threshold program. The first and second t...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0b013e3181b21ef6

    authors: Kim JH,Kee C

    更新日期:2010-04-01 00:00:00

  • Erythropoietin: a candidate neuroprotective agent in the treatment of glaucoma.

    abstract::Glaucoma is a progressive optic neuropathy that is the leading cause of irreversible blindness in the world. Although methods to lower intraocular pressure are the mainstay of glaucoma therapy, there are currently no available treatment modalities targeted at neuroprotection. Erythropoietin is a hematopoietic cytokine...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章,评审

    doi:10.1097/IJG.0b013e318156a556

    authors: Tsai JC,Song BJ,Wu L,Forbes M

    更新日期:2007-09-01 00:00:00

  • Mid-term Clinical Results of CO2 Laser-assisted Sclerectomy Surgery (CLASS) for Open-Angle Glaucoma Treatment.

    abstract:PURPOSE:To evaluate the efficacy and safety of CO2 Laser-assisted Sclerectomy Surgery (CLASS) in primary and pseudoexfoliative open-angle glaucoma. MATERIALS AND METHODS:Single-arm, open-label study included data from 9 medical centers located in 7 countries. Subjects underwent nonpenetrating CLASS procedure with a CO...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章,多中心研究,随机对照试验

    doi:10.1097/IJG.0000000000000437

    authors: Geffen N,Mimouni M,Sherwood M,Assia EI

    更新日期:2016-12-01 00:00:00

  • Oxidative stress in primary open-angle glaucoma.

    abstract:PURPOSE:To analyze oxidative stress in primary open-angle glaucoma (POAG). MATERIAL AND METHODS:A case-control study including 90 eyes of 90 patients who needed antiglaucomatous surgery in the course of POAG (glaucoma group, n=50) and from patients who were operated of nonpathologic cataracts (cataract group, n=40). F...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0b013e31815c3a7f

    authors: Zanon-Moreno V,Marco-Ventura P,Lleo-Perez A,Pons-Vazquez S,Garcia-Medina JJ,Vinuesa-Silva I,Moreno-Nadal MA,Pinazo-Duran MD

    更新日期:2008-06-01 00:00:00

  • Ciliary body melanocytoma with anterior segment pigment dispersion and elevated intraocular pressure.

    abstract:PURPOSE:To discuss a case in which melanocytoma of the ciliary body presented with widespread pigment dispersion and elevated intraocular pressure (IOP). METHODS:A 64-year old woman presented with increased IOP and persistent anterior segment inflammation in her right eye. She had undergone a trabeculectomy for uncont...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:

    authors: Bhorade AM,Edward DP,Goldstein DA

    更新日期:1999-04-01 00:00:00

  • Relationship between pattern electroretinogram, standard automated perimetry, and optic nerve structural assessments.

    abstract:PURPOSE:To examine the relationship between retinal ganglion cell function measured using pattern electroretinogram optimized for glaucoma screening (PERGLA), retinal nerve fiber layer (RNFL) thickness, and optic nerve head topography. METHODS:Twenty-nine normal, 28 glaucoma, and 37 glaucoma suspect volunteers were en...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0b013e31819afb5c

    authors: Sehi M,Pinzon-Plazas M,Feuer WJ,Greenfield DS

    更新日期:2009-10-01 00:00:00

  • Macular retinal thickness in glaucoma with superior or inferior visual hemifield defects.

    abstract:PURPOSE:To elucidate the relationship between macular retinal thickness and corresponding superior or inferior visual hemifield defects in glaucoma patients. METHODS:Thirty-nine eyes of 39 patients with open-angle glaucoma showed superior or inferior hemifield defects (superior hemifield defects, 27 eyes; inferior hem...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0b013e318225472a

    authors: Inuzuka H,Kawase K,Sawada A,Aoyama Y,Yamamoto T

    更新日期:2013-01-01 00:00:00

  • Needle revision of filtering blebs.

    abstract::The modern version of trabeculectomy is associated with a very high success rate. As time progresses after surgery, failure of filtration, however, is common, as are problems with filtering blebs such as leaks and dysesthesia. Needle revision of filtering blebs is a useful adjunct to failed, failing, leaking, or dyses...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章,评审

    doi:10.1097/IJG.0b013e318181283e

    authors: Feldman RM,Tabet RR

    更新日期:2008-10-01 00:00:00

  • Ahmed glaucoma valve surgical outcomes in eyes with and without silicone oil endotamponade.

    abstract:PURPOSE:To compare the results of Ahmed glaucoma valve (AGV) implantation in eyes containing silicone oil to those without silicone oil. METHODS:This was a multicenter, retrospective, comparative study of 94 eyes in 94 patients with mean follow-up of 2 years, comparing surgical outcomes in eyes with silicone oil (N=47...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0b013e318182ede3

    authors: Ishida K,Ahmed II,Netland PA

    更新日期:2009-04-01 00:00:00

  • Peripapillary focal retinal arteriolar narrowing in open angle glaucoma.

    abstract:PURPOSE:Optic disc photographs of 750 patients attending a glaucoma practice were examined to identify focal peripapillary arteriolar narrowing. METHODS:A subgroup of 110 of these patients' photographs, who had also had finger circulation tested for vasospasm to cold, were divided into patients with peripapillary foca...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:

    authors: Rankin SJ,Drance SM

    更新日期:1996-02-01 00:00:00

  • Fluctuation of Bacteria on Bleb Surface After Trabeculectomy With Adjunctive Mitomycin C.

    abstract:PURPOSE:To determine whether the bacterial and floral patterns on the bleb surface are affected by the season in eyes that had undergone trabeculectomy with adjunctive mitomycin C. PATIENTS AND METHODS:Forty-four glaucoma patients who had an avascular or a hypovascular cystic filtering bleb were studied. Swabs of the ...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000000305

    authors: Takahashi N,Sawada A,Mochizuki K,Katada T,Yamamoto T

    更新日期:2016-05-01 00:00:00

  • Reversal of disc cupping after intraocular pressure reduction in topographic image series.

    abstract:PURPOSE:To identify and characterize 'reversal' of optic nerve cupping following intraocular pressure (IOP) lowering in scanning laser tomography (SLT) longitudinal image series. METHODS:Modification was made to a previously described analytical approach to longitudinally study putatively increased rim area following ...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/01.ijg.0000133151.82804.e3

    authors: Tan JC,Hitchings RA

    更新日期:2004-10-01 00:00:00

  • Progression of Parapapillary Choroidal Microvascular Dropout After Disc Hemorrhage in Glaucoma Patients: 2 Case Reports.

    abstract:PURPOSE:Microvasculature dropout (MvD) is a novel finding seen in optical coherence tomography angiography (OCTA), which is characterized by a localized dehiscence of the choriocapillaris in the parapapillary atrophy area. Disc hemorrhage (DH) is an important factor often associated with the development and especially ...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000001688

    authors: Lee JS,Lee WJ,Lim HW,Seong M

    更新日期:2021-01-01 00:00:00

  • Effect of flunarizine, a calcium channel blocker, on intraocular pressure and aqueous humor dynamics in monkeys.

    abstract:PURPOSE:To evaluate the effects of flunarizine, a nonselective calcium channel blocker, on intraocular pressure (IOP) in monkeys with laser-induced unilateral glaucoma and on aqueous humor dynamics in normal monkeys. METHODS:The IOP was measured before and hourly for 6 hours after single-dose administration of 0.5%, 1...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0b013e318133a845

    authors: Wang RF,Gagliuso DJ,Podos SM

    更新日期:2008-01-01 00:00:00

  • Corneal parameters and difference between goldmann applanation tonometry and dynamic contour tonometry in normal eyes.

    abstract:PURPOSE:To compare the difference between 2 methods of measuring the intraocular pressure (IOP), namely, Goldmann applanation tonometry (GAT) and dynamic contour tonometry (DCT) and to study the relationship with the corneal parameters in patients with no glaucoma signs. METHODS:One hundred and eighteen eyes of 118 he...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0b013e31816224bd

    authors: Lanza M,Borrelli M,De Bernardo M,Filosa ML,Rosa N

    更新日期:2008-09-01 00:00:00