A review: "a comparison of treated and untreated glaucoma suspects" (4).

Abstract:

OBJECTIVES:This study was conducted to evaluate the effect of long-term intraocular pressure reduction with timolol on the incidence of glaucomatous visual field defects and optic nerve cupping in individuals with ocular hypertension and to compare this incidence with that of a similar group on no treatment.

journal_name

J Glaucoma

journal_title

Journal of glaucoma

authors

Vogel R

subject

Has Abstract

pub_date

1993-01-01 00:00:00

pages

8-9

eissn

1057-0829

issn

1536-481X

pii

00061198-199300021-00005

journal_volume

2 Suppl A

pub_type

杂志文章
  • The Prevalence of Pseudoexfoliation and the Long-term Changes in Eyes With Pseudoexfoliation in a South Indian Population.

    abstract:PURPOSE:To report the prevalence, long-term changes and associated factors for pseudoexfoliation (PEX) in a population aged 40 years and above from rural and urban south India. MATERIALS AND METHODS:At baseline (the Chennai Glaucoma Study), 7774 subjects were examined. After 6 years, as a part of the incidence study, ...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章,多中心研究

    doi:10.1097/IJG.0000000000000276

    authors: Vijaya L,Asokan R,Panday M,Choudhari NS,Sathyamangalam RV,Velumuri L,George R

    更新日期:2016-06-01 00:00:00

  • Correlating RNFL thickness by OCT with perimetric sensitivity in glaucoma patients.

    abstract:PURPOSE:To determine whether a structure-function model developed for normal age-related losses of retinal ganglion cells also models the retinal ganglion cell losses in glaucomatous optic neuropathy. METHODS:The model to relate age-related loss of retinal nerve fiber layer thickness and reduced sensitivity for standa...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0b013e31820bcfbe

    authors: Wheat JL,Rangaswamy NV,Harwerth RS

    更新日期:2012-02-01 00:00:00

  • Progression of Parapapillary Choroidal Microvascular Dropout After Disc Hemorrhage in Glaucoma Patients: 2 Case Reports.

    abstract:PURPOSE:Microvasculature dropout (MvD) is a novel finding seen in optical coherence tomography angiography (OCTA), which is characterized by a localized dehiscence of the choriocapillaris in the parapapillary atrophy area. Disc hemorrhage (DH) is an important factor often associated with the development and especially ...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000001688

    authors: Lee JS,Lee WJ,Lim HW,Seong M

    更新日期:2021-01-01 00:00:00

  • Latanoprost-induced iris heterochromia and open-angle glaucoma: a clinicopathologic report.

    abstract:PURPOSE:To report the histopathologic and immunohistochemical findings from the iridectomy specimen of a patient with acquired unilateral iris heterochromia due to latanoprost. PATIENT AND METHODS:A 45-year-old woman with open-angle glaucoma and unilateral iris heterochromia was evaluated for uncontrolled intraocular ...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/00061198-200110000-00009

    authors: Tsai JC,Sivak-Callcott JA,Haik BG,Zhang J,McLean IW

    更新日期:2001-10-01 00:00:00

  • Effectiveness and Tolerance of beta-Blocker/Pilocarpine Combination Eye Drops in Primary Open-Angle Glaucoma and High Intraocular Pressure.

    abstract:OBJECTIVE AND METHOD:A randomized, double-blind, parallel-group study compared the effectiveness and tolerability of three treatments for glaucoma: 2% carteolol/2% pilocarpine fixed-ratio combination (CBS 341A) twice a day, versus a 0.5% timolol/2% pilocarpine fixed combination twice a day versus 2% carteolol twice a d...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:

    authors: Demailly P,Allaire C,Bron V,Trinquand C

    更新日期:1995-08-01 00:00:00

  • Scanning Electron Microscopy Evaluation of an EX-PRESS Mini Glaucoma Shunt After Explantation.

    abstract::We report a case of an explanted stainless steel miniature glaucoma drainage device (EX-PRESS) implanted under a scleral flap for pseudoexfoliation open-angle glaucoma surgical treatment. The glaucoma shunt was implanted in a 75-year-old white man with medically refractive glaucoma. Cataract surgery was performed simu...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000000521

    authors: Tognetto D,Cecchini P,D'Aloisio R,Vattovani O,Turco G

    更新日期:2017-01-01 00:00:00

  • Glycerin-preserved Human-donor Corneoscleral Patch Grafts for Glaucoma Drainage Devices.

    abstract:PRECIS:Glycerin-preserved, human-donor, corneoscleral patch grafts are effective and safe for glaucoma drainage device (GDD) implantation, and they are comparable to previously reported materials. It can be preserved with the sterile technique for up to 12 months. PURPOSE:To evaluate the efficacy and safety of glyceri...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000001610

    authors: Kitnarong N,Srikulsasitorn B,Aurboonsong T

    更新日期:2020-11-01 00:00:00

  • Ahmed Valve Upstream Obstruction Caused by Fibrous Ingrowth: Surgical Approach.

    abstract::Glaucoma secondary to penetrating keratoplasty can be challenging and multiple surgeries may be needed to control the intraocular pressure (IOP), including the use of glaucoma drainage implants. However, late failure of these drainage implant surgery is common, mostly because of excessive scarring or bleb encapsulatio...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000000739

    authors: Medeiros Pinto J,Pinto Ferreira N,Abegão Pinto L

    更新日期:2017-10-01 00:00:00

  • Rate of response to latanoprost or timolol in patients with ocular hypertension or glaucoma.

    abstract:PURPOSE:This study determined the rate of response to latanoprost compared with timolol in patients with glaucoma or ocular hypertension, whether some patients convert from non-responders to responders after more prolonged therapy, and whether this conversion represents a delayed response or random fluctuation. METHOD...

    journal_title:Journal of glaucoma

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1097/00061198-200312000-00004

    authors: Camras CB,Hedman K,US Latanoprost Study Group.

    更新日期:2003-12-01 00:00:00

  • Characteristics of patients who dropout from a glaucoma clinic.

    abstract:PURPOSE:To find the dropout rate and identify the clinical characteristics of patients who drop out in the first year of follow-up from a glaucoma clinic. DESIGN:Descriptive hospital-based study at a tertiary hospital eye department. METHODS:Clinical characteristics of consecutive patients newly diagnosed with glauco...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0b013e31815768b3

    authors: Ashaye AO,Adeoye AO

    更新日期:2008-04-01 00:00:00

  • Continuous monitoring of intraocular pressure: rationale and progress toward a clinical device.

    abstract::Intraocular pressure (IOP) is a dynamic physiologic parameter with regular circadian variations and unpredictable short-term and long-term fluctuations. Current methods of measuring IOP are suboptimal with a typical clinical practice only performing periodic IOP measurements during regular office hours. Diurnal and 24...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章,评审

    doi:10.1097/IJG.0b013e3181862490

    authors: Sit AJ

    更新日期:2009-04-01 00:00:00

  • The Italian version of the Glaucoma Symptom Scale Questionnaire: translation, validation, and reliability.

    abstract:PURPOSE:To validate the Italian version of the Glaucoma Symptom Scale (GSS) Questionnaire and its symptoms and function subscales. METHODS:This transversal validation study enrolled nonhospitalized patients with glaucoma, and a reference sample of patients without eye diseases. Eligible participants had to be cognitiv...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0b013e318225406c

    authors: Rossi GC,Pasinetti GM,Scudeller L,Milano G,Mazzone A,Raimondi M,Bordin M,Lanteri S,Bianchi PE

    更新日期:2013-01-01 00:00:00

  • Adherence to Follow-up Recommendations Among Individuals in the Philadelphia Glaucoma Detection and Treatment Project.

    abstract:PURPOSE:To evaluate rates of adherence to free follow-up eye exam appointments among participants in the Philadelphia Glaucoma Detection and Treatment Project. PATIENTS AND METHODS:Ophthalmologists and testing equipment were brought directly to participants at risk for glaucoma at 43 community sites in Philadelphia. T...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章,多中心研究

    doi:10.1097/IJG.0000000000000716

    authors: Hark LA,Leiby BE,Waisbourd M,Myers JS,Fudemberg SJ,Mantravadi AV,Dai Y,Gilligan JP,Resende AF,Katz LJ

    更新日期:2017-08-01 00:00:00

  • Acetazolamide-related life-threatening hypophosphatemia in a glaucoma patient.

    abstract::Acetazolamide-related hypophosphatemia leading to cardiac arrest is extremely rare. Herein we report a 78-year-old female glaucoma patient who developed general weakness and acute respiratory failure, followed by cardiac arrest 1 day after taking acetazolamide. The patient was successfully weaned from the ventilator a...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000000185

    authors: Hu CY,Lee BJ,Cheng HF,Wang CY

    更新日期:2015-04-01 00:00:00

  • Association of Intraocular Pressure Changes With Right Ventricular Diameter and Brain Natriuretic Peptide in a Case of Pulmonary Arterial Hypertension.

    abstract:PURPOSE:To report a case of secondary pulmonary arterial hypertension (PAH) and the relationship of intraocular pressure (IOP) change with right ventricular diameter (RVD) and brain natriuretic peptide (BNP). METHODS:Case report. PATIENT:A 22-year-old woman with dilated and congested conjunctival and episcleral veins...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000000371

    authors: Sato C,Kaneko H,Kondo T,Takayama K,Yasuda S,Terasaki H

    更新日期:2016-03-01 00:00:00

  • Using Anterior Segment Optical Coherence Tomography (ASOCT) Parameters to Determine Pupillary Block Versus Plateau Iris Configuration.

    abstract::PRéCIS:: The potential parameters for differentiating pupillary block (PB) from plateau iris configuration (PIC) on anterior segment optical coherence tomography (ASOCT) are lens/pupil size parameters and angles. Further study is needed to determine a landmark peripheral to the centroid of the iris. PURPOSE:Investiga...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000001664

    authors: Crowell EL,Chuang AZ,Bell NP,Blieden LS,Feldman RM

    更新日期:2020-11-01 00:00:00

  • Outcomes of Micropulse Transscleral Cyclophotocoagulation in Uncontrolled Glaucoma Patients.

    abstract:PURPOSE:This study aimed at evaluating the intermediate-term efficacy and safety of micropulse transscleral cyclophotocoagulation (MP-TSCPC) in cases of uncontrolled glaucoma. METHODS:Patients with moderate to advanced glaucoma and uncontrolled intraocular pressure (IOP) despite maximally tolerable antiglaucoma medica...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000001174

    authors: Zaarour K,Abdelmassih Y,Arej N,Cherfan G,Tomey KF,Khoueir Z

    更新日期:2019-03-01 00:00:00

  • Outcomes of surgical bleb revision for late-onset bleb leaks after trabeculectomy.

    abstract:PURPOSE:To describe the outcome of surgical bleb revision for late-onset bleb leaks after trabeculectomy. PATIENTS AND METHODS:Appropriate cases were identified. Qualified and complete success required intraocular pressure of 21 mm Hg or less with and without glaucoma medication use, respectively. Bleb survival was de...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0b013e31821e83e6

    authors: Lin AP,Chung JE,Zhang KS,Chang MM,Orengo-Nania S,Gross RL,Chang PT

    更新日期:2013-01-01 00:00:00

  • Tube Obstruction of a Non valved Glaucoma Drainage Device by a Dislocated Soemmering's Ring.

    abstract::We report a case of tube obstruction of a non valved glaucoma drainage device (Aurolab Aqueous Drainage Implant; AADI) with a dislocated Soemmering's ring leading to a postoperative intraocular pressure (IOP) spike after an initial IOP reduction. A 24 year old male with bilateral aphakia, bilateral secondary glaucoma ...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000001760

    authors: Khurana M,Sudhir RR,Rishi E,Sakaria P,Vijaya L

    更新日期:2020-12-17 00:00:00

  • Stratus OCT in dominant optic atrophy: features differentiating it from glaucoma.

    abstract:PURPOSE:To describe the Stratus optical coherence tomography (OCT) retinal nerve fiber layer (RNFL) thickness profile of dominant optic atrophy (DOA), to differentiate it from that of glaucoma. METHODS:RNFL thickness was measured using Stratus OCT in 32 eyes of 16 DOA patients. RESULTS:The temporal-most clock hour me...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0b013e31804d23aa

    authors: Kim TW,Hwang JM

    更新日期:2007-12-01 00:00:00

  • Retinal nerve fiber layer analysis of cupping in children born prematurely.

    abstract:PURPOSE:The aim of this study was to quantitatively study the retinal nerve fiber layer (RNFL) thickness in children born prematurely with isolated optic nerve cupping. PATIENTS AND METHODS:Six otherwise healthy premature children with clinical evidence of increased cup to disc ratios were enrolled in this observation...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000000006

    authors: Glass LR,Cioffi GA,Blumberg DM

    更新日期:2014-01-01 00:00:00

  • Repeatability of pattern electroretinogram measurements using a new paradigm optimized for glaucoma detection.

    abstract:PURPOSE:To determine the within-trial and between-trial repeatability of pattern electroretinogram (PERG) measurements in healthy and patient eyes, using a new clinical instrument, the PERGLA. STUDY DESIGN:In all, 70 eyes of 35 healthy individuals (intraocular pressure <22 mm Hg, healthy optic disc by stereophotograph...

    journal_title:Journal of glaucoma

    pub_type: 临床试验,杂志文章

    doi:10.1097/IJG.0b013e31818c6f44

    authors: Bowd C,Tafreshi A,Vizzeri G,Zangwill LM,Sample PA,Weinreb RN

    更新日期:2009-08-01 00:00:00

  • Characteristics of pseudoexfoliation in the Thessaloniki Eye Study.

    abstract:PURPOSE:To report on the prevalence of pseudoexfoliation (PEX) and its association with ophthalmic characteristics and systemic diseases in a well-defined population. METHODS:The Thessaloniki Eye study is a cross-sectional population-based study of chronic eye diseases in Thessaloniki, Greece. Participants with PEX we...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0b013e3181d9d8bd

    authors: Anastasopoulos E,Topouzis F,Wilson MR,Harris A,Pappas T,Yu F,Koskosas A,Founti P,Coleman AL

    更新日期:2011-03-01 00:00:00

  • Four Questions for Every Clinician Diagnosing and Monitoring Glaucoma.

    abstract::We pose 4 questions for the clinician diagnosing and monitoring glaucoma, and supply evidence-based answers. The first question is: "When do you perform a 10-2 (2-degree grid) visual field (VF) test?" We argue the best answer is: anyone you would do, or have done, a 24-2 (6-degree grid) VF on should have both a 24-2 a...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000001010

    authors: Hood DC,De Moraes CG

    更新日期:2018-08-01 00:00:00

  • CO2 laser-assisted sclerectomy surgery, part II: multicenter clinical preliminary study.

    abstract:PURPOSE:To evaluate the efficacy of CO2 laser-assisted sclerectomy surgery (CLASS) in primary and pseudoexfoliative open-angle glaucoma. MATERIALS AND METHODS:Patients for primary filtration surgery underwent CLASS with a CO2 laser system (OT-134-IOPtiMate, IOPtima Ltd., Ramat Gan, Israel). This self-controlled system...

    journal_title:Journal of glaucoma

    pub_type: 临床试验,杂志文章,多中心研究

    doi:10.1097/IJG.0b013e3181f7b14f

    authors: Geffen N,Ton Y,Degani J,Assia EI

    更新日期:2012-03-01 00:00:00

  • Determinants of adherence to glaucoma medical therapy in a long-term patient population.

    abstract:PURPOSE:Estimate patient adherence to glaucoma medications and identify potential determinants of nonadherence. DESIGN:Descriptive study. METHODS:Two hundred patients with open angle glaucoma, ocular hypertension, or glaucoma suspects were interviewed regarding their glaucoma and its treatment and their charts were r...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0b013e3181815421

    authors: Djafari F,Lesk MR,Harasymowycz PJ,Desjardins D,Lachaine J

    更新日期:2009-03-01 00:00:00

  • Proline-assisted Tube Insertion Through Sulcus in Ahmed Valve.

    abstract::To prevent corneal endothelial cell loss, ciliary sulcus tube insertion is preferred for the pseudophakic eye. However, we sometimes encounter technical difficulties when inserting the tube through the sulcus. Even in cases in which we are able to insert a 23-G needle through the sulcus into the space between the iris...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000001602

    authors: Kasuga T,Asaoka S,Asada Y,Iwamoto S,Hirakata T,Honda R,Ohta T,Matsuda A

    更新日期:2020-09-01 00:00:00

  • Interobserver agreement of Heidelberg retina tomograph parameters.

    abstract:PURPOSE:To measure the interobserver agreement of Heidelberg Retina Tomograph (HRT; Heidelberg Engineering, Heidelberg, Germany) parameters as a result of different observers' contour line placement. METHODS:The optic nerve heads of 50 patients with glaucoma were imaged with the HRT. Five observers traced each disc ma...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:

    authors: Hatch WV,Flanagan JG,Williams-Lyn DE,Buys YM,Farra T,Trope GE

    更新日期:1999-08-01 00:00:00

  • "Pseudophakic Reverse Pupillary Block" Following Yamane Technique Scleral-fixated Intraocular Lens.

    abstract:PURPOSE:The authors report a rare complication of "pseudophakic reverse pupillary block" after a secondary, scleral-fixated intraocular lens implantation using the Yamane technique. METHODS/RESULTS:A 52-year-old male patient was referred for uncontrolled intraocular pressure (IOP) despite 3 topical antiglaucoma medica...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000001538

    authors: Bharathi M,Balakrishnan D,Senthil S

    更新日期:2020-07-01 00:00:00

  • Comparing the Performance of Compass Perimetry With Humphrey Field Analyzer in Eyes With Glaucoma.

    abstract:PURPOSE:To evaluate the reliability indices [fixation losses, false negative response rates (FN) and false positive response rates] and threshold sensitivities obtained from glaucoma patients with a Compass perimeter and to compare the same with the Humphrey field analyzer (HFA). METHODS:In a cross-sectional study, 97...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000000609

    authors: Rao HL,Raveendran S,James V,Dasari S,Palakurthy M,Reddy HB,Pradhan ZS,Rao DA,Puttaiah NK,Devi S

    更新日期:2017-03-01 00:00:00