:We pose 4 questions for the clinician diagnosing and monitoring glaucoma, and supply evidence-based answers. The first question is: "When do you perform a 10-2 (2-degree grid) visual field (VF) test?" We argue the best answer is: anyone you would do, or have done, a 24-2 (6-degree grid) VF on should have both a 24-2 and a 10-2 VF within the first 2 visits. Second, "When do you perform an optical coherence tomography (OCT) scan of the macula?" We argue that, if you are performing an OCT test, then it should include both the macula and disc, either as a single scan or as 2 scans, one centered on the macula and the other on the disc. Third, "How do you know if the VF and OCT tests agree?" The poor answer is, "I use summary statistics such as 24-2 mean deviation and global or quadrant average of retinal nerve fiber layer (RNFL) thickness." It is much better to topographically compare abnormal regions on the OCT to abnormal regions on the VF. Finally, the fourth question is: "When do you look at OCT images?" We argue that, at a minimum, the clinician should be directly examining an image of the circumpapillary RNFL, and this image should be sufficiently large and with sufficient resolution so that local damage can be seen, and the segmentation evaluated.
journal_name
J Glaucomajournal_title
Journal of glaucomaauthors
Hood DC,De Moraes CGdoi
10.1097/IJG.0000000000001010subject
Has Abstractpub_date
2018-08-01 00:00:00pages
657-664issue
8eissn
1057-0829issn
1536-481Xjournal_volume
27pub_type
杂志文章abstract:PURPOSE:To investigate the relationship between the peripapillary retinal nerve fiber layer (RNFL) thickness, as measured by Stratus time domain optical coherence tomography (OCT) (Stratus OCT) and Cirrus spectral domain OCT (Cirrus HD-OCT), and the severity indices of the visual field (VF) defects in glaucoma patients...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0b013e3181efb371
更新日期:2011-08-01 00:00:00
abstract:PURPOSE:To evaluate the efficacy and safety of a tube fenestration stented with a 10-0 polyglactin suture for controlling early postoperative intraocular pressure (IOP) after Baerveldt glaucoma implant (BGI) surgery. METHODS:The medical records of 110 patients (119 eyes) who underwent BGI surgery with a tube fenestrat...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0000000000000885
更新日期:2018-03-01 00:00:00
abstract::A 51-year-old white man presented with multiple episodes of transient painless unilateral vision loss precipitated by sexual intercourse. Examination was significant for closed angles bilaterally. His visual symptoms completely resolved following treatment with laser peripheral iridotomies. ...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0000000000000165
更新日期:2016-01-01 00:00:00
abstract:INTRODUCTION:Corneal integrity has long been a preoccupation of glaucoma surgeons considering glaucoma drainage device surgery or antimetabolite-enhanced trabeculectomy. Despite having demonstrated a good safety profile and significant intraocular pressure-lowering capacities, the impact of XEN gel stents on endothelia...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0000000000001430
更新日期:2020-03-01 00:00:00
abstract::To prevent corneal endothelial cell loss, ciliary sulcus tube insertion is preferred for the pseudophakic eye. However, we sometimes encounter technical difficulties when inserting the tube through the sulcus. Even in cases in which we are able to insert a 23-G needle through the sulcus into the space between the iris...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0000000000001602
更新日期:2020-09-01 00:00:00
abstract:PURPOSE:To develop a descriptive system for a glaucoma-specific preference-based health-related quality of life (HRQoL) instrument: the Health Utility for Glaucoma (HUG-5). METHODS:The descriptive system was developed in 2 stages: item identification and item selection. A systematic literature review of HRQoL assessme...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0000000000000984
更新日期:2018-07-01 00:00:00
abstract:OBJECTIVE AND METHOD:A randomized, double-blind, parallel-group study compared the effectiveness and tolerability of three treatments for glaucoma: 2% carteolol/2% pilocarpine fixed-ratio combination (CBS 341A) twice a day, versus a 0.5% timolol/2% pilocarpine fixed combination twice a day versus 2% carteolol twice a d...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:
更新日期:1995-08-01 00:00:00
abstract:PURPOSE:To describe findings and utility of optical coherence tomography angiography (OCTA) in optic nerve head drusen (ONHD). OBSERVATIONS:A 57-year-old white man presented with a decrease in contrast sensitivity of the inferior visual field in both eyes. Clinical examination, visual fields, optical coherence tomogra...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0000000000000730
更新日期:2017-09-01 00:00:00
abstract:PURPOSE:To determine whether the bacterial and floral patterns on the bleb surface are affected by the season in eyes that had undergone trabeculectomy with adjunctive mitomycin C. PATIENTS AND METHODS:Forty-four glaucoma patients who had an avascular or a hypovascular cystic filtering bleb were studied. Swabs of the ...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0000000000000305
更新日期:2016-05-01 00:00:00
abstract:PURPOSE:(1) To investigate the reference value of peak-trough difference in circadian rhythm of intraocular pressure (IOP) in habitual position and (2) to compare the IOP parameters among 3 age groups. MATERIALS AND METHODS:Habitual IOP of healthy subjects sampled from the population in the Handan Eye Study was measur...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0000000000000351
更新日期:2016-07-01 00:00:00
abstract:PURPOSE:To examine the relationship between retinal ganglion cell function measured using pattern electroretinogram optimized for glaucoma screening (PERGLA), retinal nerve fiber layer (RNFL) thickness, and optic nerve head topography. METHODS:Twenty-nine normal, 28 glaucoma, and 37 glaucoma suspect volunteers were en...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0b013e31819afb5c
更新日期:2009-10-01 00:00:00
abstract:PURPOSE:The goal of this study was to identify the early postoperative intraocular pressure (IOP) that predicts low pressure control after a trabeculectomy with mitomycin C. MATERIALS AND METHODS:This study retrospectively analyzed the medical records of the initial trabeculectomy with mitomycin C in patients with pri...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0b013e318285fd7d
更新日期:2014-08-01 00:00:00
abstract:PURPOSE:To assess the comparative efficacy and safety of primary deep sclerectomy (DS) augmented with subconjunctival Bevacizumab and intraoperative Mitomycin C (MMC). METHODS:Retrospective, comparative case-control series of consecutive primary DS between January 2008 and December 2010. Seventy-five eyes of 73 patien...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0b013e3182883c0c
更新日期:2015-01-01 00:00:00
abstract:PURPOSE:To evaluate the efficacy and safety of CO2 Laser-assisted Sclerectomy Surgery (CLASS) in primary and pseudoexfoliative open-angle glaucoma. MATERIALS AND METHODS:Single-arm, open-label study included data from 9 medical centers located in 7 countries. Subjects underwent nonpenetrating CLASS procedure with a CO...
journal_title:Journal of glaucoma
pub_type: 杂志文章,多中心研究,随机对照试验
doi:10.1097/IJG.0000000000000437
更新日期:2016-12-01 00:00:00
abstract:PURPOSE:During the last decades, the Baerveldt Glaucoma Implant (BGI) has proven effective in the surgical treatment of glaucoma. Various surgical procedures have been used for its implantation and these may yield different clinical outcomes and different intraoperative and postoperative complications. We evaluated the...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0b013e3182447b7c
更新日期:2013-06-01 00:00:00
abstract:AIMS:To compare the retinal nerve fiber layer thickness (RNFLT) parameters obtained with newly introduced GDx with enhanced corneal compensation (ECC) and those with GDx with variable corneal compensation (VCC) and to evaluate their reproducibility and the correspondence with visual field damage (VFD) in total or secto...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0b013e318133fb47
更新日期:2008-01-01 00:00:00
abstract:PURPOSE:To estimate resource use and costs associated with the diagnosis and treatment of glaucoma and ocular hypertension in the Netherlands in 1996 and to determine how costs differed between patients, diagnoses, and hospitals. PATIENTS AND METHODS:Patient characteristics and glaucoma-related resource use were colle...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/00061198-200106000-00007
更新日期:2001-06-01 00:00:00
abstract:PURPOSE:To report 3-year results evaluating the effect on safety and efficacy of canaloplasty to treat open-angle glaucoma when combined with cataract surgery. PATIENTS AND METHODS:This was a retrospective subset analysis of a prospective, international, multicenter study evaluating 133 eyes of 133 adult, open-angle g...
journal_title:Journal of glaucoma
pub_type: 杂志文章,多中心研究
doi:10.1097/IJG.0b013e318285ff13
更新日期:2015-03-01 00:00:00
abstract:PURPOSE:To measure the change in intraocular pressure (IOP) of the fellow eye after glaucoma surgery in 1 eye. PATIENTS AND METHODS:In this prospective interventional study, 71 patients with primary and secondary glaucoma, undergoing glaucoma surgery in 1 eye were included. The IOP in the fellow eye following glaucoma...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0000000000000217
更新日期:2016-03-01 00:00:00
abstract:PURPOSE:The Molteno implant is one of the most widely used drainage devices for the management of complicated glaucoma. Antiproliferative agents such as mitomycin-C (MMC) have markedly improved the outcome of glaucoma filtering surgery. This case control study compares the results of these two techniques in the managem...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:
更新日期:1995-04-01 00:00:00
abstract:PURPOSE:To compare the results of frequency-doubling technology perimetry (FDT), assumed to test the magnocellular visual pathway, and high-pass resolution perimetry (HRP), assumed to test the parvocellular visual pathway, in patients with ocular hypertension or glaucoma. PATIENTS AND METHODS:Forty-eight consecutive p...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/00061198-200302000-00008
更新日期:2003-02-01 00:00:00
abstract:PURPOSE:This randomized, masked, prospective study was conducted to compare the outcome of filtering surgery using doses of 0.2 mg/cc or 0.4 mg/cc of mitomycin C (MMC) in eyes that were at higher risk from previous conjunctival incisional surgery. METHODS:Eyes of 50 consecutive patients with primary open-angle, pseudo...
journal_title:Journal of glaucoma
pub_type: 临床试验,杂志文章,随机对照试验
doi:
更新日期:1999-06-01 00:00:00
abstract:PURPOSE:To report the efficacy and safety of Ahmed glaucoma valve (AGV) insertion into the ciliary sulcus in pseudophakic/aphakic patients. PATIENTS AND METHODS:A chart review was done on patients with uncontrolled glaucoma, who underwent AGV implantation with tube inserted into the ciliary sulcus. Baseline intraocula...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0b013e318265bc0b
更新日期:2014-02-01 00:00:00
abstract:PURPOSE:To determine the effect of cataract extraction on the glaucoma progression index (GPI) in glaucoma patients with coexisting cataract. PATIENTS AND METHODS:This is a retrospective noncomparative study. Consecutive eligible patients with glaucoma who underwent phacoemulsification alone or in combination with aug...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0b013e3181b21fb9
更新日期:2010-04-01 00:00:00
abstract:PURPOSE:The study investigated the applicability of the inferior≥superior≥nasal≥temporal neuroretinal rim thickness (ISNT) rule to rim thickness measured using Cirrus high-definition spectral-domain optical coherence tomography (Cirrus HD-OCT) in healthy eyes and eyes with glaucoma. METHODS:Rim thicknesses of 4 quadra...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0000000000000015
更新日期:2015-09-01 00:00:00
abstract:PURPOSE:To report the histopathologic and immunohistochemical findings from the iridectomy specimen of a patient with acquired unilateral iris heterochromia due to latanoprost. PATIENT AND METHODS:A 45-year-old woman with open-angle glaucoma and unilateral iris heterochromia was evaluated for uncontrolled intraocular ...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/00061198-200110000-00009
更新日期:2001-10-01 00:00:00
abstract:PURPOSE:Microvasculature dropout (MvD) is a novel finding seen in optical coherence tomography angiography (OCTA), which is characterized by a localized dehiscence of the choriocapillaris in the parapapillary atrophy area. Disc hemorrhage (DH) is an important factor often associated with the development and especially ...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0000000000001688
更新日期:2021-01-01 00:00:00
abstract:PURPOSE:Evaluate the long-term results of the Ahmed glaucoma valve (AGV) surgery in association with bevacizumab (Avastin) in neovascular glaucoma (NVG) patients. DESIGN AND METHODS:This retrospective institutional study reviewed 39 eyes of 34 patients with NVG who underwent AGV implantation. The intravitreal bevacizu...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0000000000000234
更新日期:2015-06-01 00:00:00
abstract:PURPOSE:To determine the clinical features and anatomic parameters in asymptomatic (creeping) and symptomatic, chronic, primary angle-closure glaucoma (PACG) as compared with open-angle glaucoma (OAG) and with control subjects with normal eyes. METHODS:Forty consecutive patients with each of the following four types o...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/00061198-200006000-00002
更新日期:2000-06-01 00:00:00
abstract:PURPOSE:To assess the relationship between pupillary light reflex and estimated retinal ganglion cell (RGC) counts in patients with glaucoma. METHODS:We recorded and analyzed pupil responses using an automated binocular pupillometer in 148 patients with glaucoma (mean age 67±11, 49% female) and 71 controls (age 60±9.6...
journal_title:Journal of glaucoma
pub_type: 杂志文章
doi:10.1097/IJG.0000000000001183
更新日期:2019-03-01 00:00:00