A Population-based Investigation of Circadian Rhythm of Intraocular Pressure in Habitual Position Among Healthy Subjects: The Handan Eye Study.

Abstract:

PURPOSE:(1) To investigate the reference value of peak-trough difference in circadian rhythm of intraocular pressure (IOP) in habitual position and (2) to compare the IOP parameters among 3 age groups. MATERIALS AND METHODS:Habitual IOP of healthy subjects sampled from the population in the Handan Eye Study was measured every 2 hours in the seated position during light-wake period (7:30 AM, 9:30 AM, 11:30 AM, 1:30 PM, 3:30 PM, 5:30 PM, 7:30 PM, 9:30 PM) and in the supine position during dark-sleep period (11:30 PM, 1:30 AM, 3:30 AM, 5:30 AM). Blood pressure and heart rate were obtained subsequently at each IOP measurement. RESULTS:Two hundred six healthy subjects were included in the final analyses (n=20, 30 to 39 y old; n=95, 40 to 49 y old; n=91, 50 to 59 y old). For peak-trough difference (7.2±2.3 mm Hg; 6.8 to 7.5 mm Hg, 95% confidence interval) in habitual position, the reference value was described as median 7.0 mm Hg, 25th percentile 5.5 mm Hg, and 95th percentile 11.5 mm Hg. No significant differences in peak-trough difference, acrophase (cosine-fit analysis derived peak timing) and amplitude (half distance between the cosine-fit maximum and minimum) were found among the 3 age groups. In the cosine model, the nocturnal acrophase (3:49±0.53 AM; 3:42 to 3:55 AM, 95% confidence interval) was detected for the entire group. Furthermore, 106 subjects (52%) had a nocturnal peak pattern, 36 subjects (17%) had a diurnal peak pattern, and 64 subjects (31%) had no evident pattern. CONCLUSIONS:In habitual position, 75% of healthy subjects from a population-based investigation had IOP variation >5.5 mm Hg and 95% subjects had <11.5 mm Hg variation. Aging may not influence the circadian habitual IOP rhythm.

journal_name

J Glaucoma

journal_title

Journal of glaucoma

authors

Wang NL,Hao J,Zhen Y,Liu JH,Li SZ,Wang H,Chen H,Peng XX,Han W,Fan SJ,Weinreb RN

doi

10.1097/IJG.0000000000000351

subject

Has Abstract

pub_date

2016-07-01 00:00:00

pages

584-9

issue

7

eissn

1057-0829

issn

1536-481X

journal_volume

25

pub_type

杂志文章
  • Long-term results of Ahmed glaucoma valve in association with intravitreal bevacizumab in neovascular glaucoma.

    abstract:PURPOSE:Evaluate the long-term results of the Ahmed glaucoma valve (AGV) surgery in association with bevacizumab (Avastin) in neovascular glaucoma (NVG) patients. DESIGN AND METHODS:This retrospective institutional study reviewed 39 eyes of 34 patients with NVG who underwent AGV implantation. The intravitreal bevacizu...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000000234

    authors: Sahyoun M,Azar G,Khoueir Z,Antoun J,Kourie H,Nehme J,Jalkh A

    更新日期:2015-06-01 00:00:00

  • Three-Year Follow-up of a Novel Aqueous Humor MicroShunt.

    abstract:AIMS:An observational study to determine the safety and efficacy of filtering surgery employing a microlumen aqueous drainage device (InnFocus MicroShunt), used intraoperatively with Mitomycin C, implanted alone or in combination with phacoemulsification. MATERIALS AND METHODS:Single-site, prospective, nonrandomized s...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000000368

    authors: Batlle JF,Fantes F,Riss I,Pinchuk L,Alburquerque R,Kato YP,Arrieta E,Peralta AC,Palmberg P,Parrish RK 2nd,Weber BA,Parel JM

    更新日期:2016-02-01 00:00:00

  • Retinal nerve fiber layer analysis of cupping in children born prematurely.

    abstract:PURPOSE:The aim of this study was to quantitatively study the retinal nerve fiber layer (RNFL) thickness in children born prematurely with isolated optic nerve cupping. PATIENTS AND METHODS:Six otherwise healthy premature children with clinical evidence of increased cup to disc ratios were enrolled in this observation...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000000006

    authors: Glass LR,Cioffi GA,Blumberg DM

    更新日期:2014-01-01 00:00:00

  • Assessing the Methodological Quality of Glaucoma Clinical Practice Guidelines and Their Recommendations on Microinvasive Glaucoma Surgery: A Systematic Review.

    abstract:INTRODUCTION:Clinical practice guidelines (CPG) are regarded by many as critical communications providing guidance within specific medical fields. Over a decade ago, the first microinvasive glaucoma surgical (MIGS) procedures were introduced. Since then, a number of these novel intraocular pressure controlling surgical...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000000820

    authors: Michaelov E,Armstrong JJ,Nguyen M,Instrum B,Lam T,Denstedt J,Hutnik CML

    更新日期:2018-02-01 00:00:00

  • High failure rate associated with 180 degrees selective laser trabeculoplasty.

    abstract:PURPOSE:To determine the efficacy of selective laser trabeculoplasty (SLT) in a tertiary care referral center. PATIENTS AND METHODS:In this retrospective study of selective laser trabeculoplasty performed by five physicians, 94 eyes from 94 patients were included. A majority (83/92, 90%) underwent 180 degrees selectiv...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/01.ijg.0000176939.43681.c2

    authors: Song J,Lee PP,Epstein DL,Stinnett SS,Herndon LW Jr,Asrani SG,Allingham RR,Challa P

    更新日期:2005-10-01 00:00:00

  • Reversal of disc cupping after intraocular pressure reduction in topographic image series.

    abstract:PURPOSE:To identify and characterize 'reversal' of optic nerve cupping following intraocular pressure (IOP) lowering in scanning laser tomography (SLT) longitudinal image series. METHODS:Modification was made to a previously described analytical approach to longitudinally study putatively increased rim area following ...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/01.ijg.0000133151.82804.e3

    authors: Tan JC,Hitchings RA

    更新日期:2004-10-01 00:00:00

  • A Novel Method of Extending Glaucoma Drainage Tube: "Tube-in-Tube" Technique.

    abstract:PURPOSE:To describe a new and simple technique of glaucoma tube extension that carries several advantages over previously described techniques. PATIENTS AND METHODS:A retrospective noncomparative case series of 3 patients (1 adult and 2 pediatric cases) with glaucoma tube retraction managed by the "tube-in-tube" techn...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000000567

    authors: Chiang MY,Camuglia JE,Khaw PT

    更新日期:2017-02-01 00:00:00

  • A randomized clinical trial of selective laser trabeculoplasty versus argon laser trabeculoplasty in patients with pseudoexfoliation.

    abstract:PURPOSE:To evaluate the efficacy of selective laser trabeculoplasty (SLT) versus argon laser trabeculoplasty (ALT) in lowering the intraocular pressure (IOP) in patients with open-angle glaucoma or ocular hypertension secondary to pseudoexfoliation. DESIGN:Multicentered randomized clinical trial. PARTICIPANTS:A total...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章,多中心研究,随机对照试验

    doi:10.1097/IJG.0b013e31829e55e4

    authors: Kent SS,Hutnik CM,Birt CM,Damji KF,Harasymowycz P,Si F,Hodge W,Pan I,Crichton A

    更新日期:2015-06-01 00:00:00

  • Efficacy and safety of inferior 180 degrees goniosynechialysis followed by diode laser peripheral iridoplasty in the treatment of chronic angle-closure glaucoma.

    abstract:PURPOSE:To report the efficacy and safety of inferior 180 degrees goniosynechialysis followed by diode laser peripheral iridoplasty in the treatment of chronic angle-closure glaucoma with total synechial angle closure. METHODS:Five patients with chronic angle-closure glaucoma and total synechial angle closure whose in...

    journal_title:Journal of glaucoma

    pub_type: 临床试验,杂志文章

    doi:10.1097/00061198-200010000-00007

    authors: Lai JS,Tham CC,Chua JK,Lam DS

    更新日期:2000-10-01 00:00:00

  • Risk factors for hyphema after trabeculectomy with mitomycin C.

    abstract:PURPOSE:To determine the risk factors for hyphema after trabeculectomy with mitomycin C (MMC). PATIENTS AND METHODS:In total, 420 patients (420 eyes) with glaucoma who underwent trabeculectomy with MMC between June 1, 2005 and December 31, 2010 at Kumamoto University Hospital, Japan, were retrospectively evaluated. Hy...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0b013e3182741c85

    authors: Kojima S,Inatani M,Shobayashi K,Haga A,Inoue T,Tanihara H

    更新日期:2014-06-01 00:00:00

  • The Association Between Macula and ONH Optical Coherence Tomography Angiography (OCT-A) Vessel Densities in Glaucoma, Glaucoma Suspect, and Healthy Eyes.

    abstract:PURPOSE:To evaluate strength of associations between optical coherence tomography (OCT)-angiography vessel density (VD) measurements in the macula and peripapillary region of the optic nerve head (ONH) with standard structural OCT thickness measures. MATERIALS AND METHODS:This cross-sectional study included 333 eyes o...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000000862

    authors: Manalastas PIC,Zangwill LM,Daga FB,Christopher MA,Saunders LJ,Shoji T,Akagi T,Penteado RC,Yarmohammadi A,Suh MH,Medeiros FA,Weinreb RN

    更新日期:2018-03-01 00:00:00

  • Progressive High Hypermetropic Shift as a Refractive Surprise Following Glaucoma Filtration Surgery in a Phakic Child With Early-Onset Childhood Glaucoma Associated With Axenfeld-Rieger Anomaly.

    abstract:PURPOSE:We report a case of progressive high hypermetropia following glaucoma filtration surgery in a child with Axenfeld-Rieger syndrome and congenital glaucoma. METHODS/RESULTS:We report a case of a 4-day-old female child presented as a case of Axenfeld-Rieger anomaly with secondary glaucoma in both eyes (OU), who u...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000001283

    authors: Kumar P,Senthil S

    更新日期:2019-08-01 00:00:00

  • Resource use and costs of patients with glaucoma or ocular hypertension: a one-year study based on retrospective chart review in the Netherlands.

    abstract:PURPOSE:To estimate resource use and costs associated with the diagnosis and treatment of glaucoma and ocular hypertension in the Netherlands in 1996 and to determine how costs differed between patients, diagnoses, and hospitals. PATIENTS AND METHODS:Patient characteristics and glaucoma-related resource use were colle...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/00061198-200106000-00007

    authors: Oostenbrink JB,Rutten-van Mölken MP,Sluyter-Opdenoordt TS

    更新日期:2001-06-01 00:00:00

  • Influence of total energy delivery on success rate after contact diode laser transscleral cyclophotocoagulation: a retrospective case review and meta-analysis.

    abstract:PURPOSE:To evaluate the effect of a single treatment of contact diode laser transscleral cyclophotocoagulation (TSCP) on intraocular pressure (IOP) in patients with refractory glaucoma and perform a historical meta-analysis of the relationship between successful IOP control and various laser parameters. METHODS:Clinic...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章,meta分析

    doi:10.1097/00061198-200208000-00009

    authors: Hauber FA,Scherer WJ

    更新日期:2002-08-01 00:00:00

  • Extrusion and Breakage of XEN Gel Stent Resulting in Endophthalmitis.

    abstract::The mainstay of open-angle glaucoma surgery involves subconjunctival drainage of aqueous fluid. Insertion of the XEN Gel Stent leads to formation of a subconjunctival bleb to assist in the drainage of aqueous fluid and offers the advantage of ease and speed of insertion with conjunctival sparing over traditional surgi...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000001058

    authors: Lapira M,Cronbach N,Shaikh A

    更新日期:2018-10-01 00:00:00

  • Expression and regulation of LOXL1 and elastin-related genes in eyes with exfoliation syndrome.

    abstract::Variants in LOXL1 are significantly associated with exfoliation syndrome (XFS), however the impact of the associated variants on disease development is not yet understood. Initially the associated missense changes, R141L and G153D, were considered to be pathogenic alleles. Flipping of the risk allele in certain popula...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章,评审

    doi:10.1097/IJG.0000000000000124

    authors: Wiggs JL,Pasquale LR

    更新日期:2014-10-01 00:00:00

  • Ahmed glaucoma valve implantation with tube insertion through the ciliary sulcus in pseudophakic/aphakic eyes.

    abstract:PURPOSE:To report the efficacy and safety of Ahmed glaucoma valve (AGV) insertion into the ciliary sulcus in pseudophakic/aphakic patients. PATIENTS AND METHODS:A chart review was done on patients with uncontrolled glaucoma, who underwent AGV implantation with tube inserted into the ciliary sulcus. Baseline intraocula...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0b013e318265bc0b

    authors: Eslami Y,Mohammadi M,Fakhraie G,Zarei R,Moghimi S

    更新日期:2014-02-01 00:00:00

  • Ciliary body melanocytoma with anterior segment pigment dispersion and elevated intraocular pressure.

    abstract:PURPOSE:To discuss a case in which melanocytoma of the ciliary body presented with widespread pigment dispersion and elevated intraocular pressure (IOP). METHODS:A 64-year old woman presented with increased IOP and persistent anterior segment inflammation in her right eye. She had undergone a trabeculectomy for uncont...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:

    authors: Bhorade AM,Edward DP,Goldstein DA

    更新日期:1999-04-01 00:00:00

  • The prevalence of glaucomatous defects with short-wavelength automated perimetry in patients with elevated intraocular pressures.

    abstract:PURPOSE:To determine the prevalence of abnormal short-wavelength automated perimetry (SWAP) visual fields in subjects with elevated intraocular pressures (IOP) for 7 existing definitions of mild glaucomatous loss, and to explore the agreement between them. PATIENTS AND METHODS:Seven hundred and forty-four eyes of 379 ...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/01.ijg.0000146363.90506.b2

    authors: Reus NJ,Colen TP,Lemij HG

    更新日期:2005-02-01 00:00:00

  • Preliminary Report on a Novel Virtual Reality Perimeter Compared With Standard Automated Perimetry.

    abstract:PRECIS:The VisuALL head-mounted perimetry in normal subjects and glaucoma patients had a moderate to strong correlation with the Humphrey Field Analyzer (HFA). PURPOSE:Visual field testing has a vital role in diagnosing and managing glaucoma. The current clinical practice relies on large, table-based testing units. Th...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000001670

    authors: Razeghinejad R,Gonzalez-Garcia A,Myers JS,Katz LJ

    更新日期:2021-01-01 00:00:00

  • Sterile single use cover for the G-probe Transscleral Cyclodiode.

    abstract:PURPOSE:Multiuse of the G-probe transscleral cyclophotocoagulation (TSCPC) device can lead to contamination. We evaluated the mechanical stability and clinical efficacy of a disposable sterile barrier for the G-probe footplate. METHODS:We measured diode laser output with and without the G-probe barrier both before and...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0b013e3181e08109

    authors: Rootman DB,Howarth D,Kerr JQ,Flanagan JG,Trope GE,Buys YM

    更新日期:2011-04-01 00:00:00

  • Near and Distance Stereoacuity in Patients With Primary Open-angle Glaucoma.

    abstract:PURPOSE:To compare near and distance stereoacuity between patients with primary open-angle glaucoma (POAG) and a control group, and to analyze the associations between stereoacuity and POAG severity. METHODS:This cross-sectional study compared near and distance stereoacuity between the POAG and control groups. The dat...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000000963

    authors: Park CK,Kim DW,Lee CK

    更新日期:2018-06-01 00:00:00

  • Comparison of Thickness-Function and Vessel Density-Function Relationship in the Superior and Inferior Macula, and in the Superotemporal and Inferotemporal Peripapillary Sectors.

    abstract::PRéCIS:: In primary open-angle glaucoma (POAG), unlogged mean macular hemifield visual field sensitivity correlates significantly better with superficial capillary vessel density (VD) than with ganglion cell complex (GCC) thickness of the opposite macular hemifield. PURPOSE:The aim of this study was to compare the re...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000001441

    authors: Holló G

    更新日期:2020-03-01 00:00:00

  • Semiconductor diode laser transscleral cyclophotocoagulation in a patient with glaucoma secondary to metastatic tumor to the iris.

    abstract:PURPOSE:Management of a case of glaucoma secondary to an iris metastasis is reported. RESULTS:A 31-year-old woman developed glaucoma secondary to a metastatic tumor to the iris. Anti-glaucoma medication failed to control the increase in intraocular pressure (IOP). However, diode laser cyclophotocoagulation controlled ...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:

    authors: El-Harazi SM,Kellaway J,Feldman RM

    更新日期:1998-10-01 00:00:00

  • Radial Peripapillary Capillary Density Measurement Using Optical Coherence Tomography Angiography in Early Glaucoma.

    abstract:PURPOSE:The purpose of the study was to compare radial peripapillary capillary (RPC) density between normal subjects and patients with early primary open-angle glaucoma (POAG) using optical coherence tomography angiography (OCT-A). MATERIALS AND METHODS:A total of 24 patients with early POAG and age-matched 52 normal ...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000000649

    authors: Mansoori T,Sivaswamy J,Gamalapati JS,Balakrishna N

    更新日期:2017-05-01 00:00:00

  • Structure-function relationships using the Cirrus spectral domain optical coherence tomograph and standard automated perimetry.

    abstract:PURPOSE:To evaluate the relationship between glaucomatous structural damage assessed by the Cirrus Spectral Domain OCT (SDOCT) and functional loss as measured by standard automated perimetry (SAP). METHODS:Four hundred twenty-two eyes (78 healthy, 210 suspects, 134 glaucomatous) of 250 patients were recruited from the...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0b013e31822af27a

    authors: Leite MT,Zangwill LM,Weinreb RN,Rao HL,Alencar LM,Medeiros FA

    更新日期:2012-01-01 00:00:00

  • Deep Sclerectomy With a New Nonabsorbable Uveoscleral Implant (Esnoper-Clip): 1-Year Outcomes.

    abstract:PURPOSE:To report the safety and the effectiveness of deep sclerectomy (DS) with a new nonabsorbable uveoscleral hema implant (Esnoper-Clip) designed to increase trabecular and uveoscleral outflow and to achieve higher intrascleral blebs. MATERIALS AND METHODS:Twenty-seven eyes of 27 patients with open-angle glaucoma,...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000000253

    authors: Loscos-Arenas J,Parera-Arranz A,Romera-Romera P,Castellvi-Manent J,Sabala-Llopart A,de la Cámara-Hermoso J

    更新日期:2015-08-01 00:00:00

  • Effect of cataract extraction on the glaucoma progression index (GPI) in glaucoma patients.

    abstract:PURPOSE:To determine the effect of cataract extraction on the glaucoma progression index (GPI) in glaucoma patients with coexisting cataract. PATIENTS AND METHODS:This is a retrospective noncomparative study. Consecutive eligible patients with glaucoma who underwent phacoemulsification alone or in combination with aug...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0b013e3181b21fb9

    authors: Ang GS,Shunmugam M,Azuara-Blanco A

    更新日期:2010-04-01 00:00:00

  • Characteristics of Patients Receiving Treatment Who Deny A Diagnosis Glaucoma or Elevated Intraocular Pressure in the United States.

    abstract:PURPOSE:The purpose of this study was to determine the proportion of patients in the US population who are receiving long-term intraocular pressure (IOP)-lowering medication, but, deny having a diagnosis of glaucoma or elevated IOP. MATERIALS AND METHODS:The National Health and Nutrition Examination Survey (NHANES) is...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000001035

    authors: Lowry EA,Mansberger SL

    更新日期:2018-11-01 00:00:00

  • Macular and retinal nerve fiber layer thickness measurement reproducibility using optical coherence tomography (OCT-3).

    abstract:PURPOSE:To assess the reproducibility of retinal nerve fiber layer thickness and macular thickness measurements using OCT-3. METHODS:Randomly chosen eyes of healthy individuals were scanned following pupillary dilation by two trained operators (RGO, RV) using OCT-3 (software version A1.1, Carl Zeiss Meditec, Inc., Dub...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/00061198-200406000-00012

    authors: Gürses-Ozden R,Teng C,Vessani R,Zafar S,Liebmann JM,Ritch R

    更新日期:2004-06-01 00:00:00