Sterile single use cover for the G-probe Transscleral Cyclodiode.

Abstract:

PURPOSE:Multiuse of the G-probe transscleral cyclophotocoagulation (TSCPC) device can lead to contamination. We evaluated the mechanical stability and clinical efficacy of a disposable sterile barrier for the G-probe footplate. METHODS:We measured diode laser output with and without the G-probe barrier both before and after cadaver TSCPC (18 shots at 2000 mW for 2000mS). Qualitative analyses of the laser aiming beam were made before each trial in the barrier and nonbarrier state. After each trial, the G-probe barrier was examined for microperforations and footplate for debris and/or damage. Microbiology was taken on the cadaver eye and the G-probe before and after 20 cycles. Histologic analysis after TSCPC with and without barrier was carried out on a cadaver eye. RESULTS:Qualitatively, laser focus dispersion was minimized by the G-probe cover. Mean (95% CI) laser output was measured for the nonbarrier, with barrier pre-TSCPC and with barrier post-TSCPC, respectively as 980 mW (899,1061), 1247 mW (1115, 1378), and 1240 mW (1132, 1347). The difference between the nonbarrier and barrier both preTSCPC and postTSCPC was statistically significant (df=2, F=36.26, P<0.01). No perforations in the G-probe barrier were evident and no debris or damage was detected on the G-probe. Pathology was consistent with earlier reports of TSCPC in cadaver eyes. Microbial segregation of the cadaver eye and the G-probe footplate was maintained. CONCLUSIONS:The G-probe barrier is an effective and robust method to protect consecutive patients from contamination during TSCPC. Although energy levels were slightly higher in probes with barrier, histologic differences were not evident and the clinical significance of this finding is likely limited.

journal_name

J Glaucoma

journal_title

Journal of glaucoma

authors

Rootman DB,Howarth D,Kerr JQ,Flanagan JG,Trope GE,Buys YM

doi

10.1097/IJG.0b013e3181e08109

subject

Has Abstract

pub_date

2011-04-01 00:00:00

pages

260-5

issue

4

eissn

1057-0829

issn

1536-481X

journal_volume

20

pub_type

杂志文章
  • Relationship Between Serum Glucose Levels and Intraocular Pressure, a Population-based Cross-sectional Study.

    abstract:PURPOSE:The purpose of this study is to assess the relationship between serum glucose levels and intraocular pressure (IOP) both in subjects with impaired fasting glucose (IFG) as well as in subjects with diabetes mellitus (DM). MATERIALS AND METHODS:Data of a cross-sectional sample of 18,406 subjects who underwent ro...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000000700

    authors: Cohen E,Kramer M,Shochat T,Goldberg E,Krause I

    更新日期:2017-07-01 00:00:00

  • Transconjunctival mitomycin C as an adjunct to conventional glaucoma filtration surgery in rabbits.

    abstract:PURPOSE:Subconjunctival mitomycin C has been used in glaucoma filtration surgery with success. A prospective, randomized, masked, placebo-controlled study was performed to evaluate whether single transconjunctival mitomycin C applied either preoperatively or postoperatively would enhance the success of filtration surge...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:

    authors: Buffenn AN,Saetre SB,Higginbotham EJ,Musch DC,Kincaid MC

    更新日期:1997-10-01 00:00:00

  • Outcomes of Nd: YAG Goniopuncture After Viscocanalostomy/Phacoviscocanalostomy.

    abstract:PURPOSE:The aim of this study is to evaluate the safety and efficacy of laser goniopuncture (LGP) to lower intraocular pressure (IOP) post-viscocanalostomy (VC)/phacoviscocanalostomy (PVC). Outcomes include: IOP reduction from pre-LGP levels and the need for further topical antiglaucomatous medication or surgery. PATI...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000000333

    authors: Mathews D,Shirodkar AL,Ahnood D,Garrick A

    更新日期:2016-06-01 00:00:00

  • Glycerin-preserved Human-donor Corneoscleral Patch Grafts for Glaucoma Drainage Devices.

    abstract:PRECIS:Glycerin-preserved, human-donor, corneoscleral patch grafts are effective and safe for glaucoma drainage device (GDD) implantation, and they are comparable to previously reported materials. It can be preserved with the sterile technique for up to 12 months. PURPOSE:To evaluate the efficacy and safety of glyceri...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000001610

    authors: Kitnarong N,Srikulsasitorn B,Aurboonsong T

    更新日期:2020-11-01 00:00:00

  • Evaluation and comparison of indentation ultrasound biomicroscopy gonioscopy in relative pupillary block, peripheral anterior synechia, and plateau iris configuration.

    abstract:PURPOSE:To evaluate and compare the findings and changes of the anterior chamber angle configuration with indentation ultrasound biomicroscopy (UBM) gonioscopy in relative pupillary block (RPB), peripheral anterior synechia (PAS), and plateau iris configuration (PIC). METHODS:This study included 73 eyes of 52 patients...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/01.ijg.0000141366.45974.3a

    authors: Matsunaga K,Ito K,Esaki K,Sugimoto K,Sano T,Miura K,Sasoh M,Uji Y

    更新日期:2004-12-01 00:00:00

  • Structure-function relationships using the Cirrus spectral domain optical coherence tomograph and standard automated perimetry.

    abstract:PURPOSE:To evaluate the relationship between glaucomatous structural damage assessed by the Cirrus Spectral Domain OCT (SDOCT) and functional loss as measured by standard automated perimetry (SAP). METHODS:Four hundred twenty-two eyes (78 healthy, 210 suspects, 134 glaucomatous) of 250 patients were recruited from the...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0b013e31822af27a

    authors: Leite MT,Zangwill LM,Weinreb RN,Rao HL,Alencar LM,Medeiros FA

    更新日期:2012-01-01 00:00:00

  • Long-term results of Ahmed glaucoma valve in association with intravitreal bevacizumab in neovascular glaucoma.

    abstract:PURPOSE:Evaluate the long-term results of the Ahmed glaucoma valve (AGV) surgery in association with bevacizumab (Avastin) in neovascular glaucoma (NVG) patients. DESIGN AND METHODS:This retrospective institutional study reviewed 39 eyes of 34 patients with NVG who underwent AGV implantation. The intravitreal bevacizu...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000000234

    authors: Sahyoun M,Azar G,Khoueir Z,Antoun J,Kourie H,Nehme J,Jalkh A

    更新日期:2015-06-01 00:00:00

  • Episcleral Venous Outflow: A Potential Outcome Marker for iStent Surgery.

    abstract:PURPOSE:(1) To propose the use of episcleral venous outflow (EVO) as an outcome marker of iStent surgery, and an EVO grading scale. (2) To determine the association of EVO with: (a) postoperative intraocular pressure (IOP) and medication burden; (b) iStent patency status. PATIENTS AND METHODS:Retrospective cohort stud...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000000799

    authors: Bostan C,Harasymowycz P

    更新日期:2017-12-01 00:00:00

  • Managing Delayed Suprachoroidal Hemorrhage After Insertion of XEN45 Glaucoma Device.

    abstract::A 78-year-old man with angle closure glaucoma and on treatment with oral anticoagulants, underwent phacoemulsification. An early acute suprachoroidal hemorrhage (SCH) occurred and the surgical wound was rapidly sutured without complete soft lens matter removal, nor insertion of intraocular lens. The SCH was managed co...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000001170

    authors: Stringa F,Ali Z,Christou S,Karandikar S,Shankar V

    更新日期:2019-05-01 00:00:00

  • Correlation of automated visual field parameters and peripapillary nerve fiber layer thickness as measured by scanning laser polarimetry.

    abstract:PURPOSE:To correlate Humphrey visual field mean sensitivity and peripapillary nerve fiber layer thickness as measured by scanning laser polarimetry. METHODS:The authors studied 54 eyes of 34 patients who visited a university-based glaucoma clinic and had undergone scanning laser polarimetry and Humphrey perimetry with...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/00061198-200008000-00001

    authors: Kwon YH,Hong S,Honkanen RA,Alward WL

    更新日期:2000-08-01 00:00:00

  • Randomized Prospective Study of the Use of Anti-Inflammatory Drops After Selective Laser Trabeculoplasty.

    abstract:PURPOSE:Evaluating the use of Indomethacin, Dexamethasone, and no anti-inflammatory treatment immediately after selective laser trabeculoplasty (SLT). MATERIALS AND METHODS:Prospective randomized clinical trial of 132 eyes. Both eyes of the patient underwent SLT. One of the eyes was treated with Indomethacin 0.1% or D...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章,随机对照试验

    doi:10.1097/IJG.0000000000000522

    authors: De Keyser M,De Belder M,De Groot V

    更新日期:2017-02-01 00:00:00

  • Comparing spectral-domain optical coherence tomography and standard automated perimetry to diagnose glaucomatous optic neuropathy.

    abstract:PURPOSE:To compare the abilities of standard automated perimetry (SAP) and spectral-domain optical coherence tomography (SDOCT) in diagnosing eyes with glaucomatous optic neuropathy (GON). METHODS:In a cross-sectional study, 280 eyes of 175 subjects referred to tertiary eye care center by general ophthalmologists for ...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000000048

    authors: Rao HL,Yadav RK,Addepalli UK,Begum VU,Senthil S,Choudhari NS,Garudadri CS

    更新日期:2015-06-01 00:00:00

  • Effect of 2 Novel Sustained-release Drug Release Systems on Bleb Fibrosis: An In Vivo Trabeculectomy Study in a Rabbit Model.

    abstract:PRECIS:Rabbit model studies suggested better morphology blebs with equal intraocular pressure (IOP) efficacy as a standard mitomycin C (MMC) trabeculectomy using a novel slow-release drug delivery antifibrotic system delivering small quantities of MMC and 5-fluorouracil (5-FU). PURPOSE:To evaluate 2 different concentr...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000001215

    authors: Swann FB,Singh S,Blake D,John V,Le C,Fullerton M,Margo C,Zhang Z,Muddasani N,Wall J,Satija C,Greenberg E,Mancera N,Zurakowski D,Ayyala RS

    更新日期:2019-06-01 00:00:00

  • Outcomes of Trabeculectomy With Mitomycin-C in Uveitis Associated With Vogt-Koyanagi-Harada Disease.

    abstract:OBJECTIVES:To evaluate the outcomes of trabeculectomy with mitomycin-C (MMC) in uveitis associated with Vogt-Koyanagi-Harada disease (VKH). METHODS:Retrospective cohort study included 27 eyes of 15 patients with uveitic glaucoma associated with VKH disease who underwent trabeculectomy with MMC as a first glaucoma proc...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000000384

    authors: Almobarak FA,Alharbi AH,Morales J,Aljadaan I

    更新日期:2016-06-01 00:00:00

  • Ahmed Valve Upstream Obstruction Caused by Fibrous Ingrowth: Surgical Approach.

    abstract::Glaucoma secondary to penetrating keratoplasty can be challenging and multiple surgeries may be needed to control the intraocular pressure (IOP), including the use of glaucoma drainage implants. However, late failure of these drainage implant surgery is common, mostly because of excessive scarring or bleb encapsulatio...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000000739

    authors: Medeiros Pinto J,Pinto Ferreira N,Abegão Pinto L

    更新日期:2017-10-01 00:00:00

  • Glycomics, extracellular matrix, and anti-glycan antibodies in exfoliation syndrome.

    abstract::Exfoliation syndrome (XFS) is considered to be a disease of extracellular matrix. Here we review key experimental evidence of aberrations in structure, expression, and function of glycoproteins, complex carbohydrates, and glycosaminoglycans found in extracellular matrix components forming exfoliation material in patie...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章,评审

    doi:10.1097/IJG.0000000000000118

    authors: Huflejt ME,Preiss JS,Thomson JE,Gils IM,Vuskovic MI

    更新日期:2014-10-01 00:00:00

  • Isopropyl unoprostone increases the activities of matrix metalloproteinases in cultured monkey ciliary muscle cells.

    abstract:PURPOSE:The mechanism by which the prostaglandin F2alpha-related antiglaucoma compound isopropyl unoprostone (referred to as unoprostone) reduces intraocular pressure is largely unknown. Another prostaglandin F2alpha-related compound, latanoprost, influences the activities of matrix metalloproteinases in ciliary muscle...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/00061198-200108000-00005

    authors: Kashiwagi K,Jin M,Suzuki M,Tanaka Y,Iizuka Y,Tsukahara S

    更新日期:2001-08-01 00:00:00

  • Continuous monitoring of intraocular pressure: rationale and progress toward a clinical device.

    abstract::Intraocular pressure (IOP) is a dynamic physiologic parameter with regular circadian variations and unpredictable short-term and long-term fluctuations. Current methods of measuring IOP are suboptimal with a typical clinical practice only performing periodic IOP measurements during regular office hours. Diurnal and 24...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章,评审

    doi:10.1097/IJG.0b013e3181862490

    authors: Sit AJ

    更新日期:2009-04-01 00:00:00

  • Which patients are treated for glaucoma? An observational analysis.

    abstract:PURPOSE:More than one million patients in the United States are treated for glaucoma, although little is known about the typical clinical characteristics of this group of patients and the type of therapy they receive. This study was conducted to describe the demographic and diagnostic characteristics of patients beginn...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/00061198-200002000-00008

    authors: Bohn RL,Gurwitz JH,Yeomans SM,Glynn RJ,Pasquale LR,Walker AM,Avorn J

    更新日期:2000-02-01 00:00:00

  • Evaluation of the whole-field scotopic retinal sensitivity tester in clinical glaucoma practice.

    abstract::We determined the results of routine whole-field scotopic vision testing in consecutive patients with ocular hypertension or glaucoma who underwent Humphrey automated perimetric testing and optic disc examination. In 39 ocular hypertensive patients we found a mean threshold of 16.7 +/- 7.4 dB and in 61 glaucoma patien...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:

    authors: Stewart WC,Chorak RP,Murrell HP

    更新日期:1994-01-01 00:00:00

  • Longitudinal Changes in Bleb Height, Vascularity, and Conjunctival Microcysts After Trabeculectomy.

    abstract:OBJECTIVE:The objective of this article was to study longitudinal changes in bleb morphology (presence of microcysts and bleb height and vascularity) in subjects enrolled in the Singapore 5-Fluorouracil (5-FU) trabeculectomy study. STUDY DESIGN:Retrospective subgroup analysis of a randomized controlled trial. MATERIA...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章,随机对照试验

    doi:10.1097/IJG.0000000000000967

    authors: Kumaran A,Husain R,Htoon HM,Aung T

    更新日期:2018-07-01 00:00:00

  • Acute angle-closure glaucoma in a patient with miller fisher syndrome without pupillary dysfunction.

    abstract:PURPOSE:To report a case of an angle-closure glaucoma in a patient with Miller Fisher syndrome (MFS) without pupillary dysfunction. METHODS:We present a case report of a 75-year-old male presenting with total ophthalmoplegia, complete bilateral ptosis, and gait disturbance. He was diagnosed with MFS without pupillary ...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000000191

    authors: Ryu WY,Kim JK,Jin SW,Shim DH

    更新日期:2015-02-01 00:00:00

  • Mitomycin C in higher risk trabeculectomy: a prospective comparison of 0.2- to 0.4-mg/cc doses.

    abstract:PURPOSE:This randomized, masked, prospective study was conducted to compare the outcome of filtering surgery using doses of 0.2 mg/cc or 0.4 mg/cc of mitomycin C (MMC) in eyes that were at higher risk from previous conjunctival incisional surgery. METHODS:Eyes of 50 consecutive patients with primary open-angle, pseudo...

    journal_title:Journal of glaucoma

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:

    authors: Sanders SP,Cantor LB,Dobler AA,Hoop JS

    更新日期:1999-06-01 00:00:00

  • Meibomian Gland Features and Conjunctival Goblet Cell Density in Glaucomatous Patients Controlled With Prostaglandin/Timolol Fixed Combinations: A Case Control, Cross-sectional Study.

    abstract:PURPOSE:To investigate, using in vivo confocal microscopy (IVCM), the Meibomian gland (MG) features and conjunctival goblet cell density (GCD) in glaucomatous patients controlled with prostaglandin/timolol fixed combinations (PTFCs). MATERIALS AND METHODS:In this cross-sectional study, 60 white patients were treated w...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000000899

    authors: Agnifili L,Mastropasqua R,Fasanella V,Brescia L,Scatena B,Oddone F,Mastropasqua L

    更新日期:2018-04-01 00:00:00

  • Macular and retinal nerve fiber layer thickness measurement reproducibility using optical coherence tomography (OCT-3).

    abstract:PURPOSE:To assess the reproducibility of retinal nerve fiber layer thickness and macular thickness measurements using OCT-3. METHODS:Randomly chosen eyes of healthy individuals were scanned following pupillary dilation by two trained operators (RGO, RV) using OCT-3 (software version A1.1, Carl Zeiss Meditec, Inc., Dub...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/00061198-200406000-00012

    authors: Gürses-Ozden R,Teng C,Vessani R,Zafar S,Liebmann JM,Ritch R

    更新日期:2004-06-01 00:00:00

  • Ex-PRESS miniature glaucoma device implanted under a scleral flap alone or combined with phacoemulsification cataract surgery.

    abstract:PURPOSE:Our purpose was to evaluate the clinical outcomes of the Ex-PRESS miniature glaucoma device placed under a partial-thickness scleral flap as a single procedure or combined with phacoemulsification cataract surgery. METHODS:This was a comparative consecutive case series of 345 eyes: 231 eyes treated with Ex-PRE...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0b013e31818fb44e

    authors: Kanner EM,Netland PA,Sarkisian SR Jr,Du H

    更新日期:2009-08-01 00:00:00

  • Latanoprost or brimonidine as treatment for elevated intraocular pressure: multicenter trial in the United States.

    abstract:PURPOSE:To compare the efficacy and tolerability of latanoprost or brimonidine in patients with elevated intraocular pressure (IOP). MATERIALS AND METHODS:This prospective, randomized, masked-evaluator, parallel-group, multicenter study in the United States included patients with primary open angle glaucoma or ocular ...

    journal_title:Journal of glaucoma

    pub_type: 临床试验,杂志文章,多中心研究,随机对照试验

    doi:10.1097/01.ijg.0000151881.99607.4e

    authors: Camras CB,Sheu WP,United States Latanoprost-Brimonidine Study Group.

    更新日期:2005-04-01 00:00:00

  • Results of CO2 Laser-assisted Deep Sclerectomy as Compared With Conventional Deep Sclerectomy.

    abstract:PURPOSE:To evaluate the efficacy of CO2 laser-assisted sclerectomy surgery (CLASS) compared with classic nonpenetrating deep sclerectomy (NPDS) with implant in medically uncontrolled glaucoma patients. MATERIALS AND METHODS:Patients who underwent primary filtration surgery with CO2 laser system at the time interval be...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000000187

    authors: Greifner G,Roy S,Mermoud A

    更新日期:2016-07-01 00:00:00

  • Detecting early functional damage in glaucoma suspect and ocular hypertensive patients with the multifocal VEP technique.

    abstract:PURPOSE:To determine whether the multifocal visual evoked potential (mfVEP) technique can detect early functional damage in ocular hypertensive (OHT) and glaucoma suspect (GS) patients with normal standard achromatic automated perimetry (SAP) results. PATIENTS AND METHODS:Twenty-five GS patients (25 eyes), 25 patients...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/01.ijg.0000212237.26466.0e

    authors: Thienprasiddhi P,Greenstein VC,Chu DH,Xu L,Liebmann JM,Ritch R,Hood DC

    更新日期:2006-08-01 00:00:00

  • Use of Intravitreal Bevacizumab for the Treatment of Secondary Glaucoma Caused by Metastatic Iris Tumor.

    abstract:PURPOSE:The purpose of this article was to report the efficacy of intravitreal bevacizumab to resolve secondary angle-closure glaucoma caused by biliary tract carcinoma metastasis to the iris. MATERIALS AND METHODS:A 52-year-old white woman who was under systemic chemotherapy for biliary tract carcinoma presented with...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000000959

    authors: Aydin R,Tezel TH

    更新日期:2018-06-01 00:00:00