Extrusion and Breakage of XEN Gel Stent Resulting in Endophthalmitis.

Abstract:

:The mainstay of open-angle glaucoma surgery involves subconjunctival drainage of aqueous fluid. Insertion of the XEN Gel Stent leads to formation of a subconjunctival bleb to assist in the drainage of aqueous fluid and offers the advantage of ease and speed of insertion with conjunctival sparing over traditional surgical techniques. This is the first case of XEN Gel Stent-related endophthalmitis associated with extrusion and breakage of the stent, a previously undocumented complication of this relatively new surgery.

journal_name

J Glaucoma

journal_title

Journal of glaucoma

authors

Lapira M,Cronbach N,Shaikh A

doi

10.1097/IJG.0000000000001058

subject

Has Abstract

pub_date

2018-10-01 00:00:00

pages

934-935

issue

10

eissn

1057-0829

issn

1536-481X

journal_volume

27

pub_type

杂志文章
  • Four Questions for Every Clinician Diagnosing and Monitoring Glaucoma.

    abstract::We pose 4 questions for the clinician diagnosing and monitoring glaucoma, and supply evidence-based answers. The first question is: "When do you perform a 10-2 (2-degree grid) visual field (VF) test?" We argue the best answer is: anyone you would do, or have done, a 24-2 (6-degree grid) VF on should have both a 24-2 a...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000001010

    authors: Hood DC,De Moraes CG

    更新日期:2018-08-01 00:00:00

  • Streptococcus intermedius-associated late-onset endophthalmitis after trabeculectomy with adjunctive mitomycin C.

    abstract:PURPOSE:To report a woman with congenital rubella syndrome of delayed-onset, bleb-related endophthalmitis induced by Streptococcus intermedius. METHODS:Interventional case report. RESULTS:A 33-year-old woman who underwent bilateral trabeculectomy with adjunctive mitomycin C, 11 years earlier presented with redness an...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0b013e318170a732

    authors: Mochizuki K,Kumada M,Suemori S,Kawakami H,Sawada A,Yamamoto T,Mikamo H

    更新日期:2009-01-01 00:00:00

  • A comparative study between diode laser cyclophotocoagulation and the Ahmed glaucoma valve implant in neovascular glaucoma: a long-term follow-up.

    abstract:BACKGROUND:To compare the efficacy, safety, and long-term results of intraocular pressure (IOP) reduction by diode laser contact cyclophotocoagulation (DCPC) and Ahmed glaucoma valve (AGV) implant in cases of neovascular glaucoma. METHODS:A total of 66 eyes of 66 patients with neovascular glaucoma were prospectively a...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0b013e31817d235c

    authors: Yildirim N,Yalvac IS,Sahin A,Ozer A,Bozca T

    更新日期:2009-03-01 00:00:00

  • Effects of bunazosin hydrochloride on ciliary muscle constriction and matrix metalloproteinase activities.

    abstract:PURPOSE:To clarify the mechanism by which bunazosin hydrochloride (BZ), a selective alpha1-adrenoceptor antagonist, increases uveoscleral outflow. METHODS:The effects of BZ on matrix metalloproteinase (MMP) activities in cultured monkey ciliary muscle cells, and on phenylephrine hydrochloride-induced constriction in b...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/00061198-200408000-00009

    authors: Akaishi T,Takagi Y,Matsugi T,Ishida N,Hara H,Kashiwagi K

    更新日期:2004-08-01 00:00:00

  • Mask-induced Artifact Impacts Intraocular Pressure Measurement Using Goldmann Applanation Tonometry.

    abstract:PURPOSE:The coronavirus (COVID-19) pandemic has impacted ophthalmology practices significantly. American Academy of Ophthalmology and Center for Disease Control guidelines suggest mandatory masking of patients and physicians during outpatient visits. We have recently become aware of a mask-induced phenomenon, whereby t...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000001746

    authors: Davanian AM,Donahue SP,Mogil RS,Groth SL

    更新日期:2020-12-02 00:00:00

  • Decreased cardiovagal regulation in exfoliation syndrome.

    abstract:PURPOSE:To investigate the parasympathetic cardiovascular regulation, baroreflex sensitivity (BRS), and pulse wave velocity (PWV) in exfoliation syndrome (XFS). METHODS:Heart rate variability indices [standard deviation of all RR intervals (SDNN); the mean of absolute successive differences (RMSSD); the percentage of ...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0b013e3181379d67

    authors: Visontai Z,Horváth T,Kollai M,Holló G

    更新日期:2008-03-01 00:00:00

  • A Comparative Analysis of Goldmann Tonometry Correction.

    abstract:PURPOSE:The measurement of intraocular pressure (IOP) by Goldmann applanation tonometry (GAT) is based on assumptions about corneal parameters. To correct for variations in corneal curvature and thickness, a number of equations have been proposed. This study evaluates the in vivo accuracy of these equations from indivi...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000000588

    authors: Asejczyk-Widlicka M,Srodka W,Pierscionek BK

    更新日期:2017-03-01 00:00:00

  • Evaluation of Blebs After Filtering Surgery With En-Face Anterior-Segment Optical Coherence Tomography: A Pilot Study.

    abstract:PURPOSE:To compare characteristics of functioning blebs (FBs) and nonfunctioning blebs (NFBs) with en-face spectral-domain optical coherence tomography (OCT). METHODS:We evaluated 41 blebs of 38 patients after a first-time trabeculectomy. Eyes were classified into 2 groups: FBs (22 eyes) and NFBs (19 eyes). En-face OC...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000000319

    authors: Meziani L,Tahiri Joutei Hassani R,El Sanharawi M,Brasnu E,Liang H,Hamard P,Baudouin C,Labbe A

    更新日期:2016-05-01 00:00:00

  • Early Clinical Results of a Novel Ab Interno Gel Stent for the Surgical Treatment of Open-angle Glaucoma.

    abstract:PURPOSE:To evaluate the intraocular pressure (IOP) lowering effect of the XEN140 microfistula gel stent implant for the surgical treatment of open-angle glaucoma. PATIENTS AND METHODS:Forty-nine eyes of 49 patients with an IOP>18 mm Hg and ≤35 mm Hg were studied in a prospective nonrandomized multicenter cohort trial ...

    journal_title:Journal of glaucoma

    pub_type: 临床试验,杂志文章,多中心研究

    doi:10.1097/IJG.0000000000000352

    authors: Sheybani A,Dick HB,Ahmed II

    更新日期:2016-07-01 00:00:00

  • Peripapillary focal retinal arteriolar narrowing in open angle glaucoma.

    abstract:PURPOSE:Optic disc photographs of 750 patients attending a glaucoma practice were examined to identify focal peripapillary arteriolar narrowing. METHODS:A subgroup of 110 of these patients' photographs, who had also had finger circulation tested for vasospasm to cold, were divided into patients with peripapillary foca...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:

    authors: Rankin SJ,Drance SM

    更新日期:1996-02-01 00:00:00

  • Radial Peripapillary Capillary Density Measurement Using Optical Coherence Tomography Angiography in Early Glaucoma.

    abstract:PURPOSE:The purpose of the study was to compare radial peripapillary capillary (RPC) density between normal subjects and patients with early primary open-angle glaucoma (POAG) using optical coherence tomography angiography (OCT-A). MATERIALS AND METHODS:A total of 24 patients with early POAG and age-matched 52 normal ...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000000649

    authors: Mansoori T,Sivaswamy J,Gamalapati JS,Balakrishna N

    更新日期:2017-05-01 00:00:00

  • Effects of tranilast on filtering blebs: a pilot study.

    abstract:PURPOSE:To investigate the effects of topical instillation of 0.5% tranilast eye drops on intraocular pressure (IOP) and bleb formation after glaucoma filtering surgery. PATIENTS AND METHODS:This was a prospective, randomized, double-masked, and controlled clinical trial. A total of 52 eyes of 52 patients were randoml...

    journal_title:Journal of glaucoma

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1097/00061198-200204000-00008

    authors: Chihara E,Dong J,Ochiai H,Hamada S

    更新日期:2002-04-01 00:00:00

  • Clinical Evaluation of Methods to Correct Intraocular Pressure Measurements by the Goldmann Applanation Tonometer, Ocular Response Analyzer, and Corvis ST Tonometer for the Effects of Corneal Stiffness Parameters.

    abstract:PURPOSE:To evaluate the effectiveness of methods to correct intraocular pressure (IOP) measurements obtained using the Goldmann applanation tonometer (GAT), the ocular response analyzer (ORA), and the Corvis ST tonometer (CVS) for the effects of corneal stiffness parameters: central corneal thickness (CCT), corneal cur...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000000359

    authors: Bao F,Huang Z,Huang J,Wang J,Deng M,Li L,Yu A,Wang Q,Elsheikh A

    更新日期:2016-06-01 00:00:00

  • Clinical Efficacy and Safety Outcomes of Micropulse Trans-Scleral Diode Cyclophotocoagulation in Patients with Advanced Glaucoma.

    abstract:PRECIS:Micropulse trans-scleral cyclophotocoagulation is only moderately effective in lowering intraocular pressure and useful as an adjunct procedure to other glaucoma surgeries. There was a small risk of loss of vision, prolonged hypotony and phthisis bulbi. AIMS:To determine the efficacy and safety of a single micr...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000001729

    authors: Lim JYE,Cecilia AM,Lim KAD,Sng C,Loon SC,Lun WXK,Chew TKP,Koh TCV

    更新日期:2020-10-29 00:00:00

  • Glycomics, extracellular matrix, and anti-glycan antibodies in exfoliation syndrome.

    abstract::Exfoliation syndrome (XFS) is considered to be a disease of extracellular matrix. Here we review key experimental evidence of aberrations in structure, expression, and function of glycoproteins, complex carbohydrates, and glycosaminoglycans found in extracellular matrix components forming exfoliation material in patie...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章,评审

    doi:10.1097/IJG.0000000000000118

    authors: Huflejt ME,Preiss JS,Thomson JE,Gils IM,Vuskovic MI

    更新日期:2014-10-01 00:00:00

  • Phacoemulsification and intraocular lens implantation before, during, or after canaloplasty in eyes with open-angle glaucoma: 3-year results.

    abstract:PURPOSE:To report 3-year results evaluating the effect on safety and efficacy of canaloplasty to treat open-angle glaucoma when combined with cataract surgery. PATIENTS AND METHODS:This was a retrospective subset analysis of a prospective, international, multicenter study evaluating 133 eyes of 133 adult, open-angle g...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章,多中心研究

    doi:10.1097/IJG.0b013e318285ff13

    authors: Tetz M,Koerber N,Shingleton BJ,von Wolff K,Bull H,Samuelson TW,Lewis RA

    更新日期:2015-03-01 00:00:00

  • Outcomes of Trabeculectomy With Mitomycin-C in Uveitis Associated With Vogt-Koyanagi-Harada Disease.

    abstract:OBJECTIVES:To evaluate the outcomes of trabeculectomy with mitomycin-C (MMC) in uveitis associated with Vogt-Koyanagi-Harada disease (VKH). METHODS:Retrospective cohort study included 27 eyes of 15 patients with uveitic glaucoma associated with VKH disease who underwent trabeculectomy with MMC as a first glaucoma proc...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000000384

    authors: Almobarak FA,Alharbi AH,Morales J,Aljadaan I

    更新日期:2016-06-01 00:00:00

  • Development of a fully automated peripheral anterior chamber depth analyzer and evaluation of its accuracy.

    abstract:PURPOSE:The aim of this study was to improve the scanning peripheral anterior chamber depth analyzer (SPAC) for measuring anterior chamber depth (ACD), differentiating eyes with shallow anterior chamber, and automatically categorizing eyes into subgroups based on the ACD values. We also investigated its accuracy for me...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/01.ijg.0000212256.25573.44

    authors: Kashiwagi K,Shinbayashi E,Tsukahara S

    更新日期:2006-10-01 00:00:00

  • Acute and chronic ocular symptoms of dorzolamide 2% compared with placebo.

    abstract:PURPOSE:To characterize and compare the ocular comfort and symptoms of dorzolamide and tear-replacement drops (placebo) in healthy volunteers. PATIENTS AND METHODS:Subjects were randomized in a double-masked fashion to receive each medicine for 6 days twice daily. Patients used a visual analog scale to assess the qual...

    journal_title:Journal of glaucoma

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1097/00061198-200304000-00010

    authors: Stewart WC,Stewart JA,Leech JN

    更新日期:2003-04-01 00:00:00

  • The Effect of Labor on the Intraocular Pressure in Healthy Women.

    abstract:PURPOSE:To investigate the effect of modern vaginal labor using epidural anesthesia on the intraocular pressure (IOP) and on the mean ocular perfusion pressure (MOPP) in healthy women. PATIENTS AND METHODS:In this prospective observational study, eligible candidates were healthy pregnant women for vaginal delivery wit...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000000559

    authors: Meshi A,Armarnik S,Mimouni M,Segev F,Segal O,Kaneti H,Assia EI,Geffen N

    更新日期:2017-01-01 00:00:00

  • Meibomian Gland Features and Conjunctival Goblet Cell Density in Glaucomatous Patients Controlled With Prostaglandin/Timolol Fixed Combinations: A Case Control, Cross-sectional Study.

    abstract:PURPOSE:To investigate, using in vivo confocal microscopy (IVCM), the Meibomian gland (MG) features and conjunctival goblet cell density (GCD) in glaucomatous patients controlled with prostaglandin/timolol fixed combinations (PTFCs). MATERIALS AND METHODS:In this cross-sectional study, 60 white patients were treated w...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000000899

    authors: Agnifili L,Mastropasqua R,Fasanella V,Brescia L,Scatena B,Oddone F,Mastropasqua L

    更新日期:2018-04-01 00:00:00

  • Changes in retinal nerve fiber layer thickness after optic disc hemorrhage in glaucomatous eyes.

    abstract:PURPOSE:The aim of this study was to investigate the changes in longitudinal retinal nerve fiber layer thickness (RNFLT) as determined by spectral-domain optical coherence tomography (OCT) after optic disc hemorrhage (DH) in glaucomatous eyes. METHODS:A total of 65 eyes with unilateral DH and 65 contralateral eyes wit...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000000083

    authors: Hwang YH,Kim YY,Kim HK,Sohn YH

    更新日期:2014-10-01 00:00:00

  • Transconjunctival mitomycin C as an adjunct to conventional glaucoma filtration surgery in rabbits.

    abstract:PURPOSE:Subconjunctival mitomycin C has been used in glaucoma filtration surgery with success. A prospective, randomized, masked, placebo-controlled study was performed to evaluate whether single transconjunctival mitomycin C applied either preoperatively or postoperatively would enhance the success of filtration surge...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:

    authors: Buffenn AN,Saetre SB,Higginbotham EJ,Musch DC,Kincaid MC

    更新日期:1997-10-01 00:00:00

  • Macular and retinal nerve fiber layer thickness measurement reproducibility using optical coherence tomography (OCT-3).

    abstract:PURPOSE:To assess the reproducibility of retinal nerve fiber layer thickness and macular thickness measurements using OCT-3. METHODS:Randomly chosen eyes of healthy individuals were scanned following pupillary dilation by two trained operators (RGO, RV) using OCT-3 (software version A1.1, Carl Zeiss Meditec, Inc., Dub...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/00061198-200406000-00012

    authors: Gürses-Ozden R,Teng C,Vessani R,Zafar S,Liebmann JM,Ritch R

    更新日期:2004-06-01 00:00:00

  • Trabeculectomy Following Failed Ab Interno Gelatin Microstent: Case Series.

    abstract:PURPOSE:The purpose of this study is to describe the outcomes of mitomycin C (MMC)-augmented trabeculectomy performed following a failed MMC-augmented XEN-45 implantation. DESIGN:Retrospective case series. METHODS:All consecutive cases of MMC-augmented trabeculectomy performed after MMC-augmented XEN-45 in the Glauco...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000001000

    authors: Gizzi C,Mohamed-Noriega J,Elkarmouty A,Scott A

    更新日期:2018-10-01 00:00:00

  • Phaco-viscocanalostomy versus phaco-trabeculotomy: a middle-term study.

    abstract:PURPOSE:To compare the surgical outcomes between phaco-viscocanalostomy and phaco-trabeculotomy in open-angle glaucoma. PATIENTS AND METHODS:In a nonrandomized, retrospective clinical study, 110 eyes underwent phaco-viscocanalostomy (VCS group), and 110 eyes underwent phaco-trabeculotomy (LOT group). The mean follow-u...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/01.ijg.0000212265.96864.77

    authors: Park M,Hayashi K,Takahashi H,Tanito M,Chihara E

    更新日期:2006-10-01 00:00:00

  • Proline-assisted Tube Insertion Through Sulcus in Ahmed Valve.

    abstract::To prevent corneal endothelial cell loss, ciliary sulcus tube insertion is preferred for the pseudophakic eye. However, we sometimes encounter technical difficulties when inserting the tube through the sulcus. Even in cases in which we are able to insert a 23-G needle through the sulcus into the space between the iris...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章

    doi:10.1097/IJG.0000000000001602

    authors: Kasuga T,Asaoka S,Asada Y,Iwamoto S,Hirakata T,Honda R,Ohta T,Matsuda A

    更新日期:2020-09-01 00:00:00

  • Accuracy of Measurements With the iCare HOME Rebound Tonometer.

    abstract:PURPOSE:To evaluate the accuracy of intraocular pressure (IOP) measurements obtained with the newly available iCare HOME (RTHOME) rebound tonometer compared with the iCare ONE (RTONE) tonometer and Goldmann applanation tonometry (GAT), and possible correlation with central corneal thickness (CCT). MATERIALS AND METHOD...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章,随机对照试验

    doi:10.1097/IJG.0000000000000390

    authors: Termühlen J,Mihailovic N,Alnawaiseh M,Dietlein TS,Rosentreter A

    更新日期:2016-06-01 00:00:00

  • Prostaglandin efficacy and safety study undertaken by race (the PRESSURE study).

    abstract:PURPOSE:Latanoprost, travoprost, and bimatoprost are prostaglandin or prostamide-type ocular hypotensive medications, all of which are effective and safe for lowering intraocular pressure (IOP). Most studies with these types of drugs have included patients mainly from European or white ethnic backgrounds; however, some...

    journal_title:Journal of glaucoma

    pub_type: 杂志文章,多中心研究,随机对照试验

    doi:10.1097/IJG.0b013e3181c4aeac

    authors: Birt CM,Buys YM,Ahmed II,Trope GE,Toronto Area Glaucoma Society.

    更新日期:2010-09-01 00:00:00

  • Optic nerve head circulation after topical calcium channel blocker.

    abstract:PURPOSE:Our purpose was to investigate the effects of the calcium channel blocker verapamil on intraocular pressure and blood circulation in the human optic nerve head. METHODS:The effects of three different concentrations of topical verapamil (0.063%, 0.125%, and 0.25%) on intraocular pressure and optic nerve head ca...

    journal_title:Journal of glaucoma

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:

    authors: Netland PA,Feke GT,Konno S,Goger DG,Fujio N

    更新日期:1996-06-01 00:00:00