Estimation of temporal gait parameters using Bayesian models on acceleration signals.

Abstract:

:The purpose of this study is to develop a system capable of performing calculation of temporal gait parameters using two low-cost wireless accelerometers and artificial intelligence-based techniques as part of a larger research project for conducting human gait analysis. Ten healthy subjects of different ages participated in this study and performed controlled walking tests. Two wireless accelerometers were placed on their ankles. Raw acceleration signals were processed in order to obtain gait patterns from characteristic peaks related to steps. A Bayesian model was implemented to classify the characteristic peaks into steps or nonsteps. The acceleration signals were segmented based on gait events, such as heel strike and toe-off, of actual steps. Temporal gait parameters, such as cadence, ambulation time, step time, gait cycle time, stance and swing phase time, simple and double support time, were estimated from segmented acceleration signals. Gait data-sets were divided into two groups of ages to test Bayesian models in order to classify the characteristic peaks. The mean error obtained from calculating the temporal gait parameters was 4.6%. Bayesian models are useful techniques that can be applied to classification of gait data of subjects at different ages with promising results.

authors

López-Nava IH,Muñoz-Meléndez A,Pérez Sanpablo AI,Alessi Montero A,Quiñones Urióstegui I,Núñez Carrera L

doi

10.1080/10255842.2015.1032945

subject

Has Abstract

pub_date

2016-01-01 00:00:00

pages

396-403

issue

4

eissn

1025-5842

issn

1476-8259

journal_volume

19

pub_type

杂志文章
  • Computational biomechanical analysis of postoperative inferior tibiofibular syndesmosis: a modified modeling method.

    abstract::To analyze the biomechanical effect of syndesmotic screw through three and four cortices, a total of 12 finite element models simulating healthy ankles, tibiofibular syndesmosis injured ankles, and post-operative ankles by screw fixations through three or four cortices were built. A set of biomechanical data were obta...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2018.1472770

    authors: Li H,Chen Y,Qiang M,Zhang K,Jiang Y,Zhang Y,Jia X

    更新日期:2018-04-01 00:00:00

  • The influence of the way the muscle force is modeled on the predicted results obtained by solving indeterminate problems for a fast elbow flexion.

    abstract::A critical point in models of the human limbs when the aim is to investigate the motor control is the muscle model. More often the mechanical output of a muscle is considered as one musculotendon force that is a design variable in optimization tasks solved predominantly by static optimization. For dynamic conditions, ...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/1025584031000149097

    authors: Raikova R,Aladjov H

    更新日期:2003-06-01 00:00:00

  • Flow-induced wall shear stress in abdominal aortic aneurysms: Part I--steady flow hemodynamics.

    abstract::Numerical predictions of blood flow patterns and hemodynamic stresses in Abdominal Aortic Aneurysms (AAAs) are performed in a two-aneurysm, axisymmetric, rigid wall model using the spectral element method. Homogeneous, Newtonian blood flow is simulated under steady conditions for the range of Reynolds numbers 10 < or ...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/1025584021000009742

    authors: Finol EA,Amon CH

    更新日期:2002-08-01 00:00:00

  • A neurofuzzy inference system based on biomechanical features for the evaluation of the effects of physical training.

    abstract::The current study aimed to evaluate physical training effects. For this purpose, a classifier was implemented by taking into account biomechanical features selected from force-plate measurements and a neurofuzzy algorithm for data management and relevant decision-making. Measurements included two sets of sit-to-stand ...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章,随机对照试验

    doi:10.1080/10255840701550915

    authors: Vannozzi G,Pecoraro F,Caserotti P,Cappozzo A

    更新日期:2008-02-01 00:00:00

  • The effect of direct and indirect force transmission on peri-implant bone stress - a contact finite element analysis.

    abstract::In almost all finite element (FE) studies in dentistry, virtual forces are applied directly to dentures. The purpose of this study was to develop a FE model with non-linear contact simulation using an antagonist as force transmitter and to compare this with a similar model that uses direct force transmission. Furtherm...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2017.1338691

    authors: Rand A,Stiesch M,Eisenburger M,Greuling A

    更新日期:2017-08-01 00:00:00

  • Non-Newtonian flow-induced deformation from pressurized cavities in absorbing porous tissues.

    abstract::We investigate the behavior of a spherical cavity in a soft biological tissue modeled as a deformable porous material during an injection of non-Newtonian fluid that follows a power law model. Fluid flows into the neighboring tissue due to high cavity pressure where it is absorbed by capillaries and lymphatics at a ra...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2017.1376323

    authors: Ahmed A,Siddique JI,Mahmood A

    更新日期:2017-10-01 00:00:00

  • Simulation of swallowing dysfunction and mechanical ventilation after a Montgomery T-tube insertion.

    abstract::The Montgomery T-tube is used as a combined tracheal stent and airway after laryngotracheoplasty, to keep the lumen open and prevent mucosal laceration from scarring. It is valuable in the management of upper and mid-tracheal lesions, while invaluable in long and multisegmental stenting lesions. Numerical simulations ...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2014.930448

    authors: Trabelsi O,Malvè M,Mena Tobar A,Doblaré M

    更新日期:2015-01-01 00:00:00

  • Simulation of the behaviour of the L1 vertebra for different material properties and loading conditions.

    abstract::Three-dimensional finite element models of the thoracolumbar junction (T12-L2) and isolated L1 vertebra were developed to investigate the role of material properties and loading conditions on vertebral stresses and strains to predict fracture risk. The geometry of the vertebrae was obtained from computed tomography im...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2011.636741

    authors: Erdem I,Truumees E,van der Meulen MC

    更新日期:2013-01-01 00:00:00

  • Biomechanical assessment and clinical analysis of different intramedullary nailing systems for oblique fractures.

    abstract::The aim of this study is to evaluate the fracture union or non-union for a specific patient that presented oblique fractures in tibia and fibula, using a mechanistic-based bone healing model. Normally, this kind of fractures can be treated through an intramedullary nail using two possible configurations that depends o...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2015.1125473

    authors: Alierta JA,Pérez MA,Seral B,García-Aznar JM

    更新日期:2016-09-01 00:00:00

  • Does overlay preparation design affect polymerization shrinkage stress distribution? A 3D FEA study.

    abstract::This study evaluated the polymerization shrinkage stress of three tooth preparation designs for indirect ceramic overlay by finite element analysis: isthmus preparation (IST); without isthmus preparation (wIST); and non-retentive preparation (nRET). The models were created based in prepared dental typodonts and were d...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2020.1866561

    authors: de Andrade GS,Pinto ABA,Tribst JPM,Chun EP,Borges ALS,de Siqueira Ferreira Anzaloni Saavedra G

    更新日期:2021-01-07 00:00:00

  • A generic musculoskeletal model of the juvenile lower limb for biomechanical analyses of gait.

    abstract::The aim of this study was to develop a generic musculoskeletal model of a healthy 10-year-old child and examine the effects of geometric scaling on the calculated values of lower-limb muscle forces during gait. Subject-specific musculoskeletal models of five healthy children were developed from in vivo MRI data, and t...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2020.1817405

    authors: Hainisch R,Kranzl A,Lin YC,Pandy MG,Gfoehler M

    更新日期:2020-09-17 00:00:00

  • A new musculoskeletal AnyBody™ detailed hand model.

    abstract::Musculoskeletal research questions regarding the prevention or rehabilitation of the hand can be addressed using inverse dynamics simulations when experiments are not possible. To date, no complete human hand model implemented in a holistic human body model has been fully developed. The aim of this work was to develop...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2020.1851367

    authors: Engelhardt L,Melzner M,Havelkova L,Fiala P,Christen P,Dendorfer S,Simon U

    更新日期:2020-12-10 00:00:00

  • A solution method for the determination of cardiac potential distributions with an alternating current source.

    abstract::A recently presented solution method for the bidomain model (Johnston et al. 2006), which involves the application of direct current for studying electrical potential in a slab of cardiac tissue, is extended here to allow the use of an applied alternating current. The advantage of using AC current, in a four-electrode...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255840701747594

    authors: Johnston BM,Johnston PR,Kilpatrick D

    更新日期:2008-06-01 00:00:00

  • A three-dimensional collagen-fiber network model of the extracellular matrix for the simulation of the mechanical behaviors and micro structures.

    abstract::The extracellular matrix (ECM) provides structural and biochemical support to cells and tissues, which is a critical factor for modulating cell dynamic behavior and intercellular communication. In order to further understand the mechanisms of the interactive relationship between cell and the ECM, we developed a three-...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2017.1321113

    authors: Dong S,Huang Z,Tang L,Zhang X,Zhang Y,Jiang Y

    更新日期:2017-07-01 00:00:00

  • Effect of exercise on blood flow through the aortic valve: a combined clinical and numerical study.

    abstract::The aim of this study was to measure the cardiac output and stroke volume for a healthy subject by coupling an echocardiogram Doppler (echo-Doppler) method with a fluid-structure interaction (FSI) simulation at rest and during exercise. Blood flow through aortic valve was measured by Doppler flow echocardiography. Aor...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2013.771179

    authors: Bahraseman HG,Hassani K,Navidbakhsh M,Espino DM,Sani ZA,Fatouraee N

    更新日期:2014-01-01 00:00:00

  • Modelling the glycocalyx-endothelium-erythrocyte interaction in the microcirculation: a computational study.

    abstract::A novel, coarse-grained, single-framework 'Eulerian' model for blood flow in the microvascular circulation is presented and used to estimate the variations in flow properties that accrue from all of the following: (i) wall position variation, associated with the endothelial cells' (ECs) shape, (ii) glycocalyx layer (G...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2013.799146

    authors: Pontrelli G,Halliday I,Spencer TJ,König CS,Collins MW

    更新日期:2015-01-01 00:00:00

  • Numerical investigation of oxygen mass transfer in a helical-type artery bypass graft.

    abstract::Local oxygen lack in arterial walls (hypoxia) plays a very important role in the initiation, progression and development of intimal hyperplasia (IH) and thrombosis. Aiming to find out whether a helical-type artery bypass graft (ABG) is hypoxia beneficial, a numerical study was carried out to compare oxygen transport b...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2012.702764

    authors: Zheng T,Wen J,Jiang W,Deng X,Fan Y

    更新日期:2014-04-01 00:00:00

  • Using the finite element method to model the biomechanics of the asymmetric mandible before, during and after skeletal correction by distraction osteogenesis.

    abstract::An approach was developed to evaluate the load transfer mechanism in the temporomandibular joint (TMJ) area before, during and after mandibular ramus elongation by distraction osteogenesis (DO). In a concerted approach using computer tomography, magnetic resonance imaging (MRI), and finite element analysis, three-dime...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255840500237953

    authors: Cattaneo PM,Kofod T,Dalstra M,Melsen B

    更新日期:2005-06-01 00:00:00

  • The influence of musculoskeletal forces on the growth of the prenatal cortex in the ilium: a finite element study.

    abstract::Remodelling and adaptation of bone within the pelvis is believed to be influenced by the mechanical strains generated during locomotion. Variation in the cortical bone thickness observed in the prenatal ilium has been linked to the musculoskeletal loading associated with in utero movements; for example the development...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2020.1777546

    authors: Watson PJ,Fagan MJ,Dobson CA

    更新日期:2020-10-01 00:00:00

  • Simulations of the contractile cycle in cell migration using a bio-chemical-mechanical model.

    abstract::Cell migration relies on traction forces in order to propel a cell. Several computational models have been developed that help explain the trajectory that cells take during migration, but little attention has been placed on traction forces during this process. Here, we investigated the spatiotemporal dynamics of cell ...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2011.554412

    authors: Han SJ,Sniadecki NJ

    更新日期:2011-05-01 00:00:00

  • Estimation of ligament strains and joint moments in the ankle during a supination sprain injury.

    abstract::This study presents the ankle ligament strains and ankle joint moments during an accidental injury event diagnosed as a grade I anterior talofibular ligament (ATaFL) sprain. A male athlete accidentally sprained his ankle while performing a cutting motion in a laboratory setting. The kinematic data were input to a thre...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2013.792809

    authors: Wei F,Fong DT,Chan KM,Haut RC

    更新日期:2015-01-01 00:00:00

  • Understanding ageing effects using complexity analysis of foot-ground clearance during walking.

    abstract::Ageing influences gait patterns which in turn can affect the balance control of human locomotion. Entropy-based regularity and complexity measures have been highly effective in analysing a broad range of physiological signals. Minimum toe clearance (MTC) is an event during the swing phase of the gait cycle and is high...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2011.628943

    authors: Karmakar C,Khandoker A,Begg R,Palaniswami M

    更新日期:2013-01-01 00:00:00

  • Calibration of crushable foam plasticity models for synthetic bone material for use in finite element analysis of acetabular cup deformation and primary stability.

    abstract::Polyurethane (PU) foam is a material often used in biomechanical experiments and demands for the definition of crushable foam plasticity (CFP) in numerical simulations of the primary stability and deformation of implants, to describe the crushing behaviour appropriately. Material data of PU foams with five different d...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2018.1524884

    authors: Schulze C,Vogel D,Sander M,Bader R

    更新日期:2019-01-01 00:00:00

  • Numerical studies of the influence of various geometrical features of a multispiked connecting scaffold prototype on mechanical stresses in peri-implant bone.

    abstract::The multispiked connecting scaffold (MSC-scaffold) prototype is an essential innovation in the fixation of components of resurfacing arthroplasty (RA) endoprostheses, providing their entirely non-cemented and bone-tissue-preserving fixation in peri-articular bone. An FE study is proposed to evaluate the influence of g...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2018.1480759

    authors: Uklejewski R,Winiecki M,Patalas A,Rogala P

    更新日期:2018-07-01 00:00:00

  • A system for predicting and preventing work-related musculoskeletal disorders among dentists.

    abstract::Work-related musculoskeletal disorders (WMSDs) have become increasingly common among dentists and initiate a series of events that could result in a career ending. This study aims to construct a system for predicting and preventing WMSD among dentists. We used Bayesian network (BN) that describes the mutual relationsh...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2012.672565

    authors: Thanathornwong B,Suebnukarn S,Songpaisan Y,Ouivirach K

    更新日期:2014-01-01 00:00:00

  • The cushioning function of woodpecker's jaw apparatus during the pecking process.

    abstract::Woodpeckers can withstand a fierce impact during pecking without any brain injury. Although directly involved in the whole pecking, the role of the jaw apparatus played in the impact-resistant process of woodpeckers is still not fully clear. We employed finite element analysis, impact tests in vivo, and post-traumatic...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2020.1838489

    authors: Xu P,Ni Y,Lu S,Liu S,Zhou X,Fan Y

    更新日期:2021-01-13 00:00:00

  • Foot internal stress distribution during impact in barefoot running as function of the strike pattern.

    abstract::The aim of the present study is to examine the impact absorption mechanism of the foot for different strike patterns (rearfoot, midfoot and forefoot) using a continuum mechanics approach. A three-dimensional finite element model of the foot was employed to estimate the stress distribution in the foot at the moment of ...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2018.1480760

    authors: Morales-Orcajo E,Becerro de Bengoa Vallejo R,Losa Iglesias M,Bayod J,Barbosa de Las Casas E

    更新日期:2018-05-01 00:00:00

  • Numerical models of auto-regulation and blood flow in the cerebral circulation.

    abstract::A two-dimensional time-dependent computational fluid dynamics model of the Circle of Willis has been developed. To simulate, not only the peripheral resistance of the cerebrovascular tree but also its auto-regulation function, a new "active" boundary condition has been defined and developed using control theory to pro...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255840290032171

    authors: Ferrandez A,David T,Brown MD

    更新日期:2002-02-01 00:00:00

  • A reliability measure of protein-protein interactions and a reliability measure-based search engine.

    abstract::Many methods developed for estimating the reliability of protein-protein interactions are based on the topology of protein-protein interaction networks. This paper describes a new reliability measure for protein-protein interactions, which does not rely on the topology of protein interaction networks, but expresses bi...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2010.494039

    authors: Park B,Han K

    更新日期:2010-02-01 00:00:00

  • Numerical and experimental evaluation of TPMS Gyroid scaffolds for bone tissue engineering.

    abstract::The combination of computational methods with 3D printing allows for the control of scaffolds microstructure. Lately, triply periodic minimal surfaces (TPMS) have been used to design porosity-controlled scaffolds for bone tissue engineering (TE). The goal of this work was to assess the mechanical properties of TPMS Gy...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2019.1569638

    authors: Castro APG,Ruben RB,Gonçalves SB,Pinheiro J,Guedes JM,Fernandes PR

    更新日期:2019-05-01 00:00:00