Effect of exercise on blood flow through the aortic valve: a combined clinical and numerical study.

Abstract:

:The aim of this study was to measure the cardiac output and stroke volume for a healthy subject by coupling an echocardiogram Doppler (echo-Doppler) method with a fluid-structure interaction (FSI) simulation at rest and during exercise. Blood flow through aortic valve was measured by Doppler flow echocardiography. Aortic valve geometry was calculated by echocardiographic imaging. An FSI simulation was performed, using an arbitrary Lagrangian-Eulerian mesh. Boundary conditions were defined by pressure loads on ventricular and aortic sides. Pressure loads applied brachial pressures with (stage 1) and without (stage 2) differences between brachial, central and left ventricular pressures. FSI results for cardiac output were 15.4% lower than Doppler results for stage 1 (r = 0.999). This difference increased to 22.3% for stage 2. FSI results for stroke volume were undervalued by 15.3% when compared to Doppler results at stage 1 and 26.2% at stage 2 (r = 0.94). The predicted mean backflow of blood was 4.6%. Our results show that numerical methods can be combined with clinical measurements to provide good estimates of patient-specific cardiac output and stroke volume at different heart rates.

authors

Bahraseman HG,Hassani K,Navidbakhsh M,Espino DM,Sani ZA,Fatouraee N

doi

10.1080/10255842.2013.771179

subject

Has Abstract

pub_date

2014-01-01 00:00:00

pages

1821-34

issue

16

eissn

1025-5842

issn

1476-8259

journal_volume

17

pub_type

杂志文章
  • Multi-objective reliability based design optimization using Kriging surrogate model for cementless hip prosthesis.

    abstract::Design optimization for cementless hip prosthesis signifies one of the key topics of research to improve its performances. However, majority of the studies have not considered the presence of uncertainties while it has been shown that a deterministic optimization leads to an unreliable design. In this paper, a multi-o...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2020.1768247

    authors: Dammak K,El Hami A

    更新日期:2020-09-01 00:00:00

  • A system for predicting and preventing work-related musculoskeletal disorders among dentists.

    abstract::Work-related musculoskeletal disorders (WMSDs) have become increasingly common among dentists and initiate a series of events that could result in a career ending. This study aims to construct a system for predicting and preventing WMSD among dentists. We used Bayesian network (BN) that describes the mutual relationsh...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2012.672565

    authors: Thanathornwong B,Suebnukarn S,Songpaisan Y,Ouivirach K

    更新日期:2014-01-01 00:00:00

  • Multi-component modelling of human brain tissue: a contribution to the constitutive and computational description of deformation, flow and diffusion processes with application to the invasive drug-delivery problem.

    abstract::Human brain tissue is complex and multi-component in nature. It consists of an anisotropic hyperelastic solid material composed of tissue cells and blood vessel walls. Brain tissue is permeated by two viscous pore liquids, the interstitial fluid and the blood. Both liquids are mobile within the tissue and exhibit a si...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2013.853754

    authors: Ehlers W,Wagner A

    更新日期:2015-01-01 00:00:00

  • The non-linear response of a muscle in transverse compression: assessment of geometry influence using a finite element model.

    abstract::Most recent finite element models that represent muscles are generic or subject-specific models that use complex, constitutive laws. Identification of the parameters of such complex, constitutive laws could be an important limit for subject-specific approaches. The aim of this study was to assess the possibility of mo...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2011.564162

    authors: Gras LL,Mitton D,Crevier-Denoix N,Laporte S

    更新日期:2012-01-01 00:00:00

  • Finite element analysis as a tool for parametric prosthetic foot design and evaluation. Technique development in the solid ankle cushioned heel (SACH) foot.

    abstract::In this study, we developed an approach for prosthetic foot design incorporating motion analysis, mechanical testing and computer analysis. Using computer modeling and finite element analysis, a three-dimensional (3D), numerical foot model of the solid ankle cushioned heel (SACH) foot was constructed and analyzed base...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/1025584021000048974

    authors: Saunders MM,Schwentker EP,Kay DB,Bennett G,Jacobs CR,Verstraete MC,Njus GO

    更新日期:2003-02-01 00:00:00

  • Development and validation of a finite element model of a small female pedestrian.

    abstract::Pedestrians are the most vulnerable road user and represent about 23% of the road traffic deaths in the world. A finite element (FE) model corresponding to a 5th percentile female pedestrian (F05-PS) was developed by morphing the Global Human Body Models Consortium (GHBMC) 50th percentile male pedestrian (M50-PS) mode...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2020.1801652

    authors: Pak W,Meng Y,Schap J,Koya B,Gayzik FS,Untaroiu CD

    更新日期:2020-12-01 00:00:00

  • Artefact-reduced kinematics measurement using a geometric finger model with mixture-prior particle filtering.

    abstract::It is challenging to measure the finger's kinematics of underlying bones in vivo. This paper presents a new method of finger kinematics measurement, using a geometric finger model and several markers deliberately stuck on skin surface. Using a multiple-view camera system, the optimal motion parameters of finger model ...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2011.643467

    authors: Chang CW,Kuo LC,Jou IM,Su FC,Sun YN

    更新日期:2013-01-01 00:00:00

  • A solution method for the determination of cardiac potential distributions with an alternating current source.

    abstract::A recently presented solution method for the bidomain model (Johnston et al. 2006), which involves the application of direct current for studying electrical potential in a slab of cardiac tissue, is extended here to allow the use of an applied alternating current. The advantage of using AC current, in a four-electrode...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255840701747594

    authors: Johnston BM,Johnston PR,Kilpatrick D

    更新日期:2008-06-01 00:00:00

  • Biomechanical analysis of the anterior cervical fusion.

    abstract::This paper presents a biomechanical analysis of the cervical C5-C6 functional spine unit before and after the anterior cervical discectomy and fusion. The aim of this work is to study the influence of the medical procedure and its instrumentation on range of motion and stress distribution. First, a three-dimensional f...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2011.597351

    authors: Fernandes PC,Fernandes PR,Folgado JO,Levy Melancia J

    更新日期:2012-01-01 00:00:00

  • Development of a three-dimensional body shape model of young children for child restraint design.

    abstract::The design of child restraints is guided in part by anthropometric data describing the distributions of body dimensions of children. However, three-dimensional body shape data have not been available for children younger than three years of age. This study presents body shape models for children weighing 9-23 kg in a ...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2018.1521960

    authors: Jones MLH,Ebert SM,Reed MP,Klinich KD

    更新日期:2018-11-01 00:00:00

  • Computational biomechanical analysis of postoperative inferior tibiofibular syndesmosis: a modified modeling method.

    abstract::To analyze the biomechanical effect of syndesmotic screw through three and four cortices, a total of 12 finite element models simulating healthy ankles, tibiofibular syndesmosis injured ankles, and post-operative ankles by screw fixations through three or four cortices were built. A set of biomechanical data were obta...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2018.1472770

    authors: Li H,Chen Y,Qiang M,Zhang K,Jiang Y,Zhang Y,Jia X

    更新日期:2018-04-01 00:00:00

  • A computational prediction for the effective drug and stem cell treatment of human airway burns.

    abstract::Burns in the airway from inhaling hot gases lead to one of the most common causes of death in the United States. In order to navigate tissues with large burn areas, the velocity, temperature, and heat flux distributions throughout the human airway system are computed for the inhalation of hot air using the finite-elem...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2015.1105966

    authors: Park S

    更新日期:2016-01-01 00:00:00

  • Experimental parameter estimation method for nonlinear viscoelastic composite material models: an application on arterial tissue.

    abstract::This study is aimed at setting a method of experimental parameter estimation for large-deforming nonlinear viscoelastic continuous fibre-reinforced composite material model. Specifically, arterial tissue was investigated during experimental research and parameter estimation studies, due to medical, scientific and soci...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2012.666532

    authors: Sunbuloglu E,Bozdag E,Toprak T,Islak C

    更新日期:2013-01-01 00:00:00

  • Finite element analysis of peri-implant bone volume affected by stresses around Morse taper implants: effects of implant positioning to the bone crest.

    abstract:OBJECTIVES:The purpose of the present study was to evaluate the distribution and magnitude of stresses through the bone tissue surrounding Morse taper dental implants at different positioning relative to the bone crest. MATERIALS AND METHODS:A mandibular bone model was obtained from a computed tomography scan. A three...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2018.1507025

    authors: Macedo JP,Pereira J,Faria J,Souza JCM,Alves JL,López-López J,Henriques B

    更新日期:2018-09-01 00:00:00

  • Using the finite element method to model the biomechanics of the asymmetric mandible before, during and after skeletal correction by distraction osteogenesis.

    abstract::An approach was developed to evaluate the load transfer mechanism in the temporomandibular joint (TMJ) area before, during and after mandibular ramus elongation by distraction osteogenesis (DO). In a concerted approach using computer tomography, magnetic resonance imaging (MRI), and finite element analysis, three-dime...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255840500237953

    authors: Cattaneo PM,Kofod T,Dalstra M,Melsen B

    更新日期:2005-06-01 00:00:00

  • A new musculoskeletal AnyBody™ detailed hand model.

    abstract::Musculoskeletal research questions regarding the prevention or rehabilitation of the hand can be addressed using inverse dynamics simulations when experiments are not possible. To date, no complete human hand model implemented in a holistic human body model has been fully developed. The aim of this work was to develop...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2020.1851367

    authors: Engelhardt L,Melzner M,Havelkova L,Fiala P,Christen P,Dendorfer S,Simon U

    更新日期:2020-12-10 00:00:00

  • Accuracy of femur reconstruction from sparse geometric data using a statistical shape model.

    abstract::Sparse geometric information from limited field-of-view medical images is often used to reconstruct the femur in biomechanical models of the hip and knee. However, the full femur geometry is needed to establish boundary conditions such as muscle attachment sites and joint axes which define the orientation of joint loa...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2016.1263301

    authors: Zhang J,Besier TF

    更新日期:2017-04-01 00:00:00

  • Role of differential adhesion in cell cluster evolution: from vasculogenesis to cancer metastasis.

    abstract::Cell-cell and cell-matrix adhesions are fundamental to numerous physiological processes, including angiogenesis, tumourigenesis, metastatic spreading and wound healing. We use cellular potts model to computationally predict the organisation of cells within a 3D matrix. The energy potentials regulating cell-cell (JCC) ...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2013.792917

    authors: Singh J,Hussain F,Decuzzi P

    更新日期:2015-01-01 00:00:00

  • Assessment of mechanical integrity for drug-eluting renal stent with micro-sized drug reservoirs.

    abstract::The drug-eluting stent (DES) has become the gold standard worldwide for the treatment of cardiovascular diseases. In recent years, an innovative variation of the DES with micro-sized drug reservoirs has been introduced. It allows programmable drug delivery with both spatial and temporal control and has several potenti...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2012.670851

    authors: Hsiao HM,Chiu YH

    更新日期:2013-01-01 00:00:00

  • Density-based load estimation using two-dimensional finite element models: a parametric study.

    abstract::A parametric investigation was conducted to determine the effects on the load estimation method of varying: (1) the thickness of back-plates used in the two-dimensional finite element models of long bones, (2) the number of columns of nodes in the outer medial and lateral sections of the diaphysis to which the back-pl...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255840600792451

    authors: Bona MA,Martin LD,Fischer KJ

    更新日期:2006-08-01 00:00:00

  • Oscillatory shear stress created by fluid pulsatility versus flexed specimen configurations.

    abstract::Oscillatory shear stress (OSS), caused by time-varying flow environments, may play a critical role in the production of engineered tissue by bone marrow-derived stem cells. This is particularly relevant in heart valve tissue engineering (HVTE), owing to the intense haemodynamic environments that surround native valves...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2012.715157

    authors: Salinas M,Schmidt DE,Libera M,Lange RR,Ramaswamy S

    更新日期:2014-05-01 00:00:00

  • Optimisation of solute transport in dialysers using a three-dimensional finite volume model.

    abstract::Dialyser manufacturers only provide limited information about mass removal under well-defined flow and solute conditions in commercially available dialysers for hemodialysis. This computational study aimed at assessing the solute transport efficiency in a dialyser for different geometries (fiber lengths and diameters)...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255840601002728

    authors: Eloot S,Vierendeels J,Verdonck P

    更新日期:2006-12-01 00:00:00

  • Foot internal stress distribution during impact in barefoot running as function of the strike pattern.

    abstract::The aim of the present study is to examine the impact absorption mechanism of the foot for different strike patterns (rearfoot, midfoot and forefoot) using a continuum mechanics approach. A three-dimensional finite element model of the foot was employed to estimate the stress distribution in the foot at the moment of ...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2018.1480760

    authors: Morales-Orcajo E,Becerro de Bengoa Vallejo R,Losa Iglesias M,Bayod J,Barbosa de Las Casas E

    更新日期:2018-05-01 00:00:00

  • Global/local head models to analyse cerebral blood vessel rupture leading to ASDH and SAH.

    abstract::Blunt and rotational head impacts due to vehicular collisions, falls and contact sports cause relative motion between the brain and skull. This increases the normal and shear stresses in the (skull/brain) interface region consisting of cerebrospinal fluid (CSF) and subarachnoid space (SAS) trabeculae. The relative mot...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255840903064897

    authors: Zoghi-Moghadam M,Sadegh AM

    更新日期:2009-02-01 00:00:00

  • Flexural and creep properties of human jaw compact bone for FEA studies.

    abstract::The aim of this work was to improve the constitutive model of the human mandible and dentition system by taking into account the non-linear material properties of the structural boney matrix that forms the human jaw bone or mandible. Due to the specific structure of the jaw bone the time dependence of the mechanical p...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255840310001637257

    authors: Vitins V,Dobelis M,Middleton J,Limbert G,Knets I

    更新日期:2003-10-01 00:00:00

  • A new training algorithm using artificial neural networks to classify gender-specific dynamic gait patterns.

    abstract::The aim of this study was to present a new training algorithm using artificial neural networks called multi-objective least absolute shrinkage and selection operator (MOBJ-LASSO) applied to the classification of dynamic gait patterns. The movement pattern is identified by 20 characteristics from the three components o...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2013.803081

    authors: Andrade A,Costa M,Paolucci L,Braga A,Pires F,Ugrinowitsch H,Menzel HJ

    更新日期:2015-01-01 00:00:00

  • The cushioning function of woodpecker's jaw apparatus during the pecking process.

    abstract::Woodpeckers can withstand a fierce impact during pecking without any brain injury. Although directly involved in the whole pecking, the role of the jaw apparatus played in the impact-resistant process of woodpeckers is still not fully clear. We employed finite element analysis, impact tests in vivo, and post-traumatic...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2020.1838489

    authors: Xu P,Ni Y,Lu S,Liu S,Zhou X,Fan Y

    更新日期:2021-01-13 00:00:00

  • Viscous flow through slowly expanding or contracting porous walls with low seepage Reynolds number: a model for transport of biological fluids through vessels.

    abstract::In this article, the problem of laminar, isothermal, incompressible and viscous flow in a rectangular domain bounded by two moving porous walls, which enable the fluid to enter or exit during successive expansions or contractions, is investigated. The governing non-linear equations and their associated boundary condit...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2010.497490

    authors: Dinarvand S

    更新日期:2011-10-01 00:00:00

  • Real-time technique for conversion of skin temperature into skin blood flow: human skin as a low-pass filter for thermal waves.

    abstract::Monitoring of skin blood flow oscillations related with mechanical activity of vessels is a very useful modality during diagnosis of peripheral hemodynamic disorders. In this study, we developed a new model and technique for real-time conversion of skin temperature into skin blood flow oscillations, and vice versa. Th...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2019.1615058

    authors: Sagaidachnyi A,Fomin A,Usanov D,Skripal A

    更新日期:2019-09-01 00:00:00

  • Influence of fluid-flow direction on effective permeability of the vertebral end plate: an analytical model.

    abstract::Convective transports in the vertebral end plate (VEP) play a significant role in the homeostasis of the spine. A few studies hypothesised that the hydraulic resistance or effective permeability of the VEP could be dependant upon fluid-flow direction. Results were influenced by species, region of interest within the e...

    journal_title:Computer methods in biomechanics and biomedical engineering

    pub_type: 杂志文章

    doi:10.1080/10255842.2010.518960

    authors: Swider P,Accadbled F,Laffosse JM,Sales de Gauzy J

    更新日期:2012-01-01 00:00:00