Evolution of precise and multimodal MRI and TRUS in detection and management of early prostate cancer.

Abstract:

:The combination of T2-weighted MRI with functional MRI, including contrast-enhanced MRI, diffusion-weighted imaging and magnetic resonance spectroscopy, has been recognized as the most promising diagnostic modality for the detection and staging of localized prostate cancer. In spite of the relatively low predictive value of the transrectal ultrasonography (US) image alone, transrectal US-guided prostate biopsy is currently the most clinically used, gold standard technique to confirm pathological prostate cancer. A possible way of improving the precision of prostate biopsy is to use computer-aided analysis, the fusion of the US image with MRI, or by introducing contrast-enhanced US, elastography and/or 3D US to be coupled with computer-assistance or robotic needle placement. Computer-aided surgical navigation systems with image-fusion or image-overlaying capability, integrated with real-time organ tracking systems and/or robotic systems for feedback on the 3D spatial positions of the surgical targets and instruments, can provide attractive opportunities to improve the digitally-coordinated precision of minimally invasive urology, along with predictive ability to guide toward ideal surgical outcomes.

journal_name

Expert Rev Med Devices

authors

Ukimura O

doi

10.1586/erd.10.24

subject

Has Abstract

pub_date

2010-07-01 00:00:00

pages

541-54

issue

4

eissn

1743-4440

issn

1745-2422

journal_volume

7

pub_type

杂志文章,评审
  • The Visible Heart® project and methodologies: novel use for studying cardiac monophasic action potentials and evaluating their underlying mechanisms.

    abstract:INTRODUCTION:This review describes the utilization of Visible Heart® methodologies for electrophysiologic studies, specifically in the investigation of monophasic action potential (MAP) recordings, with the aim to facilitate new catheter/device design and development that may lead to earlier diagnosis, treatment, and u...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2018.1493922

    authors: Schmidt MM,Iaizzo PA

    更新日期:2018-07-01 00:00:00

  • Right heart transcatheter valve therapies - a review of prostheses for the pulmonary and tricuspid positions.

    abstract::Minimally invasive, catheter-based treatment of valvular dysfunction has become an integral part of clinical routine. As left heart valvular disease is much more common and thus commercially of interest, transcatheter solutions for the treatment of aortic and mitral valvular defects were the first to become broadly cl...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2015.985654

    authors: Kuetting M,Pott D,Sedaghat A,Ng YA,Egron S,Rosefort C,Werner N,Sachweh J,Steinseifer U

    更新日期:2015-03-01 00:00:00

  • Devices for thoracic endovascular aortic repair of type B aortic dissection: is there any chance for Marfan syndrome?

    abstract:INTRODUCTION:Type B aortic dissection (TBAD) is a threatening event that may lead to death for aortic rupture or multivisceral malperfusion in the acute phase and offers a poor prognosis for long term survivors. Thoracic endovascular aortic repair (TEVAR) has become the preferential therapy in acute and chronic complic...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2020.1782735

    authors: Lovato L,Cefarelli M,Gatta E,Di Eusanio M,Fattori R

    更新日期:2020-07-01 00:00:00

  • Thermal scalpel to target cancer.

    abstract::Nanotechnology is increasingly applied to the field of medicine, particularly for the treatment of cancer. In this regard, gold nanoparticles can mediate hyperthermia induction and kill tumor cells upon laser irradiation, thereby functioning as a 'thermal scalpel'. Recent developments in gold nanoparticle design have ...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.4.2.131

    authors: Everts M

    更新日期:2007-03-01 00:00:00

  • Clinical potential of implantable wireless sensors for orthopedic treatments.

    abstract:INTRODUCTION:Implantable wireless sensors have been used for real-time monitoring of chemicals and physical conditions of bones, tendons and muscles to diagnose and study orthopedic diseases and injuries. Due to the importance of these sensors in orthopedic care, a critical review, which not only analyzes the underlyin...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2018.1454310

    authors: Karipott SS,Nelson BD,Guldberg RE,Ong KG

    更新日期:2018-04-01 00:00:00

  • Single-step atrial thrombus exclusion and transesophageal cardioversion in atrial fibrillation.

    abstract::Atrial fibrillation (AF), the most common arrhythmia, has a major impact on both patient morbidity and healthcare economics. Hospital admissions due to AF have risen by two-thirds in the last 20 years. This is due mainly to an aging population and an increasing prevalence of chronic heart disease. Strategies for the m...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.4.4.549

    authors: Mischke K,Schimpf T,Knackstedt C,Hanrath P,Schauerte P

    更新日期:2007-07-01 00:00:00

  • A critical appraisal of cardiac ablation technology for catheter-based treatment of atrial fibrillation.

    abstract::The advent of catheter ablation has revolutionized the treatment of supraventricular cardiac arrhythmias, including in the last few years, atrial fibrillation. The discovery of electrically active sleeves of atrial myocardium extending into the pulmonary veins has led to the development of pulmonary vein ostial ablati...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/erd.10.59

    authors: Shah D

    更新日期:2011-01-01 00:00:00

  • Laparoscopic cholecystectomy: device-related errors revealed through a national database.

    abstract::Laparoscopic techniques represent a key milestone in the development of modern surgery, offering a step change in quality of care, patient satisfaction and efficiency in use of health service resources. Laparoscopy is most widely used for gall bladder surgery. As would be expected with the introduction of any new tech...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/erd.11.43

    authors: Panesar SS,Salvilla SA,Patel B,Donaldson SL

    更新日期:2011-09-01 00:00:00

  • Potential of APDM mobility lab for the monitoring of the progression of Parkinson's disease.

    abstract::APDM's Mobility Lab system provides portable, validated, reliable, objective measures of balance and gait that are sensitive to Parkinson's disease (PD). In this review, we describe the potential of objective measures collected with the Mobility Lab system for tracking longitudinal progression of PD. Balance and gait ...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2016.1153421

    authors: Mancini M,Horak FB

    更新日期:2016-05-01 00:00:00

  • Device profile of the MobiusHD EVBA system for the treatment of resistant hypertension: overview of its mechanism of action, safety and efficacy.

    abstract:INTRODUCTION:Early promising results of renal nerve denervation awakened interest in developing medical device alternatives for patients with resistant hypertension. The subsequent sham-controlled renal nerve denervation randomized trials were disappointing leading researchers and innovators to explore alternative devi...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2020.1779054

    authors: Bates MC,Stone GW,Chen CY,Spiering W

    更新日期:2020-07-01 00:00:00

  • Surface coatings for ventricular assist devices.

    abstract::This article focuses on the surface engineering of ventricular assist devices (VADs) for the treatment of heart failure patients, which involves the modification of surfaces contacting blood in order to improve the blood compatibility (hemocompatibility) of the VADs. Following an introduction to the categorization and...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.6.1.51

    authors: Sin DC,Kei HL,Miao X

    更新日期:2009-01-01 00:00:00

  • Using haptic stimulation to enhance auditory perception in hearing-impaired listeners.

    abstract:INTRODUCTION:Hearing-assistive devices, such as hearing aids and cochlear implants, transform the lives of hearing-impaired people. However, users often struggle to locate and segregate sounds. This leads to impaired threat detection and an inability to understand speech in noisy environments. Recent evidence suggests ...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章

    doi:10.1080/17434440.2021.1863782

    authors: Fletcher MD

    更新日期:2020-12-29 00:00:00

  • Does CircuLite Synergy assist device as partial ventricular support have a place in modern management of advanced heart failure?

    abstract::The discrepancy between the number of patients on the waiting list and available donor hearts has led to the successful development of left ventricular assist devices (LVAD) as a bridge to transplantation. The conventional LVADs are designed to provide full hemodynamic support for the end-stage failing heart. However,...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2015.985208

    authors: Mohite PN,Sabashnikov A,Simon AR,Weymann A,Patil NP,Unsoeld B,Bireta C,Popov AF

    更新日期:2015-01-01 00:00:00

  • Evaluation of Surefire's precision direct-to-tumor embolization device to augment therapeutic response to intra-arterial, liver-directed therapies for patients with primary and secondary liver cancers.

    abstract::Patients with primary and secondary liver cancers generally have a poor prognosis with limited potentially curative options. Liver-directed, intra-arterial therapies such as selective internal radiotherapy (SIRT) and trans-arterial chemoembolization (TACE) are taking a larger role in the management of these patients. ...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章

    doi:10.1586/17434440.2016.1164594

    authors: Kim AY,Miller A

    更新日期:2016-05-01 00:00:00

  • Non-invasive imaging techniques to assess myocardial perfusion.

    abstract:INTRODUCTION:Coronary artery disease affecting myocardial perfusion continues to be the leading cause of cardiovascular morbidity and mortality worldwide. While invasive evaluation based on coronary angiography and flow measurements still is considered the reference technique for assessing myocardial perfusion, technol...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2020.1834844

    authors: Villemain O,Baranger J,Jalal Z,Lam C,Calais J,Pernot M,Cifra B,Friedberg MK,Mertens L

    更新日期:2020-11-01 00:00:00

  • Resurrection of hip resurfacing: what is the evidence?

    abstract::Total hip resurfacing has long been conceptually attractive to both surgeons and patients. However, historically it has been plagued by limited durability and marked acetabular bone loss. The recent development of wear-resistant bearings, such as metal-on-metal, has led to renewed interest in hip resurfacing in the or...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.3.6.755

    authors: Moroni A,Cadossi M,Bellenghi C,Romagnoli M,Bevoni R,Giannini S

    更新日期:2006-11-01 00:00:00

  • Amplatzer Duct Occluder device: a new technology for the closure of the moderate-to-large-sized patent ductus arteriosus.

    abstract::The Amplatzer Duct Occluder is a novel device designed to allow for the transcatheter closure of virtually all sized patent ductus arteriosuses. Prior technologies have been cumbersome and challenging to deploy with somewhat less than ideal closure rates associated with their use. This article summarizes the present k...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章

    doi:10.1586/17434440.3.3.291

    authors: Pass RH

    更新日期:2006-05-01 00:00:00

  • Performance of a new device for the clinical determination of light discomfort.

    abstract:PURPOSE:To assess the performance of a new device for the clinical determination of light discomfort on a large sample of healthy human subjects. METHODS:A total of 489 subjects ranging from 20 to 70 years old (241 men, 248 women) were evaluated with the LUMIZ™ 100 to determine light discomfort. Repeatability was asse...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章

    doi:10.1080/17434440.2020.1837623

    authors: Montés-Micó R,Cerviño A,Martínez-Albert N,García-Marqués JV,Marie S

    更新日期:2020-11-01 00:00:00

  • Cardiac rhythm management devices in a magnetic resonance environment.

    abstract::MRI is the gold standard diagnostic tool for soft tissue imaging for many specialties. An impressive body of research has proven the effectiveness of cardiac rhythm management devices (CRMDs) objectively, in terms of parameters that include patient's quality of life, morbidity, and mortality. However, interaction betw...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2014.882228

    authors: Fanourgiakis J,Kanoupakis E

    更新日期:2014-03-01 00:00:00

  • New developments in ureteral stent design, materials and coatings.

    abstract::Ureteral stents are used in a variety of urological diseases and procedures. The majority of patients with indwelling ureteral stents experience bothersome symptoms and are at increased risk for urinary tract infection. Stent encrustation and the associated complications can also result in significant patient morbidit...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.3.3.395

    authors: Chew BH,Duvdevani M,Denstedt JD

    更新日期:2006-05-01 00:00:00

  • Shields and garb for decreasing radiation exposure in the cath lab.

    abstract:INTRODUCTION:Decreasing radiation exposure of the cardiac catheterization laboratory staff is critical for minimizing radiation-related adverse outcomes and can be accomplished by decreasing patient dose and by shielding. Areas covered: protection from ionizing radiation can be achieved with architectural, equipment-mo...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2018.1510771

    authors: Karatasakis A,Brilakis ES

    更新日期:2018-09-01 00:00:00

  • Is there an alternative to systemic anticoagulation, as related to interventional biomedical devices?

    abstract::To reduce the toxic effects, related clinical problems and complications such as bleeding disorders associated with systemic anticoagulation, it has been hypothesized that by coating the surfaces of medical devices, such as stents, bypass grafts, extracorporeal circuits, guide wires and catheters, there will be a sign...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章

    doi:10.1586/17434440.3.2.245

    authors: Conn G,Kidane AG,Punshon G,Kannan RY,Hamilton G,Seifalian AM

    更新日期:2006-03-01 00:00:00

  • Ventricular assist devices for the failing univentricular circulation.

    abstract:INTRODUCTION:Improved survival following single ventricle palliation has led to a large population of patients with a univentricular circulation, many of whom develop heart failure. Increasing experience with ventricular assist devices (VAD) in children has paved the way for VAD support in those with failing univentric...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章

    doi:10.1080/17434440.2017.1332523

    authors: Buratto E,Shi WY,Ye XT,Konstantinov IE

    更新日期:2017-06-01 00:00:00

  • Does the novel delivery system for the STENTYS self-apposing coronary stent increase the risk of stent edge dissections? Optical coherence tomography post stent findings.

    abstract:BACKGROUND:With optical coherence tomography (OCT), details of arterial injuries during percutaneous coronary intervention can be assessed accurately. There might be an increased risk of stent edge dissections with the novel delivery system for the STENTYS stent. We evaluated the prevalence of stent edge dissections us...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章

    doi:10.1080/17434440.2018.1421942

    authors: Lu H,Kalkman DN,Grundeken MJ,Tijssen JGP,Wykrzykowska JJ,de Winter RJ,Koch KT

    更新日期:2018-02-01 00:00:00

  • In vivo nucleic acid delivery with PEI and its derivatives: current status and perspectives.

    abstract::Poly(ethylenimine) (PEI) has recently emerged as a favorable candidate for nucleic acid (NA) delivery because of its good effectivity at low cost. Despite copious derivatives and formulations being explored over the years, there is a scarcity of efforts to systematically review the current status and unmet needs of re...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/erd.10.83

    authors: Lai WF

    更新日期:2011-03-01 00:00:00

  • Robotic navigation during spine surgery.

    abstract::Introduction: Potential complications associated with screw malposition may result in neurological deficits or vascular injuries. Spine surgery has significantly developed under the assistance of technological progress. The advantages of applying robotic technology in spine surgery include the possibility of improving...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2020.1699405

    authors: Zhang Q,Han XG,Xu YF,Fan MX,Zhao JW,Liu YJ,He D,Tian W

    更新日期:2020-01-01 00:00:00

  • Device profile of the Resolute Onyx Zotarolimus eluting coronary stent system for the treatment of coronary artery disease: overview of its safety and efficacy.

    abstract::Introduction: The increasing complexity of patients undergoing percutaneous coronary intervention (PCI) regarding both coronary anatomy and comorbidities requires dedicated devices. The Resolute Onyx (R-Onyx, Medtronic, CA, USA) stent is a novel durable polymer zotarolimus-eluting stent (ZES) promising better delivera...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2020.1736037

    authors: Blum M,Cao D,Mehran R

    更新日期:2020-04-01 00:00:00

  • New developments in the delivery of cardiac resynchronization therapy: targeted lead placement, multi-site and endocardial pacing.

    abstract::Cardiac resynchronization therapy (CRT) is a proven treatment adjunct for selected patients with heart failure and evidence of ventricular dyssynchrony. When applying most contemporary guidelines the accepted response rate has remained static with up to one-third of patients failing to respond. Empiric lateral/postero...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2014.885320

    authors: Sohal M,Chen Z,Sammut E,Jackson T,Behar J,Carr-White G,Razavi R,Rinaldi CA

    更新日期:2014-05-01 00:00:00

  • Bacteriophage biosensors for antibiotic-resistant bacteria.

    abstract::An increasing number of disease-causing bacteria are resistant to one or more anti-bacterial drugs utilized for therapy. Early and speedy detection of these pathogens is therefore very important. Traditional pathogen detection techniques, that include microbiological and biochemical assays are long and labor-intensive...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2014.882767

    authors: Sorokulova I,Olsen E,Vodyanoy V

    更新日期:2014-03-01 00:00:00

  • The role of active middle-ear implants in the rehabilitation of hearing loss.

    abstract::The surgical implantation of auditory devices to improve or restore the sensation of hearing in affected individuals is a rapidly growing area of modern ear, nose and throat, and audiological practice. Following the enormous success of cochlear implantation and set to take an increasing role in the rehabilitation of d...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/erd.11.18

    authors: Green K

    更新日期:2011-07-01 00:00:00