Abstract:
:Introduction: Potential complications associated with screw malposition may result in neurological deficits or vascular injuries. Spine surgery has significantly developed under the assistance of technological progress. The advantages of applying robotic technology in spine surgery include the possibility of improving screw accuracy, reducing complications, decreasing fluoroscopy use.Areas covered: We critically evaluated the current literature on the radiographic and clinical outcomes of robotic-assisted spine surgery, including accuracy, radiation exposure, operative time, and complication rates.Expert opinion: Robotic-assisted spine surgery shows promising results and has the potentials for further investigations. The robot-assisted spine surgery is appeared to be more accurate in pedicle screw placement than the free-hand technique. In general, the robot-assisted technique is associated with shorter radiation exposure time but longer operative time than free-hand technique. For higher accuracy of robotic-assisted spine surgery, technical advancement and high-quality researches are needed. Artificial intelligent technology, decompression function, and higher accuracy are the directions for the development of robotic-assisted spine surgery.
journal_name
Expert Rev Med Devicesjournal_title
Expert review of medical devicesauthors
Zhang Q,Han XG,Xu YF,Fan MX,Zhao JW,Liu YJ,He D,Tian Wdoi
10.1080/17434440.2020.1699405subject
Has Abstractpub_date
2020-01-01 00:00:00pages
27-32issue
1eissn
1743-4440issn
1745-2422journal_volume
17pub_type
杂志文章,评审abstract:INTRODUCTION:This review describes the utilization of Visible Heart® methodologies for electrophysiologic studies, specifically in the investigation of monophasic action potential (MAP) recordings, with the aim to facilitate new catheter/device design and development that may lead to earlier diagnosis, treatment, and u...
journal_title:Expert review of medical devices
pub_type: 杂志文章,评审
doi:10.1080/17434440.2018.1493922
更新日期:2018-07-01 00:00:00
abstract::Patellofemoral arthroplasty has been utilized as a treatment for isolated patellofemoral arthritis for more than 30 years. However, the use of this procedure remains controversial, as many surgeons prefer to use total knee arthroplasty, even for isolated patellofemoral arthritis. While historically, the results with t...
journal_title:Expert review of medical devices
pub_type: 杂志文章
doi:10.1586/erd.09.53
更新日期:2010-01-01 00:00:00
abstract:INTRODUCTION:Mechanical circulatory support (MCS) is an increasingly utilized mode of therapy in the management of advanced heart failure, both as bridge to heart transplantation and destination therapy. As MCS becomes more prevalent, it is ever more important to understand the complex hemodynamics of these devices, as...
journal_title:Expert review of medical devices
pub_type: 杂志文章,评审
doi:10.1080/17434440.2017.1324292
更新日期:2017-05-01 00:00:00
abstract::Introduction: Cardiac arrest remains a worldwide health problem with very poor outcome. In the absence of bystander resuscitation, survival rates decrease by 10% per minute of arrest and global ischemia. Even the best manual chest compressions, however, can only produce a fraction of normal cardiac output and blood fl...
journal_title:Expert review of medical devices
pub_type: 杂志文章,评审
doi:10.1080/17434440.2019.1649135
更新日期:2019-09-01 00:00:00
abstract::The number and the types of electromagnetic emitters to which patients with active implantable medical devices (AIMD) are exposed to in their daily activities have proliferated over the last decade. Radiofrequency identification (RFID) is an example of wireless technology applied in many fields. The interaction betwee...
journal_title:Expert review of medical devices
pub_type: 杂志文章,评审
doi:10.1586/erd.12.5
更新日期:2012-05-01 00:00:00
abstract::An increasing number of disease-causing bacteria are resistant to one or more anti-bacterial drugs utilized for therapy. Early and speedy detection of these pathogens is therefore very important. Traditional pathogen detection techniques, that include microbiological and biochemical assays are long and labor-intensive...
journal_title:Expert review of medical devices
pub_type: 杂志文章,评审
doi:10.1586/17434440.2014.882767
更新日期:2014-03-01 00:00:00
abstract:INTRODUCTION:Decreasing radiation exposure of the cardiac catheterization laboratory staff is critical for minimizing radiation-related adverse outcomes and can be accomplished by decreasing patient dose and by shielding. Areas covered: protection from ionizing radiation can be achieved with architectural, equipment-mo...
journal_title:Expert review of medical devices
pub_type: 杂志文章,评审
doi:10.1080/17434440.2018.1510771
更新日期:2018-09-01 00:00:00
abstract::The number of outpatient surgical procedures performed in hospitals, increases daily. In some countries, such as Italy, outpatient operations outnumber inpatient operations. The incidence of thyroid disorders and, in particular, the cancer forms, has been increasing sharply for many years in several countries. Even if...
journal_title:Expert review of medical devices
pub_type: 杂志文章,评审
doi:10.1586/17434440.5.1.85
更新日期:2008-01-01 00:00:00
abstract::Robotic systems allow for mapping and ablation of different arrhythmia substrates replacing hand maneuvering of intracardiac catheters with machine steering. Currently there are four commercially available robotic systems. Niobe magnetic navigation system (Stereotaxis Inc., St Louis, MO) and Sensei robotic navigation ...
journal_title:Expert review of medical devices
pub_type: 杂志文章,评审
doi:10.1586/17434440.2014.916207
更新日期:2014-07-01 00:00:00
abstract::Left atrial appendage device occlusion for the preventions of systemic thromboembolism and stroke represents a major breakthrough in the field of cardiovascular disease. The wide prevalence of atrial fibrillation with devastating consequences of thromboembolic stroke as a result of thrombus arising from the left atria...
journal_title:Expert review of medical devices
pub_type: 杂志文章,评审
doi:10.1586/17434440.2014.940315
更新日期:2014-11-01 00:00:00
abstract::Atrial fibrillation is a pervasive and difficult heart rhythm problem for more than 3 million Americans. Patients are plagued by myriad symptoms and are exposed to the risk of stroke. Attempts to restore normal rhythm with drug therapy have been largely unsuccessful and the complications associated with long-term anti...
journal_title:Expert review of medical devices
pub_type: 杂志文章,评审
doi:10.1586/erd.09.9
更新日期:2009-05-01 00:00:00
abstract::Conventional hemostatic technologies utilized in thyroid surgery include clamp-and-tie, clips and monopolar and bipolar diathermy. Over the last decade, there has been a major shift towards utilizing newer hemostatic technologies, most notably the electrothermal bipolar vessel sealing systems (EBVS) and the Harmonic S...
journal_title:Expert review of medical devices
pub_type: 杂志文章,评审
doi:10.1586/erd.13.6
更新日期:2013-05-01 00:00:00
abstract::This article investigates various neural machine interfaces for voluntary control of externally powered upper-limb prostheses. Epidemiology of upper limb amputation, as well as prescription and follow-up studies of externally powered upper-limb prostheses are discussed. The use of electromyographic interfaces and peri...
journal_title:Expert review of medical devices
pub_type: 杂志文章,评审
doi:10.1586/17434440.4.1.43
更新日期:2007-01-01 00:00:00
abstract:INTRODUCTION:Percutaneous transcatheter balloon angioplasty has evolved to the current mainstay treatment for salvage of dysfunctional dialysis access. Nonetheless, it is frequently associated with recurrent vessel restenosis and the need for multiple repeat treatments in order to maintain hemodynamic patency. Cutting-...
journal_title:Expert review of medical devices
pub_type: 杂志文章,评审
doi:10.1080/17434440.2016.1254548
更新日期:2016-12-01 00:00:00
abstract::Drug-eluting stents are a major breakthrough in cardiology, with the Cypher (Cordis Corporation) and Taxus (Boston Scientific) stents preventing 60-70% of repeat coronary revascularizations, compared with bare metal stents. Both evidence- and risk-based application of drug-eluting stents is expected to create relevant...
journal_title:Expert review of medical devices
pub_type: 杂志文章,评审
doi:10.1586/17434440.1.1.49
更新日期:2004-09-01 00:00:00
abstract:BACKGROUND:With optical coherence tomography (OCT), details of arterial injuries during percutaneous coronary intervention can be assessed accurately. There might be an increased risk of stent edge dissections with the novel delivery system for the STENTYS stent. We evaluated the prevalence of stent edge dissections us...
journal_title:Expert review of medical devices
pub_type: 杂志文章
doi:10.1080/17434440.2018.1421942
更新日期:2018-02-01 00:00:00
abstract::Background: Papillary thyroid carcinoma is the most common type of thyroid cancer; despite its generally indolent course, patients often develop local post-operative recurrences. Re-operation, however, holds a high complication rate, while at the same time, not all patients benefit from radioiodine ablation. This syst...
journal_title:Expert review of medical devices
pub_type: 杂志文章
doi:10.1080/17434440.2021.1864323
更新日期:2020-12-29 00:00:00
abstract::Glaucoma is a leading cause of blindness worldwide. Currently, topical drops are the mainstay of treatment for patients who suffer from this chronic disease. Adherence to topical therapy is known to be affected by forgetfulness, frequent dosing requirements and physical limitations. Dosing and adherence aids are desig...
journal_title:Expert review of medical devices
pub_type: 杂志文章,评审
doi:10.1586/17434440.4.2.261
更新日期:2007-03-01 00:00:00
abstract::This paper discusses a new class of robots known as concentric tube robots and their application to transnasal skull base surgery. The endonasal approach has clear benefits for patients, but the surgery presents challenges that strongly motivate the use of robotic tools. In this paper, the concentric tube robot concep...
journal_title:Expert review of medical devices
pub_type: 社论
doi:10.1586/17434440.2013.854702
更新日期:2014-01-01 00:00:00
abstract::Transmyocardial revascularization, using the US FDA-approved holmium: yttrium-aluminum-garnet (Ho:YAG) laser system, is a surgical option for patients with debilitating angina caused by diffuse coronary artery disease in areas of the heart not amenable to complete revascularization using conventional treatments. Incre...
journal_title:Expert review of medical devices
pub_type: 杂志文章
doi:10.1586/17434440.3.2.137
更新日期:2006-03-01 00:00:00
abstract::Deep brain stimulation has emerged rapidly as an effective therapy for movement disorders. Deep brain stimulation includes an implanted brain electrode and a pacemaker-like implanted pulse generator. The clinical application of deep brain stimulation proceeded in the absence of clear understandings of its mechanisms o...
journal_title:Expert review of medical devices
pub_type: 杂志文章,评审
doi:10.1586/17434440.2.4.409
更新日期:2005-07-01 00:00:00
abstract::The advent of catheter ablation has revolutionized the treatment of supraventricular cardiac arrhythmias, including in the last few years, atrial fibrillation. The discovery of electrically active sleeves of atrial myocardium extending into the pulmonary veins has led to the development of pulmonary vein ostial ablati...
journal_title:Expert review of medical devices
pub_type: 杂志文章,评审
doi:10.1586/erd.10.59
更新日期:2011-01-01 00:00:00
abstract:INTRODUCTION:Early promising results of renal nerve denervation awakened interest in developing medical device alternatives for patients with resistant hypertension. The subsequent sham-controlled renal nerve denervation randomized trials were disappointing leading researchers and innovators to explore alternative devi...
journal_title:Expert review of medical devices
pub_type: 杂志文章,评审
doi:10.1080/17434440.2020.1779054
更新日期:2020-07-01 00:00:00
abstract:INTRODUCTION:Conventional surgical drills are rigid straight instruments used to make holes in bones. They lack the ability to follow a curved pathway, making them impractical for several surgical procedures. For this reason, there is a continuous need for improved devices for surgical drilling of curved holes. AREAS ...
journal_title:Expert review of medical devices
pub_type: 杂志文章,评审
doi:10.1080/17434440.2019.1596794
更新日期:2019-04-01 00:00:00
abstract:INTRODUCTION:The slow adoption of innovation into healthcare calls into question the manner of evidence generation for medical technology. This paper identifies potential reasons for this including a lack of attention to human factors, poor evaluation of economic benefits, lack of understanding of the existing healthca...
journal_title:Expert review of medical devices
pub_type: 杂志文章
doi:10.1080/17434440.2018.1418661
更新日期:2018-01-01 00:00:00
abstract:INTRODUCTION:Spinal cord stimulation has emerged as a state-of-the-art evidence-based treatment for chronic neuropathic pain and mixed nociceptive-neuropathic pain. In recent years, several newer devices and treatment algorithms have provided unique and effective ways of treating chronic pain by spinal cord stimulation...
journal_title:Expert review of medical devices
pub_type: 杂志文章,评审
doi:10.1080/17434440.2019.1567325
更新日期:2019-02-01 00:00:00
abstract:INTRODUCTION:Transcatheter devices have contributed significantly to the advances achieved in treating many cardiovascular conditions over the last few decades. Sophisticated and detailed preclinical testing is not only a regulatory requirement to support an investigational device exemption (IDE) application, but more ...
journal_title:Expert review of medical devices
pub_type: 杂志文章
doi:10.1080/17434440.2017.1282313
更新日期:2017-02-01 00:00:00
abstract::Cellular magnetic resonance imaging (CMRI) allows for the tracking of the temporal and spatial migration of cells labeled with MR contrast agents within organs and tissues. This rapidly growing area of experimental research has the potential of translating from bench to bedside and may be used in conjunction with cell...
journal_title:Expert review of medical devices
pub_type: 杂志文章,评审
doi:10.1586/17434440.3.4.427
更新日期:2006-07-01 00:00:00
abstract:INTRODUCTION:The Ovation stent-graft uncouples the steps of fixation and sealing via a pair of polymer-filled inflatable rings. Apart from the well-documented early results, newer data emerged for mid-term results of Ovation and are presented in this review. AREAS COVERED:Aim of this article was to report all current ...
journal_title:Expert review of medical devices
pub_type: 杂志文章,评审
doi:10.1080/17434440.2019.1555467
更新日期:2019-01-01 00:00:00
abstract::There has been considerable development and implementation of new contraceptive methods over the last 15 years. However, sterilization has remained the most widely used method around the world. Ideally, the procedure should be safe, have a high efficacy, be readily accessible, and be personally and culturally acceptab...
journal_title:Expert review of medical devices
pub_type: 杂志文章,评审
doi:10.1586/17434440.5.4.525
更新日期:2008-07-01 00:00:00