Does the novel delivery system for the STENTYS self-apposing coronary stent increase the risk of stent edge dissections? Optical coherence tomography post stent findings.

Abstract:

BACKGROUND:With optical coherence tomography (OCT), details of arterial injuries during percutaneous coronary intervention can be assessed accurately. There might be an increased risk of stent edge dissections with the novel delivery system for the STENTYS stent. We evaluated the prevalence of stent edge dissections using the novel Xposition delivery device as compared with the conventional delivery device. METHODS:A total of 38 patients who were treated with the self-apposing STENTYS stent and with OCT assessment at our center were retrospectively analysed. Twenty patients were treated using the Xposition- and 18 using the conventional delivery device. OCT was performed according to study protocol. Frames with poor quality were excluded. RESULTS:A total of 12(18%) dissections were detected, 7(20%) in the Xposition delivery device group, and 5(15%) in the conventional group (p = 1). Using the Xposition delivery device 4(33%) dissections were found proximally, using the conventional delivery device 3(25%) (p = ns). Mean longitudinal dissection length was 2.07 ± 1.80mm, 8(67%) appeared as flaps, 4(33%) as cavities. Morphometric parameters were comparable in both groups. CONCLUSIONS:Detailed OCT assessment of stent edge dissections was possible, which revealed no large differences using the Xposition delivery device as compared with conventional delivery device, however large studies are warranted.

journal_name

Expert Rev Med Devices

authors

Lu H,Kalkman DN,Grundeken MJ,Tijssen JGP,Wykrzykowska JJ,de Winter RJ,Koch KT

doi

10.1080/17434440.2018.1421942

subject

Has Abstract

pub_date

2018-02-01 00:00:00

pages

157-165

issue

2

eissn

1743-4440

issn

1745-2422

journal_volume

15

pub_type

杂志文章
  • Plugs for left atrial appendage occlusion: an overview of available devices.

    abstract:INTRODUCTION:Approximately one-third of all ischemic strokes and the ensuing health and economic burden can be attributed to the presence of atrial fibrillation (AF). The global prevalence of AF continues to rise, thus making it by far the most common diagnosed cardiac arrhythmia. Percutaneous left atrial appendage (LA...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2020.1837621

    authors: Obeid S,Nietlispach F,Meier B

    更新日期:2020-11-01 00:00:00

  • Drug-eluting stents: from evidence to policy.

    abstract::Drug-eluting stents are a major breakthrough in cardiology, with the Cypher (Cordis Corporation) and Taxus (Boston Scientific) stents preventing 60-70% of repeat coronary revascularizations, compared with bare metal stents. Both evidence- and risk-based application of drug-eluting stents is expected to create relevant...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.1.1.49

    authors: Marchetti M

    更新日期:2004-09-01 00:00:00

  • Robotic navigation during spine surgery.

    abstract::Introduction: Potential complications associated with screw malposition may result in neurological deficits or vascular injuries. Spine surgery has significantly developed under the assistance of technological progress. The advantages of applying robotic technology in spine surgery include the possibility of improving...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2020.1699405

    authors: Zhang Q,Han XG,Xu YF,Fan MX,Zhao JW,Liu YJ,He D,Tian W

    更新日期:2020-01-01 00:00:00

  • Using medical imaging for the detection of adverse events ("incidents") during the utilization of left ventricular assist devices in adult patients with advanced heart failure.

    abstract::Ventricular assist devices (VAD) are used for mechanical support of the terminally failing heart. Failure of these life supporting systems can be fatal. Early and reliable detection of any upcoming problems is mandatory and is crucial for the outcome. Medical imaging methods are described within this review, which are...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2016.1166051

    authors: Kaufmann F,Krabatsch T

    更新日期:2016-05-01 00:00:00

  • Consumer sleep tracking devices: a review of mechanisms, validity and utility.

    abstract::Consumer sleep tracking devices such as fitness trackers and smartphone apps have become increasingly popular. These devices claim to measure the sleep duration of their users and in some cases purport to measure sleep quality and awaken users from light sleep, potentially improving overall sleep. Most of these device...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2016.1171708

    authors: Kolla BP,Mansukhani S,Mansukhani MP

    更新日期:2016-05-01 00:00:00

  • Modeling of the medical device development process.

    abstract::Models are abstract representations of reality that are built, analyzed and manipulated to augment the understanding of that reality. They can either be mental or codified but, in both cases, they contribute to good decision-making by ensuring that the right people use the right information at the right time. In order...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/erd.12.36

    authors: Santos IC,Gazelle GS,Rocha LA,Tavares JM

    更新日期:2012-09-01 00:00:00

  • Development of inexpensive blood imaging systems: where are we now?

    abstract::Clinical applications in the developing world, such as malaria and anemia diagnosis, demand a change in the medical paradigm of expensive care given in central locations by highly trained professionals. There has been a recent explosion in optical technologies entering the consumer market through the widespread adopti...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2015.1075388

    authors: Chu K,Smith ZJ,Wachsmann-Hogiu S

    更新日期:2015-01-01 00:00:00

  • Stent placement for esophageal strictures: an update.

    abstract::The use of stents for esophageal strictures has evolved rapidly over the past 10 years, from rigid plastic tubes to flexible self-expanding metal (SEMS), plastic (SEPS) and biodegradable stents. For the palliative treatment of malignant dysphagia both SEMS and SEPS effectively provide a rapid relief of dysphagia. SEMS...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/erd.11.44

    authors: Hirdes MM,Vleggaar FP,Siersema PD

    更新日期:2011-11-01 00:00:00

  • Could a new sensory pen assist in the early diagnosis of Parkinson's?

    abstract::Neurodegeneration in Parkinson's disease (PD) affects both the fine motor control of the fingers and gross movement of the upper limb. Handwriting examinations are commonly performed in the analysis of tremor in PD and there is validity in subjective assessment in the clinic. However, there is clinical need for a more...

    journal_title:Expert review of medical devices

    pub_type: 社论,评审

    doi:10.1586/17434440.2014.900437

    authors: Walker RW,Zietsma R,Gray WK

    更新日期:2014-05-01 00:00:00

  • Wearable inertial sensors for human movement analysis.

    abstract:INTRODUCTION:The present review aims to provide an overview of the most common uses of wearable inertial sensors in the field of clinical human movement analysis. AREAS COVERED:Six main areas of application are analysed: gait analysis, stabilometry, instrumented clinical tests, upper body mobility assessment, daily-li...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2016.1198694

    authors: Iosa M,Picerno P,Paolucci S,Morone G

    更新日期:2016-07-01 00:00:00

  • Recent advances in imaging technologies for assessment of retinal diseases.

    abstract:INTRODUCTION:Retinal imaging is a key investigation in ophthalmology. New devices continue to be created to keep up with the demand for better imaging modalities in this field. This review looks to highlight current trends and the future of retinal imaging. AREAS COVERED:This review looks at the advances in topographi...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2020.1816167

    authors: Soomro T,Shah N,Niestrata-Ortiz M,Yap T,Normando EM,Cordeiro MF

    更新日期:2020-10-01 00:00:00

  • Polyhydroxyalkanoate (PHA): applications in drug delivery and tissue engineering.

    abstract:INTRODUCTION:The applications of naturally obtained polymers are tremendously increased due to them being biocompatible, biodegradable, environmentally friendly and renewable in nature. Among them, polyhydroxyalkanoates are widely studied and they can be utilized in many areas of human life research such as drug delive...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2019.1615439

    authors: Elmowafy E,Abdal-Hay A,Skouras A,Tiboni M,Casettari L,Guarino V

    更新日期:2019-06-01 00:00:00

  • Differential effects of public and private funding in the medical device industry.

    abstract:INTRODUCTION:Funding for scientific advancement comes from two dominant sources: public funds used to generate knowledge, and private sector funds in the pursuit of commercial products. It is unclear how to compare the outputs of these two financial mechanisms because both sectors are motivated by common goods but are ...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章

    doi:10.1080/17434440.2018.1419866

    authors: Kang HD,Edelman ER,Ku DN

    更新日期:2018-02-01 00:00:00

  • Device profile of the MobiusHD EVBA system for the treatment of resistant hypertension: overview of its mechanism of action, safety and efficacy.

    abstract:INTRODUCTION:Early promising results of renal nerve denervation awakened interest in developing medical device alternatives for patients with resistant hypertension. The subsequent sham-controlled renal nerve denervation randomized trials were disappointing leading researchers and innovators to explore alternative devi...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2020.1779054

    authors: Bates MC,Stone GW,Chen CY,Spiering W

    更新日期:2020-07-01 00:00:00

  • Diagnosis of small-bowel diseases in the era of capsule endoscopy.

    abstract::Capsule endoscopy is a major breakthrough in gastrointestinal endoscopy and is a first-line tool to detect abnormalities of the small bowel, in up to 50% of patients, intestinal disorders are not associated with any physical findings or positive tests. Indications, yield and impact on patient management of this method...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2.5.587

    authors: Pennazio M

    更新日期:2005-09-01 00:00:00

  • Robot-assisted total hip arthroplasty.

    abstract::Precise and accurate biomechanical reconstruction during total hip arthroplasty (THA) is essential for durable long-term survivorship. Accurate fit of cementless hip implants is also crucial to reduce micromotion between the bone-implant interfaces to allow for stable osseointegration. Robotic technology aims to minim...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2016.1124018

    authors: Banerjee S,Cherian JJ,Elmallah RK,Pierce TP,Jauregui JJ,Mont MA

    更新日期:2016-01-01 00:00:00

  • Evaluation of Pipeline Flex delivery system for the treatment of unruptured aneurysms.

    abstract:INTRODUCTION:Refinements in endovascular technology have revolutionized the treatment of intracranial aneurysms (IAs) with the development of flow-diversion technology. The first generation of the Pipelin Embolization Device (PED) has demonstrated its safety and efficacy. However, the deployment technique was a difficu...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章

    doi:10.1080/17434440.2016.1231573

    authors: Aguilar-Salinas P,Brasiliense LB,Gonsales D,Mitchell B,Lima A,Sauvageau E,Hanel R

    更新日期:2016-10-01 00:00:00

  • A review of thermal methods and technologies for diabetic foot assessment.

    abstract::Temperature analysis has been considered as a complementary method in medical evaluation and diagnosis. Several studies demonstrated that monitoring the temperature variations of the feet of diabetic patients can be helpful in the early identification of diabetic foot manifestations, and also in changing behaviors, wh...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2015.1032251

    authors: Sousa P,Felizardo V,Oliveira D,Couto R,Garcia NM

    更新日期:2015-07-01 00:00:00

  • Current interventional coronary applications of excimer laser.

    abstract::Excimer laser utilization as an adjunctive device for percutaneous coronary intervention has increased in the last few years. Many technical advancements have led to better results in terms of efficacy and safety with a low complication rate. In particular, excimer laser for thrombus-containing lesions is able to achi...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2013.811846

    authors: Fracassi F,Roberto M,Niccoli G

    更新日期:2013-07-01 00:00:00

  • Current and future developments in artificial muscles using electroactive polymers.

    abstract::For decades, electroactive polymers received relatively little attention due to their limited actuation capability. However, in the last 15 years, a series of electroactive polymer materials have emerged that produce a significant shape or size change in response to electrical stimulation. These materials have the clo...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2.6.731

    authors: Bar-Cohen Y

    更新日期:2005-11-01 00:00:00

  • A clinical update on the mid-term clinical performance of the Ovation endograft.

    abstract:INTRODUCTION:The Ovation stent-graft uncouples the steps of fixation and sealing via a pair of polymer-filled inflatable rings. Apart from the well-documented early results, newer data emerged for mid-term results of Ovation and are presented in this review. AREAS COVERED:Aim of this article was to report all current ...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2019.1555467

    authors: Koutsoumpelis A,Georgakarakos E,Tasopoulou KM,Kontopodis N,Argyriou C,Georgiadis GS

    更新日期:2019-01-01 00:00:00

  • Abdominal wall reconstruction using biological tissue grafts: present status and future opportunities.

    abstract::Surgeons often encounter the challenge of treating acquired abdominal wall defects following abdominal surgery. The current standard of practice is to repair most defects using permanent synthetic mesh material. Mesh augments the strength of the weakened abdominal wall fascia and enables the hernia repair to be perfor...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.3.5.657

    authors: Bellows CF,Alder A,Helton WS

    更新日期:2006-09-01 00:00:00

  • Mechanical circulatory support devices: methods to optimize hemodynamics during use.

    abstract:INTRODUCTION:Mechanical circulatory support (MCS) is an increasingly utilized mode of therapy in the management of advanced heart failure, both as bridge to heart transplantation and destination therapy. As MCS becomes more prevalent, it is ever more important to understand the complex hemodynamics of these devices, as...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2017.1324292

    authors: Chung BB,Sayer G,Uriel N

    更新日期:2017-05-01 00:00:00

  • Electrothermal bipolar vessel sealing system (LigaSure) for hemostasis during thyroid surgery: a comprehensive review.

    abstract::Conventional hemostatic technologies utilized in thyroid surgery include clamp-and-tie, clips and monopolar and bipolar diathermy. Over the last decade, there has been a major shift towards utilizing newer hemostatic technologies, most notably the electrothermal bipolar vessel sealing systems (EBVS) and the Harmonic S...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/erd.13.6

    authors: Butskiy O,Wiseman SM

    更新日期:2013-05-01 00:00:00

  • Safe incorporation of new technologies in thyroid surgery.

    abstract::The history of thyroid surgery starts with Billroth, Kocher and Halsted, who developed the technique for thyroidectomy between the years of 1873 and 1910. In general the essential objectives for thyroidectomy are: sparing the parathyroid glands, avoidance of injury to the laryngeal nerves, an accurate hemostasis and a...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.5.6.747

    authors: Dionigi G,Bacuzzi A,Bertocchi V,Carrafiello G,Boni L,Rovera F,Dionigi R

    更新日期:2008-11-01 00:00:00

  • Innovative developments of the heart valves designed for use in ventricular assist devices.

    abstract::Prosthetic heart valves are routinely used for replacing diseased natural heart valves. Even today, after five decades of prosthetic heart valve development, in the authors opinion the main problem associated with these valves is the risk of thromboembolic complications caused by unnatural hemodynamics. Further growin...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2.1.61

    authors: Goubergrits L,Affeld K,Kertzscher U

    更新日期:2005-01-01 00:00:00

  • Designing medical technology for resilience: integrating health economics and human factors approaches.

    abstract:INTRODUCTION:The slow adoption of innovation into healthcare calls into question the manner of evidence generation for medical technology. This paper identifies potential reasons for this including a lack of attention to human factors, poor evaluation of economic benefits, lack of understanding of the existing healthca...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章

    doi:10.1080/17434440.2018.1418661

    authors: Borsci S,Uchegbu I,Buckle P,Ni Z,Walne S,Hanna GB

    更新日期:2018-01-01 00:00:00

  • Ventricular assist devices for the failing univentricular circulation.

    abstract:INTRODUCTION:Improved survival following single ventricle palliation has led to a large population of patients with a univentricular circulation, many of whom develop heart failure. Increasing experience with ventricular assist devices (VAD) in children has paved the way for VAD support in those with failing univentric...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章

    doi:10.1080/17434440.2017.1332523

    authors: Buratto E,Shi WY,Ye XT,Konstantinov IE

    更新日期:2017-06-01 00:00:00

  • Non-invasive assessment of gestational hemodynamics: benefits and limitations of impedance cardiography versus other techniques.

    abstract::To obtain data for maternal stroke volume and cardiac output during pregnancy, it is preferable to use a non-invasive, accurate and reproducible method. In this aspect, impedance cardiography is an excellent technique which is also highly accessible and easy to perform. This paper is a comprehensive review on the publ...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2013.853466

    authors: Staelens A,Tomsin K,Grieten L,Oben J,Mesens T,Spaanderman M,Jacquemyn Y,Gyselaers W

    更新日期:2013-11-01 00:00:00

  • Wearable sensors to improve detection of patient deterioration.

    abstract:INTRODUCTION:Monitoring a patient's vital signs forms a basic component of care, enabling the identification of deteriorating patients and increasing the likelihood of improving patient outcomes. Several paper-based track and trigger warning scores have been developed to allow clinical evaluation of a patient and guida...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2019.1563480

    authors: Joshi M,Ashrafian H,Aufegger L,Khan S,Arora S,Cooke G,Darzi A

    更新日期:2019-02-01 00:00:00