Abstract:

:Surgeons often encounter the challenge of treating acquired abdominal wall defects following abdominal surgery. The current standard of practice is to repair most defects using permanent synthetic mesh material. Mesh augments the strength of the weakened abdominal wall fascia and enables the hernia repair to be performed in a tension-free manner. However, there is a risk of acute and/or chronic infection, fistula formation and chronic abdominal wall pain with the use of permanent mesh materials, which can lead to more complex operations. As a means to avoid such problems, surgeons are turning increasingly to the use of xenogenic and allogenic materials for the repair of abdominal wall defects. Their rapid evolution and introduction into the clinical operating room is leading to a new era in abdominal wall reconstruction. There are promising, albeit limited, clinical data with short-term follow-up for only a few of the many biological tissue grafts that are being promoted currently for the repair of abdominal hernias. Additional clinical studies are required to better understand the long-term efficacy and limitations of these materials.

journal_name

Expert Rev Med Devices

authors

Bellows CF,Alder A,Helton WS

doi

10.1586/17434440.3.5.657

subject

Has Abstract

pub_date

2006-09-01 00:00:00

pages

657-75

issue

5

eissn

1743-4440

issn

1745-2422

journal_volume

3

pub_type

杂志文章,评审
  • Modeling of the medical device development process.

    abstract::Models are abstract representations of reality that are built, analyzed and manipulated to augment the understanding of that reality. They can either be mental or codified but, in both cases, they contribute to good decision-making by ensuring that the right people use the right information at the right time. In order...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/erd.12.36

    authors: Santos IC,Gazelle GS,Rocha LA,Tavares JM

    更新日期:2012-09-01 00:00:00

  • Clinical role of fluorescence imaging in colorectal surgery - a review.

    abstract:INTRODUCTION:Anastomotic leak (AL) after colorectal surgery is a devastating complication; decreased blood perfusion is an important risk factor. Surgeons rely on subjective measures to assess bowel perfusion. Fluorescence imaging (FI) with indocyanine green (ICG) provides a real-time objective assessment of intestinal...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,meta分析,评审

    doi:10.1080/17434440.2017.1265444

    authors: Mizrahi I,Wexner SD

    更新日期:2017-01-01 00:00:00

  • Performance of a new device for the clinical determination of light discomfort.

    abstract:PURPOSE:To assess the performance of a new device for the clinical determination of light discomfort on a large sample of healthy human subjects. METHODS:A total of 489 subjects ranging from 20 to 70 years old (241 men, 248 women) were evaluated with the LUMIZ™ 100 to determine light discomfort. Repeatability was asse...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章

    doi:10.1080/17434440.2020.1837623

    authors: Montés-Micó R,Cerviño A,Martínez-Albert N,García-Marqués JV,Marie S

    更新日期:2020-11-01 00:00:00

  • The role of active middle-ear implants in the rehabilitation of hearing loss.

    abstract::The surgical implantation of auditory devices to improve or restore the sensation of hearing in affected individuals is a rapidly growing area of modern ear, nose and throat, and audiological practice. Following the enormous success of cochlear implantation and set to take an increasing role in the rehabilitation of d...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/erd.11.18

    authors: Green K

    更新日期:2011-07-01 00:00:00

  • Resurrection of hip resurfacing: what is the evidence?

    abstract::Total hip resurfacing has long been conceptually attractive to both surgeons and patients. However, historically it has been plagued by limited durability and marked acetabular bone loss. The recent development of wear-resistant bearings, such as metal-on-metal, has led to renewed interest in hip resurfacing in the or...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.3.6.755

    authors: Moroni A,Cadossi M,Bellenghi C,Romagnoli M,Bevoni R,Giannini S

    更新日期:2006-11-01 00:00:00

  • A robot for transnasal surgery featuring needle-sized tentacle-like arms.

    abstract::This paper discusses a new class of robots known as concentric tube robots and their application to transnasal skull base surgery. The endonasal approach has clear benefits for patients, but the surgery presents challenges that strongly motivate the use of robotic tools. In this paper, the concentric tube robot concep...

    journal_title:Expert review of medical devices

    pub_type: 社论

    doi:10.1586/17434440.2013.854702

    authors: Gilbert H,Hendrick R,Remirez A,Webster R 3rd

    更新日期:2014-01-01 00:00:00

  • Mechanical circulatory support devices: methods to optimize hemodynamics during use.

    abstract:INTRODUCTION:Mechanical circulatory support (MCS) is an increasingly utilized mode of therapy in the management of advanced heart failure, both as bridge to heart transplantation and destination therapy. As MCS becomes more prevalent, it is ever more important to understand the complex hemodynamics of these devices, as...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2017.1324292

    authors: Chung BB,Sayer G,Uriel N

    更新日期:2017-05-01 00:00:00

  • Insertable cardiac monitors: current indications and devices.

    abstract:INTRODUCTION:Recurrent unexplained syncope is a well-established indication for an insertable cardiac monitor (ICM). Recently, the indications for an ICM have been expanded. AREAS COVERED:This review article discusses the current indications for ICMs and gives an overview of the latest generation of commercially avail...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2018.1557046

    authors: Sakhi R,Theuns DAMJ,Szili-Torok T,Yap SC

    更新日期:2019-01-01 00:00:00

  • Miniaturization of left ventricular assist devices: the ongoing trend.

    abstract::The shortage of appropriate donor hearts and the expanding pool of patients waiting for a heart transplantation have led to growing interest in alternative strategies, particularly in mechanical circulatory support. With expanding clinical experience and continued technical advances, continuous-flow pumps are evolving...

    journal_title:Expert review of medical devices

    pub_type: 历史文章,杂志文章,评审

    doi:10.1586/erd.11.62

    authors: Garbade J,Bittner HB,Lehmann S,Mohr FW,Barten MJ

    更新日期:2012-01-01 00:00:00

  • Creating a wearable artificial kidney: where are we now?

    abstract::A wearable and, ultimately, an implantable artificial kidney is a long-held aim in the treatment of patients with end-stage renal disease, provided that it would combine continuous blood purification, preventing the fluctuations in the internal environment associated with hemodialysis, while maintaining a high efficie...

    journal_title:Expert review of medical devices

    pub_type: 社论

    doi:10.1586/17434440.2015.1053466

    authors: Kooman JP,Joles JA,Gerritsen KG

    更新日期:2015-07-01 00:00:00

  • Cardima Surgical Ablation System: a novel tool for cardiac ablation in the treatment of atrial fibrillation.

    abstract::Atrial fibrillation is a pervasive and difficult heart rhythm problem for more than 3 million Americans. Patients are plagued by myriad symptoms and are exposed to the risk of stroke. Attempts to restore normal rhythm with drug therapy have been largely unsuccessful and the complications associated with long-term anti...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/erd.09.9

    authors: Saltman AE

    更新日期:2009-05-01 00:00:00

  • Autofluorescence imaging videobronchoscopy in the detection of lung cancer: from research tool to everyday procedure.

    abstract::Autofluorescence imaging videobronchoscopy (AFI) is one of the new systems of autofluorescence bronchoscopy designed for thorough examination of bronchial mucosa. The integration of autofluorescence and videobronchoscopy provides clear images of normal and pathologically altered bronchial mucosa. Major indications for...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章

    doi:10.1586/erd.10.92

    authors: Zaric B,Perin B,Becker HD,Herth FF,Eberhardt R,Djuric M,Djuric D,Matijasevic J,Kopitovic I,Stanic J

    更新日期:2011-03-01 00:00:00

  • Innovative developments of the heart valves designed for use in ventricular assist devices.

    abstract::Prosthetic heart valves are routinely used for replacing diseased natural heart valves. Even today, after five decades of prosthetic heart valve development, in the authors opinion the main problem associated with these valves is the risk of thromboembolic complications caused by unnatural hemodynamics. Further growin...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2.1.61

    authors: Goubergrits L,Affeld K,Kertzscher U

    更新日期:2005-01-01 00:00:00

  • A review of thermal methods and technologies for diabetic foot assessment.

    abstract::Temperature analysis has been considered as a complementary method in medical evaluation and diagnosis. Several studies demonstrated that monitoring the temperature variations of the feet of diabetic patients can be helpful in the early identification of diabetic foot manifestations, and also in changing behaviors, wh...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2015.1032251

    authors: Sousa P,Felizardo V,Oliveira D,Couto R,Garcia NM

    更新日期:2015-07-01 00:00:00

  • Intraoperative storage of saphenous vein grafts in coronary artery bypass grafting.

    abstract::Background: Saline is not biocompatible with saphenous vein grafts and does not protect against ischemia reperfusion injury. We compared normal heparinized saline with DuraGraft, a new graft-storage solution, in in-vitro and ex-vivo assays to evaluate the effects on cells and vascular graft tissue.Methods: Human saphe...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章

    doi:10.1080/17434440.2019.1682996

    authors: Pachuk CJ,Rushton-Smith SK,Emmert MY

    更新日期:2019-11-01 00:00:00

  • Wearable inertial sensors for human movement analysis.

    abstract:INTRODUCTION:The present review aims to provide an overview of the most common uses of wearable inertial sensors in the field of clinical human movement analysis. AREAS COVERED:Six main areas of application are analysed: gait analysis, stabilometry, instrumented clinical tests, upper body mobility assessment, daily-li...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2016.1198694

    authors: Iosa M,Picerno P,Paolucci S,Morone G

    更新日期:2016-07-01 00:00:00

  • Evolution of endovascular stroke therapies and devices.

    abstract::Acute ischemic stroke is caused by occlusion of a cerebral artery, resulting in loss of brain tissue and neurologic deficits. However, a portion of the ischemic brain can be salvaged if blood flow is restored within an appropriate time frame. The past year has seen the publication of five positive randomized controlle...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2016.1143772

    authors: Wallace AN,Kansagra AP,McEachern J,Moran CJ,Cross DT 3rd,Derdeyn CP

    更新日期:2016-01-01 00:00:00

  • Does the novel delivery system for the STENTYS self-apposing coronary stent increase the risk of stent edge dissections? Optical coherence tomography post stent findings.

    abstract:BACKGROUND:With optical coherence tomography (OCT), details of arterial injuries during percutaneous coronary intervention can be assessed accurately. There might be an increased risk of stent edge dissections with the novel delivery system for the STENTYS stent. We evaluated the prevalence of stent edge dissections us...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章

    doi:10.1080/17434440.2018.1421942

    authors: Lu H,Kalkman DN,Grundeken MJ,Tijssen JGP,Wykrzykowska JJ,de Winter RJ,Koch KT

    更新日期:2018-02-01 00:00:00

  • Female sterilization.

    abstract::There has been considerable development and implementation of new contraceptive methods over the last 15 years. However, sterilization has remained the most widely used method around the world. Ideally, the procedure should be safe, have a high efficacy, be readily accessible, and be personally and culturally acceptab...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.5.4.525

    authors: Chapman L,Magos A

    更新日期:2008-07-01 00:00:00

  • Currently available metacarpophalangeal prostheses: their designs and prospective considerations.

    abstract::Although implanted for over 40 years, finger prostheses have failed to match the success achieved by artificial hip and knee prostheses, despite a myriad of designs having been proposed and implanted. This article looks at the currently available designs of metacarpophalangeal prosthesis, both single-piece and multico...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.1.2.193

    authors: Joyce TJ

    更新日期:2004-11-01 00:00:00

  • Shortening hospital stay for thyroid surgery.

    abstract::The number of outpatient surgical procedures performed in hospitals, increases daily. In some countries, such as Italy, outpatient operations outnumber inpatient operations. The incidence of thyroid disorders and, in particular, the cancer forms, has been increasing sharply for many years in several countries. Even if...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.5.1.85

    authors: Dionigi G,Bacuzzi A,Rovera F,Boni L,Piantanida E,Tanda ML,Castano P,Annoni M,Bartalena L,Dionigi R

    更新日期:2008-01-01 00:00:00

  • The Visible Heart® project and methodologies: novel use for studying cardiac monophasic action potentials and evaluating their underlying mechanisms.

    abstract:INTRODUCTION:This review describes the utilization of Visible Heart® methodologies for electrophysiologic studies, specifically in the investigation of monophasic action potential (MAP) recordings, with the aim to facilitate new catheter/device design and development that may lead to earlier diagnosis, treatment, and u...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2018.1493922

    authors: Schmidt MM,Iaizzo PA

    更新日期:2018-07-01 00:00:00

  • Device profile of the MobiusHD EVBA system for the treatment of resistant hypertension: overview of its mechanism of action, safety and efficacy.

    abstract:INTRODUCTION:Early promising results of renal nerve denervation awakened interest in developing medical device alternatives for patients with resistant hypertension. The subsequent sham-controlled renal nerve denervation randomized trials were disappointing leading researchers and innovators to explore alternative devi...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2020.1779054

    authors: Bates MC,Stone GW,Chen CY,Spiering W

    更新日期:2020-07-01 00:00:00

  • Top 100 cited noninvasive neuromodulation clinical trials.

    abstract:INTRODUCTION:Introduction: Transcranial direct current stimulation (tDCS) and transcranial magnetic stimulation (TMS) are noninvasive neuromodulation techniques used as therapeutic and research tools for several neuropsychiatric conditions. Given the exponential scientific growth of this field, we aimed to systematical...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2019.1615440

    authors: Lucena MFG,Teixeira PEP,Bonin Pinto C,Fregni F

    更新日期:2019-06-01 00:00:00

  • Sleep assessment devices: types, market analysis, and a critical view on accuracy and validation.

    abstract::Introduction: Sleep assessment devices are essential for the detection, diagnosis, and monitoring of sleep disorders. This paper provides a state-of-the-art review and comparison of sleep assessment devices and a market analysis.Areas covered: Hardware devices are classified into contact and contactless devices. For e...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2019.1693890

    authors: Ibáñez V,Silva J,Navarro E,Cauli O

    更新日期:2019-12-01 00:00:00

  • New developments in ureteral stent design, materials and coatings.

    abstract::Ureteral stents are used in a variety of urological diseases and procedures. The majority of patients with indwelling ureteral stents experience bothersome symptoms and are at increased risk for urinary tract infection. Stent encrustation and the associated complications can also result in significant patient morbidit...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.3.3.395

    authors: Chew BH,Duvdevani M,Denstedt JD

    更新日期:2006-05-01 00:00:00

  • The EluNIRTM Ridaforolimus Eluting Coronary Stent System.

    abstract:INTRODUCTION:First-generation drug-eluting stents (DES) were developed and indeed proved their superiority compared to bare-metal stent in minimizing neo-intimal hyperplasia and in-stent restenosis (ISR), overall, reducing target vessel revascularization (TVR). Newer-generation DES are characterized by thinner struts, ...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章

    doi:10.1080/17434440.2018.1549986

    authors: Savvoulidis P,Perlman G,Bagur R

    更新日期:2019-01-01 00:00:00

  • Prostheses for reverse total shoulder arthroplasty.

    abstract:INTRODUCTION:Historically, patients with rotator cuff arthropathy had limited reconstructive options. The early generations of reverse total shoulder arthroplasty (rTSA) designs had increased failure rates due to loosening of glenoid baseplates secondary to excessive torques. In 1985, Paul Grammont introduced a prosthe...

    journal_title:Expert review of medical devices

    pub_type: 历史文章,杂志文章,评审

    doi:10.1080/17434440.2019.1568237

    authors: Kazley JM,Cole KP,Desai KJ,Zonshayn S,Morse AS,Banerjee S

    更新日期:2019-02-01 00:00:00

  • The challenges surrounding preclinical testing in transcatheter device development and the implications on the clinic.

    abstract:INTRODUCTION:Transcatheter devices have contributed significantly to the advances achieved in treating many cardiovascular conditions over the last few decades. Sophisticated and detailed preclinical testing is not only a regulatory requirement to support an investigational device exemption (IDE) application, but more ...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章

    doi:10.1080/17434440.2017.1282313

    authors: Holzer R,Goble J,Hijazi Z

    更新日期:2017-02-01 00:00:00

  • Single-step atrial thrombus exclusion and transesophageal cardioversion in atrial fibrillation.

    abstract::Atrial fibrillation (AF), the most common arrhythmia, has a major impact on both patient morbidity and healthcare economics. Hospital admissions due to AF have risen by two-thirds in the last 20 years. This is due mainly to an aging population and an increasing prevalence of chronic heart disease. Strategies for the m...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.4.4.549

    authors: Mischke K,Schimpf T,Knackstedt C,Hanrath P,Schauerte P