New developments in ureteral stent design, materials and coatings.

Abstract:

:Ureteral stents are used in a variety of urological diseases and procedures. The majority of patients with indwelling ureteral stents experience bothersome symptoms and are at increased risk for urinary tract infection. Stent encrustation and the associated complications can also result in significant patient morbidity. The development of new stent designs using novel biomaterials, stent coatings and drug-eluting technologies are being applied to reduce the disadvantageous features of ureteral stents.

journal_name

Expert Rev Med Devices

authors

Chew BH,Duvdevani M,Denstedt JD

doi

10.1586/17434440.3.3.395

subject

Has Abstract

pub_date

2006-05-01 00:00:00

pages

395-403

issue

3

eissn

1743-4440

issn

1745-2422

journal_volume

3

pub_type

杂志文章,评审
  • Treating bladder-outflow obstruction with thermo-expandable prostate metal stents.

    abstract::Bladder-outflow obstruction is a common age-related clinical entity due to a variety of benign and malignant diseases of the prostate. Surgical treatment is not suitable for high-risk elderly patients who seek minimally invasive management. We present a prostatic thermo-expandable metal stent for treating bladder-outf...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/erd.09.13

    authors: Papatsoris AG,El-Husseiny T,Sawada Y,Takahashi T,Nagaoka A,Maan Z,Moraitis K,Masood J,Junaid I,Buchholz N

    更新日期:2009-07-01 00:00:00

  • A clinical update on the mid-term clinical performance of the Ovation endograft.

    abstract:INTRODUCTION:The Ovation stent-graft uncouples the steps of fixation and sealing via a pair of polymer-filled inflatable rings. Apart from the well-documented early results, newer data emerged for mid-term results of Ovation and are presented in this review. AREAS COVERED:Aim of this article was to report all current ...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2019.1555467

    authors: Koutsoumpelis A,Georgakarakos E,Tasopoulou KM,Kontopodis N,Argyriou C,Georgiadis GS

    更新日期:2019-01-01 00:00:00

  • Comparison of stents used for endovascular treatment of intracranial aneurysms.

    abstract:INTRODUCTION:Stent-assisted coiling (SAC) has widened indications of endovascular treatment of intracranial aneurysms (wide-neck, fusiform aneurysms); moreover, it is associated with more stable anatomical results. Besides the development of other techniques such as flow diverter stents, bifurcation stents, or intrasac...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2018.1538779

    authors: Mine B,Bonnet T,Vazquez-Suarez JC,Iosif C,Lubicz B

    更新日期:2018-11-01 00:00:00

  • Driving restriction in patients with cardiac implantable electronic devices: an overview of worldwide regulations.

    abstract::Introduction: It is common belief that driving with an implantable cardioverter defibrillator (ICD)/pacemaker (PM) might be associated with sudden cardiac incapacitation, road traffic accidents, and chance to harm to self and others. On the other hand, the ability to drive is highly valuable in the modern era, represe...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2020.1742108

    authors: Imberti JF,Vitolo M,Proietti M,Diemberger I,Ziacchi M,Biffi M,Boriani G

    更新日期:2020-04-01 00:00:00

  • Consumer sleep tracking devices: a review of mechanisms, validity and utility.

    abstract::Consumer sleep tracking devices such as fitness trackers and smartphone apps have become increasingly popular. These devices claim to measure the sleep duration of their users and in some cases purport to measure sleep quality and awaken users from light sleep, potentially improving overall sleep. Most of these device...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2016.1171708

    authors: Kolla BP,Mansukhani S,Mansukhani MP

    更新日期:2016-05-01 00:00:00

  • Mechanical adjuncts for cardiocerebral resuscitation.

    abstract::Introduction: Cardiac arrest remains a worldwide health problem with very poor outcome. In the absence of bystander resuscitation, survival rates decrease by 10% per minute of arrest and global ischemia. Even the best manual chest compressions, however, can only produce a fraction of normal cardiac output and blood fl...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2019.1649135

    authors: Riess ML,Balzer C

    更新日期:2019-09-01 00:00:00

  • Transcatheter aortic valve implantation: long-term clinical outcome and valve durability.

    abstract::Transcatheter aortic valve implantation (TAVI) is a widely used intervention in patients who are at high risk or contraindicated for cardiac surgery. The procedure is technically feasible in most patients and has very good mid-term clinical outcomes. In this special report, we evaluated the long-term outcome after TAV...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章

    doi:10.1586/17434440.2015.1063994

    authors: Sulzenko J,Tousek P,Kocka V,Widimsky P

    更新日期:2015-01-01 00:00:00

  • Improving retrieval rates for retrievable inferior vena cava filters.

    abstract::The introduction of retrievable inferior vena cava (IVC) filters was an important step in the evolution of deep vein thrombosis/pulmonary embolism management. Their removability makes them preferred to permanent filters in many cases. IVC filter retrieval often occurs at a suboptimal rate, leading to complications ass...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/erd.12.65

    authors: Dixon A,Stavropoulos SW

    更新日期:2013-01-01 00:00:00

  • Cutting balloons, covered stents and paclitaxel-coated balloons for the treatment of dysfunctional dialysis access.

    abstract:INTRODUCTION:Percutaneous transcatheter balloon angioplasty has evolved to the current mainstay treatment for salvage of dysfunctional dialysis access. Nonetheless, it is frequently associated with recurrent vessel restenosis and the need for multiple repeat treatments in order to maintain hemodynamic patency. Cutting-...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2016.1254548

    authors: Kitrou P,Spiliopoulos S,Karnabatidis D,Katsanos K

    更新日期:2016-12-01 00:00:00

  • Modeling of the medical device development process.

    abstract::Models are abstract representations of reality that are built, analyzed and manipulated to augment the understanding of that reality. They can either be mental or codified but, in both cases, they contribute to good decision-making by ensuring that the right people use the right information at the right time. In order...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/erd.12.36

    authors: Santos IC,Gazelle GS,Rocha LA,Tavares JM

    更新日期:2012-09-01 00:00:00

  • Polyhydroxyalkanoate (PHA): applications in drug delivery and tissue engineering.

    abstract:INTRODUCTION:The applications of naturally obtained polymers are tremendously increased due to them being biocompatible, biodegradable, environmentally friendly and renewable in nature. Among them, polyhydroxyalkanoates are widely studied and they can be utilized in many areas of human life research such as drug delive...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2019.1615439

    authors: Elmowafy E,Abdal-Hay A,Skouras A,Tiboni M,Casettari L,Guarino V

    更新日期:2019-06-01 00:00:00

  • Advances in temporary mechanical support for treatment of cardiogenic shock.

    abstract::Mechanical circulatory support devices are the mainstay of treatment for severe cardiogenic shock refractory to pharmacologic therapy. Their evolution over the past few decades has been remarkable with a common theme of developing reliable, less bulky and more easily percutaneously implantable devices. The goal of thi...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2015.1086265

    authors: Koprivanac M,Kelava M,Soltesz E,Smedira N,Kapadia S,Brzezinski A,Alansari S,Moazami N

    更新日期:2015-01-01 00:00:00

  • Shortening hospital stay for thyroid surgery.

    abstract::The number of outpatient surgical procedures performed in hospitals, increases daily. In some countries, such as Italy, outpatient operations outnumber inpatient operations. The incidence of thyroid disorders and, in particular, the cancer forms, has been increasing sharply for many years in several countries. Even if...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.5.1.85

    authors: Dionigi G,Bacuzzi A,Rovera F,Boni L,Piantanida E,Tanda ML,Castano P,Annoni M,Bartalena L,Dionigi R

    更新日期:2008-01-01 00:00:00

  • Catheter directed interventions for pulmonary embolism: current status and future prospects.

    abstract::Introduction: Catheter directed interventions (CDIs) have evolved over the past decade in an attempt to reduce the complications of systemic thrombolysis, while providing equivalent therapeutic benefits.Areas covered: CDIs include a wide array of catheters that incorporate ultrasound technology, the infusion of thromb...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2020.1714432

    authors: Abou Ali AN,Saadeddin Z,Chaer RA,Avgerinos ED

    更新日期:2020-02-01 00:00:00

  • Cardiac rhythm management devices in a magnetic resonance environment.

    abstract::MRI is the gold standard diagnostic tool for soft tissue imaging for many specialties. An impressive body of research has proven the effectiveness of cardiac rhythm management devices (CRMDs) objectively, in terms of parameters that include patient's quality of life, morbidity, and mortality. However, interaction betw...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2014.882228

    authors: Fanourgiakis J,Kanoupakis E

    更新日期:2014-03-01 00:00:00

  • Use of microdebriders in common rhinologic disorders.

    abstract::Powered instruments have been introduced into otorhinolaryngology practice over the last decade. These instruments were accepted immediately by many institutions, and continuing development has led to the current use of microdebriders in a variety of surgical procedures in otorhinolaryngology. In clinical rhinology, t...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/erd.10.7

    authors: Cingi C,Sayin I,Civelek S

    更新日期:2010-05-01 00:00:00

  • Prostheses for reverse total shoulder arthroplasty.

    abstract:INTRODUCTION:Historically, patients with rotator cuff arthropathy had limited reconstructive options. The early generations of reverse total shoulder arthroplasty (rTSA) designs had increased failure rates due to loosening of glenoid baseplates secondary to excessive torques. In 1985, Paul Grammont introduced a prosthe...

    journal_title:Expert review of medical devices

    pub_type: 历史文章,杂志文章,评审

    doi:10.1080/17434440.2019.1568237

    authors: Kazley JM,Cole KP,Desai KJ,Zonshayn S,Morse AS,Banerjee S

    更新日期:2019-02-01 00:00:00

  • Current interventional coronary applications of excimer laser.

    abstract::Excimer laser utilization as an adjunctive device for percutaneous coronary intervention has increased in the last few years. Many technical advancements have led to better results in terms of efficacy and safety with a low complication rate. In particular, excimer laser for thrombus-containing lesions is able to achi...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2013.811846

    authors: Fracassi F,Roberto M,Niccoli G

    更新日期:2013-07-01 00:00:00

  • Anti-infective therapy with an Er:YAG laser: influence on peri-implant healing.

    abstract::In addition to conventional treatment modalities (mechanical and chemical), the use of lasers has been increasingly proposed for the treatment of periodontal and peri-implant infections (i.e., cleaning and detoxification of implant surfaces). Preliminary results from basic studies have pointed to the high potential of...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2.3.267

    authors: Sculean A,Schwarz F,Becker J

    更新日期:2005-05-01 00:00:00

  • Top 100 cited noninvasive neuromodulation clinical trials.

    abstract:INTRODUCTION:Introduction: Transcranial direct current stimulation (tDCS) and transcranial magnetic stimulation (TMS) are noninvasive neuromodulation techniques used as therapeutic and research tools for several neuropsychiatric conditions. Given the exponential scientific growth of this field, we aimed to systematical...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2019.1615440

    authors: Lucena MFG,Teixeira PEP,Bonin Pinto C,Fregni F

    更新日期:2019-06-01 00:00:00

  • Accuray CyberKnife image-guided radiosurgical system.

    abstract::Radiosurgery is the application of radiation therapy in an extremely precise manner. These techniques apply large bioequivalent doses of radiation to a small area in order to destroy tumor cells, while sparing surrounding normal tissues. Radiosurgery has been available for intracranial abnormalities since the 1950s bu...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2.2.141

    authors: Welch WC,Gerszten PC

    更新日期:2005-03-01 00:00:00

  • Use of Amplatzer occluders for treatment of aorto-pulmonary fistulas - case and review of the literature.

    abstract:INTRODUCTION:the use of amplatzer occluder family in daily clinical practice has already overcome on-label indications, with growing clinical experience and the technological evolution of devices. Areas covered: We present the case of a patient with a very rare complication following proximal aortic surgery treated usi...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2017.1389636

    authors: Toušek P,Kočka V,Petr R,Ulman J,Hlavička J,Kolesár M

    更新日期:2017-11-01 00:00:00

  • Non-invasive assessment of gestational hemodynamics: benefits and limitations of impedance cardiography versus other techniques.

    abstract::To obtain data for maternal stroke volume and cardiac output during pregnancy, it is preferable to use a non-invasive, accurate and reproducible method. In this aspect, impedance cardiography is an excellent technique which is also highly accessible and easy to perform. This paper is a comprehensive review on the publ...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2013.853466

    authors: Staelens A,Tomsin K,Grieten L,Oben J,Mesens T,Spaanderman M,Jacquemyn Y,Gyselaers W

    更新日期:2013-11-01 00:00:00

  • Perioperative monitoring of fluid responsiveness after esophageal surgery using stroke volume variation.

    abstract:OBJECTIVE:To assess the utility of a new arterial pressure-based cardiac output (FloTrac) and central venous oximetry (PreSep) monitoring system in the perioperative management of patients undergoing radical esophagectomy. CASE SERIES:From May 2006, a new analyzing device (Vigileo monitor; Edwards Lifesciences LLC, To...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章

    doi:10.1586/17434440.5.3.311

    authors: Kobayashi M,Ko M,Kimura T,Meguro E,Hayakawa Y,Irinoda T,Takagane A

    更新日期:2008-05-01 00:00:00

  • Plugs for left atrial appendage occlusion: an overview of available devices.

    abstract:INTRODUCTION:Approximately one-third of all ischemic strokes and the ensuing health and economic burden can be attributed to the presence of atrial fibrillation (AF). The global prevalence of AF continues to rise, thus making it by far the most common diagnosed cardiac arrhythmia. Percutaneous left atrial appendage (LA...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2020.1837621

    authors: Obeid S,Nietlispach F,Meier B

    更新日期:2020-11-01 00:00:00

  • Wearable sensors to improve detection of patient deterioration.

    abstract:INTRODUCTION:Monitoring a patient's vital signs forms a basic component of care, enabling the identification of deteriorating patients and increasing the likelihood of improving patient outcomes. Several paper-based track and trigger warning scores have been developed to allow clinical evaluation of a patient and guida...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2019.1563480

    authors: Joshi M,Ashrafian H,Aufegger L,Khan S,Arora S,Cooke G,Darzi A

    更新日期:2019-02-01 00:00:00

  • Ventricular assist devices for the failing univentricular circulation.

    abstract:INTRODUCTION:Improved survival following single ventricle palliation has led to a large population of patients with a univentricular circulation, many of whom develop heart failure. Increasing experience with ventricular assist devices (VAD) in children has paved the way for VAD support in those with failing univentric...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章

    doi:10.1080/17434440.2017.1332523

    authors: Buratto E,Shi WY,Ye XT,Konstantinov IE

    更新日期:2017-06-01 00:00:00

  • A review of thermal methods and technologies for diabetic foot assessment.

    abstract::Temperature analysis has been considered as a complementary method in medical evaluation and diagnosis. Several studies demonstrated that monitoring the temperature variations of the feet of diabetic patients can be helpful in the early identification of diabetic foot manifestations, and also in changing behaviors, wh...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2015.1032251

    authors: Sousa P,Felizardo V,Oliveira D,Couto R,Garcia NM

    更新日期:2015-07-01 00:00:00

  • From drug eluting stents to bioresorbable scaffolds; to new horizons in PCI.

    abstract::Drug eluting stents and particularly the fully bioresorbable drug-eluting scaffolds herald a new era in percutaneous treatment of coronary artery disease. There has been tremendous progress in drug eluting stents with fully biodegradable coating polymers and polymer-free devices with reservoir technology planting the ...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2016.1143356

    authors: Tenekecioglu E,Bourantas C,Abdelghani M,Zeng Y,Silva RC,Tateishi H,Sotomi Y,Onuma Y,Yılmaz M,Serruys PW

    更新日期:2016-01-01 00:00:00

  • Differential effects of public and private funding in the medical device industry.

    abstract:INTRODUCTION:Funding for scientific advancement comes from two dominant sources: public funds used to generate knowledge, and private sector funds in the pursuit of commercial products. It is unclear how to compare the outputs of these two financial mechanisms because both sectors are motivated by common goods but are ...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章

    doi:10.1080/17434440.2018.1419866

    authors: Kang HD,Edelman ER,Ku DN

    更新日期:2018-02-01 00:00:00