Perioperative monitoring of fluid responsiveness after esophageal surgery using stroke volume variation.

Abstract:

OBJECTIVE:To assess the utility of a new arterial pressure-based cardiac output (FloTrac) and central venous oximetry (PreSep) monitoring system in the perioperative management of patients undergoing radical esophagectomy. CASE SERIES:From May 2006, a new analyzing device (Vigileo monitor; Edwards Lifesciences LLC, Tokyo, Japan), which can be used in combination with the FloTrac and PreSep sensors, has been used in nine patients who have undergone radical operations for thoracic esophageal cancer at our hospital. Stroke volume variation (SVV), calculated for each respiratory cycle and displayed on the Vigileo monitor, precisely predicted intravascular hypovolemia. The maximum SVV of patients who needed fluid resuscitation was significantly higher than that of patients who had a stable circulation. The mean value of the maximum SVV in the patient with or without fluid resuscitation was 25 +/- 6.9 and 13 +/- 1.4%, respectively (p < 0.04). In addition, continuous monitoring of central venous oxygen saturation enabled evaluation of oxygen supply to tissues to aid in determining the need for red blood cell transfusion. The Vigileo monitor (with Flo Trac and PreSep sensors) provided reliable information for the perioperative management of high-risk patients after highly invasive general surgery without the need for an invasive central or pulmonary catheter.

journal_name

Expert Rev Med Devices

authors

Kobayashi M,Ko M,Kimura T,Meguro E,Hayakawa Y,Irinoda T,Takagane A

doi

10.1586/17434440.5.3.311

subject

Has Abstract

pub_date

2008-05-01 00:00:00

pages

311-6

issue

3

eissn

1743-4440

issn

1745-2422

journal_volume

5

pub_type

杂志文章
  • Does CircuLite Synergy assist device as partial ventricular support have a place in modern management of advanced heart failure?

    abstract::The discrepancy between the number of patients on the waiting list and available donor hearts has led to the successful development of left ventricular assist devices (LVAD) as a bridge to transplantation. The conventional LVADs are designed to provide full hemodynamic support for the end-stage failing heart. However,...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2015.985208

    authors: Mohite PN,Sabashnikov A,Simon AR,Weymann A,Patil NP,Unsoeld B,Bireta C,Popov AF

    更新日期:2015-01-01 00:00:00

  • Polyhydroxyalkanoate (PHA): applications in drug delivery and tissue engineering.

    abstract:INTRODUCTION:The applications of naturally obtained polymers are tremendously increased due to them being biocompatible, biodegradable, environmentally friendly and renewable in nature. Among them, polyhydroxyalkanoates are widely studied and they can be utilized in many areas of human life research such as drug delive...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2019.1615439

    authors: Elmowafy E,Abdal-Hay A,Skouras A,Tiboni M,Casettari L,Guarino V

    更新日期:2019-06-01 00:00:00

  • Mechanical circulatory support devices: methods to optimize hemodynamics during use.

    abstract:INTRODUCTION:Mechanical circulatory support (MCS) is an increasingly utilized mode of therapy in the management of advanced heart failure, both as bridge to heart transplantation and destination therapy. As MCS becomes more prevalent, it is ever more important to understand the complex hemodynamics of these devices, as...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2017.1324292

    authors: Chung BB,Sayer G,Uriel N

    更新日期:2017-05-01 00:00:00

  • Shields and garb for decreasing radiation exposure in the cath lab.

    abstract:INTRODUCTION:Decreasing radiation exposure of the cardiac catheterization laboratory staff is critical for minimizing radiation-related adverse outcomes and can be accomplished by decreasing patient dose and by shielding. Areas covered: protection from ionizing radiation can be achieved with architectural, equipment-mo...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2018.1510771

    authors: Karatasakis A,Brilakis ES

    更新日期:2018-09-01 00:00:00

  • Theranostic approaches in nuclear medicine: current status and future prospects.

    abstract::Introduction: Theranostics is an emerging field in which diagnosis and specific targeted therapy are combined to achieve a personalized treatment approach to the patient. In nuclear medicine clinical practice, theranostics is often performed utilizing the same molecule labeled with two different radionuclides, one rad...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2020.1741348

    authors: Filippi L,Chiaravalloti A,Schillaci O,Cianni R,Bagni O

    更新日期:2020-04-01 00:00:00

  • Bicomponent electrospun scaffolds to design extracellular matrix tissue analogs.

    abstract::In the last decade, bicomponent fibers have been proposed to fabricate bio-inspired systems for tissue repair, regenerative medicine, medical healthcare and clinical applications. In comparison with monocomponent fibers, key advantage concerns their ability of self-adapting to the physiological conditions through an e...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2016.1126505

    authors: Guarino V,Cirillo V,Ambrosio L

    更新日期:2016-01-01 00:00:00

  • New developments in ureteral stent design, materials and coatings.

    abstract::Ureteral stents are used in a variety of urological diseases and procedures. The majority of patients with indwelling ureteral stents experience bothersome symptoms and are at increased risk for urinary tract infection. Stent encrustation and the associated complications can also result in significant patient morbidit...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.3.3.395

    authors: Chew BH,Duvdevani M,Denstedt JD

    更新日期:2006-05-01 00:00:00

  • Diagnosis of small-bowel diseases in the era of capsule endoscopy.

    abstract::Capsule endoscopy is a major breakthrough in gastrointestinal endoscopy and is a first-line tool to detect abnormalities of the small bowel, in up to 50% of patients, intestinal disorders are not associated with any physical findings or positive tests. Indications, yield and impact on patient management of this method...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2.5.587

    authors: Pennazio M

    更新日期:2005-09-01 00:00:00

  • Neural machine interfaces for controlling multifunctional powered upper-limb prostheses.

    abstract::This article investigates various neural machine interfaces for voluntary control of externally powered upper-limb prostheses. Epidemiology of upper limb amputation, as well as prescription and follow-up studies of externally powered upper-limb prostheses are discussed. The use of electromyographic interfaces and peri...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.4.1.43

    authors: Ohnishi K,Weir RF,Kuiken TA

    更新日期:2007-01-01 00:00:00

  • A robot for transnasal surgery featuring needle-sized tentacle-like arms.

    abstract::This paper discusses a new class of robots known as concentric tube robots and their application to transnasal skull base surgery. The endonasal approach has clear benefits for patients, but the surgery presents challenges that strongly motivate the use of robotic tools. In this paper, the concentric tube robot concep...

    journal_title:Expert review of medical devices

    pub_type: 社论

    doi:10.1586/17434440.2013.854702

    authors: Gilbert H,Hendrick R,Remirez A,Webster R 3rd

    更新日期:2014-01-01 00:00:00

  • Percutaneous laser ablation of cervical metastatic lymph nodes in papillary thyroid carcinoma: clinical efficacy and anatomical considerations.

    abstract::Background: Papillary thyroid carcinoma is the most common type of thyroid cancer; despite its generally indolent course, patients often develop local post-operative recurrences. Re-operation, however, holds a high complication rate, while at the same time, not all patients benefit from radioiodine ablation. This syst...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章

    doi:10.1080/17434440.2021.1864323

    authors: Spartalis E,Karagiannis SP,Plakopitis N,Theodori MA,Athanasiadis DI,Schizas D,Spartalis M,Troupis T

    更新日期:2020-12-29 00:00:00

  • Surface coatings for ventricular assist devices.

    abstract::This article focuses on the surface engineering of ventricular assist devices (VADs) for the treatment of heart failure patients, which involves the modification of surfaces contacting blood in order to improve the blood compatibility (hemocompatibility) of the VADs. Following an introduction to the categorization and...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.6.1.51

    authors: Sin DC,Kei HL,Miao X

    更新日期:2009-01-01 00:00:00

  • Resurrection of hip resurfacing: what is the evidence?

    abstract::Total hip resurfacing has long been conceptually attractive to both surgeons and patients. However, historically it has been plagued by limited durability and marked acetabular bone loss. The recent development of wear-resistant bearings, such as metal-on-metal, has led to renewed interest in hip resurfacing in the or...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.3.6.755

    authors: Moroni A,Cadossi M,Bellenghi C,Romagnoli M,Bevoni R,Giannini S

    更新日期:2006-11-01 00:00:00

  • Currently available metacarpophalangeal prostheses: their designs and prospective considerations.

    abstract::Although implanted for over 40 years, finger prostheses have failed to match the success achieved by artificial hip and knee prostheses, despite a myriad of designs having been proposed and implanted. This article looks at the currently available designs of metacarpophalangeal prosthesis, both single-piece and multico...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.1.2.193

    authors: Joyce TJ

    更新日期:2004-11-01 00:00:00

  • Miniaturization of left ventricular assist devices: the ongoing trend.

    abstract::The shortage of appropriate donor hearts and the expanding pool of patients waiting for a heart transplantation have led to growing interest in alternative strategies, particularly in mechanical circulatory support. With expanding clinical experience and continued technical advances, continuous-flow pumps are evolving...

    journal_title:Expert review of medical devices

    pub_type: 历史文章,杂志文章,评审

    doi:10.1586/erd.11.62

    authors: Garbade J,Bittner HB,Lehmann S,Mohr FW,Barten MJ

    更新日期:2012-01-01 00:00:00

  • Biomolecular modification of implant surfaces.

    abstract::In this review, surface modification of implant devices by immobilization of biological molecules is discussed. A brief introduction to the development of biomolecular surface science is presented, followed by a review of current activities in selected fields. Bone-contacting devices and some cardiovascular implant de...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.4.3.361

    authors: Morra M

    更新日期:2007-05-01 00:00:00

  • Digital breast tomosynthesis (3D-mammography) screening: data and implications for population screening.

    abstract::The evidence on digital breast tomosynthesis (DBT), or quasi-3D-mammography, for population breast screening has emerged rapidly: two prospective and several retrospective studies provide convincing evidence that mammography with DBT improves screening detection measures compared with standard mammography. Based on po...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2015.1028362

    authors: Houssami N

    更新日期:2015-07-01 00:00:00

  • How prosthetic design influences knee kinematics: a narrative review of tibiofemoral kinematics of healthy and joint-replaced knees.

    abstract:INTRODUCTION:To improve the total knee arthroplasty (TKA) prosthesis design, it is essential to study the kinematics of the tibiofemoral joint. Many studies have been conducted in this area; however, conflicting results and incomparable testing methods make it difficult to draw definitive conclusions or compare researc...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2019.1564037

    authors: Meng F,Jaeger S,Sonntag R,Schroeder S,Smith-Romanski S,Kretzer JP

    更新日期:2019-02-01 00:00:00

  • Modeling of the medical device development process.

    abstract::Models are abstract representations of reality that are built, analyzed and manipulated to augment the understanding of that reality. They can either be mental or codified but, in both cases, they contribute to good decision-making by ensuring that the right people use the right information at the right time. In order...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/erd.12.36

    authors: Santos IC,Gazelle GS,Rocha LA,Tavares JM

    更新日期:2012-09-01 00:00:00

  • Strategies for replacing non-invasive brain stimulation sessions: recommendations for designing neurostimulation clinical trials.

    abstract:INTRODUCTION:Despite the potential impact of missed visits on the outcomes of neuromodulation treatments, it is not clear how this issue has been addressed in clinical trials. Given this gap in the literature, we reviewed articles on non-invasive brain stimulation in participants with depression or chronic pain, and in...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2017.1352470

    authors: Thibaut A,O'Brien AT,Fregni F

    更新日期:2017-08-01 00:00:00

  • Robotic navigation during spine surgery.

    abstract::Introduction: Potential complications associated with screw malposition may result in neurological deficits or vascular injuries. Spine surgery has significantly developed under the assistance of technological progress. The advantages of applying robotic technology in spine surgery include the possibility of improving...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2020.1699405

    authors: Zhang Q,Han XG,Xu YF,Fan MX,Zhao JW,Liu YJ,He D,Tian W

    更新日期:2020-01-01 00:00:00

  • Hemodialysis machine technology: a global overview.

    abstract::The market for hemodialysis machines, the background, the current products of manufacturers and the features of hemodialysis machines are described in this article. In addition to the established companies and their products, Chinese manufacturers, and new developments for home hemodialysis, are outlined based on publ...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/erd.10.54

    authors: Polaschegg HD

    更新日期:2010-11-01 00:00:00

  • The EluNIRTM Ridaforolimus Eluting Coronary Stent System.

    abstract:INTRODUCTION:First-generation drug-eluting stents (DES) were developed and indeed proved their superiority compared to bare-metal stent in minimizing neo-intimal hyperplasia and in-stent restenosis (ISR), overall, reducing target vessel revascularization (TVR). Newer-generation DES are characterized by thinner struts, ...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章

    doi:10.1080/17434440.2018.1549986

    authors: Savvoulidis P,Perlman G,Bagur R

    更新日期:2019-01-01 00:00:00

  • Thermal scalpel to target cancer.

    abstract::Nanotechnology is increasingly applied to the field of medicine, particularly for the treatment of cancer. In this regard, gold nanoparticles can mediate hyperthermia induction and kill tumor cells upon laser irradiation, thereby functioning as a 'thermal scalpel'. Recent developments in gold nanoparticle design have ...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.4.2.131

    authors: Everts M

    更新日期:2007-03-01 00:00:00

  • Device profile of the MobiusHD EVBA system for the treatment of resistant hypertension: overview of its mechanism of action, safety and efficacy.

    abstract:INTRODUCTION:Early promising results of renal nerve denervation awakened interest in developing medical device alternatives for patients with resistant hypertension. The subsequent sham-controlled renal nerve denervation randomized trials were disappointing leading researchers and innovators to explore alternative devi...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2020.1779054

    authors: Bates MC,Stone GW,Chen CY,Spiering W

    更新日期:2020-07-01 00:00:00

  • Carotid angioplasty and stenting under protection: advantages and drawbacks.

    abstract::Carotid stenosis is responsible for approximately 30% of strokes, and carotid endarterectomy is considered to be the gold-standard treatment. Carotid angioplasty and stenting (CAS) has been proposed as an alternative to surgery but the risk of neurological complications and brain embolism remains the major drawback to...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.5.5.591

    authors: Henry M,Polydorou A,Henry I,Polydorou AD,Hugel M

    更新日期:2008-09-01 00:00:00

  • Anti-infective therapy with an Er:YAG laser: influence on peri-implant healing.

    abstract::In addition to conventional treatment modalities (mechanical and chemical), the use of lasers has been increasingly proposed for the treatment of periodontal and peri-implant infections (i.e., cleaning and detoxification of implant surfaces). Preliminary results from basic studies have pointed to the high potential of...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2.3.267

    authors: Sculean A,Schwarz F,Becker J

    更新日期:2005-05-01 00:00:00

  • From drug eluting stents to bioresorbable scaffolds; to new horizons in PCI.

    abstract::Drug eluting stents and particularly the fully bioresorbable drug-eluting scaffolds herald a new era in percutaneous treatment of coronary artery disease. There has been tremendous progress in drug eluting stents with fully biodegradable coating polymers and polymer-free devices with reservoir technology planting the ...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2016.1143356

    authors: Tenekecioglu E,Bourantas C,Abdelghani M,Zeng Y,Silva RC,Tateishi H,Sotomi Y,Onuma Y,Yılmaz M,Serruys PW

    更新日期:2016-01-01 00:00:00

  • Cutting balloons, covered stents and paclitaxel-coated balloons for the treatment of dysfunctional dialysis access.

    abstract:INTRODUCTION:Percutaneous transcatheter balloon angioplasty has evolved to the current mainstay treatment for salvage of dysfunctional dialysis access. Nonetheless, it is frequently associated with recurrent vessel restenosis and the need for multiple repeat treatments in order to maintain hemodynamic patency. Cutting-...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2016.1254548

    authors: Kitrou P,Spiliopoulos S,Karnabatidis D,Katsanos K

    更新日期:2016-12-01 00:00:00

  • Performance of a new device for the clinical determination of light discomfort.

    abstract:PURPOSE:To assess the performance of a new device for the clinical determination of light discomfort on a large sample of healthy human subjects. METHODS:A total of 489 subjects ranging from 20 to 70 years old (241 men, 248 women) were evaluated with the LUMIZ™ 100 to determine light discomfort. Repeatability was asse...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章

    doi:10.1080/17434440.2020.1837623

    authors: Montés-Micó R,Cerviño A,Martínez-Albert N,García-Marqués JV,Marie S

    更新日期:2020-11-01 00:00:00