Does CircuLite Synergy assist device as partial ventricular support have a place in modern management of advanced heart failure?

Abstract:

:The discrepancy between the number of patients on the waiting list and available donor hearts has led to the successful development of left ventricular assist devices (LVAD) as a bridge to transplantation. The conventional LVADs are designed to provide full hemodynamic support for the end-stage failing heart. However, full-support LVAD implantation requires major surgery, sternotomy and cardiopulmonary bypass in majority of cases. The Synergy Micro-pump is the smallest implantable LVAD and provides partial flow support up to 3 l/min. It was shown that early intervention with this device can provide substantial benefits to patients with severe heart failure not yet sick enough for a full-support LVAD. Due the small dimensions it can be implanted without cardiopulmonary bypass or a sternotomy. The purpose of this article is to review the clinical use of the Synergy Micro-pump as partial hemodynamic support.

journal_name

Expert Rev Med Devices

authors

Mohite PN,Sabashnikov A,Simon AR,Weymann A,Patil NP,Unsoeld B,Bireta C,Popov AF

doi

10.1586/17434440.2015.985208

subject

Has Abstract

pub_date

2015-01-01 00:00:00

pages

49-60

issue

1

eissn

1743-4440

issn

1745-2422

journal_volume

12

pub_type

杂志文章,评审
  • In vivo nucleic acid delivery with PEI and its derivatives: current status and perspectives.

    abstract::Poly(ethylenimine) (PEI) has recently emerged as a favorable candidate for nucleic acid (NA) delivery because of its good effectivity at low cost. Despite copious derivatives and formulations being explored over the years, there is a scarcity of efforts to systematically review the current status and unmet needs of re...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/erd.10.83

    authors: Lai WF

    更新日期:2011-03-01 00:00:00

  • Performance of a new device for the clinical determination of light discomfort.

    abstract:PURPOSE:To assess the performance of a new device for the clinical determination of light discomfort on a large sample of healthy human subjects. METHODS:A total of 489 subjects ranging from 20 to 70 years old (241 men, 248 women) were evaluated with the LUMIZ™ 100 to determine light discomfort. Repeatability was asse...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章

    doi:10.1080/17434440.2020.1837623

    authors: Montés-Micó R,Cerviño A,Martínez-Albert N,García-Marqués JV,Marie S

    更新日期:2020-11-01 00:00:00

  • Patient-specific instrumentation in total knee arthroplasty.

    abstract:INTRODUCTION:Total knee arthroplasty (TKA) is one of the most commonly performed orthopedic procedures. During the past decade, patient-specific instrumentation (PSI) has been commercially introduced in order to simplify and make TKA surgery more effective, precise and efficient than conventional mechanical instrumenta...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2019.1627197

    authors: León-Muñoz VJ,Martínez-Martínez F,López-López M,Santonja-Medina F

    更新日期:2019-07-01 00:00:00

  • Neural machine interfaces for controlling multifunctional powered upper-limb prostheses.

    abstract::This article investigates various neural machine interfaces for voluntary control of externally powered upper-limb prostheses. Epidemiology of upper limb amputation, as well as prescription and follow-up studies of externally powered upper-limb prostheses are discussed. The use of electromyographic interfaces and peri...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.4.1.43

    authors: Ohnishi K,Weir RF,Kuiken TA

    更新日期:2007-01-01 00:00:00

  • Infections of electrophysiologic cardiac devices.

    abstract::Infections related to electrophysiologic cardiac device placement are increasing dramatically and are associated with adverse outcomes. With the US population aging and living longer, cardiac devices are utilized in an older population with significant comorbidities, making the threat from infectious complications sig...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.5.2.183

    authors: Uslan DZ

    更新日期:2008-03-01 00:00:00

  • Robot-assisted total hip arthroplasty.

    abstract::Precise and accurate biomechanical reconstruction during total hip arthroplasty (THA) is essential for durable long-term survivorship. Accurate fit of cementless hip implants is also crucial to reduce micromotion between the bone-implant interfaces to allow for stable osseointegration. Robotic technology aims to minim...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2016.1124018

    authors: Banerjee S,Cherian JJ,Elmallah RK,Pierce TP,Jauregui JJ,Mont MA

    更新日期:2016-01-01 00:00:00

  • Cardima Surgical Ablation System: a novel tool for cardiac ablation in the treatment of atrial fibrillation.

    abstract::Atrial fibrillation is a pervasive and difficult heart rhythm problem for more than 3 million Americans. Patients are plagued by myriad symptoms and are exposed to the risk of stroke. Attempts to restore normal rhythm with drug therapy have been largely unsuccessful and the complications associated with long-term anti...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/erd.09.9

    authors: Saltman AE

    更新日期:2009-05-01 00:00:00

  • Robotic navigation during spine surgery.

    abstract::Introduction: Potential complications associated with screw malposition may result in neurological deficits or vascular injuries. Spine surgery has significantly developed under the assistance of technological progress. The advantages of applying robotic technology in spine surgery include the possibility of improving...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2020.1699405

    authors: Zhang Q,Han XG,Xu YF,Fan MX,Zhao JW,Liu YJ,He D,Tian W

    更新日期:2020-01-01 00:00:00

  • Designing medical technology for resilience: integrating health economics and human factors approaches.

    abstract:INTRODUCTION:The slow adoption of innovation into healthcare calls into question the manner of evidence generation for medical technology. This paper identifies potential reasons for this including a lack of attention to human factors, poor evaluation of economic benefits, lack of understanding of the existing healthca...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章

    doi:10.1080/17434440.2018.1418661

    authors: Borsci S,Uchegbu I,Buckle P,Ni Z,Walne S,Hanna GB

    更新日期:2018-01-01 00:00:00

  • Developments in dosing aids and adherence devices for glaucoma therapy: current and future perspectives.

    abstract::Glaucoma is a leading cause of blindness worldwide. Currently, topical drops are the mainstay of treatment for patients who suffer from this chronic disease. Adherence to topical therapy is known to be affected by forgetfulness, frequent dosing requirements and physical limitations. Dosing and adherence aids are desig...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.4.2.261

    authors: Kahook MY

    更新日期:2007-03-01 00:00:00

  • Lung volume reduction with endobronchial valves in patients with emphysema.

    abstract:INTRODUCTION:Bronchoscopic lung volume reduction with endobronchial valves is a recently acknowledged treatment option in patients with severe emphysema and absence of interlobar collateral ventilation. In endobronchial valve treatment, implantation of one-way valves leads to deflation of a hyperinflated lung lobe. Mul...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章

    doi:10.1080/17434440.2018.1538780

    authors: Van Der Molen MC,Klooster K,Hartman JE,Slebos DJ

    更新日期:2018-11-01 00:00:00

  • Mechanical adjuncts for cardiocerebral resuscitation.

    abstract::Introduction: Cardiac arrest remains a worldwide health problem with very poor outcome. In the absence of bystander resuscitation, survival rates decrease by 10% per minute of arrest and global ischemia. Even the best manual chest compressions, however, can only produce a fraction of normal cardiac output and blood fl...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2019.1649135

    authors: Riess ML,Balzer C

    更新日期:2019-09-01 00:00:00

  • Portable device for the analysis of liver function: a boon to liver surgery and critical care.

    abstract::Liver biology, liver disease and its management present a myriad of challenges to clinicians. Difficulties arise in determining liver functional capacity, which must be effectively measured in a quantitative reproducible manner. Measurement of indocyanine green (ICG) clearance, an exceptional tool that has been used f...

    journal_title:Expert review of medical devices

    pub_type: 社论

    doi:10.1586/17434440.2016.1126178

    authors: Mobley CM,Zarrinpar A

    更新日期:2016-01-01 00:00:00

  • Intrasaccular flow-diversion for treatment of intracranial aneurysms: the Woven EndoBridge.

    abstract::Endovascular approach is now the first option for the treatment of most intracranial aneurysms (IA). However, remaining limitations are the suboptimal stability of aneurysm occlusion and the treatment of complex IA. The use of conventional and flow diverter stents has partially addressed these limitations. Nevertheles...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2014.907741

    authors: Mine B,Pierot L,Lubicz B

    更新日期:2014-05-01 00:00:00

  • Remote-controlled internal lengthening plate for distraction osteogenesis in pediatric patients.

    abstract:OBJECTIVES:Limb lengthening by distraction osteogenesis is a technique widely used to treat limb length discrepancy resulting from trauma, congenital limb defects and long bone non-union. For decades, patients have resorted to the Ilizarov apparatus, prone to pin tract infections and scarring. Although implantable leng...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章

    doi:10.1080/17434440.2019.1599283

    authors: Gaudreau J,Mekhail M,Hamdy R,Villemure I

    更新日期:2019-04-01 00:00:00

  • Clinical potential of implantable wireless sensors for orthopedic treatments.

    abstract:INTRODUCTION:Implantable wireless sensors have been used for real-time monitoring of chemicals and physical conditions of bones, tendons and muscles to diagnose and study orthopedic diseases and injuries. Due to the importance of these sensors in orthopedic care, a critical review, which not only analyzes the underlyin...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2018.1454310

    authors: Karipott SS,Nelson BD,Guldberg RE,Ong KG

    更新日期:2018-04-01 00:00:00

  • High flow nasal cannula in the emergency department: indications, safety  and effectiveness.

    abstract:INTRODUCTION:Heated humidified high flow nasal cannula therapy (HHHFNCT) is emerging as a popular non-invasive mode of respiratory support in adults and children. In recent years, its use has extended beyond the intensive care unit to other clinical areas. This review aims to explore the mechanism of action, indication...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2018.1548276

    authors: Wang J,Lee KP,Chong SL,Loi M,Lee JH

    更新日期:2018-12-01 00:00:00

  • Evaluation of Pipeline Flex delivery system for the treatment of unruptured aneurysms.

    abstract:INTRODUCTION:Refinements in endovascular technology have revolutionized the treatment of intracranial aneurysms (IAs) with the development of flow-diversion technology. The first generation of the Pipelin Embolization Device (PED) has demonstrated its safety and efficacy. However, the deployment technique was a difficu...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章

    doi:10.1080/17434440.2016.1231573

    authors: Aguilar-Salinas P,Brasiliense LB,Gonsales D,Mitchell B,Lima A,Sauvageau E,Hanel R

    更新日期:2016-10-01 00:00:00

  • Electrothermal bipolar vessel sealing system (LigaSure) for hemostasis during thyroid surgery: a comprehensive review.

    abstract::Conventional hemostatic technologies utilized in thyroid surgery include clamp-and-tie, clips and monopolar and bipolar diathermy. Over the last decade, there has been a major shift towards utilizing newer hemostatic technologies, most notably the electrothermal bipolar vessel sealing systems (EBVS) and the Harmonic S...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/erd.13.6

    authors: Butskiy O,Wiseman SM

    更新日期:2013-05-01 00:00:00

  • Resurrection of hip resurfacing: what is the evidence?

    abstract::Total hip resurfacing has long been conceptually attractive to both surgeons and patients. However, historically it has been plagued by limited durability and marked acetabular bone loss. The recent development of wear-resistant bearings, such as metal-on-metal, has led to renewed interest in hip resurfacing in the or...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.3.6.755

    authors: Moroni A,Cadossi M,Bellenghi C,Romagnoli M,Bevoni R,Giannini S

    更新日期:2006-11-01 00:00:00

  • Towards soft robotic devices for site-specific drug delivery.

    abstract::Considerable research efforts have recently been dedicated to the establishment of various drug delivery systems (DDS) that are mechanical/physical, chemical and biological/molecular DDS. In this paper, we report on the recent advances in site-specific drug delivery (site-specific, controlled, targeted or smart drug d...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2015.1091722

    authors: Alici G

    更新日期:2015-01-01 00:00:00

  • Devices for thoracic endovascular aortic repair of type B aortic dissection: is there any chance for Marfan syndrome?

    abstract:INTRODUCTION:Type B aortic dissection (TBAD) is a threatening event that may lead to death for aortic rupture or multivisceral malperfusion in the acute phase and offers a poor prognosis for long term survivors. Thoracic endovascular aortic repair (TEVAR) has become the preferential therapy in acute and chronic complic...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2020.1782735

    authors: Lovato L,Cefarelli M,Gatta E,Di Eusanio M,Fattori R

    更新日期:2020-07-01 00:00:00

  • Update on the management and associated challenges of adult patients treated with veno-arterial extracorporeal membrane oxygenation.

    abstract:INTRODUCTION:Currently, veno-arterial extracorporeal membrane oxygenation (VA ECMO) represents a valuable treatment option for patients presenting with severe cardiogenic shock. Although the overall usage of VA ECMO in experienced centers is expanding, some management aspects remain challenging, with no consensus among...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2019.1614439

    authors: Kado Y,Miyamoto T,Fukamachi K,Karimov JH

    更新日期:2019-06-01 00:00:00

  • Anti-infective therapy with an Er:YAG laser: influence on peri-implant healing.

    abstract::In addition to conventional treatment modalities (mechanical and chemical), the use of lasers has been increasingly proposed for the treatment of periodontal and peri-implant infections (i.e., cleaning and detoxification of implant surfaces). Preliminary results from basic studies have pointed to the high potential of...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2.3.267

    authors: Sculean A,Schwarz F,Becker J

    更新日期:2005-05-01 00:00:00

  • Carotid angioplasty and stenting under protection: advantages and drawbacks.

    abstract::Carotid stenosis is responsible for approximately 30% of strokes, and carotid endarterectomy is considered to be the gold-standard treatment. Carotid angioplasty and stenting (CAS) has been proposed as an alternative to surgery but the risk of neurological complications and brain embolism remains the major drawback to...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.5.5.591

    authors: Henry M,Polydorou A,Henry I,Polydorou AD,Hugel M

    更新日期:2008-09-01 00:00:00

  • Scaffolds for liver tissue engineering.

    abstract::This review focuses on the expanding role for biomaterials and polymer scaffolds in liver tissue engineering. Studies are subdivided into in vitro and in vivo approaches. The in vitro section of the review discusses the challenges specific to liver tissue engineering, and how the choice of scaffold and its structure i...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.3.1.21

    authors: Hammond JS,Beckingham IJ,Shakesheff KM

    更新日期:2006-01-01 00:00:00

  • Non-invasive assessment of gestational hemodynamics: benefits and limitations of impedance cardiography versus other techniques.

    abstract::To obtain data for maternal stroke volume and cardiac output during pregnancy, it is preferable to use a non-invasive, accurate and reproducible method. In this aspect, impedance cardiography is an excellent technique which is also highly accessible and easy to perform. This paper is a comprehensive review on the publ...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2013.853466

    authors: Staelens A,Tomsin K,Grieten L,Oben J,Mesens T,Spaanderman M,Jacquemyn Y,Gyselaers W

    更新日期:2013-11-01 00:00:00

  • Shortening hospital stay for thyroid surgery.

    abstract::The number of outpatient surgical procedures performed in hospitals, increases daily. In some countries, such as Italy, outpatient operations outnumber inpatient operations. The incidence of thyroid disorders and, in particular, the cancer forms, has been increasing sharply for many years in several countries. Even if...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.5.1.85

    authors: Dionigi G,Bacuzzi A,Rovera F,Boni L,Piantanida E,Tanda ML,Castano P,Annoni M,Bartalena L,Dionigi R

    更新日期:2008-01-01 00:00:00

  • How prosthetic design influences knee kinematics: a narrative review of tibiofemoral kinematics of healthy and joint-replaced knees.

    abstract:INTRODUCTION:To improve the total knee arthroplasty (TKA) prosthesis design, it is essential to study the kinematics of the tibiofemoral joint. Many studies have been conducted in this area; however, conflicting results and incomparable testing methods make it difficult to draw definitive conclusions or compare researc...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2019.1564037

    authors: Meng F,Jaeger S,Sonntag R,Schroeder S,Smith-Romanski S,Kretzer JP

    更新日期:2019-02-01 00:00:00

  • Differential effects of public and private funding in the medical device industry.

    abstract:INTRODUCTION:Funding for scientific advancement comes from two dominant sources: public funds used to generate knowledge, and private sector funds in the pursuit of commercial products. It is unclear how to compare the outputs of these two financial mechanisms because both sectors are motivated by common goods but are ...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章

    doi:10.1080/17434440.2018.1419866

    authors: Kang HD,Edelman ER,Ku DN

    更新日期:2018-02-01 00:00:00