Clinical potential of implantable wireless sensors for orthopedic treatments.

Abstract:

INTRODUCTION:Implantable wireless sensors have been used for real-time monitoring of chemicals and physical conditions of bones, tendons and muscles to diagnose and study orthopedic diseases and injuries. Due to the importance of these sensors in orthopedic care, a critical review, which not only analyzes the underlying technologies but also their clinical implementations and challenges, will provide a landscape view on their current state and their future clinical role. AREAS COVERED:By conducting an extensive literature search and following the leaders of orthopedic implantable wireless sensors, this review covers the battery-powered and battery-free wireless implantable sensor technologies, and describes their implementation for hips, knees, spine, and shoulder stress/strain monitoring. Their advantages, limitations, and clinical challenges are also described. EXPERT COMMENTARY:Currently, implantable wireless sensors are mostly limited for scientific investigations and demonstrative experiments. Although rapid advancement in sensors and wireless technologies will push the reliability and practicality of these sensors for clinical realization, regulatory constraints and financial viability in medical device industry may curtail their continuous adoption for clinical orthopedic applications. In the next five years, these sensors are expected to gain increased interest from researchers, but wide clinical adoption is still unlikely.

journal_name

Expert Rev Med Devices

authors

Karipott SS,Nelson BD,Guldberg RE,Ong KG

doi

10.1080/17434440.2018.1454310

subject

Has Abstract

pub_date

2018-04-01 00:00:00

pages

255-264

issue

4

eissn

1743-4440

issn

1745-2422

journal_volume

15

pub_type

杂志文章,评审
  • The Reveal LINQ insertable cardiac monitor.

    abstract::Insertable cardiac monitors (ICMs) are leadless subcutaneous devices that continuously monitor the heart rhythm and record events over a timeframe measured in years, allowing for the diagnosis of infrequent rhythm abnormalities that can be the cause of palpitations, syncope and stroke. To date, ICMs have primarily bee...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2014.953059

    authors: Tomson TT,Passman R

    更新日期:2015-01-01 00:00:00

  • Improving retrieval rates for retrievable inferior vena cava filters.

    abstract::The introduction of retrievable inferior vena cava (IVC) filters was an important step in the evolution of deep vein thrombosis/pulmonary embolism management. Their removability makes them preferred to permanent filters in many cases. IVC filter retrieval often occurs at a suboptimal rate, leading to complications ass...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/erd.12.65

    authors: Dixon A,Stavropoulos SW

    更新日期:2013-01-01 00:00:00

  • Surgical drilling of curved holes in bone - a patent review.

    abstract:INTRODUCTION:Conventional surgical drills are rigid straight instruments used to make holes in bones. They lack the ability to follow a curved pathway, making them impractical for several surgical procedures. For this reason, there is a continuous need for improved devices for surgical drilling of curved holes. AREAS ...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2019.1596794

    authors: Sendrowicz A,Scali M,Culmone C,Breedveld P

    更新日期:2019-04-01 00:00:00

  • Device safety and effectiveness in the pediatric population: a US FDA perspective.

    abstract::The US FDA recognizes that there are many challenges to ensuring that medical devices are used responsibly and safely in the pediatric population. Education plays a key role, and manufacturers and healthcare providers must be informed of medical device issues unique to the pediatric population. Healthcare workers and ...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章

    doi:10.1586/17434440.6.2.131

    authors: Samuels-Reid J,Cope JU,Morrison AE

    更新日期:2009-03-01 00:00:00

  • Systematic review of various laser intervention strategies for proliferative diabetic retinopathy.

    abstract::Diabetic retinopathy (DR) is a common complication of diabetes. DR obstructs blood supply to the retina and has serious and long-lasting detrimental effects on quality of life. Panretinal photocoagulation, a laser surgical intervention, is advocated for early treatment of DR to prevent visual loss; however, results fr...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2014.953057

    authors: Luo D,Zheng Z,Xu X,Fan Y,Zhu B,Liu K,Wang F,Sun X,Zou H,Xia X

    更新日期:2015-01-01 00:00:00

  • Top 100 cited noninvasive neuromodulation clinical trials.

    abstract:INTRODUCTION:Introduction: Transcranial direct current stimulation (tDCS) and transcranial magnetic stimulation (TMS) are noninvasive neuromodulation techniques used as therapeutic and research tools for several neuropsychiatric conditions. Given the exponential scientific growth of this field, we aimed to systematical...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2019.1615440

    authors: Lucena MFG,Teixeira PEP,Bonin Pinto C,Fregni F

    更新日期:2019-06-01 00:00:00

  • Perioperative monitoring of fluid responsiveness after esophageal surgery using stroke volume variation.

    abstract:OBJECTIVE:To assess the utility of a new arterial pressure-based cardiac output (FloTrac) and central venous oximetry (PreSep) monitoring system in the perioperative management of patients undergoing radical esophagectomy. CASE SERIES:From May 2006, a new analyzing device (Vigileo monitor; Edwards Lifesciences LLC, To...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章

    doi:10.1586/17434440.5.3.311

    authors: Kobayashi M,Ko M,Kimura T,Meguro E,Hayakawa Y,Irinoda T,Takagane A

    更新日期:2008-05-01 00:00:00

  • Robotics in invasive cardiac electrophysiology.

    abstract::Robotic systems allow for mapping and ablation of different arrhythmia substrates replacing hand maneuvering of intracardiac catheters with machine steering. Currently there are four commercially available robotic systems. Niobe magnetic navigation system (Stereotaxis Inc., St Louis, MO) and Sensei robotic navigation ...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2014.916207

    authors: Shurrab M,Schilling R,Gang E,Khan EM,Crystal E

    更新日期:2014-07-01 00:00:00

  • Modeling of the medical device development process.

    abstract::Models are abstract representations of reality that are built, analyzed and manipulated to augment the understanding of that reality. They can either be mental or codified but, in both cases, they contribute to good decision-making by ensuring that the right people use the right information at the right time. In order...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/erd.12.36

    authors: Santos IC,Gazelle GS,Rocha LA,Tavares JM

    更新日期:2012-09-01 00:00:00

  • Miniaturization of left ventricular assist devices: the ongoing trend.

    abstract::The shortage of appropriate donor hearts and the expanding pool of patients waiting for a heart transplantation have led to growing interest in alternative strategies, particularly in mechanical circulatory support. With expanding clinical experience and continued technical advances, continuous-flow pumps are evolving...

    journal_title:Expert review of medical devices

    pub_type: 历史文章,杂志文章,评审

    doi:10.1586/erd.11.62

    authors: Garbade J,Bittner HB,Lehmann S,Mohr FW,Barten MJ

    更新日期:2012-01-01 00:00:00

  • Intrasaccular flow-diversion for treatment of intracranial aneurysms: the Woven EndoBridge.

    abstract::Endovascular approach is now the first option for the treatment of most intracranial aneurysms (IA). However, remaining limitations are the suboptimal stability of aneurysm occlusion and the treatment of complex IA. The use of conventional and flow diverter stents has partially addressed these limitations. Nevertheles...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2014.907741

    authors: Mine B,Pierot L,Lubicz B

    更新日期:2014-05-01 00:00:00

  • New autoinjector technology for the delivery of subcutaneous methotrexate in the treatment of rheumatoid arthritis.

    abstract::Methotrexate (MTX) is the cornerstone of treatment for rheumatoid arthritis (RA), and is widely used both as first-line therapy and as an important component of long-term therapy. Although subcutaneous MTX is typically delivered orally, parenteral administration offers benefits with respect to tolerability and systemi...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2014.929492

    authors: Schiff M,Jaffe J,Freundlich B,Madsen P

    更新日期:2014-09-01 00:00:00

  • The role of active middle-ear implants in the rehabilitation of hearing loss.

    abstract::The surgical implantation of auditory devices to improve or restore the sensation of hearing in affected individuals is a rapidly growing area of modern ear, nose and throat, and audiological practice. Following the enormous success of cochlear implantation and set to take an increasing role in the rehabilitation of d...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/erd.11.18

    authors: Green K

    更新日期:2011-07-01 00:00:00

  • Device profile of the MobiusHD EVBA system for the treatment of resistant hypertension: overview of its mechanism of action, safety and efficacy.

    abstract:INTRODUCTION:Early promising results of renal nerve denervation awakened interest in developing medical device alternatives for patients with resistant hypertension. The subsequent sham-controlled renal nerve denervation randomized trials were disappointing leading researchers and innovators to explore alternative devi...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2020.1779054

    authors: Bates MC,Stone GW,Chen CY,Spiering W

    更新日期:2020-07-01 00:00:00

  • Could a new sensory pen assist in the early diagnosis of Parkinson's?

    abstract::Neurodegeneration in Parkinson's disease (PD) affects both the fine motor control of the fingers and gross movement of the upper limb. Handwriting examinations are commonly performed in the analysis of tremor in PD and there is validity in subjective assessment in the clinic. However, there is clinical need for a more...

    journal_title:Expert review of medical devices

    pub_type: 社论,评审

    doi:10.1586/17434440.2014.900437

    authors: Walker RW,Zietsma R,Gray WK

    更新日期:2014-05-01 00:00:00

  • Advanced methods of spinal stimulation in the treatment of chronic pain: pulse trains, waveforms, frequencies, targets, and feedback loops.

    abstract:INTRODUCTION:Spinal cord stimulation has emerged as a state-of-the-art evidence-based treatment for chronic neuropathic pain and mixed nociceptive-neuropathic pain. In recent years, several newer devices and treatment algorithms have provided unique and effective ways of treating chronic pain by spinal cord stimulation...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2019.1567325

    authors: Maheshwari A,Pope JE,Deer TR,Falowski S

    更新日期:2019-02-01 00:00:00

  • Evaluation of Surefire's precision direct-to-tumor embolization device to augment therapeutic response to intra-arterial, liver-directed therapies for patients with primary and secondary liver cancers.

    abstract::Patients with primary and secondary liver cancers generally have a poor prognosis with limited potentially curative options. Liver-directed, intra-arterial therapies such as selective internal radiotherapy (SIRT) and trans-arterial chemoembolization (TACE) are taking a larger role in the management of these patients. ...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章

    doi:10.1586/17434440.2016.1164594

    authors: Kim AY,Miller A

    更新日期:2016-05-01 00:00:00

  • The EluNIRTM Ridaforolimus Eluting Coronary Stent System.

    abstract:INTRODUCTION:First-generation drug-eluting stents (DES) were developed and indeed proved their superiority compared to bare-metal stent in minimizing neo-intimal hyperplasia and in-stent restenosis (ISR), overall, reducing target vessel revascularization (TVR). Newer-generation DES are characterized by thinner struts, ...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章

    doi:10.1080/17434440.2018.1549986

    authors: Savvoulidis P,Perlman G,Bagur R

    更新日期:2019-01-01 00:00:00

  • Device profile of the Resolute Onyx Zotarolimus eluting coronary stent system for the treatment of coronary artery disease: overview of its safety and efficacy.

    abstract::Introduction: The increasing complexity of patients undergoing percutaneous coronary intervention (PCI) regarding both coronary anatomy and comorbidities requires dedicated devices. The Resolute Onyx (R-Onyx, Medtronic, CA, USA) stent is a novel durable polymer zotarolimus-eluting stent (ZES) promising better delivera...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2020.1736037

    authors: Blum M,Cao D,Mehran R

    更新日期:2020-04-01 00:00:00

  • Safety considerations for deep brain stimulation: review and analysis.

    abstract::Deep brain stimulation has emerged rapidly as an effective therapy for movement disorders. Deep brain stimulation includes an implanted brain electrode and a pacemaker-like implanted pulse generator. The clinical application of deep brain stimulation proceeded in the absence of clear understandings of its mechanisms o...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2.4.409

    authors: Grill WM

    更新日期:2005-07-01 00:00:00

  • Infection prevention methodologies for lower extremity total joint arthroplasty.

    abstract::Despite advances in our understanding of surgical site infections following total joint arthroplasty, this serious surgical complication continues to represent a substantial economic burden for the patient, the treating institution and the healthcare system. After increasing for the past decade, infection rates have s...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/erd.12.76

    authors: Kapadia BH,Pivec R,Johnson AJ,Issa K,Naziri Q,Daley JA,Mont MA

    更新日期:2013-03-01 00:00:00

  • Anti-infective therapy with an Er:YAG laser: influence on peri-implant healing.

    abstract::In addition to conventional treatment modalities (mechanical and chemical), the use of lasers has been increasingly proposed for the treatment of periodontal and peri-implant infections (i.e., cleaning and detoxification of implant surfaces). Preliminary results from basic studies have pointed to the high potential of...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2.3.267

    authors: Sculean A,Schwarz F,Becker J

    更新日期:2005-05-01 00:00:00

  • Evolution of endovascular stroke therapies and devices.

    abstract::Acute ischemic stroke is caused by occlusion of a cerebral artery, resulting in loss of brain tissue and neurologic deficits. However, a portion of the ischemic brain can be salvaged if blood flow is restored within an appropriate time frame. The past year has seen the publication of five positive randomized controlle...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2016.1143772

    authors: Wallace AN,Kansagra AP,McEachern J,Moran CJ,Cross DT 3rd,Derdeyn CP

    更新日期:2016-01-01 00:00:00

  • Continuous-flow left ventricular assist device implantation in patients with preexisting mechanical mitral valves: a systematic review.

    abstract::Introduction: A preexisting mechanical mitral valve (MMV) is thought to be a thrombogenic risk factor after continuous-flow left ventricular assist device (CF-LVAD) implantation. We sought to evaluate the management and outcomes of preexisting MMVs in patients following CF-LVAD implantation.Areas covered: An electroni...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章

    doi:10.1080/17434440.2020.1754190

    authors: Gordon JS,O'Malley TJ,Maynes EJ,Wood CT,Kalantri N,Morris RJ,Samuels LE,Massey HT,Tchantchaleishvili V

    更新日期:2020-05-01 00:00:00

  • Is there an alternative to systemic anticoagulation, as related to interventional biomedical devices?

    abstract::To reduce the toxic effects, related clinical problems and complications such as bleeding disorders associated with systemic anticoagulation, it has been hypothesized that by coating the surfaces of medical devices, such as stents, bypass grafts, extracorporeal circuits, guide wires and catheters, there will be a sign...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章

    doi:10.1586/17434440.3.2.245

    authors: Conn G,Kidane AG,Punshon G,Kannan RY,Hamilton G,Seifalian AM

    更新日期:2006-03-01 00:00:00

  • From portable dialysis to a bioengineered kidney.

    abstract:INTRODUCTION:Since the advent of peritoneal dialysis (PD) in the 1970s, the principles of dialysis have changed little. In the coming decades, several major breakthroughs are expected. AREAS COVERED:Novel wearable and portable dialysis devices for both hemodialysis (HD) and PD are expected first. The HD devices could ...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2018.1462697

    authors: van Gelder MK,Mihaila SM,Jansen J,Wester M,Verhaar MC,Joles JA,Stamatialis D,Masereeuw R,Gerritsen KGF

    更新日期:2018-05-01 00:00:00

  • Evaluation of the WATCHMAN left atrial appendage closure device.

    abstract::Left atrial appendage device occlusion for the preventions of systemic thromboembolism and stroke represents a major breakthrough in the field of cardiovascular disease. The wide prevalence of atrial fibrillation with devastating consequences of thromboembolic stroke as a result of thrombus arising from the left atria...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2014.940315

    authors: Alli O,Holmes D Jr

    更新日期:2014-11-01 00:00:00

  • Insertable cardiac monitors: current indications and devices.

    abstract:INTRODUCTION:Recurrent unexplained syncope is a well-established indication for an insertable cardiac monitor (ICM). Recently, the indications for an ICM have been expanded. AREAS COVERED:This review article discusses the current indications for ICMs and gives an overview of the latest generation of commercially avail...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2018.1557046

    authors: Sakhi R,Theuns DAMJ,Szili-Torok T,Yap SC

    更新日期:2019-01-01 00:00:00

  • The Visible Heart® project and methodologies: novel use for studying cardiac monophasic action potentials and evaluating their underlying mechanisms.

    abstract:INTRODUCTION:This review describes the utilization of Visible Heart® methodologies for electrophysiologic studies, specifically in the investigation of monophasic action potential (MAP) recordings, with the aim to facilitate new catheter/device design and development that may lead to earlier diagnosis, treatment, and u...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2018.1493922

    authors: Schmidt MM,Iaizzo PA

    更新日期:2018-07-01 00:00:00

  • Mechanical adjuncts for cardiocerebral resuscitation.

    abstract::Introduction: Cardiac arrest remains a worldwide health problem with very poor outcome. In the absence of bystander resuscitation, survival rates decrease by 10% per minute of arrest and global ischemia. Even the best manual chest compressions, however, can only produce a fraction of normal cardiac output and blood fl...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2019.1649135

    authors: Riess ML,Balzer C

    更新日期:2019-09-01 00:00:00