Surgical drilling of curved holes in bone - a patent review.

Abstract:

INTRODUCTION:Conventional surgical drills are rigid straight instruments used to make holes in bones. They lack the ability to follow a curved pathway, making them impractical for several surgical procedures. For this reason, there is a continuous need for improved devices for surgical drilling of curved holes. AREAS COVERED:This review provides a comprehensive overview and classification of the patent literature of surgical drills able to produce a curved hole. The goal is to identify the fundamental mechanical designs of the drills. The medical section of the Web of Science Derwent Innovation Index was scanned combining keywords for both steering and drilling. Overall, 41 unique patents were reviewed and categorized. EXPERT OPINION:Drills were subdivided in four groups based on the capability of either drilling a single curved path or a multi-curved path and on their ability to adjust the path after insertion of the drill into the bone. We found patents describing instrument designs for all these four groups. The insight in the drilling capabilities and in the mechanical designs described in the patents may serve as a source of inspiration for the design of novel surgical drills and the development of new surgical procedures.

journal_name

Expert Rev Med Devices

authors

Sendrowicz A,Scali M,Culmone C,Breedveld P

doi

10.1080/17434440.2019.1596794

subject

Has Abstract

pub_date

2019-04-01 00:00:00

pages

287-298

issue

4

eissn

1743-4440

issn

1745-2422

journal_volume

16

pub_type

杂志文章,评审
  • Potential of APDM mobility lab for the monitoring of the progression of Parkinson's disease.

    abstract::APDM's Mobility Lab system provides portable, validated, reliable, objective measures of balance and gait that are sensitive to Parkinson's disease (PD). In this review, we describe the potential of objective measures collected with the Mobility Lab system for tracking longitudinal progression of PD. Balance and gait ...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2016.1153421

    authors: Mancini M,Horak FB

    更新日期:2016-05-01 00:00:00

  • Amplatzer Duct Occluder device: a new technology for the closure of the moderate-to-large-sized patent ductus arteriosus.

    abstract::The Amplatzer Duct Occluder is a novel device designed to allow for the transcatheter closure of virtually all sized patent ductus arteriosuses. Prior technologies have been cumbersome and challenging to deploy with somewhat less than ideal closure rates associated with their use. This article summarizes the present k...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章

    doi:10.1586/17434440.3.3.291

    authors: Pass RH

    更新日期:2006-05-01 00:00:00

  • Percutaneous laser ablation of cervical metastatic lymph nodes in papillary thyroid carcinoma: clinical efficacy and anatomical considerations.

    abstract::Background: Papillary thyroid carcinoma is the most common type of thyroid cancer; despite its generally indolent course, patients often develop local post-operative recurrences. Re-operation, however, holds a high complication rate, while at the same time, not all patients benefit from radioiodine ablation. This syst...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章

    doi:10.1080/17434440.2021.1864323

    authors: Spartalis E,Karagiannis SP,Plakopitis N,Theodori MA,Athanasiadis DI,Schizas D,Spartalis M,Troupis T

    更新日期:2020-12-29 00:00:00

  • Clinical role of fluorescence imaging in colorectal surgery - a review.

    abstract:INTRODUCTION:Anastomotic leak (AL) after colorectal surgery is a devastating complication; decreased blood perfusion is an important risk factor. Surgeons rely on subjective measures to assess bowel perfusion. Fluorescence imaging (FI) with indocyanine green (ICG) provides a real-time objective assessment of intestinal...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,meta分析,评审

    doi:10.1080/17434440.2017.1265444

    authors: Mizrahi I,Wexner SD

    更新日期:2017-01-01 00:00:00

  • Scientific evidence for the use of modern patellofemoral arthroplasty.

    abstract::Patellofemoral arthroplasty has been utilized as a treatment for isolated patellofemoral arthritis for more than 30 years. However, the use of this procedure remains controversial, as many surgeons prefer to use total knee arthroplasty, even for isolated patellofemoral arthritis. While historically, the results with t...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章

    doi:10.1586/erd.09.53

    authors: Gupta RR,Zywiel MG,Leadbetter WB,Bonutti P,Mont MA

    更新日期:2010-01-01 00:00:00

  • Lung volume reduction with endobronchial valves in patients with emphysema.

    abstract:INTRODUCTION:Bronchoscopic lung volume reduction with endobronchial valves is a recently acknowledged treatment option in patients with severe emphysema and absence of interlobar collateral ventilation. In endobronchial valve treatment, implantation of one-way valves leads to deflation of a hyperinflated lung lobe. Mul...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章

    doi:10.1080/17434440.2018.1538780

    authors: Van Der Molen MC,Klooster K,Hartman JE,Slebos DJ

    更新日期:2018-11-01 00:00:00

  • Could a new sensory pen assist in the early diagnosis of Parkinson's?

    abstract::Neurodegeneration in Parkinson's disease (PD) affects both the fine motor control of the fingers and gross movement of the upper limb. Handwriting examinations are commonly performed in the analysis of tremor in PD and there is validity in subjective assessment in the clinic. However, there is clinical need for a more...

    journal_title:Expert review of medical devices

    pub_type: 社论,评审

    doi:10.1586/17434440.2014.900437

    authors: Walker RW,Zietsma R,Gray WK

    更新日期:2014-05-01 00:00:00

  • Perioperative monitoring of fluid responsiveness after esophageal surgery using stroke volume variation.

    abstract:OBJECTIVE:To assess the utility of a new arterial pressure-based cardiac output (FloTrac) and central venous oximetry (PreSep) monitoring system in the perioperative management of patients undergoing radical esophagectomy. CASE SERIES:From May 2006, a new analyzing device (Vigileo monitor; Edwards Lifesciences LLC, To...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章

    doi:10.1586/17434440.5.3.311

    authors: Kobayashi M,Ko M,Kimura T,Meguro E,Hayakawa Y,Irinoda T,Takagane A

    更新日期:2008-05-01 00:00:00

  • Comparison of stents used for endovascular treatment of intracranial aneurysms.

    abstract:INTRODUCTION:Stent-assisted coiling (SAC) has widened indications of endovascular treatment of intracranial aneurysms (wide-neck, fusiform aneurysms); moreover, it is associated with more stable anatomical results. Besides the development of other techniques such as flow diverter stents, bifurcation stents, or intrasac...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2018.1538779

    authors: Mine B,Bonnet T,Vazquez-Suarez JC,Iosif C,Lubicz B

    更新日期:2018-11-01 00:00:00

  • Portable device for the analysis of liver function: a boon to liver surgery and critical care.

    abstract::Liver biology, liver disease and its management present a myriad of challenges to clinicians. Difficulties arise in determining liver functional capacity, which must be effectively measured in a quantitative reproducible manner. Measurement of indocyanine green (ICG) clearance, an exceptional tool that has been used f...

    journal_title:Expert review of medical devices

    pub_type: 社论

    doi:10.1586/17434440.2016.1126178

    authors: Mobley CM,Zarrinpar A

    更新日期:2016-01-01 00:00:00

  • Evaluation of Surefire's precision direct-to-tumor embolization device to augment therapeutic response to intra-arterial, liver-directed therapies for patients with primary and secondary liver cancers.

    abstract::Patients with primary and secondary liver cancers generally have a poor prognosis with limited potentially curative options. Liver-directed, intra-arterial therapies such as selective internal radiotherapy (SIRT) and trans-arterial chemoembolization (TACE) are taking a larger role in the management of these patients. ...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章

    doi:10.1586/17434440.2016.1164594

    authors: Kim AY,Miller A

    更新日期:2016-05-01 00:00:00

  • Sleep assessment devices: types, market analysis, and a critical view on accuracy and validation.

    abstract::Introduction: Sleep assessment devices are essential for the detection, diagnosis, and monitoring of sleep disorders. This paper provides a state-of-the-art review and comparison of sleep assessment devices and a market analysis.Areas covered: Hardware devices are classified into contact and contactless devices. For e...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2019.1693890

    authors: Ibáñez V,Silva J,Navarro E,Cauli O

    更新日期:2019-12-01 00:00:00

  • Wearable inertial sensors for human movement analysis.

    abstract:INTRODUCTION:The present review aims to provide an overview of the most common uses of wearable inertial sensors in the field of clinical human movement analysis. AREAS COVERED:Six main areas of application are analysed: gait analysis, stabilometry, instrumented clinical tests, upper body mobility assessment, daily-li...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2016.1198694

    authors: Iosa M,Picerno P,Paolucci S,Morone G

    更新日期:2016-07-01 00:00:00

  • Crux vena cava filter.

    abstract::Inferior vena cava filters are widely accepted for pulmonary embolic prophylaxis in high-risk patients with contraindications to anticoagulation. While long-term complications have been associated with permanent filters, retrievable filters are now available and have resulted in the rapid expansion of this technology....

    journal_title:Expert review of medical devices

    pub_type: 杂志文章

    doi:10.1586/erd.09.25

    authors: Murphy EH,Johnson ED,Kopchok GE,Fogarty TJ,Arko FR

    更新日期:2009-09-01 00:00:00

  • Evolution of endovascular stroke therapies and devices.

    abstract::Acute ischemic stroke is caused by occlusion of a cerebral artery, resulting in loss of brain tissue and neurologic deficits. However, a portion of the ischemic brain can be salvaged if blood flow is restored within an appropriate time frame. The past year has seen the publication of five positive randomized controlle...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2016.1143772

    authors: Wallace AN,Kansagra AP,McEachern J,Moran CJ,Cross DT 3rd,Derdeyn CP

    更新日期:2016-01-01 00:00:00

  • Hemodialysis machine technology: a global overview.

    abstract::The market for hemodialysis machines, the background, the current products of manufacturers and the features of hemodialysis machines are described in this article. In addition to the established companies and their products, Chinese manufacturers, and new developments for home hemodialysis, are outlined based on publ...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/erd.10.54

    authors: Polaschegg HD

    更新日期:2010-11-01 00:00:00

  • Wearable sensors to improve detection of patient deterioration.

    abstract:INTRODUCTION:Monitoring a patient's vital signs forms a basic component of care, enabling the identification of deteriorating patients and increasing the likelihood of improving patient outcomes. Several paper-based track and trigger warning scores have been developed to allow clinical evaluation of a patient and guida...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2019.1563480

    authors: Joshi M,Ashrafian H,Aufegger L,Khan S,Arora S,Cooke G,Darzi A

    更新日期:2019-02-01 00:00:00

  • New autoinjector technology for the delivery of subcutaneous methotrexate in the treatment of rheumatoid arthritis.

    abstract::Methotrexate (MTX) is the cornerstone of treatment for rheumatoid arthritis (RA), and is widely used both as first-line therapy and as an important component of long-term therapy. Although subcutaneous MTX is typically delivered orally, parenteral administration offers benefits with respect to tolerability and systemi...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2014.929492

    authors: Schiff M,Jaffe J,Freundlich B,Madsen P

    更新日期:2014-09-01 00:00:00

  • Modeling of the medical device development process.

    abstract::Models are abstract representations of reality that are built, analyzed and manipulated to augment the understanding of that reality. They can either be mental or codified but, in both cases, they contribute to good decision-making by ensuring that the right people use the right information at the right time. In order...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/erd.12.36

    authors: Santos IC,Gazelle GS,Rocha LA,Tavares JM

    更新日期:2012-09-01 00:00:00

  • The Lean and Agile Multi-dimensional Process (LAMP) - a new framework for rapid and iterative evidence generation to support health-care technology design and development.

    abstract::Introduction: Health technology assessments (HTA) are tools for policymaking and resource allocation. Early HTAs are increasingly used in design and development of new technologies. Conducting early HTAs is challenging, due to a lack of evidence and significant uncertainties in the technology and the market. A multi-d...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2020.1743174

    authors: Ni M,Borsci S,Walne S,Mclister AP,Buckle P,Barlow JG,Hanna GB

    更新日期:2020-04-01 00:00:00

  • Robot-assisted total hip arthroplasty.

    abstract::Precise and accurate biomechanical reconstruction during total hip arthroplasty (THA) is essential for durable long-term survivorship. Accurate fit of cementless hip implants is also crucial to reduce micromotion between the bone-implant interfaces to allow for stable osseointegration. Robotic technology aims to minim...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2016.1124018

    authors: Banerjee S,Cherian JJ,Elmallah RK,Pierce TP,Jauregui JJ,Mont MA

    更新日期:2016-01-01 00:00:00

  • Endoscopy-guided vitreoretinal surgery.

    abstract::Vitreoretinal surgery has recently undergone remarkable developments. The introduction of micro-incision vitrectomy surgery using 25- and 23-gauge techniques has led to minimally invasive, faster, safer, and more accurate surgeries. Similarly, intraocular illumination and observation systems have advanced from light p...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2014.882226

    authors: Kawashima S,Kawashima M,Tsubota K

    更新日期:2014-03-01 00:00:00

  • Cutting balloons, covered stents and paclitaxel-coated balloons for the treatment of dysfunctional dialysis access.

    abstract:INTRODUCTION:Percutaneous transcatheter balloon angioplasty has evolved to the current mainstay treatment for salvage of dysfunctional dialysis access. Nonetheless, it is frequently associated with recurrent vessel restenosis and the need for multiple repeat treatments in order to maintain hemodynamic patency. Cutting-...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2016.1254548

    authors: Kitrou P,Spiliopoulos S,Karnabatidis D,Katsanos K

    更新日期:2016-12-01 00:00:00

  • Continuous-flow left ventricular assist device implantation in patients with preexisting mechanical mitral valves: a systematic review.

    abstract::Introduction: A preexisting mechanical mitral valve (MMV) is thought to be a thrombogenic risk factor after continuous-flow left ventricular assist device (CF-LVAD) implantation. We sought to evaluate the management and outcomes of preexisting MMVs in patients following CF-LVAD implantation.Areas covered: An electroni...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章

    doi:10.1080/17434440.2020.1754190

    authors: Gordon JS,O'Malley TJ,Maynes EJ,Wood CT,Kalantri N,Morris RJ,Samuels LE,Massey HT,Tchantchaleishvili V

    更新日期:2020-05-01 00:00:00

  • In vivo nucleic acid delivery with PEI and its derivatives: current status and perspectives.

    abstract::Poly(ethylenimine) (PEI) has recently emerged as a favorable candidate for nucleic acid (NA) delivery because of its good effectivity at low cost. Despite copious derivatives and formulations being explored over the years, there is a scarcity of efforts to systematically review the current status and unmet needs of re...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/erd.10.83

    authors: Lai WF

    更新日期:2011-03-01 00:00:00

  • Towards soft robotic devices for site-specific drug delivery.

    abstract::Considerable research efforts have recently been dedicated to the establishment of various drug delivery systems (DDS) that are mechanical/physical, chemical and biological/molecular DDS. In this paper, we report on the recent advances in site-specific drug delivery (site-specific, controlled, targeted or smart drug d...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2015.1091722

    authors: Alici G

    更新日期:2015-01-01 00:00:00

  • Driving restriction in patients with cardiac implantable electronic devices: an overview of worldwide regulations.

    abstract::Introduction: It is common belief that driving with an implantable cardioverter defibrillator (ICD)/pacemaker (PM) might be associated with sudden cardiac incapacitation, road traffic accidents, and chance to harm to self and others. On the other hand, the ability to drive is highly valuable in the modern era, represe...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2020.1742108

    authors: Imberti JF,Vitolo M,Proietti M,Diemberger I,Ziacchi M,Biffi M,Boriani G

    更新日期:2020-04-01 00:00:00

  • Right heart transcatheter valve therapies - a review of prostheses for the pulmonary and tricuspid positions.

    abstract::Minimally invasive, catheter-based treatment of valvular dysfunction has become an integral part of clinical routine. As left heart valvular disease is much more common and thus commercially of interest, transcatheter solutions for the treatment of aortic and mitral valvular defects were the first to become broadly cl...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2015.985654

    authors: Kuetting M,Pott D,Sedaghat A,Ng YA,Egron S,Rosefort C,Werner N,Sachweh J,Steinseifer U

    更新日期:2015-03-01 00:00:00

  • Computer-aided design and manufacturing of surgical templates and their clinical applications: a review.

    abstract:INTRODUCTION:The surgical template is a guide aimed at directing the implant placement, tumor resection, osteotomy and bone repositioning. Using it, preoperative planning can be transferred to the actual surgical site, and the precision, safety and reliability of the surgery can be improved. However, the actual workflo...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2016.1218758

    authors: Chen X,Xu L,Wang W,Li X,Sun Y,Politis C

    更新日期:2016-09-01 00:00:00

  • Catheter directed interventions for pulmonary embolism: current status and future prospects.

    abstract::Introduction: Catheter directed interventions (CDIs) have evolved over the past decade in an attempt to reduce the complications of systemic thrombolysis, while providing equivalent therapeutic benefits.Areas covered: CDIs include a wide array of catheters that incorporate ultrasound technology, the infusion of thromb...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2020.1714432

    authors: Abou Ali AN,Saadeddin Z,Chaer RA,Avgerinos ED

    更新日期:2020-02-01 00:00:00