Crux vena cava filter.

Abstract:

:Inferior vena cava filters are widely accepted for pulmonary embolic prophylaxis in high-risk patients with contraindications to anticoagulation. While long-term complications have been associated with permanent filters, retrievable filters are now available and have resulted in the rapid expansion of this technology. Nonetheless, complications are still reported with optional filters. Furthermore, device tilting and thrombus load may prevent retrieval in up to 30% of patients, thereby eliminating the benefits of this technology. The Crux vena cava filter is a novel, self-centering, low-profile filter that is designed for ease of delivery, retrievability and improved efficacy while limiting fatigue-related device complications. This device has been proven safe and user-friendly in an ovine model and has recently been implanted in human subjects.

journal_name

Expert Rev Med Devices

authors

Murphy EH,Johnson ED,Kopchok GE,Fogarty TJ,Arko FR

doi

10.1586/erd.09.25

subject

Has Abstract

pub_date

2009-09-01 00:00:00

pages

477-85

issue

5

eissn

1743-4440

issn

1745-2422

journal_volume

6

pub_type

杂志文章
  • Could a new sensory pen assist in the early diagnosis of Parkinson's?

    abstract::Neurodegeneration in Parkinson's disease (PD) affects both the fine motor control of the fingers and gross movement of the upper limb. Handwriting examinations are commonly performed in the analysis of tremor in PD and there is validity in subjective assessment in the clinic. However, there is clinical need for a more...

    journal_title:Expert review of medical devices

    pub_type: 社论,评审

    doi:10.1586/17434440.2014.900437

    authors: Walker RW,Zietsma R,Gray WK

    更新日期:2014-05-01 00:00:00

  • An ultrasensitive young interferometer handheld sensor for rapid virus detection.

    abstract::Future viral outbreaks are a major threat to societal and economic development throughout the world. A rapid, sensitive and easy-to-use test for viral infections is essential to prevent and control such viral pandemics. Furthermore, a compact, portable device is potentially very useful in remote or developing regions ...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章

    doi:10.1586/17434440.4.4.447

    authors: Ymeti A,Subramaniam V,Beumer TA,Kanger JS

    更新日期:2007-07-01 00:00:00

  • Using medical imaging for the detection of adverse events ("incidents") during the utilization of left ventricular assist devices in adult patients with advanced heart failure.

    abstract::Ventricular assist devices (VAD) are used for mechanical support of the terminally failing heart. Failure of these life supporting systems can be fatal. Early and reliable detection of any upcoming problems is mandatory and is crucial for the outcome. Medical imaging methods are described within this review, which are...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2016.1166051

    authors: Kaufmann F,Krabatsch T

    更新日期:2016-05-01 00:00:00

  • A critical appraisal of cardiac ablation technology for catheter-based treatment of atrial fibrillation.

    abstract::The advent of catheter ablation has revolutionized the treatment of supraventricular cardiac arrhythmias, including in the last few years, atrial fibrillation. The discovery of electrically active sleeves of atrial myocardium extending into the pulmonary veins has led to the development of pulmonary vein ostial ablati...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/erd.10.59

    authors: Shah D

    更新日期:2011-01-01 00:00:00

  • Electrosurgical devices: are we closer to finding the ideal appliance? A critical review of current evidence for the use of electrosurgical devices in general surgery.

    abstract::Over the last decade, the use of electrosurgical devices has become commonplace across all surgical specialities. The current market is large enough to warrant a comparative review of each device. This has even more impetus given the budgetary constraints of NHS organisations. This review aims to compare the benefits ...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章

    doi:10.1586/17434440.2016.1134312

    authors: Sran H,Sebastian J,Hossain MA

    更新日期:2016-01-01 00:00:00

  • Miniaturization of left ventricular assist devices: the ongoing trend.

    abstract::The shortage of appropriate donor hearts and the expanding pool of patients waiting for a heart transplantation have led to growing interest in alternative strategies, particularly in mechanical circulatory support. With expanding clinical experience and continued technical advances, continuous-flow pumps are evolving...

    journal_title:Expert review of medical devices

    pub_type: 历史文章,杂志文章,评审

    doi:10.1586/erd.11.62

    authors: Garbade J,Bittner HB,Lehmann S,Mohr FW,Barten MJ

    更新日期:2012-01-01 00:00:00

  • Comparison of stents used for endovascular treatment of intracranial aneurysms.

    abstract:INTRODUCTION:Stent-assisted coiling (SAC) has widened indications of endovascular treatment of intracranial aneurysms (wide-neck, fusiform aneurysms); moreover, it is associated with more stable anatomical results. Besides the development of other techniques such as flow diverter stents, bifurcation stents, or intrasac...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2018.1538779

    authors: Mine B,Bonnet T,Vazquez-Suarez JC,Iosif C,Lubicz B

    更新日期:2018-11-01 00:00:00

  • Shields and garb for decreasing radiation exposure in the cath lab.

    abstract:INTRODUCTION:Decreasing radiation exposure of the cardiac catheterization laboratory staff is critical for minimizing radiation-related adverse outcomes and can be accomplished by decreasing patient dose and by shielding. Areas covered: protection from ionizing radiation can be achieved with architectural, equipment-mo...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2018.1510771

    authors: Karatasakis A,Brilakis ES

    更新日期:2018-09-01 00:00:00

  • Continuous-flow left ventricular assist device implantation in patients with preexisting mechanical mitral valves: a systematic review.

    abstract::Introduction: A preexisting mechanical mitral valve (MMV) is thought to be a thrombogenic risk factor after continuous-flow left ventricular assist device (CF-LVAD) implantation. We sought to evaluate the management and outcomes of preexisting MMVs in patients following CF-LVAD implantation.Areas covered: An electroni...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章

    doi:10.1080/17434440.2020.1754190

    authors: Gordon JS,O'Malley TJ,Maynes EJ,Wood CT,Kalantri N,Morris RJ,Samuels LE,Massey HT,Tchantchaleishvili V

    更新日期:2020-05-01 00:00:00

  • Clinical potential of implantable wireless sensors for orthopedic treatments.

    abstract:INTRODUCTION:Implantable wireless sensors have been used for real-time monitoring of chemicals and physical conditions of bones, tendons and muscles to diagnose and study orthopedic diseases and injuries. Due to the importance of these sensors in orthopedic care, a critical review, which not only analyzes the underlyin...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2018.1454310

    authors: Karipott SS,Nelson BD,Guldberg RE,Ong KG

    更新日期:2018-04-01 00:00:00

  • Single-step atrial thrombus exclusion and transesophageal cardioversion in atrial fibrillation.

    abstract::Atrial fibrillation (AF), the most common arrhythmia, has a major impact on both patient morbidity and healthcare economics. Hospital admissions due to AF have risen by two-thirds in the last 20 years. This is due mainly to an aging population and an increasing prevalence of chronic heart disease. Strategies for the m...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.4.4.549

    authors: Mischke K,Schimpf T,Knackstedt C,Hanrath P,Schauerte P

    更新日期:2007-07-01 00:00:00

  • Developments in dosing aids and adherence devices for glaucoma therapy: current and future perspectives.

    abstract::Glaucoma is a leading cause of blindness worldwide. Currently, topical drops are the mainstay of treatment for patients who suffer from this chronic disease. Adherence to topical therapy is known to be affected by forgetfulness, frequent dosing requirements and physical limitations. Dosing and adherence aids are desig...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.4.2.261

    authors: Kahook MY

    更新日期:2007-03-01 00:00:00

  • Imaging techniques in pancreatic tumors.

    abstract::Conventional ultrasonography represents the first diagnostic imaging modality for the study of pancreatic tumors. Contrast-enhanced ultrasound has significantly improved the accuracy of first-line examination and may influence the choice of second-line investigations: multidetector computed tomography is considered th...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/erd.09.67

    authors: D'Onofrio M,Gallotti A,Pozzi Mucelli R

    更新日期:2010-03-01 00:00:00

  • Currently available metacarpophalangeal prostheses: their designs and prospective considerations.

    abstract::Although implanted for over 40 years, finger prostheses have failed to match the success achieved by artificial hip and knee prostheses, despite a myriad of designs having been proposed and implanted. This article looks at the currently available designs of metacarpophalangeal prosthesis, both single-piece and multico...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.1.2.193

    authors: Joyce TJ

    更新日期:2004-11-01 00:00:00

  • Laparoscopic cholecystectomy: device-related errors revealed through a national database.

    abstract::Laparoscopic techniques represent a key milestone in the development of modern surgery, offering a step change in quality of care, patient satisfaction and efficiency in use of health service resources. Laparoscopy is most widely used for gall bladder surgery. As would be expected with the introduction of any new tech...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/erd.11.43

    authors: Panesar SS,Salvilla SA,Patel B,Donaldson SL

    更新日期:2011-09-01 00:00:00

  • Current interventional coronary applications of excimer laser.

    abstract::Excimer laser utilization as an adjunctive device for percutaneous coronary intervention has increased in the last few years. Many technical advancements have led to better results in terms of efficacy and safety with a low complication rate. In particular, excimer laser for thrombus-containing lesions is able to achi...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2013.811846

    authors: Fracassi F,Roberto M,Niccoli G

    更新日期:2013-07-01 00:00:00

  • Cochlear implants: current status and future potential.

    abstract::This article reviews the current status of cochlear implantation in both adults and children, including expanding candidacy groups, bilateral implantation, advances in speech processing software, internal and external device hardware, surgical techniques and outcomes. Promising advances, novel therapies and evolving c...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/erd.11.12

    authors: Cosetti MK,Waltzman SB

    更新日期:2011-05-01 00:00:00

  • Perioperative monitoring of fluid responsiveness after esophageal surgery using stroke volume variation.

    abstract:OBJECTIVE:To assess the utility of a new arterial pressure-based cardiac output (FloTrac) and central venous oximetry (PreSep) monitoring system in the perioperative management of patients undergoing radical esophagectomy. CASE SERIES:From May 2006, a new analyzing device (Vigileo monitor; Edwards Lifesciences LLC, To...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章

    doi:10.1586/17434440.5.3.311

    authors: Kobayashi M,Ko M,Kimura T,Meguro E,Hayakawa Y,Irinoda T,Takagane A

    更新日期:2008-05-01 00:00:00

  • Performance of a new device for the clinical determination of light discomfort.

    abstract:PURPOSE:To assess the performance of a new device for the clinical determination of light discomfort on a large sample of healthy human subjects. METHODS:A total of 489 subjects ranging from 20 to 70 years old (241 men, 248 women) were evaluated with the LUMIZ™ 100 to determine light discomfort. Repeatability was asse...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章

    doi:10.1080/17434440.2020.1837623

    authors: Montés-Micó R,Cerviño A,Martínez-Albert N,García-Marqués JV,Marie S

    更新日期:2020-11-01 00:00:00

  • Bacteriophage biosensors for antibiotic-resistant bacteria.

    abstract::An increasing number of disease-causing bacteria are resistant to one or more anti-bacterial drugs utilized for therapy. Early and speedy detection of these pathogens is therefore very important. Traditional pathogen detection techniques, that include microbiological and biochemical assays are long and labor-intensive...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2014.882767

    authors: Sorokulova I,Olsen E,Vodyanoy V

    更新日期:2014-03-01 00:00:00

  • Non-invasive assessment of gestational hemodynamics: benefits and limitations of impedance cardiography versus other techniques.

    abstract::To obtain data for maternal stroke volume and cardiac output during pregnancy, it is preferable to use a non-invasive, accurate and reproducible method. In this aspect, impedance cardiography is an excellent technique which is also highly accessible and easy to perform. This paper is a comprehensive review on the publ...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2013.853466

    authors: Staelens A,Tomsin K,Grieten L,Oben J,Mesens T,Spaanderman M,Jacquemyn Y,Gyselaers W

    更新日期:2013-11-01 00:00:00

  • Infections of electrophysiologic cardiac devices.

    abstract::Infections related to electrophysiologic cardiac device placement are increasing dramatically and are associated with adverse outcomes. With the US population aging and living longer, cardiac devices are utilized in an older population with significant comorbidities, making the threat from infectious complications sig...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.5.2.183

    authors: Uslan DZ

    更新日期:2008-03-01 00:00:00

  • Female sterilization.

    abstract::There has been considerable development and implementation of new contraceptive methods over the last 15 years. However, sterilization has remained the most widely used method around the world. Ideally, the procedure should be safe, have a high efficacy, be readily accessible, and be personally and culturally acceptab...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.5.4.525

    authors: Chapman L,Magos A

    更新日期:2008-07-01 00:00:00

  • Radiofrequency identification and medical devices: the regulatory framework on electromagnetic compatibility. Part II: active implantable medical devices.

    abstract::The number and the types of electromagnetic emitters to which patients with active implantable medical devices (AIMD) are exposed to in their daily activities have proliferated over the last decade. Radiofrequency identification (RFID) is an example of wireless technology applied in many fields. The interaction betwee...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/erd.12.5

    authors: Mattei E,Censi F,Triventi M,Bartolini P,Calcagnini G

    更新日期:2012-05-01 00:00:00

  • Catheter directed interventions for pulmonary embolism: current status and future prospects.

    abstract::Introduction: Catheter directed interventions (CDIs) have evolved over the past decade in an attempt to reduce the complications of systemic thrombolysis, while providing equivalent therapeutic benefits.Areas covered: CDIs include a wide array of catheters that incorporate ultrasound technology, the infusion of thromb...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2020.1714432

    authors: Abou Ali AN,Saadeddin Z,Chaer RA,Avgerinos ED

    更新日期:2020-02-01 00:00:00

  • Mechanical circulatory support devices: methods to optimize hemodynamics during use.

    abstract:INTRODUCTION:Mechanical circulatory support (MCS) is an increasingly utilized mode of therapy in the management of advanced heart failure, both as bridge to heart transplantation and destination therapy. As MCS becomes more prevalent, it is ever more important to understand the complex hemodynamics of these devices, as...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2017.1324292

    authors: Chung BB,Sayer G,Uriel N

    更新日期:2017-05-01 00:00:00

  • Robotic navigation during spine surgery.

    abstract::Introduction: Potential complications associated with screw malposition may result in neurological deficits or vascular injuries. Spine surgery has significantly developed under the assistance of technological progress. The advantages of applying robotic technology in spine surgery include the possibility of improving...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2020.1699405

    authors: Zhang Q,Han XG,Xu YF,Fan MX,Zhao JW,Liu YJ,He D,Tian W

    更新日期:2020-01-01 00:00:00

  • Amplatzer Duct Occluder device: a new technology for the closure of the moderate-to-large-sized patent ductus arteriosus.

    abstract::The Amplatzer Duct Occluder is a novel device designed to allow for the transcatheter closure of virtually all sized patent ductus arteriosuses. Prior technologies have been cumbersome and challenging to deploy with somewhat less than ideal closure rates associated with their use. This article summarizes the present k...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章

    doi:10.1586/17434440.3.3.291

    authors: Pass RH

    更新日期:2006-05-01 00:00:00

  • Improving retrieval rates for retrievable inferior vena cava filters.

    abstract::The introduction of retrievable inferior vena cava (IVC) filters was an important step in the evolution of deep vein thrombosis/pulmonary embolism management. Their removability makes them preferred to permanent filters in many cases. IVC filter retrieval often occurs at a suboptimal rate, leading to complications ass...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/erd.12.65

    authors: Dixon A,Stavropoulos SW

    更新日期:2013-01-01 00:00:00

  • The Visible Heart® project and methodologies: novel use for studying cardiac monophasic action potentials and evaluating their underlying mechanisms.

    abstract:INTRODUCTION:This review describes the utilization of Visible Heart® methodologies for electrophysiologic studies, specifically in the investigation of monophasic action potential (MAP) recordings, with the aim to facilitate new catheter/device design and development that may lead to earlier diagnosis, treatment, and u...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2018.1493922

    authors: Schmidt MM,Iaizzo PA

    更新日期:2018-07-01 00:00:00