An ultrasensitive young interferometer handheld sensor for rapid virus detection.

Abstract:

:Future viral outbreaks are a major threat to societal and economic development throughout the world. A rapid, sensitive and easy-to-use test for viral infections is essential to prevent and control such viral pandemics. Furthermore, a compact, portable device is potentially very useful in remote or developing regions without easy access to sophisticated laboratory facilities. In this report we discuss the application of a Young interferometer sensor device for ultrasensitive and real-time detection of viruses. The essential innovation in this technique is the combination of an integrated optical interferometric sensor with antibody-antigen recognition approaches to yield very sensitive, rapid virus detection. The technology is amenable to miniaturization and mass production and, thus, has significant potential to be developed into a handheld, point-of-care device.

journal_name

Expert Rev Med Devices

authors

Ymeti A,Subramaniam V,Beumer TA,Kanger JS

doi

10.1586/17434440.4.4.447

subject

Has Abstract

pub_date

2007-07-01 00:00:00

pages

447-54

issue

4

eissn

1743-4440

issn

1745-2422

journal_volume

4

pub_type

杂志文章
  • Cardiac rhythm management devices in a magnetic resonance environment.

    abstract::MRI is the gold standard diagnostic tool for soft tissue imaging for many specialties. An impressive body of research has proven the effectiveness of cardiac rhythm management devices (CRMDs) objectively, in terms of parameters that include patient's quality of life, morbidity, and mortality. However, interaction betw...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2014.882228

    authors: Fanourgiakis J,Kanoupakis E

    更新日期:2014-03-01 00:00:00

  • From portable dialysis to a bioengineered kidney.

    abstract:INTRODUCTION:Since the advent of peritoneal dialysis (PD) in the 1970s, the principles of dialysis have changed little. In the coming decades, several major breakthroughs are expected. AREAS COVERED:Novel wearable and portable dialysis devices for both hemodialysis (HD) and PD are expected first. The HD devices could ...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2018.1462697

    authors: van Gelder MK,Mihaila SM,Jansen J,Wester M,Verhaar MC,Joles JA,Stamatialis D,Masereeuw R,Gerritsen KGF

    更新日期:2018-05-01 00:00:00

  • Intraoperative storage of saphenous vein grafts in coronary artery bypass grafting.

    abstract::Background: Saline is not biocompatible with saphenous vein grafts and does not protect against ischemia reperfusion injury. We compared normal heparinized saline with DuraGraft, a new graft-storage solution, in in-vitro and ex-vivo assays to evaluate the effects on cells and vascular graft tissue.Methods: Human saphe...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章

    doi:10.1080/17434440.2019.1682996

    authors: Pachuk CJ,Rushton-Smith SK,Emmert MY

    更新日期:2019-11-01 00:00:00

  • Robotics in invasive cardiac electrophysiology.

    abstract::Robotic systems allow for mapping and ablation of different arrhythmia substrates replacing hand maneuvering of intracardiac catheters with machine steering. Currently there are four commercially available robotic systems. Niobe magnetic navigation system (Stereotaxis Inc., St Louis, MO) and Sensei robotic navigation ...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2014.916207

    authors: Shurrab M,Schilling R,Gang E,Khan EM,Crystal E

    更新日期:2014-07-01 00:00:00

  • Holmium:YAG laser system for transmyocardial revascularization.

    abstract::Transmyocardial revascularization, using the US FDA-approved holmium: yttrium-aluminum-garnet (Ho:YAG) laser system, is a surgical option for patients with debilitating angina caused by diffuse coronary artery disease in areas of the heart not amenable to complete revascularization using conventional treatments. Incre...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章

    doi:10.1586/17434440.3.2.137

    authors: Allen KB

    更新日期:2006-03-01 00:00:00

  • Evaluation of Surefire's precision direct-to-tumor embolization device to augment therapeutic response to intra-arterial, liver-directed therapies for patients with primary and secondary liver cancers.

    abstract::Patients with primary and secondary liver cancers generally have a poor prognosis with limited potentially curative options. Liver-directed, intra-arterial therapies such as selective internal radiotherapy (SIRT) and trans-arterial chemoembolization (TACE) are taking a larger role in the management of these patients. ...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章

    doi:10.1586/17434440.2016.1164594

    authors: Kim AY,Miller A

    更新日期:2016-05-01 00:00:00

  • Robot-assisted total hip arthroplasty.

    abstract::Precise and accurate biomechanical reconstruction during total hip arthroplasty (THA) is essential for durable long-term survivorship. Accurate fit of cementless hip implants is also crucial to reduce micromotion between the bone-implant interfaces to allow for stable osseointegration. Robotic technology aims to minim...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2016.1124018

    authors: Banerjee S,Cherian JJ,Elmallah RK,Pierce TP,Jauregui JJ,Mont MA

    更新日期:2016-01-01 00:00:00

  • Currently available metacarpophalangeal prostheses: their designs and prospective considerations.

    abstract::Although implanted for over 40 years, finger prostheses have failed to match the success achieved by artificial hip and knee prostheses, despite a myriad of designs having been proposed and implanted. This article looks at the currently available designs of metacarpophalangeal prosthesis, both single-piece and multico...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.1.2.193

    authors: Joyce TJ

    更新日期:2004-11-01 00:00:00

  • Advanced methods of spinal stimulation in the treatment of chronic pain: pulse trains, waveforms, frequencies, targets, and feedback loops.

    abstract:INTRODUCTION:Spinal cord stimulation has emerged as a state-of-the-art evidence-based treatment for chronic neuropathic pain and mixed nociceptive-neuropathic pain. In recent years, several newer devices and treatment algorithms have provided unique and effective ways of treating chronic pain by spinal cord stimulation...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2019.1567325

    authors: Maheshwari A,Pope JE,Deer TR,Falowski S

    更新日期:2019-02-01 00:00:00

  • The RNS System: responsive cortical stimulation for the treatment of refractory partial epilepsy.

    abstract::The RNS(®) System is the first commercially available device to provide closed-loop responsive brain stimulation. The system includes a cranially implanted neurostimulator that continually monitors the electrocorticogram through one or two depth and/or subdural cortical strip leads that are placed at the seizure focus...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2014.947274

    authors: Sun FT,Morrell MJ

    更新日期:2014-11-01 00:00:00

  • Evolution of endovascular stroke therapies and devices.

    abstract::Acute ischemic stroke is caused by occlusion of a cerebral artery, resulting in loss of brain tissue and neurologic deficits. However, a portion of the ischemic brain can be salvaged if blood flow is restored within an appropriate time frame. The past year has seen the publication of five positive randomized controlle...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2016.1143772

    authors: Wallace AN,Kansagra AP,McEachern J,Moran CJ,Cross DT 3rd,Derdeyn CP

    更新日期:2016-01-01 00:00:00

  • Treating bladder-outflow obstruction with thermo-expandable prostate metal stents.

    abstract::Bladder-outflow obstruction is a common age-related clinical entity due to a variety of benign and malignant diseases of the prostate. Surgical treatment is not suitable for high-risk elderly patients who seek minimally invasive management. We present a prostatic thermo-expandable metal stent for treating bladder-outf...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/erd.09.13

    authors: Papatsoris AG,El-Husseiny T,Sawada Y,Takahashi T,Nagaoka A,Maan Z,Moraitis K,Masood J,Junaid I,Buchholz N

    更新日期:2009-07-01 00:00:00

  • Clinical role of fluorescence imaging in colorectal surgery - a review.

    abstract:INTRODUCTION:Anastomotic leak (AL) after colorectal surgery is a devastating complication; decreased blood perfusion is an important risk factor. Surgeons rely on subjective measures to assess bowel perfusion. Fluorescence imaging (FI) with indocyanine green (ICG) provides a real-time objective assessment of intestinal...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,meta分析,评审

    doi:10.1080/17434440.2017.1265444

    authors: Mizrahi I,Wexner SD

    更新日期:2017-01-01 00:00:00

  • Endoscopic stenting for palliation of malignant biliary obstruction.

    abstract::Malignant biliary obstruction results in jaundice, often with symptoms that decrease the quality of life. Biliary stent placement has largely supplanted surgical bypass for palliation of malignant biliary obstruction. Traditional rigid plastic stents are commonly used, inexpensive and easily removed, although with lim...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/erd.10.36

    authors: Ferreira LE,Baron TH

    更新日期:2010-09-01 00:00:00

  • Right heart transcatheter valve therapies - a review of prostheses for the pulmonary and tricuspid positions.

    abstract::Minimally invasive, catheter-based treatment of valvular dysfunction has become an integral part of clinical routine. As left heart valvular disease is much more common and thus commercially of interest, transcatheter solutions for the treatment of aortic and mitral valvular defects were the first to become broadly cl...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2015.985654

    authors: Kuetting M,Pott D,Sedaghat A,Ng YA,Egron S,Rosefort C,Werner N,Sachweh J,Steinseifer U

    更新日期:2015-03-01 00:00:00

  • Cellular magnetic resonance imaging: current status and future prospects.

    abstract::Cellular magnetic resonance imaging (CMRI) allows for the tracking of the temporal and spatial migration of cells labeled with MR contrast agents within organs and tissues. This rapidly growing area of experimental research has the potential of translating from bench to bedside and may be used in conjunction with cell...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.3.4.427

    authors: Arbab AS,Liu W,Frank JA

    更新日期:2006-07-01 00:00:00

  • Top 100 cited noninvasive neuromodulation clinical trials.

    abstract:INTRODUCTION:Introduction: Transcranial direct current stimulation (tDCS) and transcranial magnetic stimulation (TMS) are noninvasive neuromodulation techniques used as therapeutic and research tools for several neuropsychiatric conditions. Given the exponential scientific growth of this field, we aimed to systematical...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2019.1615440

    authors: Lucena MFG,Teixeira PEP,Bonin Pinto C,Fregni F

    更新日期:2019-06-01 00:00:00

  • Mechanical adjuncts for cardiocerebral resuscitation.

    abstract::Introduction: Cardiac arrest remains a worldwide health problem with very poor outcome. In the absence of bystander resuscitation, survival rates decrease by 10% per minute of arrest and global ischemia. Even the best manual chest compressions, however, can only produce a fraction of normal cardiac output and blood fl...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2019.1649135

    authors: Riess ML,Balzer C

    更新日期:2019-09-01 00:00:00

  • Carotid angioplasty and stenting under protection: advantages and drawbacks.

    abstract::Carotid stenosis is responsible for approximately 30% of strokes, and carotid endarterectomy is considered to be the gold-standard treatment. Carotid angioplasty and stenting (CAS) has been proposed as an alternative to surgery but the risk of neurological complications and brain embolism remains the major drawback to...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.5.5.591

    authors: Henry M,Polydorou A,Henry I,Polydorou AD,Hugel M

    更新日期:2008-09-01 00:00:00

  • COVID-19: ensuring our medical equipment can meet the challenge.

    abstract::To predict the spread of coronavirus disease globally and consequently prepare the hospital facilities with the required technology is a challenge. The availability of essential medical equipment to support patients affected by Covid-19 is globally limited. Areas covered This perspective gives a technical view of the ...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2020.1772757

    authors: Garzotto F,Ceresola E,Panagiotakopoulou S,Spina G,Menotto F,Benozzi M,Casarotto M,Lanera C,Bonavina MG,Gregori D,Meneghesso G,Opocher G

    更新日期:2020-06-01 00:00:00

  • A review of thermal methods and technologies for diabetic foot assessment.

    abstract::Temperature analysis has been considered as a complementary method in medical evaluation and diagnosis. Several studies demonstrated that monitoring the temperature variations of the feet of diabetic patients can be helpful in the early identification of diabetic foot manifestations, and also in changing behaviors, wh...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2015.1032251

    authors: Sousa P,Felizardo V,Oliveira D,Couto R,Garcia NM

    更新日期:2015-07-01 00:00:00

  • A robot for transnasal surgery featuring needle-sized tentacle-like arms.

    abstract::This paper discusses a new class of robots known as concentric tube robots and their application to transnasal skull base surgery. The endonasal approach has clear benefits for patients, but the surgery presents challenges that strongly motivate the use of robotic tools. In this paper, the concentric tube robot concep...

    journal_title:Expert review of medical devices

    pub_type: 社论

    doi:10.1586/17434440.2013.854702

    authors: Gilbert H,Hendrick R,Remirez A,Webster R 3rd

    更新日期:2014-01-01 00:00:00

  • Advances in temporary mechanical support for treatment of cardiogenic shock.

    abstract::Mechanical circulatory support devices are the mainstay of treatment for severe cardiogenic shock refractory to pharmacologic therapy. Their evolution over the past few decades has been remarkable with a common theme of developing reliable, less bulky and more easily percutaneously implantable devices. The goal of thi...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2015.1086265

    authors: Koprivanac M,Kelava M,Soltesz E,Smedira N,Kapadia S,Brzezinski A,Alansari S,Moazami N

    更新日期:2015-01-01 00:00:00

  • Continuous-flow left ventricular assist device implantation in patients with preexisting mechanical mitral valves: a systematic review.

    abstract::Introduction: A preexisting mechanical mitral valve (MMV) is thought to be a thrombogenic risk factor after continuous-flow left ventricular assist device (CF-LVAD) implantation. We sought to evaluate the management and outcomes of preexisting MMVs in patients following CF-LVAD implantation.Areas covered: An electroni...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章

    doi:10.1080/17434440.2020.1754190

    authors: Gordon JS,O'Malley TJ,Maynes EJ,Wood CT,Kalantri N,Morris RJ,Samuels LE,Massey HT,Tchantchaleishvili V

    更新日期:2020-05-01 00:00:00

  • Stent placement for esophageal strictures: an update.

    abstract::The use of stents for esophageal strictures has evolved rapidly over the past 10 years, from rigid plastic tubes to flexible self-expanding metal (SEMS), plastic (SEPS) and biodegradable stents. For the palliative treatment of malignant dysphagia both SEMS and SEPS effectively provide a rapid relief of dysphagia. SEMS...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/erd.11.44

    authors: Hirdes MM,Vleggaar FP,Siersema PD

    更新日期:2011-11-01 00:00:00

  • Non-invasive imaging techniques to assess myocardial perfusion.

    abstract:INTRODUCTION:Coronary artery disease affecting myocardial perfusion continues to be the leading cause of cardiovascular morbidity and mortality worldwide. While invasive evaluation based on coronary angiography and flow measurements still is considered the reference technique for assessing myocardial perfusion, technol...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2020.1834844

    authors: Villemain O,Baranger J,Jalal Z,Lam C,Calais J,Pernot M,Cifra B,Friedberg MK,Mertens L

    更新日期:2020-11-01 00:00:00

  • Device profile of the MobiusHD EVBA system for the treatment of resistant hypertension: overview of its mechanism of action, safety and efficacy.

    abstract:INTRODUCTION:Early promising results of renal nerve denervation awakened interest in developing medical device alternatives for patients with resistant hypertension. The subsequent sham-controlled renal nerve denervation randomized trials were disappointing leading researchers and innovators to explore alternative devi...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2020.1779054

    authors: Bates MC,Stone GW,Chen CY,Spiering W

    更新日期:2020-07-01 00:00:00

  • Neuroinformatics and modeling of the basal ganglia: bridging pharmacology and physiology.

    abstract::The subthalamic nucleus (STN) is the primary target for the chronic deep brain stimulation treatment of Parkinson's disease. STN neurons exhibit a variety of characteristic properties that may play a key role in the overall population response to deep brain stimulation. Neuroinformatics techniques, in particular compu...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.4.5.663

    authors: Gillies A,Willshaw D

    更新日期:2007-09-01 00:00:00

  • New developments in ureteral stent design, materials and coatings.

    abstract::Ureteral stents are used in a variety of urological diseases and procedures. The majority of patients with indwelling ureteral stents experience bothersome symptoms and are at increased risk for urinary tract infection. Stent encrustation and the associated complications can also result in significant patient morbidit...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.3.3.395

    authors: Chew BH,Duvdevani M,Denstedt JD

    更新日期:2006-05-01 00:00:00

  • Safe incorporation of new technologies in thyroid surgery.

    abstract::The history of thyroid surgery starts with Billroth, Kocher and Halsted, who developed the technique for thyroidectomy between the years of 1873 and 1910. In general the essential objectives for thyroidectomy are: sparing the parathyroid glands, avoidance of injury to the laryngeal nerves, an accurate hemostasis and a...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.5.6.747

    authors: Dionigi G,Bacuzzi A,Bertocchi V,Carrafiello G,Boni L,Rovera F,Dionigi R

    更新日期:2008-11-01 00:00:00