Cardiac rhythm management devices in a magnetic resonance environment.

Abstract:

:MRI is the gold standard diagnostic tool for soft tissue imaging for many specialties. An impressive body of research has proven the effectiveness of cardiac rhythm management devices (CRMDs) objectively, in terms of parameters that include patient's quality of life, morbidity, and mortality. However, interaction between CRMDs and MRI scanners is a problem. Static main magnetic field, radiofrequency energy and the gradient magnetic field are three distinct mechanisms related to MRI and cause risks to CRMDs. Very often, patients with CRMDs have been excluded from undergoing MRI scans despite the fact that these scans were critical for the diagnosis and therapy of patients with serious medical conditions. In order for all patients with CRMDs to have the ability to perform this exam, the industry works hard to design devices that are MRI conditional.

journal_name

Expert Rev Med Devices

authors

Fanourgiakis J,Kanoupakis E

doi

10.1586/17434440.2014.882228

subject

Has Abstract

pub_date

2014-03-01 00:00:00

pages

199-203

issue

2

eissn

1743-4440

issn

1745-2422

journal_volume

11

pub_type

杂志文章,评审
  • Endoscopy-guided vitreoretinal surgery.

    abstract::Vitreoretinal surgery has recently undergone remarkable developments. The introduction of micro-incision vitrectomy surgery using 25- and 23-gauge techniques has led to minimally invasive, faster, safer, and more accurate surgeries. Similarly, intraocular illumination and observation systems have advanced from light p...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2014.882226

    authors: Kawashima S,Kawashima M,Tsubota K

    更新日期:2014-03-01 00:00:00

  • New autoinjector technology for the delivery of subcutaneous methotrexate in the treatment of rheumatoid arthritis.

    abstract::Methotrexate (MTX) is the cornerstone of treatment for rheumatoid arthritis (RA), and is widely used both as first-line therapy and as an important component of long-term therapy. Although subcutaneous MTX is typically delivered orally, parenteral administration offers benefits with respect to tolerability and systemi...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2014.929492

    authors: Schiff M,Jaffe J,Freundlich B,Madsen P

    更新日期:2014-09-01 00:00:00

  • Robotic navigation during spine surgery.

    abstract::Introduction: Potential complications associated with screw malposition may result in neurological deficits or vascular injuries. Spine surgery has significantly developed under the assistance of technological progress. The advantages of applying robotic technology in spine surgery include the possibility of improving...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2020.1699405

    authors: Zhang Q,Han XG,Xu YF,Fan MX,Zhao JW,Liu YJ,He D,Tian W

    更新日期:2020-01-01 00:00:00

  • Cardima Surgical Ablation System: a novel tool for cardiac ablation in the treatment of atrial fibrillation.

    abstract::Atrial fibrillation is a pervasive and difficult heart rhythm problem for more than 3 million Americans. Patients are plagued by myriad symptoms and are exposed to the risk of stroke. Attempts to restore normal rhythm with drug therapy have been largely unsuccessful and the complications associated with long-term anti...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/erd.09.9

    authors: Saltman AE

    更新日期:2009-05-01 00:00:00

  • The Lean and Agile Multi-dimensional Process (LAMP) - a new framework for rapid and iterative evidence generation to support health-care technology design and development.

    abstract::Introduction: Health technology assessments (HTA) are tools for policymaking and resource allocation. Early HTAs are increasingly used in design and development of new technologies. Conducting early HTAs is challenging, due to a lack of evidence and significant uncertainties in the technology and the market. A multi-d...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2020.1743174

    authors: Ni M,Borsci S,Walne S,Mclister AP,Buckle P,Barlow JG,Hanna GB

    更新日期:2020-04-01 00:00:00

  • Shields and garb for decreasing radiation exposure in the cath lab.

    abstract:INTRODUCTION:Decreasing radiation exposure of the cardiac catheterization laboratory staff is critical for minimizing radiation-related adverse outcomes and can be accomplished by decreasing patient dose and by shielding. Areas covered: protection from ionizing radiation can be achieved with architectural, equipment-mo...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2018.1510771

    authors: Karatasakis A,Brilakis ES

    更新日期:2018-09-01 00:00:00

  • Modeling of the medical device development process.

    abstract::Models are abstract representations of reality that are built, analyzed and manipulated to augment the understanding of that reality. They can either be mental or codified but, in both cases, they contribute to good decision-making by ensuring that the right people use the right information at the right time. In order...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/erd.12.36

    authors: Santos IC,Gazelle GS,Rocha LA,Tavares JM

    更新日期:2012-09-01 00:00:00

  • Advances in temporary mechanical support for treatment of cardiogenic shock.

    abstract::Mechanical circulatory support devices are the mainstay of treatment for severe cardiogenic shock refractory to pharmacologic therapy. Their evolution over the past few decades has been remarkable with a common theme of developing reliable, less bulky and more easily percutaneously implantable devices. The goal of thi...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2015.1086265

    authors: Koprivanac M,Kelava M,Soltesz E,Smedira N,Kapadia S,Brzezinski A,Alansari S,Moazami N

    更新日期:2015-01-01 00:00:00

  • Robotics in invasive cardiac electrophysiology.

    abstract::Robotic systems allow for mapping and ablation of different arrhythmia substrates replacing hand maneuvering of intracardiac catheters with machine steering. Currently there are four commercially available robotic systems. Niobe magnetic navigation system (Stereotaxis Inc., St Louis, MO) and Sensei robotic navigation ...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2014.916207

    authors: Shurrab M,Schilling R,Gang E,Khan EM,Crystal E

    更新日期:2014-07-01 00:00:00

  • Using medical imaging for the detection of adverse events ("incidents") during the utilization of left ventricular assist devices in adult patients with advanced heart failure.

    abstract::Ventricular assist devices (VAD) are used for mechanical support of the terminally failing heart. Failure of these life supporting systems can be fatal. Early and reliable detection of any upcoming problems is mandatory and is crucial for the outcome. Medical imaging methods are described within this review, which are...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2016.1166051

    authors: Kaufmann F,Krabatsch T

    更新日期:2016-05-01 00:00:00

  • Electrothermal bipolar vessel sealing system (LigaSure) for hemostasis during thyroid surgery: a comprehensive review.

    abstract::Conventional hemostatic technologies utilized in thyroid surgery include clamp-and-tie, clips and monopolar and bipolar diathermy. Over the last decade, there has been a major shift towards utilizing newer hemostatic technologies, most notably the electrothermal bipolar vessel sealing systems (EBVS) and the Harmonic S...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/erd.13.6

    authors: Butskiy O,Wiseman SM

    更新日期:2013-05-01 00:00:00

  • The role of active middle-ear implants in the rehabilitation of hearing loss.

    abstract::The surgical implantation of auditory devices to improve or restore the sensation of hearing in affected individuals is a rapidly growing area of modern ear, nose and throat, and audiological practice. Following the enormous success of cochlear implantation and set to take an increasing role in the rehabilitation of d...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/erd.11.18

    authors: Green K

    更新日期:2011-07-01 00:00:00

  • Treating bladder-outflow obstruction with thermo-expandable prostate metal stents.

    abstract::Bladder-outflow obstruction is a common age-related clinical entity due to a variety of benign and malignant diseases of the prostate. Surgical treatment is not suitable for high-risk elderly patients who seek minimally invasive management. We present a prostatic thermo-expandable metal stent for treating bladder-outf...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/erd.09.13

    authors: Papatsoris AG,El-Husseiny T,Sawada Y,Takahashi T,Nagaoka A,Maan Z,Moraitis K,Masood J,Junaid I,Buchholz N

    更新日期:2009-07-01 00:00:00

  • Transcatheter aortic valve implantation: long-term clinical outcome and valve durability.

    abstract::Transcatheter aortic valve implantation (TAVI) is a widely used intervention in patients who are at high risk or contraindicated for cardiac surgery. The procedure is technically feasible in most patients and has very good mid-term clinical outcomes. In this special report, we evaluated the long-term outcome after TAV...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章

    doi:10.1586/17434440.2015.1063994

    authors: Sulzenko J,Tousek P,Kocka V,Widimsky P

    更新日期:2015-01-01 00:00:00

  • The Reveal LINQ insertable cardiac monitor.

    abstract::Insertable cardiac monitors (ICMs) are leadless subcutaneous devices that continuously monitor the heart rhythm and record events over a timeframe measured in years, allowing for the diagnosis of infrequent rhythm abnormalities that can be the cause of palpitations, syncope and stroke. To date, ICMs have primarily bee...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2014.953059

    authors: Tomson TT,Passman R

    更新日期:2015-01-01 00:00:00

  • Systematic review of various laser intervention strategies for proliferative diabetic retinopathy.

    abstract::Diabetic retinopathy (DR) is a common complication of diabetes. DR obstructs blood supply to the retina and has serious and long-lasting detrimental effects on quality of life. Panretinal photocoagulation, a laser surgical intervention, is advocated for early treatment of DR to prevent visual loss; however, results fr...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2014.953057

    authors: Luo D,Zheng Z,Xu X,Fan Y,Zhu B,Liu K,Wang F,Sun X,Zou H,Xia X

    更新日期:2015-01-01 00:00:00

  • Mechanical adjuncts for cardiocerebral resuscitation.

    abstract::Introduction: Cardiac arrest remains a worldwide health problem with very poor outcome. In the absence of bystander resuscitation, survival rates decrease by 10% per minute of arrest and global ischemia. Even the best manual chest compressions, however, can only produce a fraction of normal cardiac output and blood fl...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2019.1649135

    authors: Riess ML,Balzer C

    更新日期:2019-09-01 00:00:00

  • Potential of APDM mobility lab for the monitoring of the progression of Parkinson's disease.

    abstract::APDM's Mobility Lab system provides portable, validated, reliable, objective measures of balance and gait that are sensitive to Parkinson's disease (PD). In this review, we describe the potential of objective measures collected with the Mobility Lab system for tracking longitudinal progression of PD. Balance and gait ...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2016.1153421

    authors: Mancini M,Horak FB

    更新日期:2016-05-01 00:00:00

  • What can be done for cerebral embolic protection in TAVI? Analysis in the light of 10 years' experience with protected carotid artery stenting.

    abstract::In the last 30 years, development of minimally invasive percutaneous procedures to treat cardiovascular defects has been thriving. Although these techniques present obvious advantages, like avoiding cardiopulmonary bypass, the passage of catheter systems and the deployment of devices in the blood circulation can cause...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2015.1120666

    authors: Egron S,Kütting M,Marzelle J,Becquemin JP,Schmitz-Rode T,Steinseifer U

    更新日期:2016-01-01 00:00:00

  • New developments in ureteral stent design, materials and coatings.

    abstract::Ureteral stents are used in a variety of urological diseases and procedures. The majority of patients with indwelling ureteral stents experience bothersome symptoms and are at increased risk for urinary tract infection. Stent encrustation and the associated complications can also result in significant patient morbidit...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.3.3.395

    authors: Chew BH,Duvdevani M,Denstedt JD

    更新日期:2006-05-01 00:00:00

  • The challenges surrounding preclinical testing in transcatheter device development and the implications on the clinic.

    abstract:INTRODUCTION:Transcatheter devices have contributed significantly to the advances achieved in treating many cardiovascular conditions over the last few decades. Sophisticated and detailed preclinical testing is not only a regulatory requirement to support an investigational device exemption (IDE) application, but more ...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章

    doi:10.1080/17434440.2017.1282313

    authors: Holzer R,Goble J,Hijazi Z

    更新日期:2017-02-01 00:00:00

  • Creating a wearable artificial kidney: where are we now?

    abstract::A wearable and, ultimately, an implantable artificial kidney is a long-held aim in the treatment of patients with end-stage renal disease, provided that it would combine continuous blood purification, preventing the fluctuations in the internal environment associated with hemodialysis, while maintaining a high efficie...

    journal_title:Expert review of medical devices

    pub_type: 社论

    doi:10.1586/17434440.2015.1053466

    authors: Kooman JP,Joles JA,Gerritsen KG

    更新日期:2015-07-01 00:00:00

  • Right heart transcatheter valve therapies - a review of prostheses for the pulmonary and tricuspid positions.

    abstract::Minimally invasive, catheter-based treatment of valvular dysfunction has become an integral part of clinical routine. As left heart valvular disease is much more common and thus commercially of interest, transcatheter solutions for the treatment of aortic and mitral valvular defects were the first to become broadly cl...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2015.985654

    authors: Kuetting M,Pott D,Sedaghat A,Ng YA,Egron S,Rosefort C,Werner N,Sachweh J,Steinseifer U

    更新日期:2015-03-01 00:00:00

  • Autofluorescence imaging videobronchoscopy in the detection of lung cancer: from research tool to everyday procedure.

    abstract::Autofluorescence imaging videobronchoscopy (AFI) is one of the new systems of autofluorescence bronchoscopy designed for thorough examination of bronchial mucosa. The integration of autofluorescence and videobronchoscopy provides clear images of normal and pathologically altered bronchial mucosa. Major indications for...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章

    doi:10.1586/erd.10.92

    authors: Zaric B,Perin B,Becker HD,Herth FF,Eberhardt R,Djuric M,Djuric D,Matijasevic J,Kopitovic I,Stanic J

    更新日期:2011-03-01 00:00:00

  • Recent advances in imaging technologies for assessment of retinal diseases.

    abstract:INTRODUCTION:Retinal imaging is a key investigation in ophthalmology. New devices continue to be created to keep up with the demand for better imaging modalities in this field. This review looks to highlight current trends and the future of retinal imaging. AREAS COVERED:This review looks at the advances in topographi...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2020.1816167

    authors: Soomro T,Shah N,Niestrata-Ortiz M,Yap T,Normando EM,Cordeiro MF

    更新日期:2020-10-01 00:00:00

  • Improving retrieval rates for retrievable inferior vena cava filters.

    abstract::The introduction of retrievable inferior vena cava (IVC) filters was an important step in the evolution of deep vein thrombosis/pulmonary embolism management. Their removability makes them preferred to permanent filters in many cases. IVC filter retrieval often occurs at a suboptimal rate, leading to complications ass...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/erd.12.65

    authors: Dixon A,Stavropoulos SW

    更新日期:2013-01-01 00:00:00

  • Devices for thoracic endovascular aortic repair of type B aortic dissection: is there any chance for Marfan syndrome?

    abstract:INTRODUCTION:Type B aortic dissection (TBAD) is a threatening event that may lead to death for aortic rupture or multivisceral malperfusion in the acute phase and offers a poor prognosis for long term survivors. Thoracic endovascular aortic repair (TEVAR) has become the preferential therapy in acute and chronic complic...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2020.1782735

    authors: Lovato L,Cefarelli M,Gatta E,Di Eusanio M,Fattori R

    更新日期:2020-07-01 00:00:00

  • Consumer sleep tracking devices: a review of mechanisms, validity and utility.

    abstract::Consumer sleep tracking devices such as fitness trackers and smartphone apps have become increasingly popular. These devices claim to measure the sleep duration of their users and in some cases purport to measure sleep quality and awaken users from light sleep, potentially improving overall sleep. Most of these device...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2016.1171708

    authors: Kolla BP,Mansukhani S,Mansukhani MP

    更新日期:2016-05-01 00:00:00

  • Bicomponent electrospun scaffolds to design extracellular matrix tissue analogs.

    abstract::In the last decade, bicomponent fibers have been proposed to fabricate bio-inspired systems for tissue repair, regenerative medicine, medical healthcare and clinical applications. In comparison with monocomponent fibers, key advantage concerns their ability of self-adapting to the physiological conditions through an e...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2016.1126505

    authors: Guarino V,Cirillo V,Ambrosio L

    更新日期:2016-01-01 00:00:00

  • Percutaneous laser ablation of cervical metastatic lymph nodes in papillary thyroid carcinoma: clinical efficacy and anatomical considerations.

    abstract::Background: Papillary thyroid carcinoma is the most common type of thyroid cancer; despite its generally indolent course, patients often develop local post-operative recurrences. Re-operation, however, holds a high complication rate, while at the same time, not all patients benefit from radioiodine ablation. This syst...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章

    doi:10.1080/17434440.2021.1864323

    authors: Spartalis E,Karagiannis SP,Plakopitis N,Theodori MA,Athanasiadis DI,Schizas D,Spartalis M,Troupis T

    更新日期:2020-12-29 00:00:00