The Visible Heart® project and methodologies: novel use for studying cardiac monophasic action potentials and evaluating their underlying mechanisms.

Abstract:

INTRODUCTION:This review describes the utilization of Visible Heart® methodologies for electrophysiologic studies, specifically in the investigation of monophasic action potential (MAP) recordings, with the aim to facilitate new catheter/device design and development that may lead to earlier diagnosis, treatment, and ultimately a higher quality of life for patients with atrial fibrillation. AREAS COVERED:We describe the historically proposed mechanisms behind which electrode is responsible for the MAP recording, new catheters for recording these signals, and how Visible Heart methodologies can be utilized to develop and test new technologies for electrophysiologic investigations. EXPERT OPINION:When compared to traditional electrogram recordings, MAP waveforms provide clinical information vital to the understanding, diagnosis, and treatment of cardiac arrhythmias. New catheters and ablation technologies are routinely being assessed on reanimated large mammalian hearts (swine and human) in our laboratory. These abilities, combined with continued enhancements in imaging modalities and computational systems for electrical mapping, are being applied to the MAP catheter design process. Through this testing we are hopeful that the time from concept to product can be reduced, and that an array of MAP catheters can be placed in the hands of physicians, where they will improve patient outcomes.

journal_name

Expert Rev Med Devices

authors

Schmidt MM,Iaizzo PA

doi

10.1080/17434440.2018.1493922

subject

Has Abstract

pub_date

2018-07-01 00:00:00

pages

467-477

issue

7

eissn

1743-4440

issn

1745-2422

journal_volume

15

pub_type

杂志文章,评审
  • Improving retrieval rates for retrievable inferior vena cava filters.

    abstract::The introduction of retrievable inferior vena cava (IVC) filters was an important step in the evolution of deep vein thrombosis/pulmonary embolism management. Their removability makes them preferred to permanent filters in many cases. IVC filter retrieval often occurs at a suboptimal rate, leading to complications ass...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/erd.12.65

    authors: Dixon A,Stavropoulos SW

    更新日期:2013-01-01 00:00:00

  • Does CircuLite Synergy assist device as partial ventricular support have a place in modern management of advanced heart failure?

    abstract::The discrepancy between the number of patients on the waiting list and available donor hearts has led to the successful development of left ventricular assist devices (LVAD) as a bridge to transplantation. The conventional LVADs are designed to provide full hemodynamic support for the end-stage failing heart. However,...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2015.985208

    authors: Mohite PN,Sabashnikov A,Simon AR,Weymann A,Patil NP,Unsoeld B,Bireta C,Popov AF

    更新日期:2015-01-01 00:00:00

  • Evaluation of Surefire's precision direct-to-tumor embolization device to augment therapeutic response to intra-arterial, liver-directed therapies for patients with primary and secondary liver cancers.

    abstract::Patients with primary and secondary liver cancers generally have a poor prognosis with limited potentially curative options. Liver-directed, intra-arterial therapies such as selective internal radiotherapy (SIRT) and trans-arterial chemoembolization (TACE) are taking a larger role in the management of these patients. ...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章

    doi:10.1586/17434440.2016.1164594

    authors: Kim AY,Miller A

    更新日期:2016-05-01 00:00:00

  • Infections of electrophysiologic cardiac devices.

    abstract::Infections related to electrophysiologic cardiac device placement are increasing dramatically and are associated with adverse outcomes. With the US population aging and living longer, cardiac devices are utilized in an older population with significant comorbidities, making the threat from infectious complications sig...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.5.2.183

    authors: Uslan DZ

    更新日期:2008-03-01 00:00:00

  • Diagnosis of small-bowel diseases in the era of capsule endoscopy.

    abstract::Capsule endoscopy is a major breakthrough in gastrointestinal endoscopy and is a first-line tool to detect abnormalities of the small bowel, in up to 50% of patients, intestinal disorders are not associated with any physical findings or positive tests. Indications, yield and impact on patient management of this method...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2.5.587

    authors: Pennazio M

    更新日期:2005-09-01 00:00:00

  • Insertable cardiac monitors: current indications and devices.

    abstract:INTRODUCTION:Recurrent unexplained syncope is a well-established indication for an insertable cardiac monitor (ICM). Recently, the indications for an ICM have been expanded. AREAS COVERED:This review article discusses the current indications for ICMs and gives an overview of the latest generation of commercially avail...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2018.1557046

    authors: Sakhi R,Theuns DAMJ,Szili-Torok T,Yap SC

    更新日期:2019-01-01 00:00:00

  • Recent advances in imaging technologies for assessment of retinal diseases.

    abstract:INTRODUCTION:Retinal imaging is a key investigation in ophthalmology. New devices continue to be created to keep up with the demand for better imaging modalities in this field. This review looks to highlight current trends and the future of retinal imaging. AREAS COVERED:This review looks at the advances in topographi...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2020.1816167

    authors: Soomro T,Shah N,Niestrata-Ortiz M,Yap T,Normando EM,Cordeiro MF

    更新日期:2020-10-01 00:00:00

  • Wearable inertial sensors for human movement analysis.

    abstract:INTRODUCTION:The present review aims to provide an overview of the most common uses of wearable inertial sensors in the field of clinical human movement analysis. AREAS COVERED:Six main areas of application are analysed: gait analysis, stabilometry, instrumented clinical tests, upper body mobility assessment, daily-li...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2016.1198694

    authors: Iosa M,Picerno P,Paolucci S,Morone G

    更新日期:2016-07-01 00:00:00

  • Cardiac rhythm management devices in a magnetic resonance environment.

    abstract::MRI is the gold standard diagnostic tool for soft tissue imaging for many specialties. An impressive body of research has proven the effectiveness of cardiac rhythm management devices (CRMDs) objectively, in terms of parameters that include patient's quality of life, morbidity, and mortality. However, interaction betw...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2014.882228

    authors: Fanourgiakis J,Kanoupakis E

    更新日期:2014-03-01 00:00:00

  • Evaluation of Pipeline Flex delivery system for the treatment of unruptured aneurysms.

    abstract:INTRODUCTION:Refinements in endovascular technology have revolutionized the treatment of intracranial aneurysms (IAs) with the development of flow-diversion technology. The first generation of the Pipelin Embolization Device (PED) has demonstrated its safety and efficacy. However, the deployment technique was a difficu...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章

    doi:10.1080/17434440.2016.1231573

    authors: Aguilar-Salinas P,Brasiliense LB,Gonsales D,Mitchell B,Lima A,Sauvageau E,Hanel R

    更新日期:2016-10-01 00:00:00

  • Current and future developments in artificial muscles using electroactive polymers.

    abstract::For decades, electroactive polymers received relatively little attention due to their limited actuation capability. However, in the last 15 years, a series of electroactive polymer materials have emerged that produce a significant shape or size change in response to electrical stimulation. These materials have the clo...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2.6.731

    authors: Bar-Cohen Y

    更新日期:2005-11-01 00:00:00

  • Driving restriction in patients with cardiac implantable electronic devices: an overview of worldwide regulations.

    abstract::Introduction: It is common belief that driving with an implantable cardioverter defibrillator (ICD)/pacemaker (PM) might be associated with sudden cardiac incapacitation, road traffic accidents, and chance to harm to self and others. On the other hand, the ability to drive is highly valuable in the modern era, represe...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2020.1742108

    authors: Imberti JF,Vitolo M,Proietti M,Diemberger I,Ziacchi M,Biffi M,Boriani G

    更新日期:2020-04-01 00:00:00

  • Stent placement for esophageal strictures: an update.

    abstract::The use of stents for esophageal strictures has evolved rapidly over the past 10 years, from rigid plastic tubes to flexible self-expanding metal (SEMS), plastic (SEPS) and biodegradable stents. For the palliative treatment of malignant dysphagia both SEMS and SEPS effectively provide a rapid relief of dysphagia. SEMS...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/erd.11.44

    authors: Hirdes MM,Vleggaar FP,Siersema PD

    更新日期:2011-11-01 00:00:00

  • Robot-assisted total hip arthroplasty.

    abstract::Precise and accurate biomechanical reconstruction during total hip arthroplasty (THA) is essential for durable long-term survivorship. Accurate fit of cementless hip implants is also crucial to reduce micromotion between the bone-implant interfaces to allow for stable osseointegration. Robotic technology aims to minim...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2016.1124018

    authors: Banerjee S,Cherian JJ,Elmallah RK,Pierce TP,Jauregui JJ,Mont MA

    更新日期:2016-01-01 00:00:00

  • Imaging techniques in pancreatic tumors.

    abstract::Conventional ultrasonography represents the first diagnostic imaging modality for the study of pancreatic tumors. Contrast-enhanced ultrasound has significantly improved the accuracy of first-line examination and may influence the choice of second-line investigations: multidetector computed tomography is considered th...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/erd.09.67

    authors: D'Onofrio M,Gallotti A,Pozzi Mucelli R

    更新日期:2010-03-01 00:00:00

  • Top 100 cited noninvasive neuromodulation clinical trials.

    abstract:INTRODUCTION:Introduction: Transcranial direct current stimulation (tDCS) and transcranial magnetic stimulation (TMS) are noninvasive neuromodulation techniques used as therapeutic and research tools for several neuropsychiatric conditions. Given the exponential scientific growth of this field, we aimed to systematical...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2019.1615440

    authors: Lucena MFG,Teixeira PEP,Bonin Pinto C,Fregni F

    更新日期:2019-06-01 00:00:00

  • Is there an alternative to systemic anticoagulation, as related to interventional biomedical devices?

    abstract::To reduce the toxic effects, related clinical problems and complications such as bleeding disorders associated with systemic anticoagulation, it has been hypothesized that by coating the surfaces of medical devices, such as stents, bypass grafts, extracorporeal circuits, guide wires and catheters, there will be a sign...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章

    doi:10.1586/17434440.3.2.245

    authors: Conn G,Kidane AG,Punshon G,Kannan RY,Hamilton G,Seifalian AM

    更新日期:2006-03-01 00:00:00

  • Abdominal wall reconstruction using biological tissue grafts: present status and future opportunities.

    abstract::Surgeons often encounter the challenge of treating acquired abdominal wall defects following abdominal surgery. The current standard of practice is to repair most defects using permanent synthetic mesh material. Mesh augments the strength of the weakened abdominal wall fascia and enables the hernia repair to be perfor...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.3.5.657

    authors: Bellows CF,Alder A,Helton WS

    更新日期:2006-09-01 00:00:00

  • Endoscopic stenting for palliation of malignant biliary obstruction.

    abstract::Malignant biliary obstruction results in jaundice, often with symptoms that decrease the quality of life. Biliary stent placement has largely supplanted surgical bypass for palliation of malignant biliary obstruction. Traditional rigid plastic stents are commonly used, inexpensive and easily removed, although with lim...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/erd.10.36

    authors: Ferreira LE,Baron TH

    更新日期:2010-09-01 00:00:00

  • Perioperative monitoring of fluid responsiveness after esophageal surgery using stroke volume variation.

    abstract:OBJECTIVE:To assess the utility of a new arterial pressure-based cardiac output (FloTrac) and central venous oximetry (PreSep) monitoring system in the perioperative management of patients undergoing radical esophagectomy. CASE SERIES:From May 2006, a new analyzing device (Vigileo monitor; Edwards Lifesciences LLC, To...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章

    doi:10.1586/17434440.5.3.311

    authors: Kobayashi M,Ko M,Kimura T,Meguro E,Hayakawa Y,Irinoda T,Takagane A

    更新日期:2008-05-01 00:00:00

  • Evolution of precise and multimodal MRI and TRUS in detection and management of early prostate cancer.

    abstract::The combination of T2-weighted MRI with functional MRI, including contrast-enhanced MRI, diffusion-weighted imaging and magnetic resonance spectroscopy, has been recognized as the most promising diagnostic modality for the detection and staging of localized prostate cancer. In spite of the relatively low predictive va...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/erd.10.24

    authors: Ukimura O

    更新日期:2010-07-01 00:00:00

  • Remote-controlled internal lengthening plate for distraction osteogenesis in pediatric patients.

    abstract:OBJECTIVES:Limb lengthening by distraction osteogenesis is a technique widely used to treat limb length discrepancy resulting from trauma, congenital limb defects and long bone non-union. For decades, patients have resorted to the Ilizarov apparatus, prone to pin tract infections and scarring. Although implantable leng...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章

    doi:10.1080/17434440.2019.1599283

    authors: Gaudreau J,Mekhail M,Hamdy R,Villemure I

    更新日期:2019-04-01 00:00:00

  • Portable device for the analysis of liver function: a boon to liver surgery and critical care.

    abstract::Liver biology, liver disease and its management present a myriad of challenges to clinicians. Difficulties arise in determining liver functional capacity, which must be effectively measured in a quantitative reproducible manner. Measurement of indocyanine green (ICG) clearance, an exceptional tool that has been used f...

    journal_title:Expert review of medical devices

    pub_type: 社论

    doi:10.1586/17434440.2016.1126178

    authors: Mobley CM,Zarrinpar A

    更新日期:2016-01-01 00:00:00

  • Treating bladder-outflow obstruction with thermo-expandable prostate metal stents.

    abstract::Bladder-outflow obstruction is a common age-related clinical entity due to a variety of benign and malignant diseases of the prostate. Surgical treatment is not suitable for high-risk elderly patients who seek minimally invasive management. We present a prostatic thermo-expandable metal stent for treating bladder-outf...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/erd.09.13

    authors: Papatsoris AG,El-Husseiny T,Sawada Y,Takahashi T,Nagaoka A,Maan Z,Moraitis K,Masood J,Junaid I,Buchholz N

    更新日期:2009-07-01 00:00:00

  • From portable dialysis to a bioengineered kidney.

    abstract:INTRODUCTION:Since the advent of peritoneal dialysis (PD) in the 1970s, the principles of dialysis have changed little. In the coming decades, several major breakthroughs are expected. AREAS COVERED:Novel wearable and portable dialysis devices for both hemodialysis (HD) and PD are expected first. The HD devices could ...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2018.1462697

    authors: van Gelder MK,Mihaila SM,Jansen J,Wester M,Verhaar MC,Joles JA,Stamatialis D,Masereeuw R,Gerritsen KGF

    更新日期:2018-05-01 00:00:00

  • Crux vena cava filter.

    abstract::Inferior vena cava filters are widely accepted for pulmonary embolic prophylaxis in high-risk patients with contraindications to anticoagulation. While long-term complications have been associated with permanent filters, retrievable filters are now available and have resulted in the rapid expansion of this technology....

    journal_title:Expert review of medical devices

    pub_type: 杂志文章

    doi:10.1586/erd.09.25

    authors: Murphy EH,Johnson ED,Kopchok GE,Fogarty TJ,Arko FR

    更新日期:2009-09-01 00:00:00

  • How prosthetic design influences knee kinematics: a narrative review of tibiofemoral kinematics of healthy and joint-replaced knees.

    abstract:INTRODUCTION:To improve the total knee arthroplasty (TKA) prosthesis design, it is essential to study the kinematics of the tibiofemoral joint. Many studies have been conducted in this area; however, conflicting results and incomparable testing methods make it difficult to draw definitive conclusions or compare researc...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2019.1564037

    authors: Meng F,Jaeger S,Sonntag R,Schroeder S,Smith-Romanski S,Kretzer JP

    更新日期:2019-02-01 00:00:00

  • Advanced methods of spinal stimulation in the treatment of chronic pain: pulse trains, waveforms, frequencies, targets, and feedback loops.

    abstract:INTRODUCTION:Spinal cord stimulation has emerged as a state-of-the-art evidence-based treatment for chronic neuropathic pain and mixed nociceptive-neuropathic pain. In recent years, several newer devices and treatment algorithms have provided unique and effective ways of treating chronic pain by spinal cord stimulation...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2019.1567325

    authors: Maheshwari A,Pope JE,Deer TR,Falowski S

    更新日期:2019-02-01 00:00:00

  • Polyhydroxyalkanoate (PHA): applications in drug delivery and tissue engineering.

    abstract:INTRODUCTION:The applications of naturally obtained polymers are tremendously increased due to them being biocompatible, biodegradable, environmentally friendly and renewable in nature. Among them, polyhydroxyalkanoates are widely studied and they can be utilized in many areas of human life research such as drug delive...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2019.1615439

    authors: Elmowafy E,Abdal-Hay A,Skouras A,Tiboni M,Casettari L,Guarino V

    更新日期:2019-06-01 00:00:00

  • A robot for transnasal surgery featuring needle-sized tentacle-like arms.

    abstract::This paper discusses a new class of robots known as concentric tube robots and their application to transnasal skull base surgery. The endonasal approach has clear benefits for patients, but the surgery presents challenges that strongly motivate the use of robotic tools. In this paper, the concentric tube robot concep...

    journal_title:Expert review of medical devices

    pub_type: 社论

    doi:10.1586/17434440.2013.854702

    authors: Gilbert H,Hendrick R,Remirez A,Webster R 3rd